DelftDI Adora DRFi An advanced hybrid imaging solution combining both static and dynamic X-ray imaging capabilities DelftDI Adora RF has been designed to provide all the benefits of a direct digital Auto-Positioning Radiography system with the added bonus of Fluoroscopy in a single, multi-purpose general X-ray room. l Intelligent workflow for high volume patient throughput l Full APR auto-positioning – no manual handling l Up to 1000 auto-positions l Smart handle motorized movement, zero force l Intuitive tube head control l Acquisition station with large DICOM calibrated touchscreen display l Canon RF acquisition software with generator integration l Extensive portfolio of Canon CXDI Flat Panel Detectors l High resolution, 160µm pixel pitch l High sensitivity l Sophisticated Image processing for highest diagnostic value l Non RF detectors are changeable Specifications Detector (depending on configuration) CXDI-50RF Purpose Multi Purpose Radiography / Fluoroscopy Scintillator CsI (Cesium Iodide) Effective imaging area 430 mm x 350 mm Resolution 3.2 lp/mm DQE >70% Gray scale 4096 gradations Pixel size 160 x 160 μm Image matrix size 2208 x 2688 pixels Dimensions sensor ± 493 x 503 x 26 mm Weight sensor 5.7 kg Acquisition mode Up to 30 fps Cooling Active air cooling Grid Fixed grid Specifications X-Ray generator Type, Indico 100, 150 kV / 80kW Rating KV range KV accuracy Risetime (10-90%) Exposure Time range mAs range mAs accuracy mA range Serial radiography rate • • • • • • • • • 80 kW (65 kW optional in the future) 40 to 150 kV. (radiography) / 40 to 125 kV. (fluoroscopy) +/- 5% + 1 kV over full kV range / +/- 2%+ 1kV from 70 to 85 kV < 0.5 ms 1 ms – 6300m s (detector dependent) 0.1 - 1000 mAs RAD, Non-AEC +/- 10% + 0.2 mAs at > 4ms 10–1000 mA (Rad) – 10 to 80 mA (pulsed fluoroscopy) Up to 15 fps Specifications X-Ray tube & Collimator X-Ray tube • 350 kHU high capacity • 0,6/1,0 focal spot • 12 degrees target angle 150 kV •Dual-speed Collimator type • Fully automatic, motorised with manual override Rotation • +/- 180 motorised Spectral filtration • 1.0mm Al + 0.1mm Cu, motorised,pre-programmable 1.0mm Al + 0.2mm Cu, motorised, pre-programmable Collimation • Motorized square collimation – pre-programmable or controllable via SmartHandle Light Field • Timer-controlled after last system movement. Adora system light dims when the collimator light is active. • 2.0mm Al, motorised, pre-programmable • DAP integration Specifications Ceil stand • Motorized vertical column up to 1600 mm at 3000 mm ceiling height • Fully automatic positioning with 999 APRs • Smart Handle with smooth power -assisted movements • Tube rotation +/- 120° around vertical axis +/- 120° around horizontal axis • Detector rotation +/- 120° around vertical axis +/- 120° around horizontal axis + 90° in z-axis • Ceiling unit rotation +/- 180° at 4-22°/sec • Ceiling Unit Movement 3-25 cm/sec in rails • Full automatic stitching (optional) Specifications Table • • • • • • DelftDI A CANON COMPANY Max patient load Motorized vertical travel Table top dimension Longitudinal Movement Transverse Movement Usefull radiographic area 250kg evenly distributed load 510 – 860mm 2930mm x 700mm +/- 10 cm manual floating +/- 20 cm manual floating 2000mm x 700mm Wiltonstraat 41, 3905 KW Veenendaal, The Netherlands T +31 318 583 400 F +31 318 583 401 E [email protected] I www.delftdi.com
© Copyright 2026 Paperzz