Safety Data Sheet Issuing Date: 12/10/2014 Revision Date: 12/10/2014 SDS PN: 100-411-200 Rev. 01 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND THE COMPANY/ UNDERTAKING Product Identifier Product Name Part Number(s) DNA/Polymerase Binding Kit P6 v2 100-372-700 Relevant Identified Uses of the Substance or Mixture and Uses Advised Against Recommended Use For use with the Pacific Biosciences PacBio RS. FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES. Details of the Supplier of the Substance or Mixture Supplier Address Supplier email Emergency Telephone Number Pacific Biosciences 1380 Willow Road Menlo Park, CA 94025 U.S.A www.pacificbiosciences.com [email protected] Within USA & Canada: Call CHEMTREC 1-800-424-9300 (reference CCN# 656805); Outside USA and Canada: contact [email protected] 2. HAZARDS INDENTIFICATION Classification of the Substance or Mixture GHS / CLP Classification: Health Not Hazardous Environmental Not Hazardous EU Classification (1999/45/EC): Not a dangerous preparation. OSHA / WHMIS Classification: Eye, skin and respiratory irritant GHS/CLP Label Elements: No Labeling required Other Hazards: None Page 1 of 8 Physical Not Hazardous 3. COMPOSITION, INFORMATION OR INGREDIENTS NOTE: Most ingredients are non-hazardous. The two listed components below, in the concentrations present in this kit, are classified as irritants or are listed because they have established occupational exposure limits. Chemical Name CAS-No. EC-No. EU Classification (67/548/EEC) GHS/CLP (1272/2008) Classification Glycerol 56-81-5 200-289-5 Not dangerous Not hazardous Acute Tox 4 (H302) DL-Dithiothreitol Xn, R22 Skin Irrit 2 (H315) 3483-12-3 222-468-7 Solution Xi, R36/37/37 Eye Irrit 2A (H319) STOT SE 3 (H335) See Section 16 for the full text of abbreviations and R and H phrases in this section. Weight % 60-70% 4-8% in water 4. FIRST AID MEASURES Description of First Aid Measures General Advice Move affected individual away from the area of exposure. Eye Contact Rinse thoroughly with water for at least 15 minutes, holding the eyelid open to be sure the material is washed out. Remove contact lenses if present after the first 5 minutes of flushing if easy to do. Continue flushing. Get medical attention if irritation persists. Skin Contact Wash thoroughly with soap and water. If skin irritation develops, seek medical attention. Inhalation Move to area with fresh air. Seek medical attention if experiencing respiratory effects. Ingestion If swallowed, seek medical attention. Notes to Physician This kit contains a few irritants including one sulfur compound (DTT) that smells bad and may present some hazard to persons with underlying respiratory problems and certain allergies. Protection of First-Aiders Wear gloves and take precautions to avoid direct contact with kit materials. Most Important Symptoms and Effects, Both Acute and Delayed Indication of immediate medical attention and Special Treatment Needed May cause eye skin and respiratory irritation. May be harmful if swallowed causing stomach irritation and nervous system effects. Seek medical attention if eye or skin irritation persists after flushing. Seek immediate medical attention if contents of tube 4 are swallowed. 5. FIRE-FIGHTING MEASURES Suitable Extinguishing Media Special Hazards Arising from the Substance or Mixture Dry chemical, carbon dioxide, foam or water. Special Protective Actions for FireFighters Standard gear. Use self-contained breathing apparatus if necessary/desired. Combustion will produce oxides of carbon and sulfur. Page 2 of 8 6. ACCIDENTAL RELEASE MEASURES Personal Precautions Environmental Precautions Wear personal protective equipment (safety glasses, gloves, etc.). Avoid direct skin and eye contact. Avoid breathing vapors. Avoid release to the environment. Report spills and releases as required to appropriate authorities. Methods for Containment Keep containers closed when not in use. Avoid dispersal of spilled material. Methods for Cleaning Up Wear personal protective equipment (safety glasses, gloves, etc.), wipe up, and contain in closed containers. Reference to Other Sections Refer to Section 8 for protective clothing and Section 13 for disposal. 7. HANDLING AND STORAGE Precautions for Safe Handling Standard good lab practices, including use in a well-ventilated area, and PPE (lab coats, safety glasses, and gloves). Conditions for Safe Storage, Including any Incompatibilities Specific end use(s): Keep containers tightly closed at the recommended storage temperature. FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES. 8. EXPOSURE CONTROLS / PERSONAL PROTECTION Control Parameters (Exposure Limits/Guidelines) Chemical Name Exposure Limit 10 mg/m3 (as mist) TWA ACGIH TLV 15 mg/m3 (total), 5 mg/m3 (respirable) TWA US OSHA PEL Glycerol 10 mg/m3 TWA (Belgium, France, Spain, UK) 50 mg/m3 (inhalable) TWA, 100 mg/m3 (inhalable) STEL Germany DL-Dithiothreitol (DTT) None established Exposure Controls: Ventilation: Personal Protective Equipment (PPE): Eye/Face Protection Skin and Body Protection Respiratory Protection Hygiene Measures No special ventilation required for normal use. Safety glasses Latex or nitrile gloves; lab coat /apron None required Standard good laboratory practices Page 3 of 8 9. PHYSICAL AND CHEMICAL PROPERTIES Appearance Odor Odor Threshold None except tube with DTT has unpleasant sulfur smell Flash Point Clear pH 7.5 – 8.0 Not Applicable Autoignition Temperature Boiling Point/Range Not Applicable Water Solubility Soluble VOC Content No data available Decomposition Temp Oxidizing Properties Not Applicable Flammability Limits in Air (Upper) Some liquids; some lyophilized Varies with individual Not Applicable Not determined Flammability Limits in Air (Lower) Physical State Melting Point/Range Not Applicable Partition Coefficient (n-octanol/water) None No data available Explosion Properties Specific Gravity Not Applicable Solubility None Evaporation Rate 1.0 – 1.2 @ 20°C Vapor Pressure No data available Viscosity No data available Vapor Density No data available No data available No data available 10. STABILITY AND REACTIVITY Reactivity Chemical Stability Possibility of Hazardous Reactions: Conditions to Avoid Incompatible Materials: Hazardous Decomposition Products This product is not reactive under normal conditions of storage and use Stable under recommended storage conditions. No data available Avoid excessive heat and open flames. Avoid contact with strong acids, bases, & oxidizers Carbon and sulfur oxides Page 4 of 8 11. TOXICOLOGICAL INFORMATION Information on Toxicological Effects Principle Routes of Exposure Ingestion, inhalation, skin, and/or eye contact Potential Health Effects: Eyes Skin Inhalation Ingestion Chronic Effects Aggravated Medical Conditions Interactions with other Chemicals May cause irritation May cause irritation May cause irritation Ingestion of the contents of tube 4 may be harmful if swallowed causing stomach irritation and nervous system effects. None known None known None known Toxicity Data: Product Information The kit as a whole is not toxic, but a few components may cause irritation upon contact. Component Acute Toxicity Data: Chemical Name LD50 Oral LD50 Dermal LC50 Inhalation DL-Dithiothreitol (DTT) 400 mg/kg - rat No data available No data available Glycerol 12,600 mg/kg - rat >21,900 mg/kg - rat >570 mg/m3 – rat for 1 hr Other Toxicity Data: Skin Corrosion/Irritation Components may irritate the skin. Not corrosive. DTT is a skin irritant. Glycerol in only a slight irritant. Eye Damage/Irritation Components may irritate the eyes on direct contact. DTT is an eye irritant. Glycerol in only a slight irritant. Respiratory Sensitization No component is a respiratory sensitizer. Skin Sensitization No component is a skin sensitizer. Specific Target Organ DTT is a respiratory irritant. Toxicity Carcinogenicity No specific data is available for product. No component is classified as a carcinogen. Reproductive/ Developmental No specific data is available for product. No components known to pose a Toxicity reproductive hazard. Germ Cell Mutagenicity No specific data is available for product. No component is classified as a germ cell mutagen. 12. ECOLOGICAL INFORMATION Ecotoxicity No data available for product. None of the components are classified as harmful to aquatic organisms. Persistence and Degradability No data available for product or most components. Bioaccumulative Potential No data available for product or most components. Results of PBT and vPvB Assessment Other Adverse Effects None Required No data available for product or most components. Page 5 of 8 13. DISPOSAL CONSIDERATIONS Waste Disposal Method(s): CHEMICAL WASTE: The collective components of this kit and the collective waste generated in using this kit are NOT regulated as USA RCRA hazardous waste or as California-only toxic waste. However, it is ultimately the responsibility of the waste generator (end user) to determine the correct disposal method for all waste in accordance with their applicable regulations. BIOLOGICAL WASTE: Under normal use of Risk Group 1 biological materials/agents with this product, the waste is NOT regulated as biohazardous or medical waste. However, other Risk Group materials/agents (2-4) are regulated. International, federal, state, and local regulations vary; and, adherence to the CDC/NIH “Guidelines for Research Involving Recombinant DNA” (or similar regulations in other countries) do (may) require waste treatment of all recombinant DNA. Important: Dispose all waste in accordance with local, national, and/or international regulations. Contaminated Packaging US EPA Waste Number See above None 14. TRANSPORT INFORMATION DOT: Proper Shipping Name Hazard Class Subsidiary Class UN-No Packing Group Description Not regulated N/A N/A N/A N/A N/A IATA/ICAO: UN-No Proper Shipping Name Hazard Class Subsidiary Class Packing Group ERG Code Description Not regulated N/A N/A N/A N/A N/A N/A 15. REGULATORY INFORMATION International Inventories: TSCA For research use only. DSL For research use only. EINECS/ELINCS For research use only. ENCS For research use only. IECSC For research use only. KECL For research use only. PICCS For research use only. AICS For research use only. U.S.A Federal Regulations: No chemicals in the amounts present are reportable under SARA 313. SARA 313 Chemical Name CAS-No Weight % N/A Page 6 of 8 SARA 313-Threshold Values SARA 311/312 Hazard Categories Acute Health Hazard Yes Chronic Health Hazard No Fire Hazard No Sudden Release of No Pressure Hazard Reactive Hazard No None of the chemicals in this product are listed as hazardous substances, Clean Water Act priority pollutants, or toxic pollutants under the Clean Water Act. CERCLA This product is not subject to CERCLA release reporting, however, many states and local authorities have more stringent reporting requirements. Chemical Name Hazardous Substance RQs Extremely Hazardous Substance RQs N/A U.S.A State Regulations: California Proposition 65 International Regulations Canada WHMIS This kit does not contain any chemicals known to the State of California to cause cancer or adverse reproductive health effects. Class D-2-B (irritant) Page 7 of 8 16. OTHER INFORMATION NFPA HMIS® III Acute Health = 1; Flammability = 0; Instability = 0 Acute Health = 1; Flammability = 0; Physical Hazard = 0 Full text of classification abbreviations and R and H phrases for Reference (See Sections 2 and 3): Xi – Irritant Xn Harmful R22 Harmful if swallowed R36/37/38 – Irritating to eyes, respiratory system and skin. Acute Tox 4 – Acute Oral Toxicity Category 4 Skin Irrit 2 - Skin Irritation Category 2 Eye Irrit 2A - Eye Irritation Category 2 STOT SE 3 - Specific Target Organ Toxicity Category 3 H302 Harmful if swallowed H315 Causes skin irritation H319 Causes serious eye irritation H335 May cause respiratory irritation Disclaimer: The information provided on this SDS is correct to the best of our knowledge based on information and belief available at the date of publication. The information contained herein is designed only as a guide for safe handling, use, processing, storage, transportation, disposal, and release. It is not a warranty or quality specification. This information relates only to the specific material designated and may not be valid for use in combination with any other material or in any other process (unless specified in the text). Page 8 of 8
© Copyright 2026 Paperzz