4x |12x Assembly Description 7 3 A 2 4 7 5 D 1 10.0 Connector 1 (left) 6 = 4X 7 = 12X (Not Available in Z Axis or angled configuration) Cable Egress 1 = Straight 2 = Angled 3 = Z Axis 4 = Belly to Belly Connector 2 (right) 6 = 4X 7 = 12X (Not available in Z Axis or angled configuration) Connector 1 (left) Orientation (See “Mech.Orient” sheet) Select one: A,C,E,G,I,K,M,O,S,W,Y Cable Egress 1 = Straight 2 = Angled 3 = Z Axis 4 = Belly to Belly Retention Mechanism 1 = Latch Retention 2 = Thumbscrew Retention Wire Style and AWG 1 = 24 AWG (LSZH) 2 = 26 AWG (LSZH) 3 = 28 AWG (LSZH) 4 = 30 AWG (LSZH) 5 = 24 AWG (PVC) 6 = 26 AWG (PVC) 7 = 28 AWG (PVC) Connector 2 (right) Orientation (See “Mech.Orient” sheet) Select one: B,D,F,H,J,L,N,P,T,X,Z Retention Mechanism 1 = Latch Retention 2 = Thumbscrew Retention Length 00.5 = .5 meters 01.0 = 1 meter 10.0 = 10 meters Please show below any specific labeling requirements. Default labeling includes: Meritec, P/N, and Date Code. Note: Assembly Description shown above to be used for RFQs and ordering purposes. For application specific assemblies not shown in the table, please contact factory. This is not a part number. MERITEC | 1382 WEST JACKSON STREET | POST OFFICE BOX 8003 | PAINESVILLE, OH 44077 888-MERITEC (888-637-4832) / (440) 354-3148 | FAX: 440-354-0687 | WWW.MERITEC.COM / [email protected] 4x |12x Mechanical Orientation Left End Mechanical Orientation Letters Right End Any available “Left End” can be paired with any available “Right End” Short Side Dn 4X/12X Straight Cable Egress A B Straight Cable Egress 4X/12X Short Side Up S1 Short Side Up S1 4X/12X Straight Cable Egress C D Straight Cable Egress 4X/12X S1 S1 Short Side Dn Note: Not Available with Printed Direct Attach (PDA) option S1 Short Side Dn 4X Angled Cable Egress E F Angled Cable Egress 4X Short Side Up S1 S1 Short Side Up 4X Angled Cable Egress G H Angled Cable Egress 4X Short Side Dn S1 Inner edge of the backshell at the latch. See line drawing for details. Short Side Up S1 4X Angled Cable Egress I J Angled Cable Egress 4X S1 Short Side Dn Short Side Dn S1 4X Angled Cable Egress K L Angled Cable Egress 4X S1 Short Side Up Short Side Up 4X 4X Z Axis Cable Egress Short Side Dn M N P 4X 4X Short Side Dn Short Side Up O Custom/Other Conn. Cable Egress Outer Jacket Strip No Termination Custom/Other Conn. S T Cable Egress W X Outer Jacket Strip Y Z No Termination Cable Assembly Nominal Length Tolerance: <1Meter, +/– 40mm; 1 through 10 Meter, +/– 70mm; >10 Meter, +/– 100mm Note: The broken line view is from the rear of the backshell and the solid line view is from the mating face of the connector. MERITEC | 1382 WEST JACKSON STREET | POST OFFICE BOX 8003 | PAINESVILLE, OH 44077 888-MERITEC (888-637-4832) / (440) 354-3148 | FAX: 440-354-0687 | WWW.MERITEC.COM / [email protected]
© Copyright 2024 Paperzz