Gasbrenner neue Texte.fm

Teclu burners
Teclu burners
Technical specifications:
Technical specifications:
Suitable for propane gas or natural gas. Made of die-cast zinc.
Connection for hose with internal dia. 9.5 mm.
Gas type
Propane gas
Natural gas
Temperature (°C)
➀ 1320
➁ 1285
➂ 1380
➀ 1290
➁ 1300
➂ 1330
Consumption (l/h)
➀ 50
➁ 53
➂ 76
➀ 145
➁ 150
➂ 218
➀ With needle valve and air control
For gas type
Overall height Weight (g)
(mm)
Propane gas
165
285
Natural gas
165
285
Pack Qty
CHP4.1
CHP5.1
1
1
Pack Qty
1
1
➂ With needle valve, extended heat output and air control
For gas type
Overall height Weight (g)
Art. No.
Pack Qty
(mm)
Propane gas
165
360
CHT0.1
1
Natural gas
165
360
CHT1.1
1
2
Gas type
Propane gas
Head dia. (mm)
➀ 17
➁ 17
➂ 32
➀ 17
➁ 17
➂ 32
Art. No.
➁ With stopcock, pilot flame and air control
For gas type
Overall height Weight (g)
Art. No.
(mm)
Propane gas
170
310
CHP8.1
Natural gas
170
310
CHP9.1
Acc. to DIN, DVGW approved. Suitable for propane gas or natural gas.
Connection for hose with 9.5 mm internal dia. Made of die-cast zinc.
Natural gas
€
36,70
36,70
€
45,95
45,95
€
Temperature (°C)
➀ 1320
➁ 1285
➀ 1290
➁ 1300
➂ 1330
➀ With needle valve and air control
For gas type
Overall height Weight (g)
(mm)
Propane gas
165
285
Natural gas
165
285
Consumption (l/h)
➀ 50
➁ 53
➀ 145
➁ 150
➂ 218
Head dia. (mm)
➀ 17
➁ 17
➀ 17
➁ 17
➂ 32
Art. No.
Pack Qty
CHT6.1
CHT7.1
1
1
➁ With stopcock, pilot flame and air control
For gas type
Overall height Weight (g)
Art. No.
(mm)
Propane gas
170
310
Y565.1
Natural gas
170
310
Y566.1
Pack Qty
1
1
➂ With needle valve, extended heat output and air control
For gas type
Overall height Weight (g)
Art. No.
Pack Qty
(mm)
Natural gas
165
360
CHT9.1
1
€
39,80
39,80
€
55,00
55,00
€
55,00
51,50
51,50
Bestellung zum Nulltarif Tel. 0800/5699 000 · Fax 0721/5606 149 · www.carlroth.de · [email protected]
Laboratory gas burners with suction foot
Laboratory gas burners with double lever stopcock
Acc. to DIN, DVGW approved. Connection for hose with
9.5 mm inside ∅. Suitable for propane gas or natural gas.
With suction foot:
• For stability on all smooth surfaces
• Accidental movement of the burner is largely excluded
• No metal in contact with the standing area
Acc. to DIN, with DVGW-approval. Connection for hose with inner-∅
10 mm. For propane gas or natural gas. With double lever stopcock , low
heat flame and air regulation.
For gas type
Overall height Weight (g)
Art. No.
Pack Qty
€
(mm)
Propane gas
150
290
CX71.1
1
49,50
Natural gas
150
290
CX72.1
1
49,50
Technical specifications:
Gas type
Propane gas
Natural gas
Temperature (°C)
➀ 1220
➁ 1210
➂ 1320
➀ 1300
➁ 1260
➂ 1290
Consumption (l/h)
➀ 40
➁ 44
➂ 50
➀ 115
➁ 125
➂ 145
Head dia. (mm)
➀ 17
➁ 17
➂ 17
➀ 17
➁ 17
➂ 17
➀ With needle valve and air control - Bunsen gas burner
For gas type
Overall height Weight (g)
Art. No.
Pack Qty
(mm)
Propane gas
145
250
CK28.1
1
Natural gas
145
250
CK29.1
1
€
36,95
36,95
➁ With stopcock, pilot flame and air control - Bunsen gas burner
For gas type
Overall height Weight (g)
Art. No.
Pack Qty
€
(mm)
Propane gas
150
280
CK30.1
1
44,50
Natural gas
150
280
CK31.1
1
44,50
➂ With needle valve and air control- Teclu gas burner
For gas type
Overall height Weight (g)
Art. No.
Pack Qty
(mm)
Propane gas
165
285
CK32.1
1
Natural gas
165
285
CK33.1
1
€
46,00
46,00
Safety lab burners according to Teclu
With thermo sensor safety valve (if the flame extinguishes or the gas supply
is interrupted, the safety valve closes automatically). Solid round base.
With air regulation and needle valve.
For gas type
Overall height Weight (g)
Art. No.
Pack Qty
€
(mm)
Propane gas
180
650
NA04.1
1
136,00
Natural gas
180
650
NA05.1
1
136,00
Mengenrabatte von 5 % ab 6 Packungen und 10 % ab 24 Packungen gleicher Bestellnummern!
3
Laboratory Bunsen burners
Laboratory Bunsen burners
Technical specifications:
Technical specifications:
Suitable for propane gas or natural gas. Made of die-cast zinc.
Connection for hose with 9.5 mm inside ∅.
Gas type
Propane gas
Natural gas
Temperature (°C)
➀ 1220
➁ 1180
➀ 1300
➁ 1240
Consumption (l/h)
➀ 40
➁ 43
➀ 115
➁ 123
➀ With needle valve and air control
For gas type
Overall height Weight (g)
(mm)
Propane gas
145
250
Natural gas
145
250
Acc. to DIN, DVGW approved. Suitable for propane gas or natural gas.
Connection for hose with 9.5 mm internal ∅. Made of die-cast zinc.
Head dia. (mm)
➀ 17
➁ 17
➀ 17
➁ 17
Art. No.
Pack Qty
CHP0.1
CHP1.1
1
1
➁ With lever stopcock, pilot flame and air control
For gas type
Overall height Weight (g)
Art. No.
Pack Qty
(mm)
Propane gas
150
310
C633.1
1
Natural gas
150
310
C634.1
1
Gas type
Propane gas
Natural gas
€
27,40
27,40
€
42,50
42,50
Temperature (°C)
➀ 1220
➁ 1220
➂ 1220
➃ 1210
➀ 1300
➁ 1300
➂ 1250
➃ 1260
➀ Basic version with air control
For gas type
Overall height Weight (g)
(mm)
Propane gas
145
240
Natural gas
145
240
➁ With needle valve and air control
For gas type
Overall height Weight (g)
(mm)
Propane gas
145
250
Natural gas
145
250
Consumption (l/h)
➀ 42
➁ 40
➂ 42
➃ 44
➀ 120
➁ 115
➂ 120
➃ 125
Head dia. (mm)
➀ 17
➁ 17
➂ 17
➃ 17
➀ 17
➁ 17
➂ 17
➃ 17
Art. No.
Pack Qty
Y561.1
Y562.1
1
1
Art. No.
Pack Qty
Y563.1
Y564.1
1
1
➂ With needle valve, pilot flame and air control
For gas type
Overall height Weight (g)
Art. No.
Pack Qty
(mm)
Propane gas
145
250
CHT2.1
1
Natural gas
145
250
CHT3.1
1
➃ With stopcock, pilot flame and air control
For gas type
Overall height Weight (g)
Art. No.
(mm)
Propane gas
150
280
CHT4.1
Natural gas
150
280
CHT5.1
4
Pack Qty
1
1
€
26,20
26,20
€
34,60
34,60
€
39,80
39,80
€
39,80
39,80
Bestellung zum Nulltarif Tel. 0800/5699 000 · Fax 0721/5606 149 · www.carlroth.de · [email protected]