AreaCare Zephyr

AreaCare Zephyr
Foam Air Combination Surface
2
YEAR
230 kg
foam/air combination
warranty
180 mm
Designed for optimal comfort for patients at risk or low risk of pressure injury,
the AreaCare Zephyr is a unique foam air combination system – a three layered
memory foam mattress enhanced by a powered air system to increase pressure
redistribution capabilities. Ideally suited for palliative care or patients suffering from
joint pain, dysmorphic body shape or at risk of post intensive care syndrome.
A full mattress replacement system, the Zephyr can be used on both a
standard or profiling bed frame. The ideal bridging surface between
static and dynamic, offering superior comfort and increased protection
for patients still able to reposition themselves.
AreaCare Zephyr
Pressure Mapping
therapy &
comfort
Percentage of interface pressure between:
20-30 mmHg of pressure: 38.2%
›› 10-20 mmHg of pressure: 48.1%
›› 0-10 mmHg of pressure: 2.1%
››
Maximum contact area (immersion) = 3866.13 cm2
›› Average interface pressure across
contact surface = 20.4mmHg
0 mmHg
10
20
30
40
50
60
Image taken during mid-cell-cycle using XSensor® mapping equipment.
Male test subject, aged 36 years, 1.68 metres tall, 78 kilograms, BMI 27
Top Cover
Multi-stretch material for reduced shear and
friction. Seams are stitched for strength,
and welded for maximum infection control. Material is
pre-treated for protection against mould, mildew and
bacteria. Includes essential labelling information for
safety and convenience.
safety
Power Cord Retention System
Series of loops inbuilt along the mattress
base, designed to retain the power cord for
safer storage. Reduces potential as a trip hazard and
accidental disconnection from power.
safety
Hanging Hooks
Quick-Release Connector
Air hose quick release connectors are easy to
attach and detach (for emergency deflation).
During patient transport or transfer, ends can be snapped
together to retain air in the mattress for up to 24 hours (time
frame dependent on patient weight and circumstances).
usability
usability
Rear hooks allow the unit to hang from bed
ends. Alternatively the unit can be placed flat
beneath the bed.
Top Foam Layer
Convoluted ‘eggshell’ visco-elastic memory foam to aid microclimate
management while increasing body contact with support surface
therapy &
comfort
Middle Foam Layer
Higher resistance support layer to evenly disperse
pressure, irrespective of bodyshape or resting position
therapy &
comfort
Heel Zone
Gently sloped to reduce pressure exertion on the heels,
helping prevent pressure injuries and joint hyperextension
therapy &
comfort
Alternating Air Cells
8 cylindrical air cells which inflate and deflate in sequence to vary
pressure distribution across the vulnerable scapula (shoulder
blade) to sacral (base of spine); maximising the contact area
while simultaneously altering the interface pressure
therapy &
comfort
Safety Side Bolster
Provides structural integrity to the mattress and
helps prevent the patient from falling, or the
mattress collapsing when someone sits on the edge
safety
Base Foam Layer
Firm, high resilience foam to produce
form, strength and stability
therapy &
comfort
Pressure Adjustment Dial
A simple dial allows the pressure level to be adjusted to
match individual user weight and comfort needs.
Comprehensive Labelling
usability
Safety and operating instructions are
clearly labelled on the control unit for
easy set-up and operation.
usability
Compact Control Unit
Powerful compressor allows fast mattress initialisation
(ready for use within 15 minutes) and supports a load of
up to 230 kilograms, ideal for the heavier patient
The compact control unit provides a visible alarm in the
event of low mattress pressure
safety
Specifications
General
Control Unit
Support
Surface
C OD E
BSFA7000
PAT IE N T WEIGHT RANGE
30-230 kg
TR A N SP ORT M ODE
4
WA R R A N TY
2 year
A RT G
194369
O PE R AT ION
Analogue - Continuous
Easy to operate
A LA R M MODE
Visual
Visual alert to notify carer of low cell pressure
D IMEN SIONS
W 170 H 270 D 110 mm
PR ES S U R E RANGE
30 - 60 mmHg
C Y C LE T IME
12 minutes
U N IT WE IG HT
2.1 kg
POWE R IN P UT
240 V, 50 cycle AC
D IMEN SIONS
L 1960 W 860 H 180 mm
MATT R ES S WEIGHT
13 kg
N U MB ER O F CELLS
8 cells
C E LL D IA METER
125 mm
AreaCare Zephyr Powered Foam Air Surface
Retains air for up to 24 hours without power
Replaces a standard mattress
Top Layer
Convoluted visco-elastic memory foam for optimal comfort and immersion
Support Layer
High resilience PU foam for support
Base Layer
Firm core base layer gives mattress integrity and support
Side Bolsters
Firm sidewalls help prevent patient from rolling, or mattress collapsing when
seated on edge
FO A M TR EATM ENT
Anti-bacterial
Additive to prevent fungal and microbe growth on cover and foam
B A SE MAT E RIAL
PVC
FO A M C OM POSITION
TOP C O V ER
PU Fabric
High grade polyurethane, multi-stretch, waterproof and vapour permeable
Flame Retardance
To BS5852 Standard, suitable for use in hospital and care facilities
T H E R A P E U T I C D E V I C E S S H O U L D O N LY B E U S E D I N A C C O R D A N C E W I T H M A N U FA C T U R E R S I N S T R U C T I O N S A N D U N D E R T H E C O N S E N T,
S U P E R V I S I O N A N D M A N A G E M E N T O F A S U I TA B LY Q U A L I F I E D H E A LT H P R O F E S S I O N A L .
I N F O R M AT I O N C O R R E C T AT T I M E O F P R O D U C T I O N ( J U N E 2 0 1 6 ) © 2 0 1 6 N O V I S H E A LT H C A R E . A L L R I G H T S R E S E R V E D .
bringing you the world in health
ABN 45 102 735 491
Novis Healthcare
12/12 Mars Road Lane Cove 2066
New South Wales Australia Jun16
T 1300 738 885
www.novis.com.au