580 13 CUT LINE Notes: AD CUT LINE 46 Junction Visibility Splay RO Key: GE RA 25 Plane out 50mm of existing carriageway (repairs to binder course to be carried out as required) 50mm HRA 35/14 with 20mm chipping to be laid prior to the application of the red anti-skid material. Minimum PSV of 70. Limit of Works Boundary (To existing features. Agreed in meeting with CBC Highways 29.03.2016) Proposed Tactile Paving (Buff coloured unless noted otherwise) 1. Do not scale from this drawing. 2. All dimensions are in metres unless stated otherwise. 3. This drawing is to be read in conjunction with all relevant Engineers and Architects Drawings, Specifications, Reports and Engineering Details. 4. All Highway works are to be constructed in accordance with Central Bedfordshire's (CBC) Design Guide and with Manual for Streets (latest addition). Approval is to be sought by Highways (CBC) prior to construction if works deviate away from the standards outlined within these documents. 5. This drawing to be read in conjunction with drawing T7598/PH - 220 - Section 278 Construction Notes Proposed 15mm imprint surface. PSV 68. Colour: Prismo Red. RS06 68m 6.3 Proposed Traffic Sign with a 60m (min) clear visibility splay for a 30mph approach and a 75m (min) clear visibility splay for a 40mph approach CBC Horticulture and Arboriculture officer to confirm tree strategy 600 RS07 2m 19 Proposed Anti Skid. PSV 70. Existing lighting column to be relocated to back of proposed footway. 6 3 2 20 1 Proposed retaining wall. Type to be agreed with highways. (Height will vary along extents). Specification to be agreed with CBC. Highfield Bungalow 109 Highfield House 101 97 Highfield Barn 132 91 83 130 8m Mallatite tubular galvanised column with thermoplast coating with post top Philips Luma 60-120 DS-NW 1 10000 NW LED lantern, RAL 9007 and switch regime at 35:18 lux. Install double pole isolator at base of the column 1 81 73 79 Existing column and lantern to remain 71 65 AD LD IE Brethrens 57 6 Meeting Fields 63 View RO F CH UR CH 88 House The Corner House 55 Bankside 76 2 49 7 4 18 Proposed 0.5m verge (150mm (min) topsoil and seed) to face of retaining structures Proposed 3m Simmonsign Modupost with 3m extension and install Libra Retro 28LED left handed black lantern with 70lux photocell 34 10 8 SE 12 CLO 8 DE KSI BAN 22 2 Existing column and lantern to be disconnected and removed to tip. Private / DNO feed to be disconnected 620 BIDW ELL H ILL 5 64 240 8 (PH) 1 F:4.5m x D:25m 008 Red Lion 38 2m Contractor to seek approval from all appropriate bodies prior to construction commencing on the existing tress that are to remain 1 016 2 The Old CBC Horticulture and Arboriculture officer to confirm tree strategy 007 Supply cables 3 core 6mm² XLPE / PVC / SWA / PVC laid in 50mm Ø orange duct for private network, laid at minimum cover depth of 450mm in footpath and 750mm in carraigeway Forward Visibility Splays Existing Bus Stop Chainage marker Post HOUGHTON REGIS Proposed highway drainage Car Park 2m Existing footway to be widened 30 El Sub Sta 640 30 LOCATION MAP (1:5000) Existing lighting column to be relocated to back of proposed footway. Top of raised tables to be smooth underneath thermplastic markings and white lining. 36 CBC Horticulture and Arboriculture officer to confirm tree strategy Road Safety Audit Stage 1-2 Problem 3.2.3 007 Solution: Agreed. Consistent surface material to be provided over extent of raised table and parking bays 2m 2m Non location references items: Problem 3.1.1 Solution: Agreed. Crossing relocated. Vegetation to be cut back and cleared within extents of visibility splays. 29 Proposed raised table 50mm thick HRA surface course Type F 30/14, PSV 68 15mm thick "Imprint" surface Colour "Prismo Red" Amey Road Safety Audit Stage 1-2 Ref. 904251/RSA2/DR/442 660 Tie into existing footway Problem 3.1.3 28 Solution: Agreed. Buff HFS removed. Skid resistant road markings, street lighting and raised thermoplastic markings to be provided to increase conspicuity. Problem 3.2.1 Existing Bus Stop Problem 3.2.2 Road Safety Audit Stage 1-2 Problem 3.1.2 Vicarage Solution: Agreed. Raised table extended to incorporate bus stop and accesses 27 GG Solution: Agreed. Existing kerbs to be raised or replaced to appropriate levels along raised features. Problem 3.4.1 Solution: Agreed. Tactile crossing layouts have been amended. 0 W D I B Solution: Agreed. Bullnosed kerb with upstand to be provided along raised features. 68 L EL L L I H 006 Problem 3.4.2 Vehicular access Solution: Agreed. All existing street furniture to be relocated to back of proposed footways. Road Safety Audit Stage 1-2 Problem 3.4.3 Provide temporary "New Road Layout Ahead" road sign. Diagram no. 7014 (variant) with 60m (min) clear visibility splay. Exact position to be agreed with CBC representative on site. Sign to be removed after three months. Problem 3.5.6 Solution: Agreed. Uncontrolled crossing facility to be removed. Tactile crossing provided on raised table on Bedford Road. Solution: Agreed. No proposed steps on the adoptable highway. Hand rails to be provided on site where height of steps exceed 600mm. Problem 3.5.7 22 Solution: Agreed. Street lighting design provided. 0 70 o3 2t 6, 9, 31 Be on ac Mam-Tor 72 0 0m :6 vis 2 Existing tactile crossing Street lighting design to be updated to suit relocated crossing Indicative Belisha beacon. Position to be confirmed following updated street lighting design 5m 20 MP4 1. Proposed 15mm imprint surface. Colour: Prismo Red MP3 Top of raised tables to be smooth underneath thermplastic markings and white lining. Street lighting design to be updated to suit relocated crossing 1 Ivydene House 004 HOUGHTON REGIS Vehicular access Dropped crossing 76 0 Vehicular access Existing full height kerb Existing double yellow lines Bea Indicative Belisha beacon. Position to be confirmed following updated street lighting design con vis: 60m 780 n Sig BE 5m :4 vis Watling Court 003 Existing bus stop 1t 800 6 1 o RS06 RS07 RS6 RS06 RS07 RS6 DF OR DR 9 Rev C Drawings updated to suit CBC comments received (13.05.2016). By CM Checked TH Date 26.05.2016 Rev B Drawings updated following CBC meeting (29.03.2016). By CM Checked TH Date 05.04.2016 Rev A Drawings updated to suit CBC comments received (22.01.2016). By CM Checked TH Date 24.03.2016 OA Client D TAYLOR WIMPEY 82 0 Sig nv Existing bus stop is:4 Project HOUSING DEVELOPMENT 5m BEDFORD ROAD Existing crossover HOUGHTON REGIS 6 0 (SHEET 3 OF 3) 4a Scale at A0 Existing crossover 1:250 Drawn by Status 4 Provide temporary "New Road Layout Ahead" road sign. Diagram no. 7014 (variant) with 60m (min) clear visibility splay. Exact position to be agreed with CBC representative on site. Sign to be removed after three months. SECTION 278 WORKS GENERAL ARRANGEMENT 84 Existing crossover Title 5 S H C I TM LS E A E V A E U N 0 74 8 Provide temporary "New Road Layout Ahead" road sign. Diagram no. 7014 (variant) with 60m (min) clear visibility splay. Exact position to be agreed with CBC representative on site. Sign to be removed after three months. Bedford Court 005 Vehicular access FOR TECHNICAL APPROVAL CM Checked by Project ref T7598/PH TH Date Drawing no. 211(3) MARCH 2015 Revision C
© Copyright 2026 Paperzz