Safety Data Sheet 1. Chemical Product and Company Identification Product Name: Application: Needle Counters Intended purpose is for holding sharps whilst easily keeping count of the sharps during surgical procedures Supplier: Linear Medical Pty Ltd Level 9, 154 Pacific Highway St Leonards NSW 2065 1300 782 365 www.linearmedical.com.au Telephone: Website: 2. Hazards Identification Product Information: Not classified as dangerous substance or product. Potential Health Effects: Eyes: No health effects are expected. This product is not known to cause eye irritation. However, as with any chemical, some individuals may have experience sensitivity to this product. They may experience eye irritation, seek medical advice if required. Skin: No health effects are expected. Inhalation (Breathing): Negligible hazard at room temperature. Ingestion (Swallowing): Unlikely to occur, no health effects are expected. Signs and Symptoms Carcinogenicity: Target organs: No data available No data available Developmental: No data available Physical Hazards: No physical hazards were determined from a review of available information 3. Composition / Information on Ingredients Component Top cover and base Isotropic Rubber Magnets Foam Block / Strips Raw Material HIPS (high impact Polystyrene) Magnetic powder CPE Oil Ethylene/Vinyl acetate copolymer Concentration ≥ 80% 84%~86% 10%~12% 3%~5% ≥ 98% Linear Medical |Version 1.0 | 24.01.2014 1 4. First Aid Measures Skin Contact: if skin irritation occurs, seek medical advice Eye contact: if eyes come into contact with the components or its dust, flush eyes with plenty of water for at least 15 minutes. Seek medical attention if eye irritation persists. Inhalation (Breathing): Unlikely to occur. Ingestion (Swallowing): unlikely to occur. 5. Fire Fighting Measures OSHA Flammability Class: Non-flammable. May be combustible at high temperature. Flash Point: Not applicable Auto ignition Temperature: 440 ℃ LEL/UEL: Not applicable Sensitivity to Static Discharge: Not applicable Explosion Data (Sensitivity to Impact): Not applicable Hazardous Combustion Products: Carbon oxides (Co, CO2.) and soot. Extinguishing Media: Use Dry chemicals, CO2, water spray, foam or other extinguish media appropriate for surrounding fire. Fire Fighting Instructions: Wear appropriate personal protective equipment. Special Fire and Explosion Hazard: Fire may produce irritating gases and dense smoke. Flowing material may produce static discharge, ignition dust accumulations. 6. Accidental Release Measures Personal Precautions: There are no special technical measures involved for handing this product; Normal precautions should be taken to avoid physical injury when using the product with sharps, these refers to the surgical blade or suture needles. Leak and Spill Procedures: Use a convenient waste disposal container to contain any accidental release or spill. 7. Handling and Storage Handling Precautions: Prevent from fire around handling area. Maintain good housekeeping standards to prevent accumulation of dust. Gloves should be worn. Storage Conditions: Keep the products at a cool dry place. Protect from direct sunlight, rain and violent temperature fluctuation. Fire is inhibited around storage area. Packaging Material: Waterproof material should be used. Acute Toxicity: No data available Skin Corrosion/ Irritation: No data available Serious eye Damage/Irritation: No data available Respiratory or Skin Sensitization: No data available Germ Cell Mutagenicity: No data available Carcinogenicity: No data available Reproductive Toxicity: No data available Specific Target Organ Toxicity(STOT)- Single exposure: No data available Specific Target Organ Toxicity(STOT)- Repeated exposure: No data available Aspiration Hazard: No data available Linear Medical |Version 1.0 | 24.01.2014 2 8. Exposure Controls / Personal Protection Standard: Engineering Controls: Personal Protective Equipment: Respiratory: Eye/Face: Skin and Body Protection: Further Protective Measures: Hygiene Measures: No data available Appropriate fresh air and exhaust ventilation. Dependent upon process being performed on material each operation must be addressed for suitable tool or equipment. No special requirement. Ventilation is normally required when handing this product at high temperatures. Wear appropriate respirator when ventilation is inadequate. Wear masks as required. No special requirement. In mechanical processing, wear eye/face protective (safety glasses or goggles) as required to avoid possible eye irritation. No special requirement. Wear gloves as required. No special requirement. No special requirement. 9. Physical and Chemical Properties Appearance: Physical State/Form: Colour: Odour: PH(1% Soln/Water): Flash Point: Ignition Point: Decomposition temperature: Melting/Freezing Point: Critical temperature: Boiling Point: Vapor Pressure: Vapor Density: Evaporation Rate: Viscosity: Solubility in Water: Specific Gravity: Coefficient Water/ Oil Distribution: Solid Solid sheet Optional, as required Odourless. No data available. 350℃. 420.℃. > 250℃. > 132.22℃. No data available. No data available. No data available. No data available. No data available. No data available. Insoluble in water. 1.03-1.05(HIPS) (Water=1). No data available. 10. Stability and Reactivity Chemical Stability: Stable and non-reactive under normal handling and storage conditions. Avoid too high temperature. Reactivity: Stable under the normal temperature for water and air. Hazardous Polymerization: Hazardous polymerization cannot occur. Incompatibility to be Other Substances: Reactive with strong oxidizing agents. Hazardous Decomposition Products: Hazardous decomposition products are carbon monoxide, carbon dioxide, dense smoke and hydrocarbons. Exposure of polystyrene to extremely high temperature may cause partial decomposition. Chemicals that may be release include styrene monomer, benzene and other hydrocarbons. Linear Medical |Version 1.0 | 24.01.2014 3 11. Toxicological Information Acute Toxicity: No data available Skin Corrosion/ Irritation: No data available Serious eye Damage/Irritation: No data available Respiratory or Skin Sensitization: No data available Germ Cell Mutagenicity: No data available Carcinogenicity: No data available Reproductive Toxicity: No data available Specific Target Organ Toxicity (STOT) - Single exposure: No data available Specific Target Organ Toxicity (STOT) - Repeated exposure: No data available Aspiration Hazard: No data available 12. Ecological Information Ecotoxicity: Persistence: Degradability: Bioaccumulative Potential: Mobility in Soil: Other adverse effects: No data available for the material as a whole. However, individual components of the material have been found to be toxic to the environment. No data available. No data available. No data available. No data available. No data available. 13. Disposal Considerations Waste information: Controlled incineration or landfill according to local, state or national laws and regulations concerning health and pollution. Inadequate incineration may generate toxic gases such as CO and SM. Disposal notice: Avoid disposing of product into waterways. 14. Transport Information General Shipping Information: UN Number: Proper shipping name: Transport hazard Class (es): Packing Group: Environmental Hazards: Special Precautions During Transport: Hazchem Code: Other Information: Material not regulated for shipping. No data available No data available No data available No data available No data available No data available No data available Not dangerous cargo. Linear Medical |Version 1.0 | 24.01.2014 4 15. Regulatory Information Not available 16. Other Information To the best of our knowledge, the information contained herein is accurate. However, neither the above named supplier nor any of its subsidiaries assumes any liability whatever for the accuracy or completeness of the information contained herein. Final determination of suitability of any material is the sole responsibility of the user. All materials may present unknown hazards and should be used with caution. Although certain hazards are described herein, we cannot guarantee that these are the only hazards that exist. END OF REPORT Linear Medical |Version 1.0 | 24.01.2014 5
© Copyright 2026 Paperzz