GE Healthcare Life Sciences Instructions 28-9978-87 AB Biacore™ PBS-P+ buffer, 10x Order code: 28995084 Contents: Aqueous buffer containing 0.2 M phosphate buffer with 27 mM KCl, 1.37 M NaCl and 0.5% Surfactant P20 (Tween 20). Sterile filtered. Will yield pH 7.4 when diluted and supplemented with 2% DMSO. Package: 1000 ml Storage: Store at room temperature (precipitation may occur at low temperature). The use-before date stated on the bottle label applies to unopened bottle. For in vitro use only. Material Safety Data Sheet (MSDS) is available at www.gelifesciences.com\biacore. Intended use PBS-P+ buffer, 10x is used for the preparation of running buffer with DMSO, which is commonly used for small molecule assays in Biacore instruments. The 10x buffer is optimized for 2% DMSO, but other DMSO concentrations may also be used, see “PBS-P+ buffer with other DMSO concentrations” on page 2. Prepare PBS-P+ buffer with 2% DMSO To prepare PBS-P+ buffer with 2% DMSO, do the following: 1 Prepare a 1.02x PBS-P+ solution as follows: Dilute the 10x solution with deionized, 0.2 µm filtered water, e.g. by mixing 102 ml 10x solution and 898 ml water. This solution is used for the preparation of running buffer (as described below), solvent correction stock solutions and samples. 2 Prepare PBS-P+ running buffer with 2% DMSO as follows: Dilute 100% DMSO with 1.02X PBS-P+ solution, e.g. by mixing 20 ml 100% DMSO and 980 ml 1.02X PBS-P+ solution. Refer to www.gelifesciences.com/biacore for laboratory guidelines for buffer and sample preparation for direct binding assays in DMSO. 3 Degas the buffer before use in systems without degasser. Follow the instructions in the instrument manual for start-up with new buffer. PBS-P+ buffer with other DMSO concentrations If buffer with other DMSO concentrations than 2% is prepared, the pH-value will change according to Fig 1 (data obtained at room temperature). 7 7 pH-value 7 7 7 7 7 7 7 0% 1% 2% 3% 5% DMSO concentration 8% 10% Fig 1. The graph displays the pH-value at different DMSO concentrations. 2 28-9978-87 AB Note: 28-9978-87 AB If using PBS-P+ running buffer with additives containing metal ions, make sure that it is compatible with BIAdesorb solution 1 before running the Desorb or Desorb and Sanitize procedures (SDS will precipitate with some common metal ions such as K+ and Mg2+). 3 For local office contact information, visit www.gelifesciences.com/contact GE Healthcare Bio-Sciences AB Björkgatan 30 751 84 Uppsala Sweden www.gelifesciences.com/biacore www.gelifesciences.com GE Healthcare Europe GmbH Munzinger Strasse 5, D-79111 Freiburg, Germany GE Healthcare UK Ltd Amersham Place Little Chalfont Buckinghamshire, HP7 9NA UK GE Healthcare Bio-Sciences Corp 800 Centennial Avenue P.O. Box 1327 Piscataway, NJ 08855-1327 USA GE Healthcare Japan Corporation Sanken Bldg. 3-25-1, Hyakunincho Shinjuku-ku, Tokyo 169-0073 Japan GE, imagination at work and GE monogram are trademarks of General Electric Company. Biacore is a trademark of GE Healthcare companies. © 2011 General Electric Company – All rights reserved. First published Jun. 2011. All goods and services are sold subject to the terms and conditions of sale of the company within GE Healthcare which supplies them. A copy of these terms and conditions is available on request. Contact your local GE Healthcare representative for the most current information. imagination at work 28-9978-87 AB 06/2011
© Copyright 2026 Paperzz