Pre-Installation CUSTOMER REQUIREMENTS ENDODRY Storage & Drying System This document provides the facility with requirements to ensure correct installation and subsequent proper performance of the ENDODRY Storage and Drying System. 1 APPLICABLE DOCUMENTS 2 CUSTOMER REQUIREMENTS 3 AIR SUPPLY 4 5 • ENDODRY Storage and Drying System User Manual This criteria must be met to ensure proper operation of the drying cabinet. It is the responsibility of the customer to provide qualified personnel to install proper electrical and air supply prior to install. • ENDODRY Storage and Drying System uses compressed air according to ISO 8573-1:2010, class 1.4.1 (alternatively medical compressed air) from the equipment provided cable assemblies (quick connector). • The required air pressure is 29-116 psi (2-8 bar). The demand of compressed air is a maximum flow rate of 3.4 cfm (95 l/min) (ANR) and 0.6 cfm (16 l/min) @ 72 psi (5 bar). • A flexible air pipe with ¼” or 6 mm inner diameter (EPDM/PVC, bound, 150 psi minimum (10.5 bar) minimum length 5 feet (1.5m)) is required to connect the ENDODRY Storage and Drying System with the air pressure system. The 6.5 foot (2 meter) line is included in the shipment. ELECTRICAL SUPPLY • 100-240 VAC ± 10%, single phase, 50/60 Hz, 15 amp circuit • Power input: 75W • A GFI protected outlet (NEMA 5-15R) within 3 feet (1 meter) of the installation and within reach of the operator. • It is recommended to install a surge protector to protect the ENDODRY Storage and Drying System from voltage spikes. SPACE AND FLOORING • Self containing leveling pads should be adjusted during installation. For optimal user-safety and operation, it is recommended that the ENDODRY Storage and Drying System always be placed directly on the floor, and not on an elevated platform type device. • Dimensions: H75” X W24” X D22” (190cm x 60cm x 54cm) • Weight: 375 lbs (170 kg) 6 REMOTE ACCESS (NETWORK) • If applicable, the control system of the ENDODRY™ Storage and Drying System can be connected to an ADVANTAGE PLUS® Automated Endoscope Reprocessor(s) or a computer by LAN interface (1xRJ45, 10/100 Mbit) and be operated by a remote client. • Network and internet access are highly recommended to use the external remote function for accessing the ENDODRY Storage and Drying System. - A network connection to an ADVANTAGE PLUS AER allows for the transfer of operator and endoscope information. ENDODRY STORAGE AND DRYING SYSTEM REQUIREMENTS CHECKLIST The ENDODRY Storage and Drying System Installation Checklist is utilized to ensure the installation site meets the required specifications. If all requirements are met, the site is suitable for the installation of the cabinet. Section Customer Site Requirements Criteria 3 Air supply provides a minimum of 29 PSI (2 BAR) and not to exceed 116 PSI (8 BAR) 3 Air supply provides a maximum flow rate of 3.4 cfm (95 l/min) (ANR) and 0.6 cfm (16 l/m) @ 72 psi (5 BAR) 4 GFI protected outlet (NEMA 5-15R) within 3 feet (1 meter) of the installation and within reach of the operator 5 Proposed installation area has a level floor 5 Installation site accommodates the units dimentions (H75” x W24” x D22” (190cm x 60cm x 54cm)) By signing below, the customer acknowledges that; (1) The customer has reviewed the Site requirements for the MEDIVATORS™ ENDODRY Storage and Drying System; (2) The customer is solely responsible for meeting each of the specifications and requirements set forth in these Site Requirements, to ensure proper installation and performance for the cabinet; (3) The customer is able to meet each of these specifications and requirements; and (4) Failure of the customer to comply with these Site Requirements and any deviation from the specifications set forth herein may compromise the functionality of the cabinet, and/or may cause operational issues which will not be covered by the Medivators Inc. warranty, and hereby disclaimed by MEDIVATORS. Facility Representative: Title: Signature: Date: Email: MEDIVATORS Customer and Technical Support Toll Free: Phone: 1-800-444-4729 · FAX: 1-866-421-7696 MEDIVATORS™ , ENDODRY™ and ADVANTAGE PLUS® are trademarks and registered trademarks of Medivators Inc. Medivators Inc. 14605 28th Avenue North Minneapolis, MN 55447-4822 USA Tel: +1.763.553.3300 Fax: +1.763.553.3387 Medivators BV Sourethweg 11 6422 PC Heerlen The Netherlands Tel: +31.45.5.471.471 Fax: +31.45.5.429.595 www.medivators.com © 2015 Medivators Inc. All rights reserved. 50098-678/A Cantel Medical Asia/Pacific Pte. Ltd. 1A International Business Park #05-01 Singapore 609933 Tel: +65.6227.9698 Fax: +65.6225.6848 Medivators Inc. Beijing Representative Office Room 1801, Floor 18th, Tower A, Beijing Marriott Hotel, Office Building No. 7, Jianguomen South Avenue, Dongcheng District, Beijing 100005 China Tel: +86 10 65204039
© Copyright 2026 Paperzz