PATROL™- USM COMBINED ULTRASONIC & MW INTRUSION DETECTOR DETECTS BREAKAGE, INTRUSION AND MOTION WITHIN PROTECTED AREA PATROL-USM combined ultrasonic & microwave detector determines destruction of walls, doors, all types of glass and intrusion into the protected area. PATROL-USM with anti-mask technology detects any of the ultrasonic sensors' masking attempts. FEATURES ALGORITHM · UNPRECEDENTED PREMISES PROTECTION Dual-technology detector incorporates two physical means for determining destruction of walls, doors, all types of glass and intrusion into the protected area: registering the change in frequency of ultrasonic and microwave signals (Doppler Effect). · STABLE OPERATION IN A WIDERANGING TEMPERATURE ENVIRONMENT · INNOVATIVE METHOD FOR DETECTING ULTRASONIC AND MW SIGNALS · DIGITAL SPECTRAL ANALYSIS OF ULTRASONIC AND MW FREQUENCIES · PULSE-COUNT SELECTION (1-5) INSTRUCTION MANUALS · SEPARATE ADJUSTMENT FOR BOTH ULTRASONIC AND MW CHANNEL SENSITIVITY · BUILT- IN ANTI- MASK SYSTEM · AUTOMATIC GAIN CONTROL – ADAPTATION TO ENVIRONMENTAL CHANGES 3 4 · TAMPER PROTECTION 1 Figure 2 Wall Breakage Detection 2 Figure 3 Glass Breakage Detection For wiring, use the designated opening above the detector terminal block. 2. Connect the wires in accordance with the scheme. + 12V - RELAY TAMPER NOTE! DETECTOR INSTALLATION 1. Fix the detector vertically on solid, flat wall surface. Several detectors of this type can be installed within the protected area, at a distance of at least 3 meters from each other. The installation height is 2 – 2.5 meters. For corner installation, use knockouts located on the sloping part of the detector base. 6 7 8 Figure 1 Human Motion Detection 1. The Doppler Effect occurs when ultrasonic waves, emitted continuously by the detector, change their length and frequency when reflecting from different moving objects. 2. The Doppler Effect occurs when microwaves, emitted by the detector, change their length and frequency when reflecting from different moving objects. · HIGH RFI/EMI PROTECTION 3. To activate the alarm, both ultrasonic and microwave signals must be successively sensed within a predetermined time period. INSTALLATION LIMITATIONS 5 DETECTOR INSTALLATION OPTIONS · Do not install the detector on unstable or vibrating surfaces. · Do not install the detector close to curtains, blinds or other items that vibrate with air movement. · Do not install the detector close to air conditioners, air blast sources or above heat sources. · Do not install the detector or route power wires and alarm loops next to high voltage cables · Do not install the detector near bells, sirens or electronic sounders within the premises where soundpressure level exceeds 75dB. 9 10 DETECTOR TESTING AND ADJUSTMENT 1. Remove the front cover. 2. Set jumper W2 to "US TEST" position. 3. Connect the power. 4. Test the ultrasonic channel operation. · First of all, make sure there are no humans or animals within the protected area, windows are closed; air-conditioners, fans and other possible sources of air flow are switched off. If needed, increase the detector ultrasonic channel sensitivity using W4 jumper (Ultrasonic Sensitivity). 5. Test the microwave (MW) channel operation. 6. Replace jumper W2 to "WORK" position. · Set jumper W2 to "MW TEST" position. 7. Select the required number of pulses (1-5). · Stay for a while to make sure the green LED stops blinking, which means the detector ultrasonic channel is configured correctly! If the green LED keeps blinking, check the premises without interferences, as described above. · Walk into the detector field-of-view. The yellow LED should actively respond to your movement. If necessary, increase the detector microwave channel sensitivity, using R11 potentiometer (Microwave Sensitivity). Selectable pulse count 1, 2, 3, 4 or 5 provides users with the option of optimizing detector sensitivity to suit the environment, thus retaining reliable performance at all times. If necessary, reduce the excessive ultrasonic channel sensitivity using W4 jumper (Ultrasonic Sensitivity). · Walk into the detector field-of-view. The green LED should actively respond to your movement. 11 12 PATROL-USM DETECTION ZONE · Stay for a while to make sure the yellow LED stops blinking, which means the detector microwave (MW) channel is configured correctly! If the yellow LED keeps blinking, reduce the excessive MW channel sensitivity using the R11 potentiometer (Microwave Sensitivity). 13 17 pause between LED blinking. · To operate the detector without light indication, remove the W1 (LED) jumper. 14 15 Current consumption Detection angle:…….........170° In standby mode:……….44mА In alarm mode:………….95mА Relay output:………………….. ………..NC; 60V; 120mA; 16Ω Warm-up period:….……...2sec Tamper output:………NC; 10Ω GSN Electronic Company Ltd. warrants the product to be free from defects in materials and workmanship under condition of observance of service regulations and to be repaired or replaced under absence of mechanical damages for a limited period of five years from the date of sale. W2 – Operating mode setting 16 B. Replace jumper W3 during Maximum protected volume: …………........................ 200m³ Anti-mask alarm activation delay:………………….....35sec R11 – MW channel sensitivity adjustment The red LED blinks, indicating that pulse counting has begun. Input voltage:............9 - 16Vdc Alarm period:……...……...3sec W4 – Ultrasonic channel sensitivity adjustment A. Remove the W3 jumper. WARRANTY Anti-mask startup (boot) period:………………...30±5sec W3 – Pulse programming jumper To adjust pulse count for specific operating environments: Detection range:……………7m TECHNICAL SPECIFICATIONS TOP VIEW 8. Replace the cover - red LED will blink. At the same time, keep the detector fieldof-view clear, until the LED stops blinking – the antimasking function will then be correctly activated. Ultrasonic channel operating frequency:……………....40kHz Operating temperature range: ………………...–30ºC to +70ºC Storage temperature range: ………..............–50ºC to +85ºC RFI immunity:…………...30V/m at a frequency range 10MHz – 2GHz EMI immunity:…………50000V Microwave channel operating frequency: ....................24GHz Dimensions:………….……….... ..........105mm x 50mm x 22mm Installation height:……2 - 2.5m Weight:……………………...80g 18 19 P/N: USM0PATUSM_ENG_REV.A 20
© Copyright 2026 Paperzz