NEW! NEW! The Power to Prescribe The LifeChoice Activox POC How to Receive Your LifeChoice Activox POC 1.Request a prescription, which must be written as “LifeChoice Activox Portable Oxygen Concentrator” with the direction “Do Not Substitute” “I have the power.” 2.Contact your local DME provider or find one in your area by calling 1.800.220.0977 or visiting www.InovaLabs.com 1.800.220.0977 www.InovaLabs.com Follow Us @InovaLifeChoice Manufactured & Distributed by 3500 Comsouth Dr, Ste 100, Austin, TX 78744 Corporate Office 1.512.617.1700 © 2012 Inova Labs Inc. All rights reserved. Assembled in the USA. 200056 REV A Sept 2012 Portable Oxygen Concentrator 1.800.220.0977 www.InovaLabs.com The Ideal Oxygen Therapy for the Active Patient The LifeChoice Activox POC Features LifeChoice Activox POC Specifications Weight: 4.83 lbs. Dimensions: 9.05” w x 7.875” h x 4.38” d Mode Of Operation: Stationary/Portable Flow Control Pulse Settings: 1 LPMeq Power of Freedom and Mobility • Weighs 4.83 lbs. 2 LPMeq 3 LPMeq Sound Level at 10 Feet (3m): 41 dB 44 dB 46 dB Nominal Wave Volumes: 10 ml 20 ml 30 ml 12 Hours 6 Hours 5 Hours 3 Hours 3 Hours 2 Hours Approx. Internal Battery Duration:† • No carts or tanks required • FAA-approved Approx. External Battery Duration:† • Certified for use up to 10,000 feet Power Supply: Power of Portability Setting (LPMeq) 1 Nominal Wave Volumes (ml) 10 2 20 3 30 AC 100-240 VAC 50-60 Hz Cycles DC 12-19 VDC Battery 12-16.8 VDC Approx. Battery Recharge Time: 4 Hours Approx. External Battery Recharge Time: 3 Hours Warm-up Time: 30 Seconds Oxygen Concentration: 90% (+/- 5%) Oxygen Concentration Sensor Alarm: Less than 82% Operational Humidity Range: 15% to 95%, Non-condensing Internal Battery Run Time (hr)* 12 6 5 • Up to 15 hours of portability at 1 LPMeq† - 12 hours of internal battery - 3 hours of external battery† Operational Temp. Range: 41°F to 104°F (5°C to 40°C) Operational Altitude Max: 10,000 feet (3 km) Storage Humidity: Up to 95%, Non-condensing Storage Temp. Range: -25°F to 140°F (-32°C to 60°C) LifeChoice Activox Warranty: 3 Years (1 Year for Battery and Sieve Bed) † Based on breaths per minute. • Powered and recharged by AC/DC adapter for in-home and mobile use *Based on breaths per minute. external battery available (not included in Standard Package). †3-hour NEW! The LifeChoice Activox POC Standard Package Power of Simplicity and Ease of Use • Powers on/off and adjusts dosing with touch of a button • Mute feature to disable audible alarms • Quiet — 41 dB at 1 LPMeq Power of 24/7 Therapy — Day or Night • Automatically adjusts patient therapy based on oxygen demand • PULSE-WAVETM delivers oxygen continuously during inspiration • Breath detection is more sensitive during sleep • A temporary stationary treatment option that also functions as a lightweight POC The Package Contains the Following: • LifeChoice Activox POC • 4-Way Carrying Case (Backpack, Shoulder Strap, Waist Pack, Briefcase) • • • • • 12-Hour Internal Battery at 1 LPMeq* AC/DC Adapter/Charger 7-Foot Nasal Cannula Accessory Bag Standard 3-Year Limited Warranty Power That’s Affordable • A non-delivery, service-free oxygen therapy for DME providers • Medicare reimbursed and covered by most private insurance plans (1 Year for Battery and Sieve Bed) *3-hour external battery available (not included in Standard Package). NEW! 1.800.220.0977 www.InovaLabs.com A Constant Source of Portable Oxygen Pulse Settings • 1, 2, 3 LPMeq • 10 ml per LPMeq @ 15 bpm Internal/External Battery Gauge • 25% increments • Estimate to the nearest interval Power On/Off Unique PULSE-WAVE Technology TM Activox PULSE-WAVE 3 LPMeq Schematic POC PULSE-WAVE Delivery Active Mode 25 BPM Inhale = 0.5 Liters Exhale = 0.5 Liters PULSE-WAVE Utilized 30ml 0.9 Seconds 1.5 2.4 Seconds Seconds Sleep Mode 15 BPM Inhale = 0.5 Liters Exhale = 0.5 Liters PULSE-WAVE Utilized 30ml Auto Mode Mute Alarm Breath Alarm • No breath activity • Low oxygen output • Device malfunction Auto Mode Settings Active - High Mode Sleep - Low Mode Breath per Minute High Low Trigger Sensitivity Baseline Greater Sensitivity to Baseline PULSE -WAVE Delivery Yes 4.0 Seconds 1.4 Seconds 4.0 Seconds 2.6 Seconds • Oxygen is delivered continuously during inspiration so what is delivered is received • Side effects from retrograde flow are minimized Traditional Continuous Flow 3 LPMeq Schematic Continuous FiO2 = 26% Yes 25 BPM Inhale = 0.5 Liters Wasted 85.7 ml Continuous Flow Utilized 24.5 ml 0.9 Seconds Exhale = 0.5 Liters 1.5 2.4 Seconds Seconds NEW! 1.800.220.0977 www.InovaLabs.com
© Copyright 2026 Paperzz