NEW! “I have the power.”

NEW!
NEW!
The Power to Prescribe
The LifeChoice Activox POC
How to Receive Your
LifeChoice Activox POC
1.Request a prescription, which must be
written as “LifeChoice Activox Portable
Oxygen Concentrator” with the
direction “Do Not Substitute”
“I have
the
power.”
2.Contact your local DME provider
or find one in your area by calling
1.800.220.0977 or visiting
www.InovaLabs.com
1.800.220.0977
www.InovaLabs.com
Follow Us
@InovaLifeChoice
Manufactured & Distributed by
3500 Comsouth Dr, Ste 100, Austin, TX 78744
Corporate Office 1.512.617.1700
© 2012 Inova Labs Inc. All rights reserved. Assembled in the USA. 200056 REV A Sept 2012
Portable Oxygen Concentrator
1.800.220.0977
www.InovaLabs.com
The Ideal Oxygen Therapy
for the Active Patient
The LifeChoice Activox POC Features
LifeChoice Activox POC
Specifications
Weight:
4.83 lbs.
Dimensions:
9.05” w x 7.875” h x 4.38” d
Mode Of Operation:
Stationary/Portable
Flow Control Pulse Settings: 1 LPMeq
Power of Freedom and Mobility
• Weighs 4.83 lbs.
2 LPMeq
3 LPMeq
Sound Level at 10 Feet (3m):
41 dB
44 dB
46 dB
Nominal Wave Volumes:
10 ml
20 ml
30 ml
12 Hours
6 Hours
5 Hours
3 Hours
3 Hours
2 Hours
Approx. Internal
Battery Duration:†
• No carts or tanks required
• FAA-approved
Approx. External
Battery Duration:†
• Certified for use up to 10,000 feet
Power Supply:
Power of Portability
Setting (LPMeq)
1
Nominal Wave
Volumes (ml)
10
2
20
3
30
AC 100-240 VAC
50-60 Hz Cycles
DC 12-19 VDC
Battery 12-16.8 VDC
Approx. Battery
Recharge Time:
4 Hours
Approx. External Battery
Recharge Time:
3 Hours
Warm-up Time:
30 Seconds
Oxygen Concentration:
90% (+/- 5%)
Oxygen Concentration
Sensor Alarm:
Less than 82%
Operational Humidity Range: 15% to 95%, Non-condensing
Internal Battery
Run Time (hr)*
12
6
5
• Up to 15 hours of portability at 1 LPMeq†
- 12 hours of internal battery
- 3 hours of external battery†
Operational Temp. Range:
41°F to 104°F (5°C to 40°C)
Operational Altitude Max:
10,000 feet (3 km)
Storage Humidity:
Up to 95%, Non-condensing
Storage Temp. Range:
-25°F to 140°F (-32°C to 60°C)
LifeChoice Activox Warranty: 3 Years (1 Year for Battery
and Sieve Bed)
†
Based on breaths per minute.
• Powered and recharged by AC/DC adapter
for in-home and mobile use
*Based
on breaths per minute.
external battery available
(not included in Standard Package).
†3-hour
NEW!
The LifeChoice
Activox POC Standard
Package
Power of Simplicity and Ease of Use
• Powers on/off and adjusts dosing with
touch of a button
• Mute feature to disable audible alarms
• Quiet — 41 dB at 1 LPMeq
Power of 24/7 Therapy —
Day or Night
• Automatically adjusts patient therapy
based on oxygen demand
• PULSE-WAVETM delivers oxygen
continuously during inspiration
• Breath detection is more sensitive
during sleep
• A temporary stationary treatment option
that also functions as a lightweight POC
The Package Contains the Following:
• LifeChoice Activox POC
• 4-Way Carrying Case
(Backpack, Shoulder Strap, Waist Pack, Briefcase)
•
•
•
•
•
12-Hour Internal Battery at 1 LPMeq*
AC/DC Adapter/Charger
7-Foot Nasal Cannula
Accessory Bag
Standard 3-Year Limited Warranty
Power That’s Affordable
• A non-delivery, service-free oxygen
therapy for DME providers
• Medicare reimbursed and covered by
most private insurance plans
(1 Year for Battery and Sieve Bed)
*3-hour external battery available (not included in
Standard Package).
NEW!
1.800.220.0977
www.InovaLabs.com
A Constant Source of
Portable Oxygen
Pulse Settings
• 1, 2, 3 LPMeq
• 10 ml per LPMeq @ 15 bpm
Internal/External
Battery Gauge
• 25% increments
• Estimate to the nearest
interval
Power
On/Off
Unique PULSE-WAVE
Technology
TM
Activox PULSE-WAVE 3 LPMeq Schematic
POC PULSE-WAVE Delivery
Active Mode
25 BPM
Inhale =
0.5 Liters
Exhale = 0.5 Liters
PULSE-WAVE
Utilized 30ml
0.9
Seconds
1.5
2.4 Seconds
Seconds
Sleep Mode
15 BPM
Inhale =
0.5 Liters
Exhale = 0.5 Liters
PULSE-WAVE Utilized 30ml
Auto Mode
Mute Alarm
Breath Alarm
• No breath activity
• Low oxygen output
• Device malfunction
Auto Mode Settings
Active - High Mode
Sleep - Low Mode
Breath per Minute
High
Low
Trigger
Sensitivity
Baseline
Greater Sensitivity
to Baseline
PULSE -WAVE Delivery
Yes
4.0
Seconds
1.4
Seconds
4.0
Seconds
2.6
Seconds
• Oxygen is delivered continuously
during inspiration so what is
delivered is received
• Side effects from retrograde flow
are minimized
Traditional Continuous Flow 3 LPMeq Schematic
Continuous FiO2 = 26%
Yes
25 BPM
Inhale = 0.5 Liters Wasted 85.7 ml
Continuous Flow
Utilized 24.5 ml
0.9
Seconds
Exhale = 0.5 Liters
1.5
2.4
Seconds
Seconds
NEW!
1.800.220.0977
www.InovaLabs.com