3M™ Visionair™ Supplied Air Respirator System

3M™ Powered & Supplied Air Respirators
3M™ Visionair™ Supplied Air
Respirator System
Care and Maintenance
The 3M Visionair Supplied Air Respirator System is a waist-mounted, adjustable regulator continuous flow
respiratory protection device.
To maintain protection levels, optimise the effective lifetime of the system and avoid the additional
cost of replacement, it is extremely important to carry out regular checks and maintenance on
Powered and Supplied Air Respirators.
Before Use
After Use
Regulator
•Inspect Regulator assembly for cracks or loose
connectors
•Inspect Breathing Tube – ensure it is free from splits or
holes. Replace if necessary
•Inspect Belt – ensure it is free from splits or tears and the
buckle is undamaged
•Examine the 3M Compressed Air Supply Tube for
damage
•Clean with cloth dampened with a mild solution of water
and liquid household soap
Headtop
•Inspect Comfort Band. Remove and replace if necessary
•Inspect Face Seal and Visor. Ensure they are undamaged
(free from splits or tears). Replace if necessary
•Ensure Pivot Nuts are secure
•Replace Visor Peel-Off (if used)
Every 6 Months
Replace all damaged parts immediately to
ensure correct levels of protection
•Disinfect with 3M™ 105 Wipes •Store in a dry, clean area / locker away from direct
sunlight, high temperatures and solvents
Monthly
•Carry out all the ‘Before Use’ inspections and create
record of this monthly check for the regulator
•Replace filter
8
1
2
10
8
4
1
3
6
2
7
10
4
3
6
7
16
15
17mm
5/16”
20
21 22 22A
3M Part Number
Visionair 500HV without coupling, high volume spray gun attachment included
300-07-81P
1
Brow seal
3002319-0P1x4
2
Face seal
2002318-0P3x4
3
Foam face and brow seal
16
2002346-0P1x4
15
17mm
4
Acetate visors (pack 5) and visor stud
4
5/16”
Polycarbonate
visors (pack 5) and visor stud
6
Peel-off visors
7
Breathing hose assembly
8
Comfort bands
10
Head Cape / Overhood
300-07-42P
15
Filter elements
530-11-56P
16
Waistbelt
301-00-62P5
20
Y piece and spray gun hose
312-00-87P
21
Rectus ‘25’ 1/4" BSP male
530-12-52P3
22
Broomwade ‘Instantair’ 1/4" BSP male
741019-00P3
22A
CEJN ‘342’ 1/4" BSP male
530-12-53P3
Waistbelt regulator assembly excluding coupling, Y piece and hose
302-00-90P
Spare headtop and tube
310-00-84P
310-03-74P5
310-23-74P20x4
312-00-88P
310-14-74Px5
Ordering Consumables, Repair Parts and Accessories
To request a quote or place an order for these items, please
contact your 3M Approved Distributor.
Occupational Health & Environmental Safety Group
3M Ireland Limited
3M United Kingdom PLC
3M Centre,
Cain Road, Bracknell
Berkshire RG12 8HT
Tel: 0870 60 800 60
www.3M.com/uk/ohes
310-01-75P
21 22 22A
20
The Iveagh Building
The Park
Carrickmines
Dublin 18
Tel: 1 800 320 500
Further Information and Advice
If you require additional guidance on the Care and
Maintenance of your 3M Powered and Supplied Air Equipment,
please contact the Helpline or your local 3M representative.
3M Health and Safety Helpline
0870 60 800 60 (UK)
1 800 320 500 (Ireland)
Please recycle.
Printed in the United Kingdom.
© 3M 2009. All rights reserved.