A local extractor with friction joints for worksites where great flexibility is required. The TERFU is a local extractor with friction joints designed for use in workplaces where great flexibility is required e.g. laboratories, production environments, and lighter industrial applications. Simple, easy function. The friction joints have a large frictional diameter and are supported with ball bearings. The degree of friction is easily adjusted with a one-hand knob. Adapted support springs balance out the weight of the arm. All arms are equipped with a 360 degree rotational swivel mounted in place. An air tight damper is fitted as standard. Always easy to select the right product. Terfu is available in two versions: – Standard version. Suitable for evacuation of most types of airborne contaminants. – PP version. Most suitable for evacuation of highly corrosive contaminants in high concentrations. All sizes are suitable for table mounting, ceiling mounting and wall mounting. The same suction arm is used for suspended mounting from ceilings and walls. Ceiling and wall brackets both consist of an anodized square aluminum profile for durable surfaces and high stability. All ceiling brackets are available in eight standard lengths up to 80 inches. Longer lengths can be supplied by special orders. To further simplify your mounting and provide a cleaner look, an MTI CT escutcheon plate can be used to cover rough cut holes in the false ceiling. The TERFU system is design protected with several patents- and design protections pending. The Movex range also includes fans, accessories, automatic controls and filters suitable for local extraction. LOCAL EXTRACTION Pure advantages R TERFU Model Standard version of Terfu with polypropylene joints and anodized aluminum tubes. The standard version of Terfu is suitable for evacuation of most types of airborne contaminants from laboratories, schools, hospitals, pharmaceutical industry, nail salons and light industrial applications. Polypropylene(PP)version of Terfu with joints and tubes in recyclable PP. All metal parts that come in contact with the airstream are made from acid resistant stainless steel (SS 2343). The PP version of Terfu is primarily used for evacuation of extremely corrosive contaminants in high concentrations for certain laboratories, pharmaceutical and chemical industries. When using a ceiling mounted PP extractor, recommend using an MTI ceiling bracket with internal and external powder coating. TERFU Maximum flexibility Terfu joint. The large frictional diameter together with the single grip adjusting knob provide a rigid, stable joint with a smooth easily adjustable function without requiring the application of excessive force or tools. The joint has reinforced side pieces. Ball bearings that isolate the adjusted friction level allow the arm to move up and down without locking the joint or loosing stability and function. Appealing stable brackets All Terfu extractors have a standard full-swivel that allows 360° of rotation without the need for special sleeves or double wall mountings. Both ceiling and wall brackets consist of a special anodized aluminum profile that provide an appealing, functional installation. The ceiling bracket also acts as the extraction channel, thus avoiding the need for expensive external channeling and additional holes in the finished ceiling. Installation is simple and stable. The ceiling bracket is available in eight standard lengths from 10 to 80 inches. Lengths greater that 80 inches can be supplied to order. The ceiling mount can be provided with internal epoxy coating for use in aggressive environments. MV 1000-75 MV 1300-75 MV 1500-75 MV 2000-75 MVS 1500-75 MVS 2000-75 Size (inch) A B PP PP PP PP PP 16 22 30 40 30 40 Table mount Designation MB 1000-75 MB 1300-75 MB 1500-75 12 18 18 26 18 26 Size (inch) A B PP PP PP 16 22 30 12 18 18 40 51 60 80 60 80 3 3 3 3 3 3 5.0 5.7 6.0 7.1 6.0 7.1 Total length C Weight lb 40 51 60 80 60 80 3 3 3 3 3 3 9.7 10.4 10.7 11.8 10.7 11.8 Total length C Weight lb 40 51 60 3 3 3 5.0 5.7 6.0 Model with gas spring MTS* 85/8 21/2 Wall mount Designation 12 18 18 26 18 26 37/8 10” 16 22 30 40 30 40 C 37/8 8” PP PP PP PP PP Total length Weight lb 10” MT 1000-75 MT 1300-75 MT 1500-75 MT 2000-75 MTS 1500-75 MTS 2000-75 Size (inch) A B Terfu extractors with designation MV always include a wall bracket 31/8 10” Ceiling mount Designation 37/8 Pressure drop diagram measured in accordance with Ø 3” 3 joints ISO-standard 5167-1. The noise level is measured in 2.0 accordance with ISO-standard 56 dB(A) 1.6 1.2 3741. 51 0.8 0.4 36 20 40 39 60 44 48 80 100 120 140 160 Air flow cfm Project planning advice 20 Typical values Terfu 70-85 cfm 70-85 cfm MT 1300 72-84 MT 1500 76-88 MT 2000 84-96 Recommended side Designation displacement in MT 1000 relation to workplace MT 1300 S inch 12-24 16-24 MT 1500 20-32 MT 2000 28-40 36” Range at recommended mounting height The following mounting heights and side displacements are recommended for optimization of evacuation MT 2000 20 40 60 20 64-76 MT 1000 MT 1000 MT 1300 H inch MT 1500 Designation MT 2000 Recommended mounting height MT 2000 MT 1500 MT 1300 MT 1000 80 Laboratory Schools 80 inch. 60 Air flow 60 40 Function 40 100 inch. Static pressure drop (in/wg) The static pressure drop is 3.2 2.8 2.4 80 inch. 36” MT 1500 MT 1300 MT1000 Working radius Maximum radius The MTI and MTF ceiling bracket 20150911 The ceiling bracket functions as a simple and stable duct for outgoing air, avoiding the need for expensive ducting and additional holes through false ceilings. On request, the MTI can be supplied in lengths exceeding 80 inches. 6 0.12 MTI 0.08 7 7/8 Ø3 7/8 Dimensions Weight L (inch) (lb) 40 9.3 0.16 L Standard MTF Ø 3/8x4 7 7/16 Dimensions Weight L (inch) (lb) 10 6.9 20 8.4 30 9.9 40 11.4 50 12.9 60 14.4 70 15.9 80 17.4 Static pressure drop (in/wg) Standard MTI 250 MTI 500 MTI 750 MTI 1000 MTI 1250 MTI 1500 MTI 1750 MTI 2000 0.04 40 80 120 160 Air flow cfm 4 3/16 40” 7 7/8 3/16 The ceiling brackets can be supplied with an epoxy-coated exterior in all lengths. For aggressive environments, we recommend epoxy coating on the interior and exterior. 2 7 7/16 1/2 Ceiling bracket, for fitting through beams. The attachment plate is adjustable for the entire length of the aluminum profile. Ø 3/8x4 If required, the aluminum profile can be cut during fitting. Ø3 7/8 The MTI CT escutcheon plate 4 3/16 Weight (oz) 1.75 4 3/4 Standard MTI CT Ø 7/32 (4X) MVK wall bracket 4 3/4 Ø 7/16 (4X) Ø 3 7/8 5 5/8 Standard MBF 4 1/8 7 7/8 6 7/8 Hoods Weight (lb) 1.6 Ø3 12 METAL HOOD MM 250-75 MMB 250-75 equipped with light. Material Standard, Aluminum Weight, 11.8 oz Temp. range -5°F to +176°F 12 5” 12 1/2 DOME HOOD MK 350-75 (PP) Material Standard, PETG PP, Polypropylene Weight, 15.9 oz Temp. range -5°F to +176°F Material description Friction joint Ball-bearing supported adjustable friction joints in polypropylene (PP) with guide ring of low-friction treated rubber. Support springs and other attachment details in zinc plated steel or stainless steel. Tube Made from thin-wall anodized aluminum, alternatively from polypropylene. Air-tight damper supplied as standard. Fan and filter Connects to a separate fan, central extractor system or filter. Recommended operating temperature -5°F to +176°F. Ø3 4 Ø 14 Ø 10 Ø3 3 11 SUCTION NOZZLE MES 300-75 (PP) Material Standard, Aluminum PP, Polypropylene Weight, 5.6 oz Temp. range -5°F to +176°F 15 3/4 8 Ø3 Ø3 9 Flexible bracket for attaching to a table-top or shelving. Supplied complete with two clamps. 2 1/2 Weight (lb) 4.7 3 13/16 1/8 MBF flexible table bracket Wall brackets can be special ordered in custom horizontal and vertical lengths. Standard MVK 5 7/8 Escutcheon plate, used with the MTI ceiling bracket for stabilization and to cover the rough cut in false ceilings. 14 SQUARE HOOD MSH 350-75 Material Standard, PETG Weight, 17.1 oz Temp. range -5°F to +176°F Delivery 6 8 3/4 FLAT SCREEN HOOD MPH 300-75 (PP) Material Standard, PETG PP, Polypropylene Weight, 12.9 oz Temp. range -5°F to +176°F Ceiling/ Supplied assembled, excluding hood. The Wall ceiling or wall brackets should be ordered separately. MET Table- Supplied assembled, with attachment plate for table MEB fitting, excluding hood. The MBF flexible table bracket should be ordered separately. 104 Commerce Drive, Northampton, PA 18067, USA Phone: 610 440-0478, Fax: 610 440-0480 www.movexinc.com [email protected]
© Copyright 2026 Paperzz