400 Series Tilt-Wash Double-Hung Full-Frame Windows

T ilt-Wash Double-Hung W indows
Contents
Tilt-Wash Double-Hung Windows
Basic Unit Details - Tilt-Wash Double-Hung ....................................3-2
Basic Unit Details - Double-Hung Picture and Transom Window .......3-3
Options / Accessories
Andersen® Grilles .......................................................................3-4
Stools and Extension Jambs for Tilt-Wash Basic Units .................3-6
Stools and Extension Jambs for Double-Hung Picture Units ........3-7
Stools and Extension Jambs for Double-Hung Transom Units ......3-8
Combination Unit .......................................................................3-8
Joining Details ................................................................................3-9
• Slim frame and sash profile maximize
the field of view
• Excellent for creating window
combinations
• Easy to clean.
• Low maintenance.
R E V. 0 3 / 0 5
Anchoring Methods .......................................................................3-12
Suggested Product Applications ....................................................3-13
A R C H I T E C T U R A L
D E T A I L
F I L E
3-1
T ilt-Wash Double-Hung W indows
Basic Unit Details - Tilt-Wash Double-Hung
Basic Unit
1-5/16" (33)
Scale 3" = 1'-0" (1:4)
4-1/2" (114)
Lower sash in
open position
3/8" (10)
2-7/16" (62)
Optional
Andersen®
insect
screen
High-Performance™
insulating glass
Unit Dimension Height
1-5/16"
(33)
Clear Opening Height
Rough Opening Height
Head
1-1/2" (38)
Check Rail
Optional Andersen® stool
1-1/2" (38)
5/8" (16)
3-9/16"
(91)
2-7/16" (62)
1/2" (13)
3/8" (10)
Fibrex™ material sill
Sill
Vertical Section
3-5/16"
(84)
3-5/16"
(84)
Jamb
Jamb
Lower
sash
4-1/2"
(114)
Upper
sash
1-5/16"
(33)
1-7/8"
(37)
1/4" (6)
Clear Opening Width
Unit Dimension Width
1-7/8"
(37)
Optional Andersen®
insect screen
1/4" (6)
Rough Opening Width
Horizontal Section
3-2
A R C H I T E C T U R A L
D E T A I L
F I L E
R E V. 0 3 / 0 5
T ilt-Wash Double-Hung W indows
Basic Unit Details - Double-Hung Picture (DHP) and Transom (DHT) Window
Picture Unit
Transom Unit
Scale 3" = 1'-0" (1:4)
Scale 3" = 1'-0" (1:4)
1-5/16" (33)
4-1/2" (114)
1-5/16" (33)
4-1/2" (114)
Clad
aluminum
1/4" (6)
3/8" (10)
2-3/8" (60)
1-1/2" (38)
Glass Height
Optional
Andersen®
stool
Unit Dimension Height
Rough Opening Height
Glass Height
Unit Dimension Height
Rough Opening Height
2-7/16" (62)
5/8" (16)
2-7/16" (62)
2-15/16" (75)
1/2" (13)
3/8" (10)
1/4" (6)
Fibrex™ material sill
Clad aluminum
Vertical Section
Vertical Section
4-1/2"
(114)
4-1/2"
(114)
1-5/16"
(33)
1-5/16"
(33)
2-7/16" (62)
1/4" (6)
3-5/16" (84)
2-7/16" (62)
Glass Width
Unit Dimension Width
1/4" (6)
1/4" (6)
1/4" (6)
Horizontal Section
Horizontal Section
A R C H I T E C T U R A L
3-5/16" (84)
Rough Opening Width
Rough Opening Width
R E V. 0 3 / 0 5
Glass Width
Unit Dimension Width
D E T A I L
F I L E
3-3
T ilt-Wash Double-Hung W indows
Options / Accessories
Exterior Color
Frenchwood® Patio Door Sidelights & Transoms
Frenchwood® Hinged Outswing
Frenchwood® Hinged Inswing
Andersen®
400 Series Doors
Frenchwood® Gliding
Gothic
Circle & Oval
Elliptical
Flexiframe®
Springline™
Arch
Circle Top™ & Quarter Round
Tilt-Wash Picture Window
Tilt-Wash Double-Hung & Transom
Woodwright® Springline™ Single-Hung
Woodwright® Picture Window
Gliding Window
Casement & Awning
Please check with Andersen
for availability
Casement Picture Window
Available only with 3/8" glass through
the Andersen Divided Light program
Woodwright® Double-Hung & Transom
Available now
Woodwright® Archtop & Unequal Leg Archtop
Andersen®
400 Series Windows
200 Series Narroline® Double-Hung & Transom
Andersen ® Divided Light Grilles
White
Sandtone
Terratone®
Forest Green
Width
3/4"
7/8"
1-1/8"
Type
2-1/4"
With Spacer
Without Spacer
Interior
Maple
Oak
Prefinished
Pine
Colonial
Modified Colonial
Modified Col W/Check Rail
Prairie A
Patterns
Short Fractional
Short Fractional W/Check Rail
Tall Fractional
Tall Fractional W/Check Rail
Victorian
Renaissance
Sunburst
Specified Equal Light
Custom
Glass
HP/HP Tempered
HP Sun/HP Sun Temp
3/8" Low-E/Temp
Single-Pane Impact
3-4
A R C H I T E C T U R A L
D E T A I L
F I L E
R E V. 0 3 / 0 5
T ilt-Wash Double-Hung W indows
Options / Accessories
400 Series Grille Options
Removable
Interior
Andersen® Divided Light Grille
Permanent Exterior
Removable Interior
Andersen® Divided Light Grille
Permanent Exterior
Permanent Interior
Andersen® Divided Light Grille
Permanent Exterior
Permanent Interior
with Spacer
Andersen® Finelight™
Grilles-Between-the-Glass
Grille Profiles • Scale = Full • Dimensions include thickness of tape.
Permanent Exterior Fibrex® Material Grille Profiles (chamfer profile). Also used for pre-finished interior, except 400 Series Woodwright® double-hung windows.
5/16"
7/16"
1/2"
1-13/16"
45˚
45˚
45˚
35˚
5/16"
5/16"
5/16"
7/8"
3/4"
5/16"
1-1/8"
2-1/4"
Permanent Interior Wood Grille Profiles (chamfer profile).
The Fibrex® material exterior grille is used when a permanent prefinished grille is specified, except with 400 Series Woodwright® double-hung windows.
5/16"
3/8"
3/8"
53˚
1-13/16"
1/2"
7/16"
3/8"
53˚
7/16"
35˚
53˚
3/32"
7/8"
3/4"
1-1/8"
Removable Interior Wood Grille Profile (roman ogee profile).
2-1/4"
Removable Interior Wood Grille Profile (Chamfer profile).
400 Series Woodwright® double-hung windows only.
1/2"
7/16"
3/4"
3/4"
1-1/8"
7/8"
7/8"
1-1/8"
Permanent Full Divided Light Grille spacer location.
1/2"
1/2"
1/8"
1/2"
1/2"
5/16"
3/16"
1/2"
1/8"
Andersen® Finelight™ Grilles-Between-the-Glass.
R E V. 0 3 / 0 5
3/8"
1/2"
3/4"
1"
A R C H I T E C T U R A L
D E T A I L
F I L E
3-5
T ilt-Wash Double-Hung W indows
Options / Accessories
Stools and Extension Jambs for Tilt-Wash Basic Units
Scale 3" = 1'-0" (1:4)
7-1/8" (181)
6-9/16" (167)
5-1/4" (133)
4-9/16" (116)
Extension Jambs
5-1/4" (133)
Wall
11/16"
(17)
3/8" (10)
23/32"
(18)
6-9/16" (167)
Wall
2-1/32" (52)
Head
7-1/8" (181)
Wall
2-19/32" (66)
Jamb
Optional
factory applied
DP upgrade sill stop
Stools
Optional
Andersen®
stool
For wall
thicknesses
up to
5-1/4" (133)
23/32"
(18)
2-15/16"
(75)
For wall
thicknesses
up to
7-1/8" (181)
1-27/32"
(47)
3-27/32" (98)
Sill
4-9/16" (116)
Extension jambs available for 5-1/4" (133), 6-9/16" (167)
or 7-1/8" (181) wall thickness. Stools are available for wall
thicknesses up to 5-1/4" (133) or 7-1/8" (181) thick. Other wall
dimensions can be accommodated with stool and extension jamb
modification. Extension jambs are predrilled for easy application
(except for 5-1/4" (133) sizes).
5-1/4" (133)
6-9/16" (167)
7-1/8" (181)
Vertical Section
3-6
A R C H I T E C T U R A L
D E T A I L
F I L E
R E V. 0 3 / 0 5
T ilt-Wash Double-Hung W indows
Options / Accessories
Stools and Extension Jambs for Double-Hung Picture Units (DHP)
Scale 3" = 1'-0" (1:4)
7-1/8" (181)
6-9/16" (167)
5-1/4" (133)
4-9/16" (116)
Extension Jambs
5-1/4" (133)
Wall
11/16"
(17)
3/8" (10)
23/32"
(18)
6-9/16" (167)
Wall
2-1/32" (52)
Head
7-1/8" (181)
Wall
2-19/32" (66)
Jamb
Stools
Optional
Andersen®
stool
For wall
thicknesses
up to
5-1/4" (133)
23/32"
(18)
2-15/16"
(75)
1-27/32"
(47)
For wall
thicknesses
up to
7-1/8" (181)
3-27/32" (98)
Sill
4-9/16" (116)
5-1/4" (133)
6-9/16" (167)
7-1/8" (181)
Extension jambs available for 5-1/4" (133), 6-9/16" (167)
or 7-1/8" (181) wall thickness. Stools are available for wall
thicknesses up to 5-1/4" (133) or 7-1/8" (181) thick. Other wall
dimensions can be accommodated with stool and extension jamb
modification. Extension jambs are predrilled for easy application
(except for 5-1/4" (133) sizes).
Vertical Section
R E V. 0 3 / 0 5
A R C H I T E C T U R A L
D E T A I L
F I L E
3-7
T ilt-Wash Double-Hung W indows
Options / Accessories
Combination Unit Scale 3" = 1'-0" (1:4)
Stools and Extension Jambs for Double-Hung Transom
Units (DHT) Scale 3" = 1'-0" (1:4)
1-5/16" (33)
4-1/2" (114)
7-1/8" (181)
6-9/16" (167)
5-1/4" (133)
4-9/16" (116)
Hinge
member
Combination
unit for
triple glazing
Extension Jambs
Head
5-1/4" (133)
Wall
3/8"
(10)
11/16"
(17)
Stationary
upper storm
panel
23/32"
(18)
6-9/16" (167)
Wall
2-1/32" (52)
Head
Check Rail
Insect
screen
Optional
Andersen®
stool
7-1/8" (181)
Wall
2-19/32" (66)
Operating
lower panel
Extension jambs available for 5-1/4"
(133), 6-9/16" (167) or 7-1/8" (181)
wall thickness. Stools are available for
wall thicknesses up to 5-1/4" (133)
or 7-1/8" (181) thick. Other wall
dimensions can be accommodated
with stool and extension jamb
modification. Extension jambs are
predrilled for easy application (except
for 5-1/4" (133) sizes).
Jamb
Sill
Vertical Section
Stools
Optional
Andersen®
stool
For wall
thicknesses
up to
5-1/4" (133)
Combination unit
23/32"
(18)
1-27/32"
(47)
For wall
thicknesses
up to
7-1/8" (181)
Jamb
Horizontal Section
3-27/32" (98)
At Head- Outer frame of combination unit fits into head jamb
window unit. Hinges fastened to the exterior of the head jamb
enables easy cleaning of the sill.
At Check Rail - Strong aluminum check rail with stationary
storm panel, insect screen and lower operating panel.
At Jamb - Storm panel operates on smooth vinyl channels
within the side stile frame members. Insect screen is located
outside the storm panel.
At Sill - Combination unit frame bottom rail with insect screen
in place and operating lower panel in closed position.
Complete unit furnished by Andersen, not applied to window
unit.
Sill
4-9/16" (116)
5-1/4" (133)
6-9/16" (167)
7-1/8" (181)
Vertical Section
3-8
A R C H I T E C T U R A L
D E T A I L
F I L E
R E V. 0 3 / 0 5
T ilt-Wash Double-Hung W indows
Joining Details
Tilt-Wash Double-Hung to Tilt-Wash Double-Hung
Double-Hung Picture to Double-Hung Picture
Scale 3" = 1'-0" (1:4)
Scale 3" = 1'-0" (1:4)
Optional
Andersen®
interior trim
Unit Dimension Width
Unit Dimension Width
1/8" (3)
(Ref.)
Optional Andersen®
exterior vinyl
trim strip set
in continuous
bead of sealant
each side
Optional
Andersen®
interior trim
Optional
Andersen®
exterior vinyl
trim strip set
in continuous
bead of sealant
each side
Unit Dimension Width
Unit Dimension Width
1/8" (3)
(Ref.)
Non-Reinforced Mullion
Non-Reinforced Mullion
2-7/8" (73)
2-7/8" (73)
Optional
Andersen®
interior trim
Optional
Andersen®
interior trim
Optional
Andersen®
steel
reinforced join
Optional
Andersen®
steel
reinforced join
Unit Dimension Width
Unit Dimension Width
3/16" (5)
Optional Andersen®
exterior vinyl
trim strip set
in continuous
bead of sealant
each side
Steel Reinforced Mullion
Unit Dimension Width
2" (51)
Unit Dimension Width
Unit Dimension Width
Unit Dimension Width
Optional
Andersen®
exterior vinyl
trim strip set
in continuous
bead of sealant
each side
3/16" (5)
Steel Reinforced Mullion
Interior trim
by others
Interior trim
by others
Structural
support
by others
Structural
support
by others
Optional
Andersen®
2" support
mullion
wood filler
Optional
Andersen®
2" support
mullion
wood filler
Optional
Andersen®
2" support
trim strip set
in continuous
bead of
sealant each
side
Optional
Andersen® 2"
support mullion
trimstrip set in
continuous bead
of sealant each
side
Unit Dimension Width
Support Mullion
2" (51)
Unit Dimension Width
Support Mullion
Joining Compatibility
Many Andersen® units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and
joining methods can be viewed in the Andersen® Product Guide for Professionals, in Andersen Window Studio® software, and by visiting www.andersenwindows.com.
Combination designs should always be checked for design pressure performance requirements to ensure the appropriate joining method is specified.
R E V. 0 3 / 0 6
A R C H I T E C T U R A L
D E T A I L
F I L E
3-9
T ilt-Wash Double-Hung W indows
Joining Details
Double-Hung Transom to Double-Hung Transom
Scale 3" = 1'-0" (1:4)
Interior trim
by others
Unit Dimension Width
Unit Dimension Width
Joining Compatibilty
Optional Andersen®
exterior vinyl
trim strip set
in continuous
bead of sealant
each side
Many Andersen® units are designed to be joined with other
Andersen units in a variety of non-reinforced and reinforced
combinations. Other combination types and joining
methods can be viewed in the Andersen® Product Guide for
Professionals, in Andersen Window Studio® software, and by
visiting www.andersenwindows.com. Combination designs
should always be checked for design pressure performance
requirements to ensure the appropriate joining method is
specified.
1/8" (3)
(Ref.)
Non-Reinforced Mullion
2-7/8" (73)
Optional
Andersen®
interior trim
Optional
Andersen®
steel
reinforced join
Unit Dimension Width
Unit Dimension Width
3/16" (5)
Optional Andersen®
exterior vinyl
trim strip set
in continuous
bead of sealant
each side
Steel Reinforced Mullion
Interior trin
by others
Structural
support
by others
Optional
Andersen®
2" support
mullion
wood filler
Unit Dim.
2" (51)
Unit Dim.
Optional
Andersen®
2" support
mullion
trim strip set
in continuous
bead of
sealant each
side
Support Mullion
3-10
A R C H I T E C T U R A L
D E T A I L
F I L E
R E V. 0 3 / 0 5
T ilt-Wash Double-Hung W indows
Joining Details
Double-Hung Transom (DHT) over Tilt-Wash Double-Hung
Scale 3" = 1'-0" (1:4)
1-5/16" (33)
4-1/2" (114)
3/8" (10)
Unit Dimension Height
2-3/8" (60)
Transom
Optional
Andersen®
trim
2-15/16" (75)
0"
1/16" (2)
2-7/16" (62)
Unit Dimension Height
Tilt-Wash Unit Dimension + Double-Hung Transom Unit Dimension = Overall Unit Dimension
Rough Opening Height
1/8"
(3)
Head
3-9/16" (91)
5/8" (16)
2-7/16" (62)
1/2" (13)
3/8" (10)
Sill
Vertical Section
R E V. 0 3 / 0 5
A R C H I T E C T U R A L
D E T A I L
F I L E
3-11
T ilt-Wash Double-Hung W indows
Anchoring Methods
Installation Flange
Standard Installation Flange Reversed
Scale 3" = 1'-0" (1:4)
Scale 3" = 1'-0" (1:4)
Standard application of installation flanges as shipped from Andersen to be
used for 4-1/2" (105) wall construction. Tilt-wash double-hung window is
secured in the opening by using threaded fasteners through the installation
flange.
Regular installation flange in reverse position to accommodate a 4-1/8" (105) wall.
1/2"
(13)
4 1/2"
(114)
4-1/8"
(105)
3 1/2"
(89)
1/2"
(13)
Jamb Clip
Threaded Masonr y Fastener / Expansion Sleeve
Scale 3" = 1'-0" (1:4)
Scale 3" = 1'-0" (1:4)
Double-hung window unit secured in opening by others
using Andersen® 302 stainless steel sheet metal jamb
clips and stainless steel screws. Bend the jamb clips to
secure unit fit in opening. Installation flange can be cut,
or removed, as required to accommodate the jamb clips.
Tilt-wash double-hung and double-hung transom (DHT) windows are secured
in opening by removing the sash and jamb liners and drilling through the side
jamb into the masonry. For double-hung picture (DHP) windows, remove the
side jamb liner cover only.
APPLICATION:
•
First secure jamb clip to back side of window unit jamb(s)
•
Apply 1' from corners of head jamb, sill and side jambs
•
Space jamb clips evenly (maximum distance apart 32" on center)
•
Jamb clip lateral design load capacity: maximum 200 lb.
Jamb clip
Threaded fastener
(furnished by others)
Score markings for bending
1-1/2"
(38)
3/16"
(5)
Make sure that the unit frame parts do not become bowed when using
anchoring methods. Unit will not operate properly if frame parts are stressed.
3"
(76)
3-12
A R C H I T E C T U R A L
D E T A I L
F I L E
R E V. 0 3 / 0 5
T ilt-Wash Double-Hung W indows
Suggested Product Applications
Wall Types
Scale 1-1/2" = 1'-0" (1:8)
Remove
installation
flange
at head
Installation
flange
all around
Rough Opening Height
1/4"
(6)
Rgh. Opg.
Width
Rough Opening Height
Rgh. Opg.
Width
1/4"
(6)
Unit Dim.
Width
Unit Dimension Height
Head
Unit Dim.
Width
Unit Dimension Height
Head
Jamb
Jamb
1/2" (13)*
minimum
Installation
flange all
around
Sill
*1/2" (13) minimum to accommodate differential
shrinkage/expansion when brick is used with wood framing.
Sill
Vertical Section
Vertical Section
Wood Siding / 2 x 4 Wood Stud Framing
Brick Veneer / 2 x 6 Metal Stud Framing
Importance of Proper Installation
Rough Opening Height
Rgh. Opg.
Width
1/4"
(6)
Unit Dim.
Width
Unit Dimension Height
Head
Proper installation and maintenance of Andersen® products are essential if optimum
performance is to be fully attained. Written installation instructions which provide guidelines
for proper installation are available for Andersen products from your local Andersen supplier or
by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at
www.andersenwindows.com. Remember that every installation is different. Andersen strongly
recommends consultation with an Andersen product representative and with an experienced
contractor, architect, or structural engineer prior to the installation of any Andersen product.
Installation of Andersen products, including method of attachment, fastener selection, and
code compliance is the sole responsibility of the architect, building owner, contractor, and/or
consumer.
Construction by Others
Jamb
Andersen Corporation is not responsible for the design of, conditions in, or performance of,
adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration
of the Andersen units with the weather-repellent system of the building is the responsibility of
others.
Membrane
flashing over
installation
flange
(by others)
Installation
flange all
around
NOTE: Where E.I.F.S. wall finish is adjacent to window units, contact E.I.F.S. manufacturer for installation
instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the
proper width of sealant joint around the perimeter of the window.
Sill
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework.
Installation flange may be removed where construction sequence/ detailing requires no flange.
Vertical Section
E.I.F.S. / Concrete Masonr y Unit (CMU)
R E V. 0 3 / 0 5
A R C H I T E C T U R A L
D E T A I L
F I L E
3-13
T ilt-Wash Double-Hung W indows
Suggested Product Applications
Wall Types
Rgh. Opg.
Width
1/4"
(6)
Unit Dim.
Width
Rgh. Opg.
Width
Jamb
Unit Dimension Height
1/4"
(6)
Unit Dim.
Width
Unit Dimension Height
Rough Opening Height
Rgh. Opg.
Width
1/4"
(6)
Unit Dim.
Width
Unit Dimension Height
Head
Head
Head
Rough Opening Height
Installation
flange
at head
and jambs
Rough Opening Height
Optional
Andersen®
auxiliary
casing
Existing
frame wall
Optional
Andersen®
vinyl trim
board
Optional
Andersen®
auxiliary
casing
Jamb
Jamb
Installation
flange
all around
Remove
installation
flange
at sill
Installation
flange
all around
Sill
Rgh. Opg.
Width
Jamb
Optional
Andersen
extension
jambs
Installation
flange all
around
Rough Opening Height
Head
Unit Dim.
Width
Unit Dimension Height
Stucco / Concrete Masonr y Unit
(CMU) Inset Window
Existing
masonry wall
1/4"
(6)
Vertical Section
Vertical Section
Vertical Section
Brick / Concrete Masonr y Unit (CMU)
Optional
Andersen®
vinyl trim
board.
Trim to fit
as required.
Finish trimmed
edge with
Optional
Andersen
rigid vinyl
channel
Sill
Sill
Existing Stud Wall
Importance of Proper Installation
Proper installation and maintenance of Andersen® products are essential if optimum
performance is to be fully attained. Written installation instructions which provide guidelines
for proper installation are available for Andersen products from your local Andersen supplier or
by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at
www.andersenwindows.com. Remember that every installation is different. Andersen strongly
recommends consultation with an Andersen product representative and with an experienced
contractor, architect, or structural engineer prior to the installation of any Andersen product.
Installation of Andersen products, including method of attachment, fastener selection, and
code compliance is the sole responsibility of the architect, building owner, contractor, and/or
consumer.
Construction by Others
Andersen Corporation is not responsible for the design of, conditions in, or performance of,
adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration
of the Andersen units with the weather-repellent system of the building is the responsibility of
others.
NOTE: Where E.I.F.S. wall finish is adjacent to window units, contact E.I.F.S. manufacturer for installation
instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the
proper width of sealant joint around the perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework.
Installation flange may be removed where construction sequence/ detailing requires no flange.
Sill
Vertical Section
Existing Masonr y Wall
3-14
A R C H I T E C T U R A L
D E T A I L
F I L E
R E V. 0 3 / 0 5