T ilt-Wash Double-Hung W indows Contents Tilt-Wash Double-Hung Windows Basic Unit Details - Tilt-Wash Double-Hung ....................................3-2 Basic Unit Details - Double-Hung Picture and Transom Window .......3-3 Options / Accessories Andersen® Grilles .......................................................................3-4 Stools and Extension Jambs for Tilt-Wash Basic Units .................3-6 Stools and Extension Jambs for Double-Hung Picture Units ........3-7 Stools and Extension Jambs for Double-Hung Transom Units ......3-8 Combination Unit .......................................................................3-8 Joining Details ................................................................................3-9 • Slim frame and sash profile maximize the field of view • Excellent for creating window combinations • Easy to clean. • Low maintenance. R E V. 0 3 / 0 5 Anchoring Methods .......................................................................3-12 Suggested Product Applications ....................................................3-13 A R C H I T E C T U R A L D E T A I L F I L E 3-1 T ilt-Wash Double-Hung W indows Basic Unit Details - Tilt-Wash Double-Hung Basic Unit 1-5/16" (33) Scale 3" = 1'-0" (1:4) 4-1/2" (114) Lower sash in open position 3/8" (10) 2-7/16" (62) Optional Andersen® insect screen High-Performance™ insulating glass Unit Dimension Height 1-5/16" (33) Clear Opening Height Rough Opening Height Head 1-1/2" (38) Check Rail Optional Andersen® stool 1-1/2" (38) 5/8" (16) 3-9/16" (91) 2-7/16" (62) 1/2" (13) 3/8" (10) Fibrex™ material sill Sill Vertical Section 3-5/16" (84) 3-5/16" (84) Jamb Jamb Lower sash 4-1/2" (114) Upper sash 1-5/16" (33) 1-7/8" (37) 1/4" (6) Clear Opening Width Unit Dimension Width 1-7/8" (37) Optional Andersen® insect screen 1/4" (6) Rough Opening Width Horizontal Section 3-2 A R C H I T E C T U R A L D E T A I L F I L E R E V. 0 3 / 0 5 T ilt-Wash Double-Hung W indows Basic Unit Details - Double-Hung Picture (DHP) and Transom (DHT) Window Picture Unit Transom Unit Scale 3" = 1'-0" (1:4) Scale 3" = 1'-0" (1:4) 1-5/16" (33) 4-1/2" (114) 1-5/16" (33) 4-1/2" (114) Clad aluminum 1/4" (6) 3/8" (10) 2-3/8" (60) 1-1/2" (38) Glass Height Optional Andersen® stool Unit Dimension Height Rough Opening Height Glass Height Unit Dimension Height Rough Opening Height 2-7/16" (62) 5/8" (16) 2-7/16" (62) 2-15/16" (75) 1/2" (13) 3/8" (10) 1/4" (6) Fibrex™ material sill Clad aluminum Vertical Section Vertical Section 4-1/2" (114) 4-1/2" (114) 1-5/16" (33) 1-5/16" (33) 2-7/16" (62) 1/4" (6) 3-5/16" (84) 2-7/16" (62) Glass Width Unit Dimension Width 1/4" (6) 1/4" (6) 1/4" (6) Horizontal Section Horizontal Section A R C H I T E C T U R A L 3-5/16" (84) Rough Opening Width Rough Opening Width R E V. 0 3 / 0 5 Glass Width Unit Dimension Width D E T A I L F I L E 3-3 T ilt-Wash Double-Hung W indows Options / Accessories Exterior Color Frenchwood® Patio Door Sidelights & Transoms Frenchwood® Hinged Outswing Frenchwood® Hinged Inswing Andersen® 400 Series Doors Frenchwood® Gliding Gothic Circle & Oval Elliptical Flexiframe® Springline™ Arch Circle Top™ & Quarter Round Tilt-Wash Picture Window Tilt-Wash Double-Hung & Transom Woodwright® Springline™ Single-Hung Woodwright® Picture Window Gliding Window Casement & Awning Please check with Andersen for availability Casement Picture Window Available only with 3/8" glass through the Andersen Divided Light program Woodwright® Double-Hung & Transom Available now Woodwright® Archtop & Unequal Leg Archtop Andersen® 400 Series Windows 200 Series Narroline® Double-Hung & Transom Andersen ® Divided Light Grilles White Sandtone Terratone® Forest Green Width 3/4" 7/8" 1-1/8" Type 2-1/4" With Spacer Without Spacer Interior Maple Oak Prefinished Pine Colonial Modified Colonial Modified Col W/Check Rail Prairie A Patterns Short Fractional Short Fractional W/Check Rail Tall Fractional Tall Fractional W/Check Rail Victorian Renaissance Sunburst Specified Equal Light Custom Glass HP/HP Tempered HP Sun/HP Sun Temp 3/8" Low-E/Temp Single-Pane Impact 3-4 A R C H I T E C T U R A L D E T A I L F I L E R E V. 0 3 / 0 5 T ilt-Wash Double-Hung W indows Options / Accessories 400 Series Grille Options Removable Interior Andersen® Divided Light Grille Permanent Exterior Removable Interior Andersen® Divided Light Grille Permanent Exterior Permanent Interior Andersen® Divided Light Grille Permanent Exterior Permanent Interior with Spacer Andersen® Finelight™ Grilles-Between-the-Glass Grille Profiles • Scale = Full • Dimensions include thickness of tape. Permanent Exterior Fibrex® Material Grille Profiles (chamfer profile). Also used for pre-finished interior, except 400 Series Woodwright® double-hung windows. 5/16" 7/16" 1/2" 1-13/16" 45˚ 45˚ 45˚ 35˚ 5/16" 5/16" 5/16" 7/8" 3/4" 5/16" 1-1/8" 2-1/4" Permanent Interior Wood Grille Profiles (chamfer profile). The Fibrex® material exterior grille is used when a permanent prefinished grille is specified, except with 400 Series Woodwright® double-hung windows. 5/16" 3/8" 3/8" 53˚ 1-13/16" 1/2" 7/16" 3/8" 53˚ 7/16" 35˚ 53˚ 3/32" 7/8" 3/4" 1-1/8" Removable Interior Wood Grille Profile (roman ogee profile). 2-1/4" Removable Interior Wood Grille Profile (Chamfer profile). 400 Series Woodwright® double-hung windows only. 1/2" 7/16" 3/4" 3/4" 1-1/8" 7/8" 7/8" 1-1/8" Permanent Full Divided Light Grille spacer location. 1/2" 1/2" 1/8" 1/2" 1/2" 5/16" 3/16" 1/2" 1/8" Andersen® Finelight™ Grilles-Between-the-Glass. R E V. 0 3 / 0 5 3/8" 1/2" 3/4" 1" A R C H I T E C T U R A L D E T A I L F I L E 3-5 T ilt-Wash Double-Hung W indows Options / Accessories Stools and Extension Jambs for Tilt-Wash Basic Units Scale 3" = 1'-0" (1:4) 7-1/8" (181) 6-9/16" (167) 5-1/4" (133) 4-9/16" (116) Extension Jambs 5-1/4" (133) Wall 11/16" (17) 3/8" (10) 23/32" (18) 6-9/16" (167) Wall 2-1/32" (52) Head 7-1/8" (181) Wall 2-19/32" (66) Jamb Optional factory applied DP upgrade sill stop Stools Optional Andersen® stool For wall thicknesses up to 5-1/4" (133) 23/32" (18) 2-15/16" (75) For wall thicknesses up to 7-1/8" (181) 1-27/32" (47) 3-27/32" (98) Sill 4-9/16" (116) Extension jambs available for 5-1/4" (133), 6-9/16" (167) or 7-1/8" (181) wall thickness. Stools are available for wall thicknesses up to 5-1/4" (133) or 7-1/8" (181) thick. Other wall dimensions can be accommodated with stool and extension jamb modification. Extension jambs are predrilled for easy application (except for 5-1/4" (133) sizes). 5-1/4" (133) 6-9/16" (167) 7-1/8" (181) Vertical Section 3-6 A R C H I T E C T U R A L D E T A I L F I L E R E V. 0 3 / 0 5 T ilt-Wash Double-Hung W indows Options / Accessories Stools and Extension Jambs for Double-Hung Picture Units (DHP) Scale 3" = 1'-0" (1:4) 7-1/8" (181) 6-9/16" (167) 5-1/4" (133) 4-9/16" (116) Extension Jambs 5-1/4" (133) Wall 11/16" (17) 3/8" (10) 23/32" (18) 6-9/16" (167) Wall 2-1/32" (52) Head 7-1/8" (181) Wall 2-19/32" (66) Jamb Stools Optional Andersen® stool For wall thicknesses up to 5-1/4" (133) 23/32" (18) 2-15/16" (75) 1-27/32" (47) For wall thicknesses up to 7-1/8" (181) 3-27/32" (98) Sill 4-9/16" (116) 5-1/4" (133) 6-9/16" (167) 7-1/8" (181) Extension jambs available for 5-1/4" (133), 6-9/16" (167) or 7-1/8" (181) wall thickness. Stools are available for wall thicknesses up to 5-1/4" (133) or 7-1/8" (181) thick. Other wall dimensions can be accommodated with stool and extension jamb modification. Extension jambs are predrilled for easy application (except for 5-1/4" (133) sizes). Vertical Section R E V. 0 3 / 0 5 A R C H I T E C T U R A L D E T A I L F I L E 3-7 T ilt-Wash Double-Hung W indows Options / Accessories Combination Unit Scale 3" = 1'-0" (1:4) Stools and Extension Jambs for Double-Hung Transom Units (DHT) Scale 3" = 1'-0" (1:4) 1-5/16" (33) 4-1/2" (114) 7-1/8" (181) 6-9/16" (167) 5-1/4" (133) 4-9/16" (116) Hinge member Combination unit for triple glazing Extension Jambs Head 5-1/4" (133) Wall 3/8" (10) 11/16" (17) Stationary upper storm panel 23/32" (18) 6-9/16" (167) Wall 2-1/32" (52) Head Check Rail Insect screen Optional Andersen® stool 7-1/8" (181) Wall 2-19/32" (66) Operating lower panel Extension jambs available for 5-1/4" (133), 6-9/16" (167) or 7-1/8" (181) wall thickness. Stools are available for wall thicknesses up to 5-1/4" (133) or 7-1/8" (181) thick. Other wall dimensions can be accommodated with stool and extension jamb modification. Extension jambs are predrilled for easy application (except for 5-1/4" (133) sizes). Jamb Sill Vertical Section Stools Optional Andersen® stool For wall thicknesses up to 5-1/4" (133) Combination unit 23/32" (18) 1-27/32" (47) For wall thicknesses up to 7-1/8" (181) Jamb Horizontal Section 3-27/32" (98) At Head- Outer frame of combination unit fits into head jamb window unit. Hinges fastened to the exterior of the head jamb enables easy cleaning of the sill. At Check Rail - Strong aluminum check rail with stationary storm panel, insect screen and lower operating panel. At Jamb - Storm panel operates on smooth vinyl channels within the side stile frame members. Insect screen is located outside the storm panel. At Sill - Combination unit frame bottom rail with insect screen in place and operating lower panel in closed position. Complete unit furnished by Andersen, not applied to window unit. Sill 4-9/16" (116) 5-1/4" (133) 6-9/16" (167) 7-1/8" (181) Vertical Section 3-8 A R C H I T E C T U R A L D E T A I L F I L E R E V. 0 3 / 0 5 T ilt-Wash Double-Hung W indows Joining Details Tilt-Wash Double-Hung to Tilt-Wash Double-Hung Double-Hung Picture to Double-Hung Picture Scale 3" = 1'-0" (1:4) Scale 3" = 1'-0" (1:4) Optional Andersen® interior trim Unit Dimension Width Unit Dimension Width 1/8" (3) (Ref.) Optional Andersen® exterior vinyl trim strip set in continuous bead of sealant each side Optional Andersen® interior trim Optional Andersen® exterior vinyl trim strip set in continuous bead of sealant each side Unit Dimension Width Unit Dimension Width 1/8" (3) (Ref.) Non-Reinforced Mullion Non-Reinforced Mullion 2-7/8" (73) 2-7/8" (73) Optional Andersen® interior trim Optional Andersen® interior trim Optional Andersen® steel reinforced join Optional Andersen® steel reinforced join Unit Dimension Width Unit Dimension Width 3/16" (5) Optional Andersen® exterior vinyl trim strip set in continuous bead of sealant each side Steel Reinforced Mullion Unit Dimension Width 2" (51) Unit Dimension Width Unit Dimension Width Unit Dimension Width Optional Andersen® exterior vinyl trim strip set in continuous bead of sealant each side 3/16" (5) Steel Reinforced Mullion Interior trim by others Interior trim by others Structural support by others Structural support by others Optional Andersen® 2" support mullion wood filler Optional Andersen® 2" support mullion wood filler Optional Andersen® 2" support trim strip set in continuous bead of sealant each side Optional Andersen® 2" support mullion trimstrip set in continuous bead of sealant each side Unit Dimension Width Support Mullion 2" (51) Unit Dimension Width Support Mullion Joining Compatibility Many Andersen® units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Andersen® Product Guide for Professionals, in Andersen Window Studio® software, and by visiting www.andersenwindows.com. Combination designs should always be checked for design pressure performance requirements to ensure the appropriate joining method is specified. R E V. 0 3 / 0 6 A R C H I T E C T U R A L D E T A I L F I L E 3-9 T ilt-Wash Double-Hung W indows Joining Details Double-Hung Transom to Double-Hung Transom Scale 3" = 1'-0" (1:4) Interior trim by others Unit Dimension Width Unit Dimension Width Joining Compatibilty Optional Andersen® exterior vinyl trim strip set in continuous bead of sealant each side Many Andersen® units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Andersen® Product Guide for Professionals, in Andersen Window Studio® software, and by visiting www.andersenwindows.com. Combination designs should always be checked for design pressure performance requirements to ensure the appropriate joining method is specified. 1/8" (3) (Ref.) Non-Reinforced Mullion 2-7/8" (73) Optional Andersen® interior trim Optional Andersen® steel reinforced join Unit Dimension Width Unit Dimension Width 3/16" (5) Optional Andersen® exterior vinyl trim strip set in continuous bead of sealant each side Steel Reinforced Mullion Interior trin by others Structural support by others Optional Andersen® 2" support mullion wood filler Unit Dim. 2" (51) Unit Dim. Optional Andersen® 2" support mullion trim strip set in continuous bead of sealant each side Support Mullion 3-10 A R C H I T E C T U R A L D E T A I L F I L E R E V. 0 3 / 0 5 T ilt-Wash Double-Hung W indows Joining Details Double-Hung Transom (DHT) over Tilt-Wash Double-Hung Scale 3" = 1'-0" (1:4) 1-5/16" (33) 4-1/2" (114) 3/8" (10) Unit Dimension Height 2-3/8" (60) Transom Optional Andersen® trim 2-15/16" (75) 0" 1/16" (2) 2-7/16" (62) Unit Dimension Height Tilt-Wash Unit Dimension + Double-Hung Transom Unit Dimension = Overall Unit Dimension Rough Opening Height 1/8" (3) Head 3-9/16" (91) 5/8" (16) 2-7/16" (62) 1/2" (13) 3/8" (10) Sill Vertical Section R E V. 0 3 / 0 5 A R C H I T E C T U R A L D E T A I L F I L E 3-11 T ilt-Wash Double-Hung W indows Anchoring Methods Installation Flange Standard Installation Flange Reversed Scale 3" = 1'-0" (1:4) Scale 3" = 1'-0" (1:4) Standard application of installation flanges as shipped from Andersen to be used for 4-1/2" (105) wall construction. Tilt-wash double-hung window is secured in the opening by using threaded fasteners through the installation flange. Regular installation flange in reverse position to accommodate a 4-1/8" (105) wall. 1/2" (13) 4 1/2" (114) 4-1/8" (105) 3 1/2" (89) 1/2" (13) Jamb Clip Threaded Masonr y Fastener / Expansion Sleeve Scale 3" = 1'-0" (1:4) Scale 3" = 1'-0" (1:4) Double-hung window unit secured in opening by others using Andersen® 302 stainless steel sheet metal jamb clips and stainless steel screws. Bend the jamb clips to secure unit fit in opening. Installation flange can be cut, or removed, as required to accommodate the jamb clips. Tilt-wash double-hung and double-hung transom (DHT) windows are secured in opening by removing the sash and jamb liners and drilling through the side jamb into the masonry. For double-hung picture (DHP) windows, remove the side jamb liner cover only. APPLICATION: • First secure jamb clip to back side of window unit jamb(s) • Apply 1' from corners of head jamb, sill and side jambs • Space jamb clips evenly (maximum distance apart 32" on center) • Jamb clip lateral design load capacity: maximum 200 lb. Jamb clip Threaded fastener (furnished by others) Score markings for bending 1-1/2" (38) 3/16" (5) Make sure that the unit frame parts do not become bowed when using anchoring methods. Unit will not operate properly if frame parts are stressed. 3" (76) 3-12 A R C H I T E C T U R A L D E T A I L F I L E R E V. 0 3 / 0 5 T ilt-Wash Double-Hung W indows Suggested Product Applications Wall Types Scale 1-1/2" = 1'-0" (1:8) Remove installation flange at head Installation flange all around Rough Opening Height 1/4" (6) Rgh. Opg. Width Rough Opening Height Rgh. Opg. Width 1/4" (6) Unit Dim. Width Unit Dimension Height Head Unit Dim. Width Unit Dimension Height Head Jamb Jamb 1/2" (13)* minimum Installation flange all around Sill *1/2" (13) minimum to accommodate differential shrinkage/expansion when brick is used with wood framing. Sill Vertical Section Vertical Section Wood Siding / 2 x 4 Wood Stud Framing Brick Veneer / 2 x 6 Metal Stud Framing Importance of Proper Installation Rough Opening Height Rgh. Opg. Width 1/4" (6) Unit Dim. Width Unit Dimension Height Head Proper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer. Construction by Others Jamb Andersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others. Membrane flashing over installation flange (by others) Installation flange all around NOTE: Where E.I.F.S. wall finish is adjacent to window units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper width of sealant joint around the perimeter of the window. Sill NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/ detailing requires no flange. Vertical Section E.I.F.S. / Concrete Masonr y Unit (CMU) R E V. 0 3 / 0 5 A R C H I T E C T U R A L D E T A I L F I L E 3-13 T ilt-Wash Double-Hung W indows Suggested Product Applications Wall Types Rgh. Opg. Width 1/4" (6) Unit Dim. Width Rgh. Opg. Width Jamb Unit Dimension Height 1/4" (6) Unit Dim. Width Unit Dimension Height Rough Opening Height Rgh. Opg. Width 1/4" (6) Unit Dim. Width Unit Dimension Height Head Head Head Rough Opening Height Installation flange at head and jambs Rough Opening Height Optional Andersen® auxiliary casing Existing frame wall Optional Andersen® vinyl trim board Optional Andersen® auxiliary casing Jamb Jamb Installation flange all around Remove installation flange at sill Installation flange all around Sill Rgh. Opg. Width Jamb Optional Andersen extension jambs Installation flange all around Rough Opening Height Head Unit Dim. Width Unit Dimension Height Stucco / Concrete Masonr y Unit (CMU) Inset Window Existing masonry wall 1/4" (6) Vertical Section Vertical Section Vertical Section Brick / Concrete Masonr y Unit (CMU) Optional Andersen® vinyl trim board. Trim to fit as required. Finish trimmed edge with Optional Andersen rigid vinyl channel Sill Sill Existing Stud Wall Importance of Proper Installation Proper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer. Construction by Others Andersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others. NOTE: Where E.I.F.S. wall finish is adjacent to window units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper width of sealant joint around the perimeter of the window. NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/ detailing requires no flange. Sill Vertical Section Existing Masonr y Wall 3-14 A R C H I T E C T U R A L D E T A I L F I L E R E V. 0 3 / 0 5
© Copyright 2026 Paperzz