Zareba Metro Controller The Metro controller is capable of monitoring up to 250 Metro remote addressable gas detectors. Metro Controller Cost Effective • • • • • Low cost controller and detector Installation costs minimized No booster supplies required Uses industry standard cable Return on investment through reduced site running costs verified through system data log Flexible by Design • • • • Up to 2 x 125 detectors over 2 x 1Km (3000 feet) 8 user configurable relays Grouping, voting, instantaneous or time delayed operation Automatic and manual operation with override facility The Metro controller is capable of monitoring up to 250 Metro remote addressable gas detectors. Together they form the Metro system designed to protect people from flammable and toxic gas hazards commonly found in car parks, tunnels or other areas where automotive vehicles may operate. One Stop Shop • • • • Controller complete with mounting bracket Detector including base and vandal proof guard CO, LPG, LNG, CH4 and NO2 available Range of accessories including UPS,evacuation signs, audible and visual alarms Proven Gas Detector Technology • • • • SurecellTM electrochemical toxic sensors Poison resistant catalytic bead flammable sensors Fast and reliable Complies with relevant standards Convenient to Use • • • • • Auto-backlit display for dark environments Unhindered access to large terminal compartment M20 and 3⁄4" pre-formed knockouts in base Auto-recognition of field devices Infrared remote control supplied for set up and configuration of field devices and inputs Life Costs Minimized • • • • Plug in, serviceable gas detectors Modular construction minimizes downtime Simple design reduces spare part inventory Full support via Honeywell Analytics Service Centres throughout the world The Metro controller provides automatic control of ventilation systems that maintain gas levels at or below a safe level. Where gas levels rise above maximum exposure limits the Metro system raises alarms to instigate site evacuation. By integrating the gas monitoring system and ventilation control not only are harmful gases kept to safe levels but building running costs are also minimized. The system allows for two separate radial circuits up to 1km (3000 feet) long using industry standard cable. Each circuit provides power and communications for up to 125 detectors. Each system is able to monitor 250 toxic, 125 flammable or a mix of 80 toxic and 80 flammable detectors. The AC system design ensures no booster power supplies are required to achieve long cable runs, greatly simplifying the system specification, installation and operation. Equipment installation and commissioning is kept as simple as possible. A wall-mounting bracket is provided to which the slim line controller is fitted. All cables and conduits enter the lower side of the controller via the pre-formed knockouts. Clearly marked terminals ensure cabling connections are rapidly completed. Once the controller and detectors are installed and powered up, the controller automatically recognizes which detectors are fitted. Adjustment of detector settings can be made via an infrared remote control unit as required. With up to 250 addressable gas detectors fitted to a system, each with 4 alarm levels, up to 1000 alarm events can be detected by the controller, all of which are logged for later review. Grouping, voting and activation of up to eight fully programmable relays can be set up via the push-button interface or optional PC software. Each relay can be configured for normally energized/de-energized, latching/non-latching and on/off delay operation. Manual override switches for all relays are included as standard in the controller. In addition system operation may be forced remotely via a Remote Override Box if required. Easy to specify, install and operate, used as a standalone gas monitoring system or as part of a wider building management system, the Metro gas detection system ensures people are kept safe from gas hazards and building operating costs are minimized. Installation Details Highlights The Metro controller should be mounted with the display at eye level using the mounting bracket provided. All cable entries are made from the bottom via pre-formed M16/M20 and 3⁄4" NPT knockouts as appropriate to the method of cable installation. The system electrical supply should be made via a lockable fused isolator suitable for the overall power requirements. 5 core, AC rated, 1mm2 (17AWG) minimum, with overall screen should be used for installation. Cable may be channelled though conduit depending on site practice. Continuity of the screen should be maintained throughout the system for maximum resistance to RFI. Dimensions Wiring Arrangement Screening Power wires must loop through Ferrite, as shown. Controller Detector 1 (L)ive (N)eutral S+ SFE To next detector Shield terminated through gland Star point Screen To avoid ‘ground loops’ screens should only be bonded to Earth at the controller. For improved EMC/RFI performance ensure continuity of screen throughout all detectors. Via Functional Earth (FE) Installation Details System Overview The maximum installed cable length is 1Km (3000 feet) per circuit of up to 125 gas detectors. Two inputs are available providing a maximum system capacity of up to 250 detectors over 2Km (6000 feet). A range of associated equipment is available for use with the Metro system providing users with a ‘one stop shop’ for all their requirements. For further information also see the Metro Detector datasheet or request our installation guide from your Honeywell Analytics representative. Terminal Detail AC INPUT 230Vac +/- 10% 50Hz (1.1kVA maximum) FE Functional Earth FE Functional Earth Installation Details/ Technical Summary Other Equipment Available Text Signs Wall or ceiling mounted warning signs. Text only viewable once light is activated. Available in multiple languages. Audible & Visual Alarms Range of ultra-bright Xenon flashing lights and high intensity audible alarms. Available singly or as combined audiovisual alarm units. UPS (Battery Backup) Online and line interactive range of uninterruptible power supplies (UPS) depending on site requirements. Varying back up capacity subject to project needs. Application Example Underground Car Park Typical Equipment Requirements Item Quantity Power Total Power Metro Controller x1 15VA each 15VA Capable of monitoring up to 250 detectors over 2Km (6000 feet) Metro CO Detector x 11 4.8VA each 52.8VA 1 per 400m2 typically required mounted at 1.5m (5 feet) above ground level Metro LPG Detector x 11 8VA each 88VA Mounted at approximately 0.2m (0.7 feet) from ground level below CO detector Not required in all countries Vandal Proof Guard x 22 N/a N/a Flush or surface mounting option available Text Signs x5 160VA each 800VA Should be positioned so as to be visible every 30m (100 feet) Audible/Visual Alarm x5 15VA each 75VA Installed along side Text Signs typically Total Power Required (Normal Operation) 155.8VA Total Power Required (Full Alarm) 1030.8VA 1500VA Battery Backup / UPS provides nominal run time of: > 60 minutes (normal operation) > 9 minutes (full alarm) A range of supplies are available that can be tailored to specific project needs as required Extended run times available upon request Other equipment will be required to complete installation. Contact your Honeywell Analytics representative General Specification Use Metro addressable gas detector control system for monitoring of flammable and toxic gas hazards commonly found where motor vehicles operate such as car parks, tunnels or warehouses. Provides central monitoring of detector status, local annunciation and automatic control of ventilation and evacuation systems. Suitable for use as an indoor standalone solution or as part of a larger distributed control system Operation Display Ultra-clear display with automatic backlight operation for dark environments. Details relay and detector status, first alarm indication with scrolling history of events, as well as providing alternate pages for review of relay output and fault histories Other Indication Ultra bright alarm and power LEDs Audible Alarm 85dBA at 1m / 90dBA at 1 foot, user hush facility with re-activation on subsequent events. Can be permanently disabled for ‘silent’ operation User Interface Three level access for normal user, supervisor and service engineer. Normal user: Accept/reset of alarms or review of current events only Supervisor (via key locked door): As above plus configuration/system interrogation using concealed pushbuttons Service: As above with access to all terminal compartments via removable isolation plates System Override Automatic/manual operation of all relays via manual override switches (service function) or via Remote Override Box ZHC2 Infrared Remote Control Supplied with each system the ZHC2 allows convenient set up and configuration of all field devices. Field configured detector information is then downloaded into controller to configure all inputs General Specification cont... Electrical Supply 230Vac +/- 10% 50Hz Maximum power (controller only) 15VA Add power consumption for ‘other’ field devices as required Detector Inputs Each circuit provides power and communications for up to 125 detectors. Each system is able to monitor 250 toxic, 125 flammable or a mix of 80 toxic and 80 flammable detectors. Each detector provides 4 levels of alarm (instantaneous or time weighted) and fault indication Pulse width modulated digital link for robust communications between detector and controller Communications RS485 bus providing detector address, gas type and general status via: 9 pin ‘D’ connector (for local commissioning and setup) Wired terminals (for permanent connection to control rooms etc) Relays 8 x SPCO 5A, 240Vac relays (non inductive load). Fully programmable as normally energized/de-energized, on/off delay, grouping and voting logic Environmental IP Rating Indoor use, IP44 in accordance with EN60529:1992 Weight 3.8Kg (8.4lb) 0 Operating Temperature -10°C to +40°C (14°F to 104°F) Operating Humidity 10-90%RH (non condensing) Operating Pressure 90-110Kpa Storage Conditions -40°C to +80°C (-40°F to +176°F), 20 to 80%RH (non condensing) Ordering Information Standard Supply Each control panel is supplied complete with mounting bracket, ZHC2 Infrared Remote Control and Operating Instructions Part Number Description MCXX Metro control panel for up to 250 gas detectors. 230Vac +/- 10% 50Hz Shipping Details Shipping carton dimensions: 445mm x 405mm x 180mm (17.5" x 15.9" x 7.1") Gross weight: 5.1Kg (11.2lb) Other Equipment Find out more www.honeywellanalytics.com Customer business centre Europe and the rest of the world Honeywell Analytics AG Wilstrasse 11-U11 CH-8610 Uster Switzerland Tel: +41 (0)44 943 4300 Fax: +41 (0)44 943 4398 [email protected] MDF1S Metro flammable gas detector (0-100% LEL Propane) c/w surface mount guard MDF1F Metro flammable gas detector (0-100% LEL Propane) c/w flush mount guard MDC1S Metro CO gas detector (0-300ppm) c/w surface mount guard MDC1F Metro CO gas detector (0-300ppm) c/w flush mount guard MDN1S Metro NO2 gas detector (0-10ppm) c/w surface mount guard MDN1F Metro NO2 gas detector (0-10ppm) c/w flush mount guard MKXX Remote override box Calibration Equipment MDCC Calibration cup for detector ZCALREG1 Pre-set 0.3l/m (300cc/min) flow regulator SPPPTUB 1m Tygon tubing (suitable for all gases) 2302D0765 Carry case for up to 2x2AL gas cylinders, regulators, tubing For calibration gas contact your local Honeywell Analytics representative www.honeywell.com Please Note: While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract. © 2005 Honeywell Analytics H_Metro Controller_DS0330_V1 12/05 © 2005 Honeywell Analytics 11134 Customer business center Americas Honeywell Analytics Distribution, Inc. 400 Sawgrass Corporate Pkwy Suite 100 Sunrise, FL 33325 USA Tel: +1 954 514 2700 Toll free: +1 800 538 0363 Fax: +1 954 514 2784 [email protected]
© Copyright 2026 Paperzz