EW100 Series Singlejet Water Meters

EW100 Series
Singlejet Water Meters
DN15…20 FOR COLD AND WARM POTABLE WATER APPLICATIONS
PRODUCT DATA
CONTENTS
EW1000 for cold water
EW1001 for warm water
Contents ............................................................................... 1
General ................................................................................. 2
Application .......................................................................... 2
Features ............................................................................. 2
Design ................................................................................ 2
Materials ............................................................................. 2
Approvals ........................................................................... 2
Technical Details ................................................................. 3
Specifications ..................................................................... 3
Flow Data ........................................................................... 3
Sizing ................................................................................. 3
Function ............................................................................. 3
Counter ........................................................................... 3
Flow Sensor .................................................................... 3
Interfaces ........................................................................ 3
Installation .......................................................................... 3
Communication and Readout ............................................. 3
Communication Options ................................................. 3
Setup .............................................................................. 4
Readout Options ............................................................. 4
Identification ....................................................................... 4
Meter Identification in the Field ....................................... 4
Front Panel Contents ...................................................... 4
Dimensions ........................................................................ 5
Ordering Details ................................................................... 6
Ordering Information .......................................................... 6
Scope of Delivery ............................................................... 6
Accessories ........................................................................ 6
Connection Sets ............................................................. 6
Other Accessories .......................................................... 6
Clip on RF module
Honeywell y All rights reserved
EN0H-0427GE25 R0313
EW100 SERIES SINGLEJET WATER METERS
GENERAL
Application
Honeywell EW100 Series singlejet water meters are used for
flow measurement of cold or warm water in residential potable
water systems.
They are available in sizes DN15 to DN20 and have a mechanical counter. They can be retrofitted with clip on RF modules for
integration into fixed or mobile RF networks. The RF protocol
used is compatible with Honeywell’s range of RF heat cost allocators.
EW1000 water meters are suitable for cold water up to 30°C.
EW1001 water meters are suitable for warm water up to 90°C.
5
1
6
2
7
3
8
4
Features
• MID approval
Fig. 1. EW100 main components
• Compact design
• Rotatable counter
Table 2. EW100 Series main components
• Retrofittable RF modules
Number
Component
1
EW100 Series water meters consist of:
• Rotatable mechanical counter
Transparent cover with approval marks and
serial number
2
Counter housing
• Cover for clip on modules
3
Flow sensor housing
• Singlejet mechanical flow measuring unit
4
Inlet with sieve
• Housing with external threads according to ISO228 on inlet
and outlet and a sieve on the inlet
5
Eight digit roller counter
6
Cover for clip on modules
Materials
7
Outlet
8
Flow arrow
Design
• Counter housing and flow measuring unit made of plastic
• Housing of singlejet flow sensor made of brass
Approvals
Table 1. Approvals EW100 Series
DN size
Approval
Metrological class
15-20
MID
B
EN0H-0427GE25 R0313
2
Honeywell y All rights reserved
EW100 SERIES SINGLEJET WATER METERS
TECHNICAL DETAILS
Specifications
Function
Counter
Sizes
DN15…DN20
qp 2.5…4
Medium
Potable water
Medium temperature
EW1000: 1…30°C
EW1001: 1…90°C
Ambient temperature
1…55°C
Storage temperature
1…60°C
Operating pressure
max. 16bar
The singlejet technology of the flow sensor combines high
measuring accuracy with long term stability. The impeller is
connected to the counter by a magnetic coupling.
Protection class
IP54
Interfaces
Measuring process
Mechanical compact water meter
with impeller and singlejet volume
measurement
EW100 Series water meters can be retrofitted with a clip on RF
module. For more details on interfaces see chapter “Communication and Readout” below.
Display
Roller counter, 8-digit
Unit
m³
Installation
Environmental class
(OIML R49)
B
(fixed meter, indoors)
• Calming legs before or after EW100 Series water meters are
not required
Interfaces
RF (optional, retrofittable)
• All sizes may be installed in any position. In vertical position
the dynamic range is smaller
The meter can be read from a single line eight-digit roller
counter with m³ as unit. The counter unit can be rotated for
better readibility. The roller counter has five places and three
decimal places.
Flow Sensor
• Avoid installation at highest point of system or system part as
air may be trapped in meter
Flow Data
DN size
15
20
• It is recommended to place a ballvalve before and after the
meter for easy replacement
31
50
• During measurement meter must be completely filled with
water
Flow rates according to MID
Minimum (Q1)
l/h (horizontal)
l/h (vertical)
63
100
Pemanent (Q3)
m³/h
2.5
4
Communication and Readout
Overload (Q4)
m³/h
3.125
5
Communication Options
Dynamic range
(Q3/Q1)
horizontal
80:1
80:1
vertical
40:1
40:1
Nominal flow Qn
m³/h
1.5
2.5
Starting flowrate
l/h
<8
<15
Pressure loss @ Q3
mbar
630
630
Flowrate @ p=1bar
m³/h
3.2
5.1
EW100 Series water meters can be retrofitted with a clip on RF
module. The RF modules allow the meter to be integrated into
RF networks designed for remote readout of HCAs (heat cost
allocators).
Two modules are available
• EW9106AFZ001 for integration of an EW100 into a fixed RF
network (‘AMR’)
Additional flow data
• EW9106AFZ002 for integration of an EW100 into a mobile
RF network system (‘walk by’)
EW9106AFZ002 can be upgraded for use in a fixed RF
network. EW9106AFZ001 cannot be downgraded for use in a
walk by RF system.
Also see separate data sheet ‘EW9106 RF Modules’.
Sizing
• EW100 Series water meters should be selected in such a
way that permanent system flow rates are between minimum
flow rate (Q1) and permanent flow rate (Q3)
Setup
EW100 Series water meters require no setup.
• The flow rate may not drop below minimum flow rate (Q1)
and may not exceed overload flow rate (Q4)
Readout Options
• Manual readout by visiting meter and reading consumption
values off roller counter
• RF: remote readout by attaching meter to a mobile or fixed
RF network. For this meter must be equipped with clip on RF
module EW9106AFZ001 or EW9106AFZ002
Honeywell y All rights reserved
3
EN0H-0427GE25 R0313
EW100 SERIES SINGLEJET WATER METERS
Identification
Meter Identification in the Field
• Transparent round rotatable counter housing permanently
fixed to flow sensor housing
• White cover for clip on mount, with blue or red bar (indicating
cold or warm water), Honeywell logo and designation
‘EW100 Series’
• Unpainted brass housing with external threads on inlet and
outlet
Front Panel Contents
1
9
2
8
1
8
2
7
7
3
6
3
6
4
4
5
5
Fig. 2. Top view of EW100 with front panel elements
Fig. 3. Top view of EW9106 with front panel elements
Table 3. Front panel elements
Number
Element
Number
1
Serial number
1
Transparent housing
2
Approval mark
2
OS Number (order number)
3
Permanent flow Q3 and dynamic range
3
IrDA port for use with opto head
4
MID approval number
4
'Honeywell' logomark
5
‘EW100 Series’ mark
5
CE mark and wheelie bin symbol
6
‘Honeywell’ logomark
6
Serial number as barcode and clear text
7
Pressure and temperature rating
7
IrDA interface indicator
8
Roller counter and unit
8
RF antenna
9
CE mark
EN0H-0427GE25 R0313
4
Element
Honeywell y All rights reserved
EW100 SERIES SINGLEJET WATER METERS
Dimensions
Fig. 4. Dimensions EW100 Series
NOTE:
• All dimensions in mm unless stated otherwise
• Weight is without fittings or any other accessories
Table 4. Dimensions EW100 Series
DN Size
Length
L
Meter
thread
Height
H
Counter diameter
Weight
15
80
G 3/4“ B
69
65
0.40 kg
15
110
G 3/4“ B
69
65
0.43 kg
20
130
G 1“ B
69
65
0.63 kg
Honeywell y All rights reserved
5
EN0H-0427GE25 R0313
EW100 SERIES SINGLEJET WATER METERS
ORDERING DETAILS
Ordering Information
Table 5. OS-Nos. (OS=Order Specification)
Item
DN size
EW100 Series
singlejet
water meters
Flowrate Q3
Length
OS-Number
for cold water
for warm water
15
2.5 m³/h
80 mm
EW1000AZ1101
EW1001AZ1101
15
2.5 m³/h
110 mm
EW1000AZ1201
EW1001AZ1201
20
4 m³/h
130 mm
EW1000AZ2001
EW1001AZ2001
Scope of Delivery
• EW100 Series water meter
• Two paper sealings
• Locking wire and seal
• Installation and setup instructions
Accessories
Connection Sets
Other Accessories
Set of union nut, sealing and externally threaded brass
tailpiece (one pack per meter required)
Ballvalve with internal threads
For DN15, 1/2” x 3/4”
EWA1500035
For DN20, 3/4” x 1”
EWA1500042
Set of union nut, sealing and Sanpress red bronze crimp
fitting (two packs per meter required)
For DN15, for 15mm pipe-Ø
VA7404A015
For DN15, for 18mm pipe-Ø
VA7404A018
For DN20, for 22mm pipe-Ø
VA7404A020
DN15, G1/2” internal thread
EWA087HY004
DN20, G 3/4” internal thread
EWA087HY005
Clip on RF modules
Fixed network (AMR)
module
EW9106AFZ001
Mobile network (walk by)
module
EW9106AFZ002
Set of union nut, sealing and Mapress stainless steel
crimp fitting (two packs per meter required)
For DN15, for 15mm pipe-Ø
VA7403A015
For DN15, for 18mm pipe-Ø
VA7403A018
For DN20, for 22mm pipe-Ø
VA7403A020
Set of union nut, sealing and internally threaded red
bronze tailpiece (two packs per meter required)
NOTE:
For DN15, thread Rp1/2”
VA7405A015
For DN20, thread Rp3/4”
VA7405A020
Union nuts of connection sets VA7403, VA7404 and
VA7405 are not sealable with locking wire. Union nuts
of connection set EWA150… are drilled for sealing
with locking wire
Environmental and Combustion Controls
Honeywell GmbH
Hardhofweg
74821 MOSBACH
GERMANY
Phone: +49 (6261) 810
Fax: +49 (6261) 81393
http://ecc.emea.honeywell.com
EN0H-0427GE25 R0313
March 2013 (Rev. C)
© 2013 Honeywell International Inc.
Subject to change without notice
Manufactured for and on behalf of the Environmental and
Combustion Controls Division of Honeywell Technologies
Sàrl, Z.A. La Pièce 16, 1180 Rolle, Switzerland or its Authorized Representative.