EW100 Series Singlejet Water Meters DN15…20 FOR COLD AND WARM POTABLE WATER APPLICATIONS PRODUCT DATA CONTENTS EW1000 for cold water EW1001 for warm water Contents ............................................................................... 1 General ................................................................................. 2 Application .......................................................................... 2 Features ............................................................................. 2 Design ................................................................................ 2 Materials ............................................................................. 2 Approvals ........................................................................... 2 Technical Details ................................................................. 3 Specifications ..................................................................... 3 Flow Data ........................................................................... 3 Sizing ................................................................................. 3 Function ............................................................................. 3 Counter ........................................................................... 3 Flow Sensor .................................................................... 3 Interfaces ........................................................................ 3 Installation .......................................................................... 3 Communication and Readout ............................................. 3 Communication Options ................................................. 3 Setup .............................................................................. 4 Readout Options ............................................................. 4 Identification ....................................................................... 4 Meter Identification in the Field ....................................... 4 Front Panel Contents ...................................................... 4 Dimensions ........................................................................ 5 Ordering Details ................................................................... 6 Ordering Information .......................................................... 6 Scope of Delivery ............................................................... 6 Accessories ........................................................................ 6 Connection Sets ............................................................. 6 Other Accessories .......................................................... 6 Clip on RF module Honeywell y All rights reserved EN0H-0427GE25 R0313 EW100 SERIES SINGLEJET WATER METERS GENERAL Application Honeywell EW100 Series singlejet water meters are used for flow measurement of cold or warm water in residential potable water systems. They are available in sizes DN15 to DN20 and have a mechanical counter. They can be retrofitted with clip on RF modules for integration into fixed or mobile RF networks. The RF protocol used is compatible with Honeywell’s range of RF heat cost allocators. EW1000 water meters are suitable for cold water up to 30°C. EW1001 water meters are suitable for warm water up to 90°C. 5 1 6 2 7 3 8 4 Features • MID approval Fig. 1. EW100 main components • Compact design • Rotatable counter Table 2. EW100 Series main components • Retrofittable RF modules Number Component 1 EW100 Series water meters consist of: • Rotatable mechanical counter Transparent cover with approval marks and serial number 2 Counter housing • Cover for clip on modules 3 Flow sensor housing • Singlejet mechanical flow measuring unit 4 Inlet with sieve • Housing with external threads according to ISO228 on inlet and outlet and a sieve on the inlet 5 Eight digit roller counter 6 Cover for clip on modules Materials 7 Outlet 8 Flow arrow Design • Counter housing and flow measuring unit made of plastic • Housing of singlejet flow sensor made of brass Approvals Table 1. Approvals EW100 Series DN size Approval Metrological class 15-20 MID B EN0H-0427GE25 R0313 2 Honeywell y All rights reserved EW100 SERIES SINGLEJET WATER METERS TECHNICAL DETAILS Specifications Function Counter Sizes DN15…DN20 qp 2.5…4 Medium Potable water Medium temperature EW1000: 1…30°C EW1001: 1…90°C Ambient temperature 1…55°C Storage temperature 1…60°C Operating pressure max. 16bar The singlejet technology of the flow sensor combines high measuring accuracy with long term stability. The impeller is connected to the counter by a magnetic coupling. Protection class IP54 Interfaces Measuring process Mechanical compact water meter with impeller and singlejet volume measurement EW100 Series water meters can be retrofitted with a clip on RF module. For more details on interfaces see chapter “Communication and Readout” below. Display Roller counter, 8-digit Unit m³ Installation Environmental class (OIML R49) B (fixed meter, indoors) • Calming legs before or after EW100 Series water meters are not required Interfaces RF (optional, retrofittable) • All sizes may be installed in any position. In vertical position the dynamic range is smaller The meter can be read from a single line eight-digit roller counter with m³ as unit. The counter unit can be rotated for better readibility. The roller counter has five places and three decimal places. Flow Sensor • Avoid installation at highest point of system or system part as air may be trapped in meter Flow Data DN size 15 20 • It is recommended to place a ballvalve before and after the meter for easy replacement 31 50 • During measurement meter must be completely filled with water Flow rates according to MID Minimum (Q1) l/h (horizontal) l/h (vertical) 63 100 Pemanent (Q3) m³/h 2.5 4 Communication and Readout Overload (Q4) m³/h 3.125 5 Communication Options Dynamic range (Q3/Q1) horizontal 80:1 80:1 vertical 40:1 40:1 Nominal flow Qn m³/h 1.5 2.5 Starting flowrate l/h <8 <15 Pressure loss @ Q3 mbar 630 630 Flowrate @ p=1bar m³/h 3.2 5.1 EW100 Series water meters can be retrofitted with a clip on RF module. The RF modules allow the meter to be integrated into RF networks designed for remote readout of HCAs (heat cost allocators). Two modules are available • EW9106AFZ001 for integration of an EW100 into a fixed RF network (‘AMR’) Additional flow data • EW9106AFZ002 for integration of an EW100 into a mobile RF network system (‘walk by’) EW9106AFZ002 can be upgraded for use in a fixed RF network. EW9106AFZ001 cannot be downgraded for use in a walk by RF system. Also see separate data sheet ‘EW9106 RF Modules’. Sizing • EW100 Series water meters should be selected in such a way that permanent system flow rates are between minimum flow rate (Q1) and permanent flow rate (Q3) Setup EW100 Series water meters require no setup. • The flow rate may not drop below minimum flow rate (Q1) and may not exceed overload flow rate (Q4) Readout Options • Manual readout by visiting meter and reading consumption values off roller counter • RF: remote readout by attaching meter to a mobile or fixed RF network. For this meter must be equipped with clip on RF module EW9106AFZ001 or EW9106AFZ002 Honeywell y All rights reserved 3 EN0H-0427GE25 R0313 EW100 SERIES SINGLEJET WATER METERS Identification Meter Identification in the Field • Transparent round rotatable counter housing permanently fixed to flow sensor housing • White cover for clip on mount, with blue or red bar (indicating cold or warm water), Honeywell logo and designation ‘EW100 Series’ • Unpainted brass housing with external threads on inlet and outlet Front Panel Contents 1 9 2 8 1 8 2 7 7 3 6 3 6 4 4 5 5 Fig. 2. Top view of EW100 with front panel elements Fig. 3. Top view of EW9106 with front panel elements Table 3. Front panel elements Number Element Number 1 Serial number 1 Transparent housing 2 Approval mark 2 OS Number (order number) 3 Permanent flow Q3 and dynamic range 3 IrDA port for use with opto head 4 MID approval number 4 'Honeywell' logomark 5 ‘EW100 Series’ mark 5 CE mark and wheelie bin symbol 6 ‘Honeywell’ logomark 6 Serial number as barcode and clear text 7 Pressure and temperature rating 7 IrDA interface indicator 8 Roller counter and unit 8 RF antenna 9 CE mark EN0H-0427GE25 R0313 4 Element Honeywell y All rights reserved EW100 SERIES SINGLEJET WATER METERS Dimensions Fig. 4. Dimensions EW100 Series NOTE: • All dimensions in mm unless stated otherwise • Weight is without fittings or any other accessories Table 4. Dimensions EW100 Series DN Size Length L Meter thread Height H Counter diameter Weight 15 80 G 3/4“ B 69 65 0.40 kg 15 110 G 3/4“ B 69 65 0.43 kg 20 130 G 1“ B 69 65 0.63 kg Honeywell y All rights reserved 5 EN0H-0427GE25 R0313 EW100 SERIES SINGLEJET WATER METERS ORDERING DETAILS Ordering Information Table 5. OS-Nos. (OS=Order Specification) Item DN size EW100 Series singlejet water meters Flowrate Q3 Length OS-Number for cold water for warm water 15 2.5 m³/h 80 mm EW1000AZ1101 EW1001AZ1101 15 2.5 m³/h 110 mm EW1000AZ1201 EW1001AZ1201 20 4 m³/h 130 mm EW1000AZ2001 EW1001AZ2001 Scope of Delivery • EW100 Series water meter • Two paper sealings • Locking wire and seal • Installation and setup instructions Accessories Connection Sets Other Accessories Set of union nut, sealing and externally threaded brass tailpiece (one pack per meter required) Ballvalve with internal threads For DN15, 1/2” x 3/4” EWA1500035 For DN20, 3/4” x 1” EWA1500042 Set of union nut, sealing and Sanpress red bronze crimp fitting (two packs per meter required) For DN15, for 15mm pipe-Ø VA7404A015 For DN15, for 18mm pipe-Ø VA7404A018 For DN20, for 22mm pipe-Ø VA7404A020 DN15, G1/2” internal thread EWA087HY004 DN20, G 3/4” internal thread EWA087HY005 Clip on RF modules Fixed network (AMR) module EW9106AFZ001 Mobile network (walk by) module EW9106AFZ002 Set of union nut, sealing and Mapress stainless steel crimp fitting (two packs per meter required) For DN15, for 15mm pipe-Ø VA7403A015 For DN15, for 18mm pipe-Ø VA7403A018 For DN20, for 22mm pipe-Ø VA7403A020 Set of union nut, sealing and internally threaded red bronze tailpiece (two packs per meter required) NOTE: For DN15, thread Rp1/2” VA7405A015 For DN20, thread Rp3/4” VA7405A020 Union nuts of connection sets VA7403, VA7404 and VA7405 are not sealable with locking wire. Union nuts of connection set EWA150… are drilled for sealing with locking wire Environmental and Combustion Controls Honeywell GmbH Hardhofweg 74821 MOSBACH GERMANY Phone: +49 (6261) 810 Fax: +49 (6261) 81393 http://ecc.emea.honeywell.com EN0H-0427GE25 R0313 March 2013 (Rev. C) © 2013 Honeywell International Inc. Subject to change without notice Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Z.A. La Pièce 16, 1180 Rolle, Switzerland or its Authorized Representative.
© Copyright 2025 Paperzz