Most Widely Accepted and Trusted 0 ICC-ES Listing Report ICC-ES | (800) 423-6587 | (562) 699-0543 | www.icc-es.org 000 ESL-1080 Issued 09/2016 This listing is subject to renewal 09/2017. DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION SECTION: 07 21 00—THERMAL INSULATION SECTION: 07 25 00—WATER-RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: ICYNENE INC. 6747 CAMPOBELLO ROAD MISSISSAUGA, ONTARIO L5N 2L7 CANADA EVALUATION SUBJECT: ICYNENE PROSEAL ECO (MD-R-210) CLOSED-CELL SPRAY POLYURETHANE FOAM INSULATION Look for the trusted marks of Conformity! “2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence” ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright © 2016 ICC Evaluation Service, LLC. All rights reserved. A Subsidiary of ICC-ES Listing Report ESL-1080 Issued September 2016 This listing is subject to renewal September 2017. www.icc-es.org | (800) 423-6587 | (562) 699-0543 CSI: A Subsidiary of the International Code Council ® DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 21 00—Thermal Insulation Section: 07 25 00—Water-resistive Barriers/Weather Barriers Product Certification System: The ICC-ES product-certification system includes evaluating reports of tests of standard manufactured product, prepared by accredited testing laboratories and provided by the listee, to verify compliance with applicable codes and standards. The system also involves factory inspections, and assessment and surveillance of the listee’s quality system. Product: ICYNENE PROSEAL ECO (MD-R-210) CLOSED-CELL SPRAY POLYURETHANE FOAM INSULATION Listee: ICYNENE INC. 6747 CAMPOBELLO ROAD MISSISSAUGA, ONTARIO L5N 2L7 CANADA (905) 363-4040 www.icynene.com Evaluation: The Icynene ProSeal Eco (MD-R-210) Closed-Cell Spray Polyurethane Foam Insulation was evaluated based on a tested exterior non-load-bearing wall assembly consisting of building-material components described in the Assembly Section, tested in accordance with the following standards: UL 263-11, UL 263-03 (with revisions through October 2007) and UL 263-03, Standard for Fire Tests of Building Construction and Materials, Underwriters Laboratories, Inc. ASTM E119-2012A, ASTM E119-08a, ASTM E119-07 and ASTM E119-00, Standard Test Methods for Fire Tests of Building Construction and Materials, ASTM International. Assembly: Exterior Face: Nominally 6-inch-deep, No. 18 gage galvanized steel studs, spaced 16 inches (406 mm) on 1 center, are fastened to No. 18 gage galvanized steel floor and ceiling tracks. One layer of /2-inch-thick ® (12.7 mm) Georgia Pacific DensGlass Gold Exterior Sheathing is installed with the long edge parallel to steel studs with vertical joints offset a minimum of 16 inches (406 mm) from the vertical joints of the interior Type X gypsum board, and the horizontal joints offset a minimum of 24 inches (610 mm) from the horizontal 1 joints of the gypsum board. The sheathing is attached using 1 /4-inch- long (32 mm) self-drilling drywall screws spaced 8 inches (203 mm) on center around the perimeter and in the field. Hohmann & Barnard 1 DW-10 brick ties, 6 inches (152 mm) long by 1 /2 inches (38 mm) wide, are spaced 16 inches (406 mm) on 5 center vertically on each steel stud, and secured using two 1 /8-inch-long (41 mm) self-drilling screws, 1 1 3 through 4-inch (102 mm) red clay brick [(3 /2 inches (89 mm) by 2 /4 inches (57 mm) by 7 /4 inches (197 mm)], laid in a running bond pattern with Type S mortar, leaving a nominally 1-inch air gap between the brick and the exterior sheathing. The stud cavity is filled with Icynene ProSeal Eco (MD-R-210) insulation to a maximum nominal thickness of 6 inches. 5 Interior Face: Two layers of Type X gypsum board, /8 inch (15.9 mm) thick and complying with ASTM C1396, are applied to the interior side with joints offset from each other a minimum of 16 inches (406 mm) 1 and with the long edge parallel to steel studs. The gypsum board is secured using 1 /4-inch-long (32 mm), self-drilling drywall screws spaced 8 inches (203 mm) on center around the perimeter and 12 inches (305 mm) on center in the field. The gypsum board joints must be treated with vinyl or casein, dry or premixed joint compound applied in two coats to cover all exposed screw heads and gypsum board butt joints. A minimum 2-inch-wide (51 mm) paper, plastic, or fiberglass tape is embedded in the first layer of compound over butt joints of the gypsum board. Listings are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the listing or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this listing, or as to any product covered by the listing. 1000 Copyright © 2016 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 2 ESL-1080 | Most Widely Accepted and Trusted Findings: Page 2 of 2 The assembly described in the Assembly Section, with the Icynene ProSeal Eco (MD-R-210) Closed-Cell Spray Polyurethane Foam Insulation as a component of the assembly, is a three-hour fire-resistance-rated exterior non-load-bearing wall assembly, based on testing in accordance with UL 263/ASTM E119, as referenced in the applicable sections of the following code editions: 2015, 2012, and 2009 International Building Code Applicable Section: 703.2 and 705 ® ® 2006 International Building Code Applicable Section: 703.2 and 704 2015, 2012, 2009, and 2006 International Residential Code Applicable Section: R302 ® Identification: Containers of Icynene ProSeal Eco (MD-R-210) components are identified with a label bearing the Icynene Inc. name and address; the product trade name [Icynene ProSeal Eco (MD-R-210)]; the lot number; the flame spread and smoke developed indices; mixing instructions; density; the shelf life and the expiration date; the evaluation report number (ESR-3493), the listing report number (ESL-1080), and when applicable, the listing mark. Installation: The Icynene ProSeal Eco (MD-R-210) Closed-Cell Spray Polyurethane Foam Insulation shall be installed in accordance with the Icynene Inc. published installation instructions and applicable codes. Conditions of Listing: 1. The listing report addresses only conformance with the standards and code sections noted above. 2. Approval of the product’s use is the sole responsibility of the local code official. 3. The listing report applies only to the materials tested and as submitted for review by ICC-ES. 4. The Assembly Section describes the assembly using Icynene ProSeal Eco (MD-R-210) Closed-Cell Spray Polyurethane Foam Insulation that is qualified for use in an exterior non-load-bearing wall fireresistance-rated assembly.
© Copyright 2026 Paperzz