ANACONDA SEALTITE® conduit systems Trade size Sealtite inch 1/4" 5/16" 3/8" 1/2" 3/4" 1" 1.1/4" 1.1/2" Fittings ISO M12 M16/M20 M16 M20 M25 M32 M40 M50 PG 7 9 11/13,5 16 21 29 36 42 NPT - - 1/2" 1/2" 3/4" 1" 1.1/4" 1.1/2" Inside diameter mm 6,4 10,1 12,6 16,0 21,0 26,5 35,1 40,3 Outside diameter mm 11,5 14,4 17,8 21,1 26,4 33,1 41,8 47,8 Type E.F. Type EF Bending radius static mm 40 50 60 75 90 120 135 165 (centerline) dynamic mm 50 65 85 110 140 170 215 250 Standard carton Type EF 50 50 75 60 50 30 30 15 Article no. grey m 311.006.1 311.010.1 311.012.1 311.016.1 311.020.1 311.026.1 311.035.1 311.040.1 Article no. black 315.006.1 315.010.1 315.012.1 315.016.1 315.020.1 315.026.1 315.035.1 315.040.1 - Small carton - 10 10 10 10 - - Article no. grey m - 311.010.3 311.012.3 311.016.3 311.020.3 - - - Article no. black - 315.010.3 315.012.3 315.016.3 315.020.3 - - - Reel m Article no. grey - - 250 150 120 90 60 45 - - 311.012.5 311.016.5 311.020.5 311.026.5 311.035.5 311.040.5 315.012.5 315.016.5 315.020.5 315.026.5 315.035.5 315.040.5 Article no. black E.F. in 5" and 6" available on request. Type E.F.L.; E.F. in aluminiun available on request. Type O.R. Type OR Inside diameter mm 6,4 10,1 12,6 16,0 21,0 26,5 35,1 40,3 Outside diameter mm 11,5 14,4 17,8 21,1 26,4 33,1 41,8 47,8 Bending radius static mm 40 50 60 75 90 120 135 165 (centerline) dynamic mm 50 65 85 110 140 170 215 250 Standard carton m Article no. black Reel 250 250 75 60 50 30 30 15 320.006.1 320.010.1 320.012.1 320.016.1 320.020.1 320.026.1 320.035.1 320.040.1 m Article no. black - - 250 150 120 90 60 45 - - 320.012.5 320.016.5 320.020.5 320.026.5 320.035.5 320.040.5 EN 50086 CLASSIFICATION* 1 Compression Impact Min. Max. Bending Electrical Resistance to ingress resistance resistance temp. temp. resistance properties of solid objects 4 Heavy 4 (1250 N) E.F. Heavy 4 -25°C 1+ +70°C 4 (6 J) I Flexible 3*2 With electrical 6 Dust-tight Resistance to ingress P of water 7 Protected against the continuity and effects of temporary insulating immersion in water; characteristics 4 O.R. Heavy (1250 N) 4 Heavy 3 -15°C (6 J) 2 +100°C 4 Flexible 3*2 With electrical 6 1 m deep, 30 min. Dust-tight 7 Protected against the continuity and effects of temporary insulating immersion in water; characteristics 1 m deep, 30 min. * 1 Classification according to EN 50086 is done in combination with the fittings (see catalogue) and also counts as a minimum for the complete range of sizes. Though, for some size in the range a higher classification is possible--> consult your Anamet representative for more information. * 2 Fitting non-insulating. 33 * 3 Based on stainless steel fittings (with standard fittings, class 2 counts for the whole system). * 4 Dynamic application only at temperatures above 0°C. ANACONDA SEALTITE ® 2" 2.1/2" 3" 4" M63 - - - 48 - - - 2" 2.1/2" 3" 4" 51,6 63,3 78,4 102,1 Anaconda Sealtite ® represents the top of our range. The construction of this conduit consists of a robust galvanised square-locked core with cord-packing and a thermoplastic cover. This proven construction method ensures secure attachment of core and cover for long life and performance. Over 50 years of field experience attests to the quality and durability of Sealtite ® conduits. E.F.: universal Type E.F. is the most universal applicable Anaconda Sealtite ® conduit. The E.F. is meant for applications 59,9 72,6 88,4 where no extreme external parameters have influence on the conduit and therefore E.F. can be used in many 113,8 areas. The E.F. is, among others, being used in glass-producing-companies, paper-recycling industry, internal 210 280 425 490 transport-systems and the train-building industry. With VDE approval for the sizes 3/8 till 1 1/4 and DEMKO, 300 360 520 600 NEMKO, SEMKO and SETI approval for the sizes 3/8 till 2. Construction : galvanised steel core, square-locked with cord packing, thermoplastic (PVC Temperature : -25ºC to +70ºC, intermittent up to +90ºC. Colour : black & grey. oil & grease 15 7,5 7,5 7,5 311.050.1 311.063.1 311.075.1 311.100.1 315.050.1 315.063.1 315.075.1 315.100.1 compound) cover. - - - - - - - - - - - - 22 - - - 311.050.5 - - - 51,6 63,3 78,4 102,1 O.R.: 59,9 72,6 88,4 113,8 As a result of the high resistance against these substances the flexibility of the conduit is being safeguarded. 210 280 425 490 300 360 520 600 industry. With DEMKO, NEMKO, SEMKO and SETI approval for the sizes 3/8 till 2. Construction : galvanised steel core, square-locked with cord packing, thermoplastic Temperature : -15ºC to +100ºC, intermittent up to +120ºC. Colour : black. 315.050.5 15 7,5 7,5 7,5 320.050.1 320.063.1 320.075.1 320.100.1 22 - - - 320.050.5 - - - Anaconda Sealtite ® O.R. is preferred in areas where conduit systems are being exposed to oils and greases. With other (non resistant) covers these substances can lead to stiffening or even rupture of the cover. Type O.R. is being applied in the machine-building industry, diesel-engines, paper, chemical and petrochemical (PVC compound) cover. Corrosion Tensile Resistance to Suspended resistance strength flame propagation load capacity inside/outside 3* 3 Medium/ 4 high 3* 3 Medium/ high Heavy 1 (1000 N) 4 Heavy (1000 N) Non-flame 0 propagating 1 Non-flame propagating None declared 0 None declared ANACONDA SEALTITE® conduit systems Trade size Sealtite inch 1/4" 5/16" 3/8" 1/2" 3/4" 1" 1.1/4" 1.1/2" Fittings ISO M12 M16/M20 M16 M20 M25 M32 M40 M50 PG 7 9 11/13,5 16 21 29 36 42 NPT - - 1/2" 1/2" 3/4" 1" 1.1/4" 1.1/2" Inside diameter mm 6,4 10,1 12,6 16,0 21,0 26,5 35,1 40,3 Outside diameter mm 11,5 14,4 17,8 21,1 26,4 33,1 41,8 47,8 Type H.C. Type H.C. Bending radius static mm 40 50 60 75 90 120 135 165 (centerline) dynamic mm 50 65 85 110 140 170 215 250 *4 Standard carton m Article no. 250 250 75 60 50 30 30 15 317.006.1 317.010.1 317.012.1 317.016.1 317.020.1 317.026.1 317.035.1 317.040.1 Reel m - - 250 150 120 90 60 45 Article no. black - - 317.012.5 317.016.5 317.020.5 317.026.5 317.035.5 317.040.5 317.050.5 Inside diameter mm - - 12,6 16,0 21,0 26,5 35,1 40,3 Outside diameter mm - - 17,8 21,1 26,4 33,1 41,8 47,8 Type H.C.X. Type H.C.X. Bending radius static mm (centerline) dynamic mm - - m - - 30 30 30 30 15 15 - - 326.012.1 326.016.1 326.020.1 326.026.1 326.035.1 326.040.1 Standard carton Article no. black 60 75 90 120 135 165 85 110 140 170 215 250 EN 50086 CLASSIFICATION* 1 Compression Impact Min. Max. Bending Electrical Resistance to ingress resistance resistance temp. temp. resistance properties of solid objects 4 4 (1250 N) H.C. 4 H.C.X. Heavy Heavy (1250 N) Heavy 5 -45°C 3 +105°C 4 (6 J) 4 Heavy 5+ -55°C 4+ +145°C 4 (6 J) I Flexible 3*2 With electrical 6 Dust-tight Resistance to ingress P of water 7 Protected against the continuity and effects of temporary insulating immersion in water; characteristics Flexible 3*2 With electrical 6 Dust-tight 1 m deep, 30 min. 7 Protected against the continuity and effects of temporary insulating immersion in water; characteristics 1 m deep, 30 min. * 1 Classification according to EN 50086 is done in combination with the fittings (see catalogue) and also counts as a minimum for the complete range of sizes. Though, for some size in the range a higher classification is possible--> consult your Anamet representative for more information. * 2 Fitting non-insulating. 35 * 3 Based on stainless steel fittings (with standard fittings, class 2 counts for the whole system). * 4 Dynamic applications only at temperatures above 0°C. 2" 2.1/2" 3" 4" M63 - - - 48 - - - 2" 2.1/2" 3" 4" 51,6 63,6 78,4 102,1 H.C.: 59,9 72,6 88,4 113,8 strength at both high as low temperatures. Type H.C. can be used in areas where strong temperature changes 210 280 425 490 300 *4 360 *4 520 *4 600 *4 15 7,5 7,5 7,5 317.050.1 317.063.1 317.075.1 317.100.1 22 - - - - - - - 51,6 - - wide temperature range In case we have to cope with high temperatures, than the H.C. is the better choice. The cover keeps its occur. The H.C. can be found in transformers, the train-building industry, foundry, ceramic and materials and concrete industry. With NEMKO, DEMKO, SEMKO, en SETI approval for the sizes 3/8 till 2. Construction : galvanised steel core, square-locked with cord packing, thermoplastic (PVC Temperature : -45ºC tot +105ºC, intermittent up to +120ºC. Colour : black. H.C.X.: extreme temperatures compound) cover. - Extreme cold, heat or temperature changes are conditions in which the H.C.X. performs the best. The cover of 59,9 - - - 210 - - - 300 - - - 15 - - - 326.050.1 - - - this conduit has both a very high as low temperature resistance, which also ensures that changes in the temperature are not being transferred to the electrical wiring. The H.C.X. keeps its flexibility at low temperatures. Type H.C.X. is often used in the train-building and foundry industry and in cybernetics. Corrosion Tensile Resistance to Suspended resistance strength flame propagation load capacity Medium/ 4 high 3*3 Medium/ high Heavy 1 (1000 N) 4 Heavy (1000 N) Non-flame 0 propagating 2 : galvanised steel core, square-locked with cord packing, thermoplastic Temperature : -55ºC tot +145ºC, intermittent up to +160ºC. Colour : black. (elastomer) cover. inside/outside 3*3 Construction Flame propagating None declared 0 None declared ANACONDA SEALTITE® conduit systems Trade size Sealtite inch 1/4" 5/16" 3/8" 1/2" 3/4" 1" 1.1/4" 1.1/2" Fittings ISO M12 M16/M20 M16 M20 M25 M32 M40 M50 PG 7 9 11/13,5 16 21 29 36 42 NPT - - 1/2" 1/2" 3/4" 1" 1.1/4" 1.1/2" Inside diameter mm - 10,1 12,6 16,0 21,0 26,5 35,1 - Outside diameter mm - 14,4 17,8 21,1 26,4 33,1 41,8 - Type Z.H.L.S. Type Z.H.L.S. Bending radius static mm - 50 60 75 90 120 135 - (centerline) dynamic mm - 65 85 110 140 170 215 - Standard carton m Article no. grey - 30 30 30 30 30 15 - - 308.010.1 308.012.1 308.016.1 308.020.1 308.026.1 308.035.1 - Type H.F.X. Type H.F.X. Inside diameter mm - 10,1 12,6 16,0 21,0 26,5 35,1 - Outside diameter mm - 14,4 17,8 21,1 26,4 33,1 41,8 - Bending radius static mm - 50 60 75 90 120 135 - (centerline) dynamic mm - 65 85 110 140 170 215 - m - 50 30 30 30 30 15 - - 331.010.1 331.012.1 331.026.1 331.035.1 - Standard carton Article no. black 331.016.1 331.020.1 EN 50086 CLASSIFICATION* 1 Compression Impact Min. Max. Bending Electrical Resistance to ingress resistance resistance temp. temp. resistance properties of solid objects 4 Heavy 4 (1250 N) Z.H.L.S. Heavy 5+ -50°C 4+ +125°C 4 (6 J) I Flexible 3*2 With electrical 6 Dust-tight H.F.X. Heavy (1250 N) 4 Heavy (6 J) 4+ -40°C 3 +105°C 4 ingress P of water 7 Protected against the continuity and effects of temporary insulating immersion in water; characteristics 4 Resistance to Flexible 3*2 With electrical 6 1 m deep, 30 min. Dust-tight 7 Protected against the continuity and effects of temporary insulating immersion in water; characteristics 1 m deep, 30 min. * 1 Classification according to EN 50086 is done in combination with the fittings (see catalogue) and also counts as a minimum for the complete range of sizes. Though, for some size in the range a higher classification is possible--> consult your Anamet representative for more information. 37 * 2 Fitting non-insulating. * 3 Based on stainless steel fittings (with standard fittings, class 2 counts for the whole system). 2" 2.1/2" 3" 4" M63 - - - 48 - - - 2" 2.1/2" 3" 4" - - - - Z.H.L.S.: halogen free & low smoke* A halogen free, low smoke conduit for use in public areas. The features of the Z.H.L.S. cover are necessary - - - in the field of environment and safety, as the European guidelines state that certain areas need to be free of - halogens. The Z.H.L.S. is optimal for use in the subway, train and bus-building industry, in closed areas, - - - - - - - - - - - - - - - - airports, tunnels and (subway) stations Construction : galvanised steel core, square-locked with cord packing, thermoplastic (rubber) Temperature : -50ºC tot +125ºC, intermittent up to +140ºC. Colour : grey. cover. * Test results with regard to smoke development and harmful gases in case of fire, on request. - - - H.F.X.: - halogen free & very flexible A halogen free conduit for use in public areas. The features of the H.F.X. cover are necessary in the field of environment and safety, as the European guidelines state that certain areas need to be free of halogens. - - - - - - - - makes the H.F.X. very suitable for installations, which are subject to frequent movements. The H.F.X. is often - - - - being applied in the subway, train and bus-building industry, in closed areas, airports, tunnels and Another unique feature of the H.F.X. is, that it is extremely flexible at both high as low temperatures. This (subway)stations - - - - - - - - Construction : galvanised steel core, square-locked with cord packing, thermoplastic Temperature : -40ºC tot +105ºC, intermittent up to +125ºC. Colour : black. (polyurethane) cover. Corrosion Tensile Resistance to Suspended resistance strength flame propagation load capacity inside/outside 3*3 Medium/ 4 high 3*3 Medium/ high Heavy 1 (1000 N) 4 Heavy (1000 N) Non-flame 0 propagating 1 Non-flame propagating None declared 0 None declared
© Copyright 2026 Paperzz