ANACONDASEALTITE ® conduitsystems

ANACONDA SEALTITE® conduit systems
Trade size Sealtite
inch
1/4"
5/16"
3/8"
1/2"
3/4"
1"
1.1/4"
1.1/2"
Fittings
ISO
M12
M16/M20
M16
M20
M25
M32
M40
M50
PG
7
9
11/13,5
16
21
29
36
42
NPT
-
-
1/2"
1/2"
3/4"
1"
1.1/4"
1.1/2"
Inside diameter
mm
6,4
10,1
12,6
16,0
21,0
26,5
35,1
40,3
Outside diameter
mm
11,5
14,4
17,8
21,1
26,4
33,1
41,8
47,8
Type E.F.
Type EF
Bending radius
static
mm
40
50
60
75
90
120
135
165
(centerline)
dynamic
mm
50
65
85
110
140
170
215
250
Standard carton
Type EF
50
50
75
60
50
30
30
15
Article no. grey
m
311.006.1
311.010.1
311.012.1
311.016.1
311.020.1
311.026.1
311.035.1
311.040.1
Article no. black
315.006.1
315.010.1
315.012.1
315.016.1
315.020.1
315.026.1
315.035.1
315.040.1
-
Small carton
-
10
10
10
10
-
-
Article no. grey
m
-
311.010.3
311.012.3
311.016.3
311.020.3
-
-
-
Article no. black
-
315.010.3
315.012.3
315.016.3
315.020.3
-
-
-
Reel
m
Article no. grey
-
-
250
150
120
90
60
45
-
-
311.012.5
311.016.5
311.020.5
311.026.5
311.035.5
311.040.5
315.012.5
315.016.5
315.020.5
315.026.5
315.035.5
315.040.5
Article no. black
E.F. in 5" and 6" available on request. Type E.F.L.; E.F. in aluminiun available on request.
Type O.R.
Type OR
Inside diameter
mm
6,4
10,1
12,6
16,0
21,0
26,5
35,1
40,3
Outside diameter
mm
11,5
14,4
17,8
21,1
26,4
33,1
41,8
47,8
Bending radius
static
mm
40
50
60
75
90
120
135
165
(centerline)
dynamic
mm
50
65
85
110
140
170
215
250
Standard carton
m
Article no. black
Reel
250
250
75
60
50
30
30
15
320.006.1
320.010.1
320.012.1
320.016.1
320.020.1
320.026.1
320.035.1
320.040.1
m
Article no. black
-
-
250
150
120
90
60
45
-
-
320.012.5
320.016.5
320.020.5
320.026.5
320.035.5
320.040.5
EN 50086 CLASSIFICATION* 1
Compression
Impact
Min.
Max.
Bending
Electrical
Resistance to ingress
resistance
resistance
temp.
temp.
resistance
properties
of solid objects
4
Heavy
4
(1250 N)
E.F.
Heavy
4 -25°C 1+ +70°C 4
(6 J)
I
Flexible 3*2 With electrical 6
Dust-tight
Resistance to
ingress
P
of water
7 Protected against the
continuity and
effects of temporary
insulating
immersion in water;
characteristics
4
O.R.
Heavy
(1250 N)
4
Heavy
3 -15°C
(6 J)
2 +100°C 4
Flexible 3*2 With electrical 6
1 m deep, 30 min.
Dust-tight
7 Protected against the
continuity and
effects of temporary
insulating
immersion in water;
characteristics
1 m deep, 30 min.
* 1 Classification according to EN 50086 is done in combination with the fittings (see catalogue) and also counts as a minimum for the complete range of
sizes. Though, for some size in the range a higher classification is possible--> consult your Anamet representative for more information.
* 2 Fitting non-insulating.
33
* 3 Based on stainless steel fittings (with standard fittings, class 2 counts for the whole system).
* 4 Dynamic application only at temperatures above 0°C.
ANACONDA SEALTITE ®
2"
2.1/2"
3"
4"
M63
-
-
-
48
-
-
-
2"
2.1/2"
3"
4"
51,6
63,3
78,4
102,1
Anaconda Sealtite ® represents the top of our range. The construction of this conduit consists of a robust
galvanised square-locked core with cord-packing and a thermoplastic cover. This proven construction method
ensures secure attachment of core and cover for long life and performance. Over 50 years of field experience
attests to the quality and durability of Sealtite ® conduits.
E.F.:
universal
Type E.F. is the most universal applicable Anaconda Sealtite ® conduit. The E.F. is meant for applications
59,9
72,6
88,4
where no extreme external parameters have influence on the conduit and therefore E.F. can be used in many
113,8
areas. The E.F. is, among others, being used in glass-producing-companies, paper-recycling industry, internal
210
280
425
490
transport-systems and the train-building industry. With VDE approval for the sizes 3/8” till 1 1/4” and DEMKO,
300
360
520
600
NEMKO, SEMKO and SETI approval for the sizes 3/8” till 2”.
Construction
: galvanised steel core, square-locked with cord packing, thermoplastic (PVC
Temperature
: -25ºC to +70ºC, intermittent up to +90ºC.
Colour
: black & grey.
oil & grease
15
7,5
7,5
7,5
311.050.1
311.063.1
311.075.1
311.100.1
315.050.1
315.063.1
315.075.1
315.100.1
compound) cover.
-
-
-
-
-
-
-
-
-
-
-
-
22
-
-
-
311.050.5
-
-
-
51,6
63,3
78,4
102,1
O.R.:
59,9
72,6
88,4
113,8
As a result of the high resistance against these substances the flexibility of the conduit is being safeguarded.
210
280
425
490
300
360
520
600
industry. With DEMKO, NEMKO, SEMKO and SETI approval for the sizes 3/8” till 2”.
Construction
: galvanised steel core, square-locked with cord packing, thermoplastic
Temperature
: -15ºC to +100ºC, intermittent up to +120ºC.
Colour
: black.
315.050.5
15
7,5
7,5
7,5
320.050.1
320.063.1
320.075.1
320.100.1
22
-
-
-
320.050.5
-
-
-
Anaconda Sealtite ® O.R. is preferred in areas where conduit systems are being exposed to oils and greases.
With other (non resistant) covers these substances can lead to stiffening or even rupture of the cover. Type
O.R. is being applied in the machine-building industry, diesel-engines, paper, chemical and petrochemical
(PVC compound) cover.
Corrosion
Tensile
Resistance to
Suspended
resistance
strength
flame propagation
load capacity
inside/outside
3* 3
Medium/
4
high
3* 3
Medium/
high
Heavy
1
(1000 N)
4
Heavy
(1000 N)
Non-flame
0
propagating
1
Non-flame
propagating
None
declared
0
None
declared
ANACONDA SEALTITE® conduit systems
Trade size Sealtite
inch
1/4"
5/16"
3/8"
1/2"
3/4"
1"
1.1/4"
1.1/2"
Fittings
ISO
M12
M16/M20
M16
M20
M25
M32
M40
M50
PG
7
9
11/13,5
16
21
29
36
42
NPT
-
-
1/2"
1/2"
3/4"
1"
1.1/4"
1.1/2"
Inside diameter
mm
6,4
10,1
12,6
16,0
21,0
26,5
35,1
40,3
Outside diameter
mm
11,5
14,4
17,8
21,1
26,4
33,1
41,8
47,8
Type H.C.
Type H.C.
Bending radius
static
mm
40
50
60
75
90
120
135
165
(centerline)
dynamic
mm
50
65
85
110
140
170
215
250 *4
Standard carton
m
Article no.
250
250
75
60
50
30
30
15
317.006.1
317.010.1
317.012.1
317.016.1
317.020.1
317.026.1
317.035.1
317.040.1
Reel
m
-
-
250
150
120
90
60
45
Article no. black
-
-
317.012.5
317.016.5
317.020.5
317.026.5
317.035.5
317.040.5
317.050.5
Inside diameter
mm
-
-
12,6
16,0
21,0
26,5
35,1
40,3
Outside diameter
mm
-
-
17,8
21,1
26,4
33,1
41,8
47,8
Type H.C.X.
Type H.C.X.
Bending radius
static
mm
(centerline)
dynamic
mm
-
-
m
-
-
30
30
30
30
15
15
-
-
326.012.1
326.016.1
326.020.1
326.026.1
326.035.1
326.040.1
Standard carton
Article no. black
60
75
90
120
135
165
85
110
140
170
215
250
EN 50086 CLASSIFICATION* 1
Compression
Impact
Min.
Max.
Bending
Electrical
Resistance to ingress
resistance
resistance
temp.
temp.
resistance
properties
of solid objects
4
4
(1250 N)
H.C.
4
H.C.X.
Heavy
Heavy
(1250 N)
Heavy
5 -45°C
3 +105°C 4
(6 J)
4
Heavy
5+ -55°C 4+ +145°C 4
(6 J)
I
Flexible 3*2 With electrical 6
Dust-tight
Resistance to
ingress
P
of water
7 Protected against the
continuity and
effects of temporary
insulating
immersion in water;
characteristics
Flexible 3*2 With electrical 6
Dust-tight
1 m deep, 30 min.
7 Protected against the
continuity and
effects of temporary
insulating
immersion in water;
characteristics
1 m deep, 30 min.
* 1 Classification according to EN 50086 is done in combination with the fittings (see catalogue) and also counts as a minimum for the complete range of
sizes. Though, for some size in the range a higher classification is possible--> consult your Anamet representative for more information.
* 2 Fitting non-insulating.
35
* 3 Based on stainless steel fittings (with standard fittings, class 2 counts for the whole system).
* 4 Dynamic applications only at temperatures above 0°C.
2"
2.1/2"
3"
4"
M63
-
-
-
48
-
-
-
2"
2.1/2"
3"
4"
51,6
63,6
78,4
102,1
H.C.:
59,9
72,6
88,4
113,8
strength at both high as low temperatures. Type H.C. can be used in areas where strong temperature changes
210
280
425
490
300 *4
360 *4
520 *4
600 *4
15
7,5
7,5
7,5
317.050.1
317.063.1
317.075.1
317.100.1
22
-
-
-
-
-
-
-
51,6
-
-
wide temperature range
In case we have to cope with high temperatures, than the H.C. is the better choice. The cover keeps its
occur. The H.C. can be found in transformers, the train-building industry, foundry, ceramic and materials and
concrete industry. With NEMKO, DEMKO, SEMKO, en SETI approval for the sizes 3/8” till 2”.
Construction
: galvanised steel core, square-locked with cord packing, thermoplastic (PVC
Temperature
: -45ºC tot +105ºC, intermittent up to +120ºC.
Colour
: black.
H.C.X.:
extreme temperatures
compound) cover.
-
Extreme cold, heat or temperature changes are conditions in which the H.C.X. performs the best. The cover of
59,9
-
-
-
210
-
-
-
300
-
-
-
15
-
-
-
326.050.1
-
-
-
this conduit has both a very high as low temperature resistance, which also ensures that changes in the
temperature are not being transferred to the electrical wiring. The H.C.X. keeps its flexibility at low
temperatures. Type H.C.X. is often used in the train-building and foundry industry and in cybernetics.
Corrosion
Tensile
Resistance to
Suspended
resistance
strength
flame propagation
load capacity
Medium/
4
high
3*3
Medium/
high
Heavy
1
(1000 N)
4
Heavy
(1000 N)
Non-flame
0
propagating
2
: galvanised steel core, square-locked with cord packing, thermoplastic
Temperature
: -55ºC tot +145ºC, intermittent up to +160ºC.
Colour
: black.
(elastomer) cover.
inside/outside
3*3
Construction
Flame
propagating
None
declared
0
None
declared
ANACONDA SEALTITE® conduit systems
Trade size Sealtite
inch
1/4"
5/16"
3/8"
1/2"
3/4"
1"
1.1/4"
1.1/2"
Fittings
ISO
M12
M16/M20
M16
M20
M25
M32
M40
M50
PG
7
9
11/13,5
16
21
29
36
42
NPT
-
-
1/2"
1/2"
3/4"
1"
1.1/4"
1.1/2"
Inside diameter
mm
-
10,1
12,6
16,0
21,0
26,5
35,1
-
Outside diameter
mm
-
14,4
17,8
21,1
26,4
33,1
41,8
-
Type Z.H.L.S.
Type Z.H.L.S.
Bending radius
static
mm
-
50
60
75
90
120
135
-
(centerline)
dynamic
mm
-
65
85
110
140
170
215
-
Standard carton
m
Article no. grey
-
30
30
30
30
30
15
-
-
308.010.1
308.012.1
308.016.1
308.020.1
308.026.1
308.035.1
-
Type H.F.X.
Type H.F.X.
Inside diameter
mm
-
10,1
12,6
16,0
21,0
26,5
35,1
-
Outside diameter
mm
-
14,4
17,8
21,1
26,4
33,1
41,8
-
Bending radius
static
mm
-
50
60
75
90
120
135
-
(centerline)
dynamic
mm
-
65
85
110
140
170
215
-
m
-
50
30
30
30
30
15
-
-
331.010.1
331.012.1
331.026.1
331.035.1
-
Standard carton
Article no. black
331.016.1 331.020.1
EN 50086 CLASSIFICATION* 1
Compression
Impact
Min.
Max.
Bending
Electrical
Resistance to ingress
resistance
resistance
temp.
temp.
resistance
properties
of solid objects
4
Heavy
4
(1250 N)
Z.H.L.S.
Heavy
5+ -50°C 4+ +125°C 4
(6 J)
I
Flexible 3*2 With electrical 6
Dust-tight
H.F.X.
Heavy
(1250 N)
4
Heavy
(6 J)
4+ -40°C
3 +105°C 4
ingress
P
of water
7 Protected against the
continuity and
effects of temporary
insulating
immersion in water;
characteristics
4
Resistance to
Flexible 3*2 With electrical 6
1 m deep, 30 min.
Dust-tight
7 Protected against the
continuity and
effects of temporary
insulating
immersion in water;
characteristics
1 m deep, 30 min.
* 1 Classification according to EN 50086 is done in combination with the fittings (see catalogue) and also counts as a minimum for the complete range of
sizes. Though, for some size in the range a higher classification is possible--> consult your Anamet representative for more information.
37
* 2 Fitting non-insulating.
* 3 Based on stainless steel fittings (with standard fittings, class 2 counts for the whole system).
2"
2.1/2"
3"
4"
M63
-
-
-
48
-
-
-
2"
2.1/2"
3"
4"
-
-
-
-
Z.H.L.S.:
halogen free & low smoke*
A halogen free, ‘low smoke’ conduit for use in public areas. The features of the Z.H.L.S. cover are necessary
-
-
-
in the field of environment and safety, as the European guidelines state that certain areas need to be free of
-
halogens. The Z.H.L.S. is optimal for use in the subway, train and bus-building industry, in closed areas,
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
airports, tunnels and (subway) stations
Construction
: galvanised steel core, square-locked with cord packing, thermoplastic (rubber)
Temperature
: -50ºC tot +125ºC, intermittent up to +140ºC.
Colour
: grey.
cover.
* Test results with regard to smoke development and harmful gases in case of fire, on request.
-
-
-
H.F.X.:
-
halogen free & very flexible
A halogen free conduit for use in public areas. The features of the H.F.X. cover are necessary in the field of
environment and safety, as the European guidelines state that certain areas need to be free of halogens.
-
-
-
-
-
-
-
-
makes the H.F.X. very suitable for installations, which are subject to frequent movements. The H.F.X. is often
-
-
-
-
being applied in the subway, train and bus-building industry, in closed areas, airports, tunnels and
Another unique feature of the H.F.X. is, that it is extremely flexible at both high as low temperatures. This
(subway)stations
-
-
-
-
-
-
-
-
Construction
: galvanised steel core, square-locked with cord packing, thermoplastic
Temperature
: -40ºC tot +105ºC, intermittent up to +125ºC.
Colour
: black.
(polyurethane) cover.
Corrosion
Tensile
Resistance to
Suspended
resistance
strength
flame propagation
load capacity
inside/outside
3*3
Medium/
4
high
3*3
Medium/
high
Heavy
1
(1000 N)
4
Heavy
(1000 N)
Non-flame
0
propagating
1
Non-flame
propagating
None
declared
0
None
declared