Ventilation grille PA Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63 - 980 - 0 Fax +49 (0) 74 63 - 980 - 200 [email protected] www.schako.de Ventilation Grille PA Contents Description ........................................................................................................................................ 3 Construction .............................................................................................................................................................................. 3 Model ......................................................................................................................................................................................... 3 Accessories ................................................................................................................................................................................ 4 Fastening ................................................................................................................................................................................... 4 Models and dimensions ......................................................................................................................... 5 for wall and ceiling mounting and installation in ventilation ducts ............................................................................................. 5 for floor mounting ...................................................................................................................................................................... 9 Dimensions of accessories ................................................................................................................... 14 Fastening methods ................................................................................................................................................................... 21 Technical data .................................................................................................................................. 23 Pressure loss and noise level ................................................................................................................................................... 23 Maximum end velocity of jet .................................................................................................................................................... 25 Jet path .................................................................................................................................................................................... 26 Critical throw ........................................................................................................................................................................... 27 Maximum penetration .............................................................................................................................................................. 28 Induction ratios and temperature ratios ................................................................................................................................... 29 Minimum distances ................................................................................................................................................................. 30 Legend ........................................................................................................................................... 30 Order details .................................................................................................................................... 31 Order details .................................................................................................................................... 32 Specification texts .............................................................................................................................. 34 01/14 - 2 Construction subject to change. Version: 17.07.2015 No return possible! Ventilation Grille PA Description Model The ventilation grille PA is suitable for use in supply and return air installations and for installation in walls, ceilings, floors and ventilation ducts. For air deflection, horizontal or vertical (for floors only), fixed blade profiles are attached at the front side. For wall mounting, basic type PA...-1 with concealed mounting (-VM, standard) or screw mounting (-SM) is suitable. The basic type PA...-3 with concealed mounting (-VM) and the model PA-R with concealed mounting (-VM) are suitable for floor installation. According to the required air throw pattern, the blade profile of the basic types PA..-1 and PA...-3 can be selected from three different blade profiles (PAZ standard, PAG and PAS). The louvre spacing of basic types PA...-1 and PA...-3 for nonwalk-on and non-ball-impact-resistant use is 13 mm (standard), while for walk-on and ball-impact-resistant use (acc. to DIN 18032, Part 3), for PA...-1 with screw mounting (-SM) only or for PA...-3 with concealed mounting (-VM) only it is 8 mm. The louvre spacing for model PA-R with roll-down grille is 10 mm. The blade insert can be removed for cleaning purposes. At an extra charge, a plenum box (for PA...-1 / PA...-2a only) can be mounted (only available without hit-and-miss damper). The damper in the adapter of the plenum box (at an extra charge) is used for simple air volume regulation. The technical data apply to all models. PA...-1 Construction Louvre grid - Blade profile: PAZ (standard), PAG, PAS - Louvre spacing: - 13 mm (non-walk-on, non-ball-impact-resistant, standard) - 8 mm (walk-on, ball-impact-resistant acc. to DIN 18032 Part 3) - Blades made of extruded aluminium profile, natural colour anodised (E6/EV1), at an extra charge specially anodised or painted. Roll-down grille PA-R - Profiled blades made of anodised natural colour aluminium (E6/EV1) - Blade connector consisting of plastic Frame - Extruded aluminium profile, natural colour anodised (E6/ EV1), at an extra charge specially anodised or painted. hit-and-miss damper - made of electrolytically galvanised sheet steel Droplet-forming blade - made of extruded aluminium profile, natural colour anodised (E6/EV1), at an extra charge specially anodised or painted. PA...-2a PA...-2b PA...-2c - PA...-10 - PA...-3 PA...-5 PA...-6 - PA...-7 ...Z - ...G ...S ...-13 - ...-8 - PA-R - Note: For walk-on floor-mounted grilles in band design, which are used in wet areas (e.g. swimming pools, barefoot areas), SCHAKO recommends the roll-down grille PA-R. 01/14 - 3 Construction subject to change. front-side horizontal fixed blade profiles for wall mounting, ceiling mounting and installation in ventilation ducts same as PA...-1, additionally with individually adjustable vertical droplet-forming blades same as PA...-1, additionally with hit-and-miss damper same as PA...-1, additionally with individually adjustable vertical droplet-forming blades and hit-andmiss damper Supply air and return air grilles, front-side, horizontal, fixed blade profiles, with narrow frame profile, for wall, ceiling and ventilation duct installation removable blade insert consisting of horizontal, fixed blade profiles for floor installation same as PA...-3, additionally with individually adjustable vertical droplet-forming blades same as PA...-3, additionally with individually adjustable vertical droplet-forming blades and hit-andmiss damper same as PA...-3, additionally with hit-and-miss damper Blade profile lightweight model, diagonal throw (standard) Blade profile compact model, straight throw Blade profile compact model, diagonal throw Louvre spacing 13 mm (standard), non-walk-on, non-ball-impact-resistant Louvre spacing 8 mm, walk-on, ball-impact-resistant according to DIN 18032 Part 3. PA-1 to PA-2c only with screw mounting (-SM) and PA-3 to PA-7 only with concealed mounting (-VM). Roll-down grille made of vertical fixed profiled blades for floor installation, walk-on, louvre spacing 10 mm, as band design. Version: 17.07.2015 No return possible! Ventilation Grille PA Accessories Fastening Plenum box (-ASK) (only for PA...-1 / PA...-2a / PA...-10) - Galvanised sheet steel - with connection pipe: - sideways (-AS1, standard) - from above (AS2) - front side (-AS3) Damper (-DK, for ASK-AS1) - in plenum box - Damper made of galvanised sheet steel - Damper fastening made of plastic Rubber lip seal (-GD) - Special rubber, on plenum box adapter Corner angle 90° (-ES) - with dummy plate made of galvanised sheet steel painted to RAL 9005 (black) (only for PA...-3 / PA...-5 / PA...-6 / PA...7/ PA-R-RP) - with dummy plate made of Zincor painted to RAL 9005 (black) (only for PA...-1 / PA...-2a / PA...-2b / PA...-2c / PA...-10) Mounting frame (-E1) - Galvanised sheet steel (only for PA...-1 / PA...-2a / PA...-2b / PA...-2c). insulation - inside (-Ii), thermal insulation at the inside of the plenum box - outside (-Ia), thermal insulation at the outside of the plenum box Frame (-RP, for PA-R only) - Extruded aluminium profile, natural colour anodised (E6/ EV1) - with 2-mm compensator made of extruded aluminium profile, natural colour anodised (E6/EV1) - with hit-and-miss damper (-SS), made of electrolytically galvanised sheet steel. Screw mounting (-SM) - PA...-1 / PA...-2a / PA...-2b / PA...-2c - Band design - Screws must be provided on-site Concealed mounting (-VM, standard) - PA...-1 / PA...-2a / PA...-2b / PA...-2c (-VM12, standard) - PA...-1 / PA...-2a / PA...-2b / PA...-2c (-VM11 + E1 at an extra charge) - PA...-3 / PA...-5 / PA...-6 / PA...-7 - Band design - PA-R - PA-10 (-VM10) Profiled blade design and spacing PAZ (standard) PAS PAG Mounting type x 13 mm Standard: non-walk-on non-ball-impact-resistant walk-on 8 mm ball-impact-resistant When ordering, the X dimension must be specified! PA-R Droplet-forming blade adjustable (for PA...-2a / PA...-2c / PA...-5 / PA...-6) 01/14 - 4 Construction subject to change. Version: 17.07.2015 No return possible! Ventilation Grille PA Models and dimensions for wall and ceiling mounting and installation in ventilation ducts Dimensions PA...-1-VM All models consist of basic type PA...-1 PA...-2a PA...-2b PA...-2c Frame profile PA...-1 / PA...-2a / PA...-2b / PA...-2c Available sizes L 325 425 525 625 825 1025 1225 L1 348 448 548 648 848 1048 1248 L2 304 404 504 604 804 1004 1204 L3 310 410 510 610 810 1010 1210 H H1 H2 H3 H4 75 125 225 325 102 152 252 352 58 108 208 308 65 115 215 315 60 110 210 310 All combined lengths and heights available (except H=325 with L=325)! Other sizes available on request. PLA = number of profiled blades 01/14 - 5 Construction subject to change. PLA 8 mm 13 mm 3 2 7 5 14 10 21 16 Version: 17.07.2015 No return possible! Ventilation Grille PA Ventilation grille PA...-1 / PA...-2a / PA...-2b / PA...-2c, as band 2-part if length of band BL ≤ 2025 mm multi-part for a length of band BL > 2025 mm Ventilation grille bands can be supplied only with screw mounting (SM). Fishplate (VL) Standard for band design 01/14 - 6 Construction subject to change. ES DIF TS BL BL1 = = = = = End piece Difference Section(s) Length of band Total length Version: 17.07.2015 No return possible! Ventilation Grille PA Dimensions PA...-10-VM M4x80 for model with counter pole brace M4x20 for model with plenum box Counter pole brace on-site Available sizes Frame profile PA...-10 L 210 310 410 510 610 810 1010 1210 L1 220 320 420 520 620 820 1020 1220 L2 205 305 405 505 605 805 1005 1205 H H1 H2 65 115 215 315 74 124 224 324 57 107 207 307 PLA 8 mm 13 mm 3 2 7 5 14 10 21 16 All combined lengths and heights available Other sizes available on request. Hit-and-miss damper not possible. PLA = number of profiled blades 01/14 - 7 Construction subject to change. Version: 17.07.2015 No return possible! Ventilation Grille PA Ventilation grille types PA...-10, as band 2-part if length of band BL ≤ 2025 mm multi-part for a length of band BL > 2025 mm Ventilation grille bands can be supplied only with concealed mounting (-VM10). Connecting piece (VS) Standard for band design ES DIF TS BL BL1 As-delivered condition = = = = = End piece Difference Section(s) Length of band Total length Note: The connecting piece is folded down manually on-site. 01/14 - 8 Construction subject to change. Version: 17.07.2015 No return possible! Ventilation Grille PA for floor mounting Dimension PA...-3-VM All models consist of basic type PA...-3 PA...-5 PA...-6 PA...-7 Available sizes L 325 425 525 625 825 1025 1225 L1 348 448 548 648 848 1048 1248 L2 304 404 504 604 804 1004 1204 L3 310 410 510 610 810 1010 1210 H H1 H2 H3 H4 75 125 225 325 102 152 252 352 58 108 208 308 65 115 215 315 60 110 210 310 PLA 8 mm 13 mm 6 4 10 7 17 12 25 18 All combined lengths and heights available (except H=325 with L=325)! Other sizes available on request. PLA = number of profiled blades Frame profile PA...-3 / PA...-5 / PA...-6 / PA...-7 Grille insert fastening (standard model) 01/14 - 9 Construction subject to change. Version: 17.07.2015 No return possible! Ventilation Grille PA Ventilation grille PA...-3 / PA...-5 / PA...-6 / PA...-7, as band 2-part if length of band BL ≤ 2025 mm multi-part for a length of band BL > 2025 mm ES DIF TS BL = = = = End piece Difference Section(s) Length of band Ventilation grille bands can be supplied only with concealed mounting (-VM). Fishplate (VL) Standard for band design Note: For walk-on floor-mounted grilles in band design, which are used in wet areas (e.g. swimming pools, barefoot areas), SCHAKO recommends the roll-down grille PA-R. 01/14 - 10 Construction subject to change. Version: 17.07.2015 No return possible! Ventilation Grille PA PA-R (Roll-down grille) In order to reach the full load-carrying capacity, an on-site centre support for the roll-down grille must take place for H=325. To facilitate on-site mounting, the roll-down grille insert can be divided into individual lengths. Available sizes H 75 125 225 325 H5 91 141 241 341 Technical handling, chemical and mechanical resistance see Page°13. Roll-down grille length: max. 10m Note: This grille version is perfect for wet areas (e.g. swimming pool, barefoot areas). Accessories: PA-R-RP, with frame as band 2-part if length of band BL ≤ 2025 mm ES DIF TS BL = = = = End piece Difference Section(s) Length of band multi-part for a length of band BL > 2025 mm Available sizes PA-R-RP Frame profile PA-R-RP / PA-R-RP-SS H H1 H2 75 102 58 125 152 108 225 252 208 325 352 308 End pieces ≤ 325 not available for H = 325. Compensator 2 mm Note: The roll-down grille is placed loosely in the frame. Ventilation grille bands can be supplied only with concealed mounting (-VM). Fishplate (VL) for band design, see page 8. 01/14 - 11 Construction subject to change. Version: 17.07.2015 No return possible! Ventilation Grille PA PA-R-RP-SS, with frame and hit-and-miss damper as band 2-part if length of band BL ≤ 2025 mm ES = End piece DIF = Difference TS = Section(s) hit-and-miss SS = damper BL = Length of band multi-part for a length of band BL > 2025 mm Available sizes PA-R-RP-SS H H1 H4 75 102 60 125 152 110 225 252 210 325 352 310 End pieces ≤ 325 not available for H = 325. Attention! The hit-and-miss damper (-SS) is not suitable for wet areas (e.g. swimming pool, barefoot areas)! 01/14 - 12 Construction subject to change. Version: 17.07.2015 No return possible! Ventilation Grille PA PA-R (Roll-down grille) Technical handling Use: Resistance: Safety: The roll-down grille is suitable for transit areas of residential and office buildings. Its resistance and load bearing capacity are such that they fulfil the requirements of permanent and daily use. The chemical, thermal and mechanical resistances of the roll-down grille were tested and showed that it is also UV-resistant. This grille is perfect for wet areas (e.g. swimming pool, barefoot areas) and can be cleaned in dishwashers (up to 60°C). The integrated cutting edge cover reduces the risk of injuries and prevents rattling in case of lateral play. Due to its anti-slip design, it is safe to walk on. Chemical and mechanical resistance The quality requirements for daily use were proven for all surface types in several test series (based on requirements of standards and regulations); they have been verified for the following chemical and mechanical resistances: - Coating thickness to ISO 2360 (DIN 50984) - Cross-cut test to ISO 2409 (DIN 53151): GT0 - Buchholz indentation test to ISO 2815 (DIN 53153) - Ball impact test according to ASTM D 2794 - Boiling test according to GSB procedure (organization for quality surface coating) - Resistance to chlorine and salt compounds, e.g. in swimming pools - Cleaning with standard cleaning agents - Dishwasher-proof (up to 60°C) - UV-resistant 01/14 - 13 Construction subject to change. Version: 17.07.2015 No return possible! Ventilation Grille PA Dimensions of accessories out- for wall and ceiling mounting and installation in ventilation ducts Plenum box (-ASK) with lateral connection piece (-AS1) for PA...-1 / PA...-2a only With fixing lugs Grilles cannot be fitted with a hit-and-miss damper if a plenum box is attached, i.e., it can either be fitted with a hit-and-miss damper or a plenum box. Available sizes ASK -AS1 L 325 425 525 625 825 1025 1225 L 325 425 525 625 825 1025 1225 H 75 H 125 KL 320 420 520 620 820 1020 1220 H1 KL 320 420 520 620 820 1020 1220 H1 68 118 KH 210 210 210 210 245 245 245 øD 123 123 123 123 158 158 158 L 325 425 525 625 825 1025 1225 KH 245 245 245 245 285 285 285 øD 158 158 158 158 198 198 198 L 325 425 525 625 825 1025 1225 01/14 - 14 Construction subject to change. H 225 H 325 KL 320 420 520 620 820 1020 1220 KL 320 420 520 620 820 1020 1220 H1 218 H1 318 KH 285 285 285 335 335 335 335 øD 198 198 198 248 248 248 248 KH 335 335 335 400 400 400 400 øD 248 248 248 313 313 313 313 Version: 17.07.2015 No return possible! Ventilation Grille PA Insulation for plenum box internal (-Ii) Arrangement of connecting pieces - Lateral connecting piece (-AS1, standard) - Connecting piece from above (-AS2) - Connecting piece front side (-AS3) Dimensions and prices for connecting piece from above (-AS2) and connection piece front side (-AS3) upon request. Detail X outside(-Ia) Concealed plates can be bent outwards, if necessary. Damper (-DK) Rubber lip seal (-GD) Detail Y 01/14 - 15 Construction subject to change. Version: 17.07.2015 No return possible! Ventilation Grille PA Plenum box (-ASK) with lateral connection piece (-AS1) as for PA...-1 / PA...-2a only 2-part if length of band BL < 2025 mm band ES = DIF = TS = BL = BL1 = KL = KL1 = n = -17 End piece Difference Section(s) Length of band Total length of grille (BL1 = BL + 23) Length of box Length of box end piece (KL1 = ES - 17) Number of multi-part for a length of band BL > 2025 mm -17 01/14 - 16 Construction subject to change. Version: 17.07.2015 No return possible! Ventilation Grille PA Available sizes ASK -AS1 only for PA-10 Plenum box (-ASK) with lateral connection piece (-AS1) only for PA...-10 outside L 210 310 410 510 610 810 1010 1210 L 210 310 410 510 610 810 1010 1210 Arrangement of connecting pieces - Lateral connecting piece (-AS1, standard) - Connecting piece from above (-AS2) - Connecting piece front side (-AS3) Dimensions and prices for connecting piece from above (-AS2) and connection piece front side (-AS3) upon request. Damper (-DK) Rubber lip seal (-GD) Detail Y Insulation for plenum box internal (-Ii) outside(-Ia) L 210 310 410 510 610 810 1010 1210 L 210 310 410 510 610 810 1010 1210 01/14 - 17 Construction subject to change. H 65 H 115 H 215 H 315 KL 208 308 408 508 608 808 1008 1208 H1 KL 208 308 408 508 608 808 1008 1208 H1 KL 208 308 408 508 608 808 1008 1208 KL 208 308 408 508 608 808 1008 1208 63 113 H1 213 H1 313 KH 210 210 210 210 245 245 245 245 øD 123 123 123 123 158 158 158 158 KH 245 245 245 245 245 285 285 285 øD 158 158 158 158 158 198 198 198 KH 285 285 285 285 335 335 335 335 øD 198 198 198 198 248 248 248 248 KH 335 335 335 335 400 400 400 400 øD 248 248 248 248 313 313 313 313 a 106 a 138 a 180 a 230 Version: 17.07.2015 No return possible! Ventilation Grille PA Plenum box (-ASK) with lateral connecting piece (-AS1) as only for PA...-10 2-part if length of band BL < 2025 mm band ES = DIF = TS = BL = BL1 = KL = KL1 = n = End piece Difference Section(s) Length of band Total length of grille (BL1 = BL + 10) Length of box Length of box end piece (KL1 = ES - 9) Number of multi-part for a length of band BL > 2025 mm 01/14 - 18 Construction subject to change. Version: 17.07.2015 No return possible! Ventilation Grille PA for wall and ceiling mounting and installation in ventilation ducts Corner angle (-ES-1) for ventilation grille band PA...-1 / PA...-2a / PA...-2b / PA...2c for floor mounting Corner angle (-ES-3) for ventilation grille band PA...-3 / PA...-5 / PA...-6 / PA...-7 Dummy plate Dummy plate Corner angles can only be manufactured as dummy plates, i.e., without a plenum box. The corner angle is angled by 90° and has a flange length of 450 mm. The dummy piece used is made of Zincor and painted to RAL 9005 (black). Corner angles can only be manufactured as dummy plates, i.e., without a plenum box. The corner angle is angled by 90° and has a flange length of 450 mm. The dummy plate used is made of galvanised sheet steel and painted to RAL 9005 (black). Corner angle (-ES-R) for ventilation grille band PA-R-RP / PA-R-RP-SS Corner angle (-ES-10) for ventilation grille band PA...-10 Dummy plate Dummy plate Corner angles can only be manufactured as dummy plates, i.e., without a plenum box. The corner angle is angled by 90° and has a flange length of 436 mm. The dummy piece used is made of Zincor and painted to RAL 9005 (black). Corner angles can only be manufactured as dummy plates, i.e., without a plenum box. The corner angle is angled by 90° and has a flange length of 450 mm. The dummy plate used is made of galvanised sheet steel and painted to RAL 9005 (black). 01/14 - 19 Construction subject to change. Version: 17.07.2015 No return possible! Ventilation Grille PA Mounting frame (-E1) for wall and ceiling mounting and installation in ventilation ducts PA...-1 / PA...-2a / PA...-2b / PA...-2c Length L ≤ 825 mm Length L > 825 mm = 4 wall anchors = 6 wall anchors Mounting frame for ventilation grille band PA...-1 / PA...-2a / PA...-2b / PA...-2c 2-part, BL ≤ 2025 mm - 6 wall anchors several sections, BL > 2025 mm - 8 wall anchors BL MF SV MS ES DIF TS = = = = = = = Length of band Wall anchor Plug-in connection Assembly rail End piece Difference Section(s) Mounting frames for grille bands are supplied with plug-in connections. Assembly rails are additionally attached, they can be easily removed by turning, once the grille has been mounted in the wall. All frames are supplied without wall anchors. Wall anchors available at an extra charge only. 01/14 - 20 Construction subject to change. Version: 17.07.2015 No return possible! Ventilation Grille PA Fastening methods for wall and ceiling mounting and installation in ventilation ducts PA...-1 / PA...-2a / PA...-2b / PA...-2c Screw mounting (-SM) (drawn without grille insert) The ventilation grilles types PA...-1 / PA...-2a / PA...-2b / PA...2c are only supplied with screw mounting (SM) on special request. Only this model is walk-on and ball-impact-resistant (to DIN 18032, part 3). L<625 PA...-1 / PA...-2a / PA...-2b / PA...-2c / PA...-10 Concealed mounting (-VM) Unless stated otherwise, the ventilation grilles types PA...-1 / PA...-2a / PA...-2b / PA...-2c are delivered with concealed mounting (-VM12). The ventilation grille of type PA...-10 can only be delivered with concealed mounting (VM10). Starting from height 225/210 2 attachments per side. Indentation for slotted shallow-raised countersunk-head DIN ISO 7051 pitch 3.9 (on-site) VM 11 VM 12 L≥625 The concealed mounting VM 11 is only available with a mounting frame or plenum box. The mounting frame must be ordered separately. Band design End piece Indentation for slotted shallow-raised countersunk-head tapping screw DIN ISO 7051 pitch 3.9 (on-site) VM 10 1.) 2.) Section Concealed mounting VM 10 is possible only for the ventilation grille of type PA...-10 with a plenum box or counter pole brace (on site). End piece < 625 mm = 4 raised countersunk head tapping screws End piece ≥ 625 mm = 6 raised countersunk head tapping screws Section = 6 raised countersunk head tapping screws 1.) Riveting nut M4 2.) M4x20 for plenum box M4x80 with counter pole brace 01/14 - 21 Construction subject to change. Version: 17.07.2015 No return possible! Ventilation Grille PA for floor mounting PA...-3 / PA...-5 / PA...-6 / PA...-7 / PA-R-RP / PA-R-RP-SS Frame fixed by concealed mounting (-VM) (drawn without grille insert) PA...-3 / PA...-5 / PA...-6 / PA...-7 L = 325 - 525 Section A-A (drawn rotated by 90°) Fixed without wall anchors Indentation for slotted shallow-raised countersunk-head tapping screw DIN ISO 7051 pitch 3.9 (on-site) L = 625 - 1225 Fixed with wall anchors (Wall anchors at an extra charge) PA...-3 / PA...-5 / PA...-6 / PA...-7 / PA-R-RP / PA-R-RP-SS Band design End piece Indentation for slotted shallow-raised countersunk-head tapping screw DIN ISO 7051 pitch 3.9 (on-site) Length L ≤ 825 mm Length L > 825 mm = 4 wall anchors = 6 wall anchors Section End piece ≤ 425 mm= 4 raised countersunk head tapping screws End piece > 425 mm = 6 raised countersunk head tapping screws Section = 6 raised countersunk head tapping screws 01/14 - 22 Construction subject to change. Version: 17.07.2015 No return possible! Ventilation Grille PA Technical data The technical data apply to all models. Pressure loss and noise level Supply air without hit-and-miss damper Return air without hit-and-miss damper Supply air with hit-and-miss damper Return air with hit-and-miss damper 12 7 6 5 4 33vvKK (m/s) (m/s) Hit-and-miss damper position OPEN in % Face area Supply and return air Hit-and-miss damper position OPEN in % H Correction factor Supply and return air Astirn (m²) KF (-) 0,01 0,02 0,04 0,08 0,16 0,32 -9 -6 -3 0 +3 +6 LWA = LWA1 + KF 75 125 225 325 01/14 - 23 Construction subject to change. 325 0,016 0,031 0,061 0,091 425 0,021 0,041 0,081 0,121 L 525 625 825 0,026 0,031 0,042 0,051 0,061 0,082 0,101 0,122 0,162 0,151 0,182 0,242 Astirn (m²) 1025 0,052 0,102 0,202 0,303 1225 0,062 0,123 0,243 0,363 Version: 17.07.2015 No return possible! Ventilation Grille PA Front side velocity 01/14 - 24 Construction subject to change. Version: 17.07.2015 No return possible! Ventilation Grille PA Maximum end velocity of jet Supply air without coanda effect Supply air with coanda effect 01/14 - 25 Construction subject to change. Version: 17.07.2015 No return possible! Ventilation Grille PA Jet path Supply air without coanda effect Heating Cooling 01/14 - 26 Construction subject to change. Version: 17.07.2015 No return possible! Ventilation Grille PA Critical throw Supply air with coanda effect 01/14 - 27 Construction subject to change. Version: 17.07.2015 No return possible! Ventilation Grille PA Maximum penetration In heating mode Supply air without coanda effect 01/14 - 28 Construction subject to change. Version: 17.07.2015 No return possible! Ventilation Grille PA Induction ratios and temperature ratios Supply air without coanda effect Supply air with coanda effect 01/14 - 29 Construction subject to change. Version: 17.07.2015 No return possible! Ventilation Grille PA Minimum distances Supply air without coanda effect Supply air with coanda effect For the diagrams to be correct, the distance z between two grilles must be x (m) x 0.2 Legend VZU VAB VX vmax vK vstirn = = = = = = Astirn (m²) x (m) y (m) xkr (m) ρ (kg/m³) Δpt (Pa) LWA [dB(A)] = = = = = = = LWA1 [dB(A)] = KF (-) ΔTO (K) = = ΔTOH (K) = ΔTX tZUH tRH tZU tR i TV z (K) (°C) (°C) (°C) (°C) (-) (-) (m) = = = = = = = = RH RB H L (mm) (mm) (mm) (mm) = = = = 01/14 - 30 Construction subject to change. (m³/h) [l/s] (m³/h) [l/s] (m³/h) [l/s] (m/s) (m/s) (m/s) Supply air volume Return air volume Total air jet volume at point x Maximum end velocity of jet Duct velocity Intake velocity, blower stream velocity, outflow velocity, relative to Astirn Face area Horizontal throw Vertical throw Critical throw Density Pressure loss A-weighted sound power level [LWA = LWA1 + KF] A-weighted sound power level, relative to Astirn, = 0.08 m² Correction factor Temperature difference between supply air temperature and room temperature (ΔTO = tZU - tR) Temperature difference between air supply and room temperature in heating mode (ΔTOH = tZUH - tRH) Temperature ratio at position x Supply air temperature Room temperature Supply air temperature Room temperature Induction ratio (i = VX / VZU) Temperature ratio (TV = ΔTX / ΔTO) Minimum clearance between two grilles x (m) x 0.2 Room height Room width Height Length Version: 17.07.2015 No return possible! Ventilation Grille PA Order details Ventilation grille type PA for wall mounting, ceiling mounting and installation in ventilation ducts blade profiles horizontal / fixed Z G S Louvre spacing 8 mm 13 mm walk-on, ball-impact-resistant (acc. to DIN 18032, Part 3) For PA...-1 to PA...-2c only screw mounting possible. non-walk-on non-ball-impact-resistant with horizontal fixed blade profiles with horizontal fixed blade profiles additionally with vertical, individually adjustable droplet-forming blades with horizontal fixed blade profiles with hit-and-miss damper -1 -2a -2b with horizontal fixed blade profiles additionally with vertical, individually adjustable dropletforming blades and hit-and-miss damper with horizontal fixed blade profiles with narrow frame profile -2c -10 with concealed mounting with concealed mounting with screw mounting -SM (band design with screw mounting only) -VM11 (only available in conjunction with mounting frame E1 or plenum box) -VM10 -VM12 (available only in connection with plenum box or counter pole brace on-site) Length Length 325 425 525 625 825 1025 1225 2-part as band 210 310 410 510 610 810 1010 1210 as band multi-part 2-part (BL < 2025 mm) (BL > 2025 mm) multi-part (BL < 2025 mm) (BL > 2025 mm) Height Height (Height 325 not available with length 325) (Height 315 not available for length 310) 75 125 225 325 65 115 215 315 Order example: PAZ-13-1-VM12-525×125 Unless stated otherwise, the thick-frame model will be delivered! 01/14 - 31 Construction subject to change. Version: 17.07.2015 No return possible! Ventilation Grille PA Order details Ventilation grille type PA for floor mounting blade profiles horizontal / fixed Z G S Louvre spacing 8 mm 13 mm walk-on, ball-impact-resistant (acc. to DIN 18032, Part 3) non-walk-on non-ball-impact-resistant with horizontal fixed blade profiles -3 with with horizontal horizontal fixed fixed blade profiles blade profiles additionally additionally with with vertical, vertical, individually individually adjustable dropletadjustable forming droplet-forming blades and hit-andblades miss damper -5 -6 with horizontal fixed blade profiles with hit-and-miss damper -7 with concealed mounting -VM Length 325 425 525 625 825 1025 1225 as band 2-part multi-part (BL < 2025 mm) (BL > 2025 mm) Height (Height 325 not available with length 325) 75 125 225 325 Order example: PAZ-13-1-VM12-525×125 Unless stated otherwise, the thick-frame model will be delivered! 01/14 - 32 Construction subject to change. Version: 17.07.2015 No return possible! Ventilation Grille PA Accessories: Roll-down grille with vertical fixed profiled blades for floor installation, walk-on Louvre spacing 10 mm PA-R without frame - Mounting frame -E1 (only available for PA...-1 / PA...-2a / PA...-2b / PA...-2c) 2-part (BL ≤ 2025 mm) 1 piece with frame -RP Plenum box -ASK without with hit-and-miss damper hit-and-miss damper -SS (only for PA...-1 / PA...-2a / PA...-10 ) (only possible without hit-and-miss damper) as band Connection pipe 2-part multi-part (BL ≤ 2025 mm) (BL > 2025 mm) on the side -AS1 (Height 325 not available with length ≤ 325) 125 225 from above -AS2 front side -AS3 L = 310-1210 (PA...-10) L = 325-1225 (PA...-1 / PA...-2) Band Height 75 multi-part (BL > 2025 mm) 325 Order example: PA-R-RP-SS-10000 x 125 Unless stated otherwise, the thick-frame model will be delivered! without Damper - with Damper -DK without rubber lip seal - with rubber lip seal -GD without insulation with internal insulation with insulation outside Corner angle 90° -ES (with dummy plate) for PA...-1 / PA...-2a / PA...-2b / PA...-2c -1 01/14 - 33 Construction subject to change. for PA...-3 / PA...-5 / for for PA...-6 / PA...-7 PA-R-RP PA...-10 -R -10 -3 Version: 17.07.2015 No return possible! Ventilation Grille PA Specification texts Supply air and return air grilles for wall, ceiling and ventilation duct installation, consisting of front frame and blades made of extruded aluminium profiles natural colour anodised (E6/EV1) or specially anodised or painted at an extra charge. with front side horizontal fixed blade profiles, PAZ, lightweight model, diagonal throw. with louvre spacing 13 mm (non-ball-impact-resistant, non-walk-on) Fastening with concealed mounting (VM12). Product: SCHAKO type PAZ-1 Dimensions: Length ___________ mm Height ___________ mm Blade profile: - PAG, compact model, straight throw. - PAS, compact model, diagonal throw. Louvre spacing: Accessories: - with plenum box (-ASK) made of galvanised sheet steel (only possible without hit-and-miss damper) (for PA...-1 / PA...-2a only) - with connection pipe: - sideways (-AS1, standard) - from above (AS2) - front side (-AS3) - with damper (-DK, for ASK-AS1) in plenum box, adjustable, for simple air volume regulation. - with rubber lip seal (-GD), made of special rubber, at the connection pipe. - with thermal insulation - inside - outside - with mounting frame (-E1) - 1 piece - 2-part (BL ≤ 2025mm) - multi-part (BL > 2025mm) - Corner angle 90° (-ES-1) - 8 mm (walk-on / ball-impact-resistant to DIN 18032 Part 3), with screw mounting (-SM) only - additionally with individually adjustable vertical droplet-forming blades Product: SCHAKO type PA -2a - with hit-and-miss damper for air volume regulation, made of electrolytically galvanised sheet steel, Product: SCHAKO type PA -2b - additionally with individually adjustable vertical droplet-forming blades and hit-and-miss damper, for air volume regulation, made of electrolytically galvanised sheet steel. Product: SCHAKO type PA...-2c - as band: - 2-part (BL ≤ 2025mm) - multi-part (BL > 2025mm) - with concealed mounting VM11 (only available in connection with mounting frame E1 or plenum box) - with screw mounting (-SM) 01/14 - 34 Construction subject to change. Version: 17.07.2015 No return possible! Ventilation Grille PA Supply air and return air grilles for wall, ceiling and ventilation duct installation, consisting of a narrow front frame and blades made of extruded aluminium profiles natural colour anodised (E6/EV1) or specially anodised or painted at an extra charge. With front-side horizontal fixed blade profiles, PAZ, diagonal throw. with louvre spacing 13 mm (non-ball-impact-resistant, non-walkon) Fastening with concealed mounting (-VM10). Product: SCHAKO type PAZ-10 Dimensions: Length ___________ mm Height ___________ mm Blade profile: - PAG, compact model, straight throw. - PAS, compact model, diagonal throw. Accessories: - with plenum box (-ASK), made of galvanised sheet steel (only for PA...-10) - with connection pipe: - sideways (-AS1, standard) - from above (AS2) - front side (-AS3) - with damper (-DK, for ASK-AS1) in plenum box, adjustable, for simple air volume regulation. - with rubber lip seal (-GD), made of special rubber, at the connection pipe. - with thermal insulation - inside - outside - Corner angle 90° (-ES-10) Louvre spacing: - 8 mm (walk-on, ball-impact-resistant acc. to DIN 18032 Part 3) 01/14 - 35 Construction subject to change. Version: 17.07.2015 No return possible! Ventilation Grille PA Supply and return air grilles, especially for floor installation, consisting of front frame and blades made of extruded aluminium profiles natural colour anodised (E6/EV1) or specially anodised or painted at an extra charge, with removable blade insert made of horizontal fixed blade profiles PAZ, lightweight model, diagonal throw. with louvre spacing 13 mm (non-ball-impactresistant, non-walk-on) Fastened with concealed mounting (VM). Product: SCHAKO type PAZ-3 Roll-down grille in band design in particular for floor installation, consisting of vertical fixed profiled blades made of extruded aluminium profile natural colour anodised (E6/EV1), louvre spacing 10mm, walk-on. This grille is perfect for wet areas (e.g. swimming pool, barefoot areas). Blade connector made of plastic. Fastened with concealed mounting (-VM). Product: SCHAKO type PA-R Dimensions:: Length ___________ mm Height ___________ mm Dimensions: Length ___________ mm Height ___________ mm Accessories: Blade profile: - PAG, compact model, straight throw. - PAS, compact model, diagonal throw. Louvre spacing: - 8 mm (walk-on, ball-impact-resistant to DIN 18032 Part 3), with concealed mounting (-VM) only - with frame (-RP) and 2-mm compensator made of extruded aluminium profile, natural colour anodised (E6/EV1) - with hit-and-miss damper (-SS), made of electrolytically galvanised sheet steel. - as band: - 2-part (BL ≤ 2025mm) - multi-part (BL > 2025mm) - Corner angle 90° (-ES-R) - additionally with individually adjustable vertical droplet-forming blades Product: SCHAKO type PA...-5 - additionally with individually adjustable vertical droplet-forming blades and hit-and-miss damper, for air volume regulation, made of electrolytically galvanised sheet steel. Product: SCHAKO type PA...-6 - with hit-and-miss damper for air volume regulation, made of electrolytically galvanised sheet steel, Product: SCHAKO type PA...-7 - as band: - 2-part (BL ≤ 2025mm) - multi-part (BL > 2025mm) Accessories: - Corner angle 90° (-ES-3) 01/14 - 36 Construction subject to change. Version: 17.07.2015 No return possible!
© Copyright 2026 Paperzz