Thermo Scientific TSQ 8000 Evo Triple Quadrupole GC-MS/MS Expect more productivity with the evolution of ultimate performance GC-MS/MS Expect More Productivity Evolving with the changing laboratory environment The pressure on analytical laboratories has never been greater. Managers face a dynamic environment of changing regulatory requirements, lower detection levels, more compounds, less time, lower budgets and increased competition. Laboratories must evolve to stay ahead of the game, and their analytical systems need to evolve, too. The Thermo Scientific™ TSQ™ 8000 Evo Triple Quadrupole GC-MS/MS is for labs looking for the next step up in triple quadrupole GC-MS/MS productivity. It is the latest evolution of the highly successful TSQ 8000 GC-MS/MS system and the evolution of unstoppable productivity, MS/MS simplicity, and ultimate performance SRM. The TSQ 8000 Evo triple quadrupole GC-MS/MS has been designed for and developed with high throughput analytical laboratories. It is a unique system that offers a harmonious combination of hardware and software features that help laboratories adapt to their changing environment and deliver quality results on time, every time. 2 3 Expect More Capacity Fast EvoCell technology and intelligent instrument control More capacity is offered through the acquisition of more information, more compounds, and more results per unit time in your laboratory. This enables higher levels of productivity and efficiency in analytical workflows. Innovative EvoCell collision cell technology, in combination with the high efficiency timed-SRM capability of the TSQ 8000 Evo GC-MS/MS, opens the door to new possibilities for high-complexity methods in routine laboratories. Enhanced velocity optics driving EvoCell collision cell technology provide high SRM transition speeds, precision, and sensitivity for even the most complex methods 8 3 TSQ 8000 Evo GC-MS/MS Timed SRM • Complicated set-up • Automated set-up 0 • Wasted dwell time • Optimized dwell time • Reduced sensitivity • Maximized sensitivity • Reduced tolerance to RT shifts • Increased resistance to RT shifts lpe xo He xa Fo dio ha op Cy p 900 pr 800 lor 300 400 500 600 700 Transition Speed (MRM/Second) Ch 200 t F ch ural lor axy ob l en ze Me ne thi oc a Pir rb im ica rb Tr iad im en ol Traditional Segmented SRM 1 nil 2 m EvoCell Technology Older Cell Technology 100 Multiple single quadrupole pesticides methods consolidated into one 40-minute, 350 pesticides (700 transitions) run 4 50 0 5 Flu 100 Simply enter the retention time and the time required to capture the peak, and t-SRM takes care of the rest. This ensures that compound detection is optimized for maximum sensitivity, and more compounds can be added to the method without compromising the excellent sensitivity of each individual analyte. The mass spectrometer is not consuming valuable resources scanning for compounds at the times when those compounds are not eluting. 6 ini l DD E,p 150 As more compounds are added to a single run, managing acquisition windows becomes increasingly complex. The TSQ 8000 Evo GC-MS/ MS system dramatically reduces this complexity by automatically optimizing the targeting of a particular compound. 7 rod 200 3.5x sensitivity at faster acquisition speeds Bifenthrin Detection Limit (fg On Colum) Similar sensitivity at 4x transition speed 0 %RSD MDL (pg/ul) Calibration linearity (r2) 5-500ppb 9 250 Truly powerful methods use speed efficiently Increased sensitivity at fast transition speeds allows the use of up to 4x transition speeds of standard collision cell technology Analysis of pesticides in rice (10 µg/kg) with the EvoCell collision cell at 500 µs dwell time, acquiring 800 transitions per second EvoCell Collision Cell Technology Features Benefits Impact Increased number of transitions per compound More points of confirmation More resistance to matrix interference Higher confidence More on-time results Increased number of compounds Higher capacity methods More method consolidation More efficiency in result production Fast GC compatible Faster run times Faster turnaround More on-time results Wider SRM windows 4 More resistance to the effects of RT shift caused by matrix Faster turnaround More on-time results Traditional Segmented SRM TSQ 8000 Evo GC-MS/MS Timed SRM 5 Expect More Performance Ultimate sensitivity SRM Ultimate sensitivity for contaminants regulated at the lowest levels Laboratories performing analyses in food safety, environmental monitoring, and sports doping can all benefit from high selectivity and ultimate sensitivity selected reaction monitoring (SRM) enabled by the TSQ 8000 Evo GC-MS/MS, which is the highest performing triple quadrupole GC-MS/MS offered on the market. The confirmatory determination of polychlorinated dibenzodioxins and furans (PCDD/Fs) is one of the most challenging of the ultra-trace analytical methods in contaminant analysis. This challenge is due to the extremely low regulated levels and stringent analytical criteria in force. Meeting that challenge requires extremely powerful SRM that the TSQ 8000 Evo GC-MS/MS delivers routinely. TSQ 8000 Evo pesticide detection limits (1µL injection) 1 0.9 0.8 2,3,7,8-TCDD 319.89 > 256.93 Fish meal containing low levels of 2,3,7,8-TCDD 2,3,7,8-TCDD 321.89 > 258.93 13C 2,3,7,8-TCDD 331.94 > 267.97 0.7 parts-per-billion Detection limit (99% confidence level) of 166 pesticides based upon 0.5 and 1 ppb peak area precision (no internal standard correction) using 1 µL PTV injection (n=10) Fish meal 0.03 ng/kg 88% dw 0.6 13C 2,3,7,8-TCDD 333.93 > 269.97 0.5 0.4 0.3 0.2 Triallate Triticonazole Tolclofos-methyl Quintozene Tebufenpyrad Tetraconazole Propham Pyrifenox-Z Pirimicarb Oxadiazon Phosalone Pentachloroaniline Napropamide Linuron Mevinphos Isocarbamid Methoxychlor Furalaxyl Hexazinone Flusilazole Fenvalerate Flucythrinate Fenarimol Fenhexamid Etofenprox Etaconazole Diniconazole Endosulfan ssulfate Difenoconazole DDE o,p Dichlobenil Deltamethrin Cyfluthrin Cypermethrin Chlorothalonil Chlorthal-monomethyl Cadusafos Chlorfenson Atrazine 0.07 Instrument detection limit (IDL) for PCDD/Fs when satisfying all confirmatory criteria CSL x 5 dilution (n=10) injected using splitless mode 0.06 0.05 0.04 0.03 0.02 DDE p,p’ 5 µg/kg in green tea 0.01 Oxyfluorfen Calibration Curve 5 - 500 µg/kg in green tea High selectivity of low concentrations in complex tea matrix 23 DDE p,p’ Calibration Curve 5 - 500 µg/kg in green tea 78 -T CD 23 78 F 12 -TCD 37 D 8Pe 23 CD 47 F 812 PeC D 37 8- F Pe 12 34 CDD 78 12 -Hx C 36 78 DF 23 -Hx C 46 78 DF 12 -HxC 34 78 DF 12 -Hx C 36 78 DD 12 -HxC 37 DD 89 H 12 x 37 CDD 8 12 9-H x 34 67 CDF 12 8-H p 34 67 CDF 12 8-Hp 34 CD 78 D 9Hp CD F OC DD OC DF 0 Oxyfluorfen 5 µg/kg in green tea 6 0.08 Concentration [pg/µL] The TSQ 8000 Evo GC-MS/MS is a perfect fit for laboratories in need of high efficiency pesticide methods. Enhanced selectivity, speed, and sensitivity translate into real routine efficiency and productivity. Expect performance above and beyond former triple quadrupole instruments. Bifenthrin 0 BHC, Alpha 0.1 0.09 2,3,5,6-Tetrachloroaniline 0.1 European Commission GC-MS/MS Confirmatory Performance Criteria TSQ 8000 Evo GC-MS/MS Capabilities Compliance Confirmed Two specific precursor ions with two specific production ions All recommended methods developed as defined in criteria Fully optimized by AutoSRM Yes Tolerance of ion ratios within ± 15% < 10% measured at EPA 1613 CSL level (n=14) Yes Resolution of each quadrupole equal to or better than unit mass resolution All recommended methods developed Q1 and Q3 at 0.7 Da Yes The % RSD of the five (or more) Relative Response Factors (RRFs) for each unlabeled PCDD/PCDF and labelled internal standards must not exceed 20% 6 point curve EPA 1613 CSL-CS4 2% Yes 7 Expect More Expect Robustness Flexibility Unstoppable productivity Flexibility to best solve your analytical challenge The Thermo Scientific™ ISQ™ Series single quadrupole GC-MS and TSQ 8000 triple quadrupole GC-MS/MS have a strong reputation in allowing laboratories to tackle the demands of producing results on time, every time. The TSQ 8000 Evo triple quadrupole GC-MS/MS continues that legacy by enabling routine-grade robustness for ultimate performance applications in some of the most challenging matrices. The TSQ 8000 Evo GC-MS/MS addresses many laboratory mass spectrometry needs through various scan modes along with source and probe options. Excellent performance is enabled for single quadrupole-type scan modes which, in turn, expand system versatility in the modern laboratory. 100 Biphenyl (3.6% RSD) Ortho-phenylphenol (3.7% RSD) Butylated hydroxyanisole (4.2% RSD) Phorate (3.1% RSD) Tetrahydrophthalimide (4.7% RSD) 75 25 0 1 6 11 16 21 26 31 36 41 46 51 56 66 61 71 76 81 86 91 96 Injection # Robustness of 1:20 diluted orange oil spiked with pesticides and injected directly (n=100) 14 12 10 10 8 8 6 % RSD 12 Q2 (EvoCell) Q3 2 2 0 0 Application Selected ion monitoring (SIM) Transmission only Transmission only Selected m/z Target quantitation Full scan Transmission only Transmission only Scanning Unknown ID, library search Selected reaction monitoring (SRM) Selected m/z CID Selected m/z Target quantitation Product ion scan Selected m/z CID Scanning SRM method development and compound elucidation, build and search libraries Precursor ion scan Scanning CID Selected m/z Searching for unknown compounds giving characteristic fragments Constant neutral loss Scanning CID Scanning (- neutral loss offset) Searching for unknown compounds with common structures, e.g. acids SRM/Full Scan Alternating selecting m/z and transmission only Alternating CID/ Transmission only Alternating selecting m/z and scanning Target quantitation and unknown ID by library search Ion sources and probes are removable without requiring a break in the vacuum, and they enable you to perform MS and MS/MS experiments on solids in real time while effortlessly switching between electron ionization (EI) and chemical ionization (CI). Direct Insertion Probe (DIP) Slower volatilization with heated capillary tube for solid samples. The DIP can be utilized for rapid analysis of solids or trace components in solid matrices such as forensic samples, tissue, etc. Direct Exposure Probe (DEP) Rapid heating filament for liquids or solutions. The DEP is ideal for rapid molecular weight confirmation of solids dissolved or suspended in a suitable solvent. Chemical Ionization Chemical ionization is a softer form of ionization than electron ionization (EI). It offers a greater opportunity to generate more abundant high mass and molecular ions and a higher degree of selectivity or sensitivity in the source ionization process, especially with negative chemical ionization (NCI), favoring electronegative compounds, such as halogenated species. Chemical ionization is ideally used for structure elucidation also in MS/MS mode. Di c Tr hob ibr e om nil oa nis o Su l lfo tep H Pa CB rat hio Ipr n od ion Az inp ho EPN sMe Pe thyl m De ethr lta in me thr in 4 %RSD pesticides (10 ppb) before and after 1,400 vegetable matrix injections After 6 4 c Tr hob ibr e om nil oa nis o Su l lfo tep H Pa CB rat hio Ipr n od ion Az inp ho EPN sMe Pe thyl m De ethr lta in me thr in % RSD Before Di Q1 50 14 Mode Robustness Cold Pressed Orange Oil (external standard calibration) pg/µL The patented Thermo Scientific™ ExtractaBrite™ ion source is heated throughout and includes the first RF region (RF lens), commonly the first place susceptible to ion burn. This design ensures high matrix tolerance for high throughput applications. Crucially, it is fully removable, even when hot, under vacuum for necessary cleaning or swapping with a spare source. There is never a need to vent to clean your instrument or to heat or clean quadrupoles. Enjoy constant productivity. 8 More 9 brilliant Design for brilliant Industry-Leading Detector Linearity Results The Thermo Scientific DynaMax detection system standard on the TSQ 8000 Evo system offers industry-best linearity. Combined with the low detection limits attainable by SRM, this detector makes the mass spectrometer the ultimate quantitative instrument. EvoCell Collision Cell Technology High performance SRM at high velocity transition speeds. Remove the Source of your Downtime Allows full source removal without venting the MS including ion guide surface. No wire connections are necessary, and venting is never necessary to clean your instrument. Never Clean or Replace Quads Heated ion guide protects the main quadrupole sets so they never require cleaning or replacement. ExtractaBrite wireless ion source cartridge Switch Between Full Scan, SIM and MRM in Milliseconds Effortless switching is made possible with the fast scanning capabilities of the TSQ 8000 Evo GC-MS/MS. Dual Heated Zones on Source Maximize Ruggedness Dual independently-heated zones on the TSQ 8000 Evo system allow for thousands of injections of the dirtiest matrices before source cleaning is required. No Helium Required Choose between nitrogen or argon for collision gas. No expensive helium is required. Fast Scanning Allows Fast Chromatography Dynamic ion expulsion in the collision cell allows hundreds of MRM transitions per second. Combined with t-SRM for efficiently managed transition scheduling, the TSQ 8000 Evo system can analyze hundreds of compounds with multiple transitions each over short chromatographic runs. On-Axis (in-line) Optics 10 Dual Filaments for Prolonged Uptime Intelligent dual filament design keeps you running longer between maintenance intervals. No Noise is Good Noise Off-axis optics provided by the curved ion guide effectively eliminate neutral noise, resulting in less background and lower limits of detection. noise reduced to ~ 2 ions/sec 11 Expect More Simplicity AutoSRM Workflow Easy MS/MS Your Starting Point The advantages of selected reaction monitoring (SRM) and multiple reaction monitoring (MRM) analysis often come with challenges, especially with respect to adoption of new technology in the laboratory. These challenges are due to the method set-up and optimization and management of complex analytical methods. Laboratories that strive to realize the benefits of MS/MS must overcome some barriers in the tuning, set-up and optimization to reduce the time required to achieve a smooth operating routine. • AutoSRM: A purpose-built software for automated SRM method creation and optimization from full scan to the complete analytical method setup • TSQ 8000 Evo GC-MS/MS Instrument Method: Offers true timed-SRM operation, allowing for high sensitivity and ease of use for the most complex SRM methods Unknown SRM transitions • Start from the very beginning • Start with existing SIM method AutoSRM SRM Optimization The TSQ 8000 Evo GC-MS/MS was built to guarantee an easy start-up. Whether you are managing retention times, starting a completely new analysis, transferring a method from a single quadrupole system, or porting a known MRM method from another instrument, the TSQ 8000 Evo system ensures the fastest route to routine high performance results through its integrated software tools. From a Previous MS/MS Method If you have already performed previous AutoSRM steps or are simply moving from another MS/MS system, then Step 3 can take you to the final fully optimized SRM transitions for your compounds. Fully automated collision energy optimization is performed to ensure that transitions are as sensitive as they can be. These optimized SRM transitions are then exported into a finished MRM method ready for analyzing real samples in routine. 12 TSQ 8000 Evo Instrument Method • From an existing method • From SRM transition list Method Sync From an Existing SIM Method If you are moving from a single quadrupole GC-MS method using SIM analysis, or you already know which ions you want to select for your precursor ions, you can start with Step 2. The AutoSRM function performs product ion scans for each selected precursor and presents the results in a single window. Simply select (or ask AutoSRM to select) the best product ion for that compound. Step 2: Selects your product ions from product ion scans Known SRM transitions • Thermo Scientific™ TraceFinder™ Software: State of the art, multi-platform user-friendly chromatography analysis software From the Start For new compounds, choose to begin the AutoSRM function, ask for a precursor ion study (Step 1), and place a vial with the compound mix in the autosampler. The AutoSRM function reports a full scan chromatogram of the injection, and you simply identify your peaks and choose the most appropriate precursors that AutoSRM presents. In the case of coeluting compounds, AutoSRM automatically performs one injection per compound. Step 1: S elects your precursor ions from full scan Step 3: O ptimizes the collision energy for selected transitions Optimized SRM transitions • From Compound Data Store • From existing GC-MS/MS method TraceFinder Software 13 Be More Productive Fast, flexible, easy-to-use mass spectrometry software The challenge The constant pressure to increase productivity challenges laboratory staff at every level, from the technician to management. Streamlined, workflow-driven software solutions are needed to address these challenges. At the same time, the growing list of compounds that laboratories must quantify and screen, combined with increasingly complex regulatory requirements, necessitate flexible method development and powerful reporting tools. Powerful method development TraceFinder software provides powerful tools for method developers, including: TraceFinder software is the solution TraceFinder software makes routine quantitation simple, fast and productive. It offers a complete solution that can be used to develop methods, acquire and process data, and generate standard and customized reports with the full portfolio of Thermo Scientific mass spectrometers. • Automated retention time and ion ratio adjustment •C ompound databases (CDB) for rapid selected reaction monitoring (SRM) method development • User-defined flags for nearly every parameter Leading the way in regulatory POPs quantitation Thermo Scientific TargetQuan software is uniquely tailored for a workflow-orientated POPs quantitation, like PCDD/Fs, PCBs, PBDEs and others. This software package is designed specifically to serve laboratories charged with performing routine quantitation of POPs in a regulated environment. With TargetQuan 3 software, comprehensive processing of MS, MS/MS and HRMS data is possible on a single software platform, compliant with the US EPA 1613 requirements. Compound Database contains hundreds of compounds and parameters for SRM work flows, allowing rapid method development 14 Simple, full-featured data review TraceFinder software offers simple, yet exceptionally feature-rich data review capabilities. The intuitive, workflow-driven arrangement of information simplifies the technician’s role in reviewing data. The technician can quickly and easily observe the data processing status, view compound-related flags to locate compounds which need attention, and take appropriate steps to address any problems. Powerful, automated reporting The new TraceFinder software report designer offers enhanced laboratory productivity with customizable, automated reporting with numerous standard report templates. 15 More Experience innovation Example of plug-in module installation by user Tackle future challenges through GC modularity Enable Quick Customization with GC Modularity Tailor the Thermo Scientific™ TRACE™ 1300 Series GC to your needs with its proprietary user-exchangeable Instant Connect injector and detector modules. Swapping modules is easily done by the removal and replacement of three screws, accessible from the top of the GC. The entire process takes less than five minutes without requiring specialized service assistance. This enables budget-conscious laboratories to purchase a base-configured GC today, then easily expand their capabilities to accommodate new application and throughput demands. Ensure Uninterrupted Analyses and Save Budget by Conserving Helium The helium shortage continues to inflict price pressure and supply uncertainty on laboratories that require these gas supplies to perform their research and analyses. Estimated Cylinder Lifetime GC and GC-MS Operating Conditions* Conventional Operation With the Instant Connect Helium Saver Module Around the Clock Analysis 24 hours a day, 7 days a week, 365 days a year 5 months 3.5 years Daily Operations Leaving the GC idle at the end of workdays and on weekends 15 months Realizing the importance of finding a safe, cost-effective solution, the proprietary Instant Connect Helium Saver Module has been introduced to drastically reduce helium carrier gas consumption and extend helium cylinder lifetime up to 14 years per instrument, without any GC or GC-MS method modifications. Helium is continuously saved, both while the GC is in operation and while it is idle. Previously acquired retention times remain unchanged, and no method revalidation is required. 14.6 years * Conditions: Operating a TRACE 1300 Series GC with helium at 4 mL/min (sccm) using a typical helium cylinder of 48 L volume at 2250 psig. RT: 2.01 - 13.60 10.32 100 90 11.25 6.86 80 70 4.58 60 50 3.51 40 3.56 3.26 3.85 4.69 5.20 5.30 4.28 5.05 3.95 30 5.36 5.47 6.11 9.03 7.88 7.93 6.29 5.68 12.71 7.00 6.48 7.40 7.47 7.04 7.67 5.97 8.45 8.09 9.81 9.88 10.86 13.05 11.56 20 2.58 7.12 10 2.52 0 100 4.97 2.78 3.22 8.18 8.53 6.81 10.77 9.62 12.01 12.18 80 8.98 4.55 70 60 50 3.48 3.54 4.49 3.66 4.25 3.82 40 3.37 30 5.63 4.66 6.06 6.44 6.95 5.32 5.01 5.46 5.93 8.05 12.63 11.45 12.95 8.41 7.62 9.77 9.84 9.33 10.81 11.50 10.72 3.0 8.11 4.94 2.77 3.19 2.5 11.17 Backflush and Large Volume Capabilities The capabilities of the Instant Connect injector modules are further enhanced by the available concurrent backflush options. These solutions enable the user to reverse the flow inside the injector, eliminating heavy or “undesired” compounds concurrently during the analysis run, protecting the column and detector while cutting down non-productive times, thus increasing throughput. 7.08 2.57 2.15 9.19 7.00 20 10 7.42 7.35 6.57 4.15 3.24 11.19 7.84 7.89 6.25 5.16 5.26 13.19 10.28 10.25 90 0 11.52 11.22 9.23 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 Time (min) 8.48 8.5 10.39 9.58 9.0 9.5 10.0 10.5 11.94 12.10 11.0 11.5 12.0 12.5 13.0 Instant Connect-SSL concurrent backflush. The T-piece for column connections and its carrier gas control are integrated within the module Using the Instant Connect Helium Saver Module, results from US EPA Method 8270C (semi-volatiles) remain unchanged www.thermoscientific.com/tsq8000evo ©2014 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Africa-Other +27 11 570 1840 Australia +61 3 9757 4300 Austria +43 810 282 206 Belgium +32 53 73 42 41 Canada +1 800 530 8447 China +86 10 8419 3588 Denmark +45 70 23 62 60 Europe-Other +43 1 333 50 34 0 Finland +358 9 3291 0200 France +33 1 60 92 48 00 Germany +49 6103 408 1014 India +91 22 6742 9494 Italy +39 02 950 591 Japan +81 45 453 9100 Latin America +1 561 688 8700 Middle East +43 1 333 50 34 0 Netherlands +31 76 579 55 55 New Zealand +64 9 980 6700 Norway +46 8 556 468 00 Russia/CIS +43 1 333 50 34 0 South Africa +27 11 570 1840 Spain +34 914 845 965 Sweden +46 8 556 468 00 Switzerland +41 61 716 77 00 UK +44 1442 233555 USA +1 800 532 4752 BR10376-EN 1214S
© Copyright 2024 Paperzz