HPE Knowledge Article Smart Storage Administrator-How to Expand an Array and Extend the Logical Drive Article Number mmr_sf-EN_US000010855 Environment any DL/ML server how to expand the array and extend the logical drive Array expansion and logical drive extension is supported only if the HP Smart Array Controller is installed with both cache and battery. HPE Smart Array controllers supports Battery-Backed Write Cache (BBWC) or Flash-Backed Write Cache (FBWC). As a first step, one needs to confirm whether server is installed with both cache and battery. Issue any DL/ML server how to expand the array and extend the logical drive Cause any DL/ML server how to expand the array and extend the logical drive Resolution Open SSA > choose logical devices >Array “x” > manage data drives Select the drive you want to add > add drive > OK NEED TO WAIT UNTIL THE EXPAND PROCESS WILL FINISH! TO extend the logical drive – Choose logical drives > logical drives “x” > extend logical drive Check the maximum size / custom size > OK © Copyright 2016 Hewlett Packard Enterprise Development LP. The information contained herein is subject to change without notice.The only warranties for Hewlett Packard Enterprise products and services are set forth in the express warranty statements accompanying such products and services.Nothing herein should be construed as constituting an additional warranty. Hewlett Packard Enterprise shall not be liable for technical or editorial errors or omissions contained herein.