Intake/exhaust grille pitch 100 mm GVZ 100 pag. B-7 Description Intake/exhaust grille pitch 100 mm. Inclined blades with anti-rain profile. Fixing by visible frontal screws. It is commonly used for air intake/exhaust in air conditioning/ventilating systems usually in the industrial field. Dimensions B (mm) : 200 - 3000 (with increase of 100) H (mm) : 200 - 2000 (with increase of 100) Construction Galvanised steel sheet frame thickness 15/10, galvanised steel blade thickness 10/10. Finish Only GVZ105 Galvanised steel. 10 Other versions X 23 B8 600 50 GVZ 100 R : with anti-mouse mesh. GVZ 105 : with adjustment damper. Y (B-25)x (H-25) GVX 100 : stainless steel execution. BxH H+75 100 GVA 100 : anodised aluminium execution. Accessories CTZ : galvanised steel counterframe thickness 20/10. 600 Y 50 85 B+75 23 215 GVZ/GVX 100 Specifications Intake/exhaust grille pitch 100 mm. Construction in galvanised steel sheet. Fixing by visible screws. 80 X 19 600 50 B X (mm) (mm) 200 187,5 300 X H Y (mm) (mm) 1 200 187,5 1 237,5 1 300 237,5 1 400 287,5 1 400 287,5 1 500 337,5 1 500 337,5 1 600 387,5 1 600 387,5 1 700 137,5 2 700 137,5 2 800 187,5 2 800 187,5 2 900 237,5 2 900 237,5 2 1000 287,5 2 1000 287,5 2 1100 337,5 2 1100 337,5 2 1200 387,5 2 1200 387,5 2 1300 137,5 2 1300 137,5 2 1400 187,5 3 1400 187,5 3 1500 237,5 3 1500 237,5 3 1600 287,5 3 1600 287,5 3 1700 337,5 3 1700 337,5 3 1800 387,5 3 1800 387,5 3 1900 137,5 4 1900 137,5 4 2000 187,5 4 2000 187,5 4 N* N* * n° of holes per side F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italy phone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected] 6.5 X Y (B-25)x (H-25) BxH 100 H+75 600 Y 50 10 19 B+75 GVA 100 B X (mm) (mm) 2100 237,5 4 2200 287,5 4 2300 337,5 4 2400 387,5 4 2500 137,5 5 2600 187,5 5 2700 237,5 5 2800 287,5 5 2900 337,5 5 3000 387,5 5 N* 03.11.15 Intake/exhaust grille pitch100 mm GVZ pag. B-8 Selection 1 At the requested air flow qv , with allowed sound power level LWA, you can determine from diagram 1 (by excess) the effective area Ak which the grille must have. 3.8 1.8 2.4 3.0 1.3 0.9 0.4 A =0 k .25 m 2 0.6 Performances 60 LwA (dBA) 55 2 At the requested air flow qv, with the value Ak resulting at point 1, from diagram 2 you can check that the pressure drop DP is compatible with the plan’s value. 50 3 With the value Ak resulting at point 1, from diagram 3 you can determine the product BxH, therefore the nominal dimensions B and H of the grille (setting for instance B and getting H). 45 Example 1 40 2000 3000 5000 7000 20000 10000 30000 50000 70000 140 120 2.4 1.8 1.3 0.6 160 0.4 A= k 0. 25 m2 200 180 0.9 qv (m3/h) From the first diagram you get Ak < 0,9 m2 you choose Ak = 0,9 m2 3.0 90 80 40 From the third diagram you find out that a grille with Ak = 0,9 m2, has BxH equal to about 1,4 m2 : you can use for example a grille 1400 x 1000 mm or a 2000x700 mm. 30 Air flow calculation 70 60 P (Pa) You must intake 10000 m3/h air from a room where a sound power level LWA of 50 dBA is allowed. You want to select a grille of the correct dimensions. From the second diagram you have : DP = 40 Pa 100 3.8 50 20 2 10 2000 3000 5000 7000 20000 10000 30000 50000 70000 qv (m /h) 3 6 It is necessary to position the velocity probe to measure vk as showed in the picture. You must use hot wire anemometers taking care to orient the reading “window” against the flow. In each point you must measure the average velocity in an interval of time of at least 1 minute (average in time). In order to get the air flow you must calculate therefore the arithmetic mean (ṽk) of the values measured in this way and multiply it by the value of Ak resulting from the third diagram. 5 qv = ṽk x Ak 4 3 2 BxH (m2) 100 1 0.8 0.5 3 0.3 0.2 0.3 0.5 0.8 Ak (m ) 2 1 2 3 F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italy phone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected] 3.8 03.11.15
© Copyright 2026 Paperzz