EPH2/32IS/MV/MC/HE Specification Sheet Electronic Fluorescent Ballast 7/21/2014 Project: 2 Lamp High Ballast Factor High Efficiency Multi-volt High Efficiency Catalog#: Approved by: F32T8 Instant Start Parallel Lamp Operation Lamp Type F32T8* F32T8/ES/30 F32T8/ES/28 F32T8/ES/25 F25T8 F17T8 F40T8 FB32T8 FB31T8 FB28T8 No. Of Lamps Lamp Watts Line Voltage Ballast Factor Input Watts Input Current (amps) Power Factor THD Ballast Efficacy Factor 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 1 1 2 2 1 1 2 2 1 1 2 2 1 1 32 32 32 32 30 30 30 30 28 28 28 28 25 25 25 25 25 25 25 25 17 17 17 17 40 40 32 32 32 32 31 31 31 31 28 28 28 28 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 1.18 1.18 1.38 1.38 1.18 1.18 1.38 1.38 1.18 1.18 1.38 1.38 1.18 1.18 1.38 1.38 1.20 1.20 1.40 1.40 1.23 1.23 1.42 1.42 1.35 1.35 1.18 1.18 1.38 1.38 1.18 1.18 1.38 1.38 1.18 1.18 1.38 1.38 74 73 45 45 69 69 44 44 64 63 39 39 63 62 38 38 54 54 33 33 39 39 25 25 54 54 74 73 45 45 73 71 44 44 65 63 39 39 0.62 0.27 0.37 0.17 0.58 0.25 0.36 0.16 0.54 0.24 0.33 0.15 0.53 0.23 0.32 .015 0.45 0.20 0.28 0.13 0.33 0.15 0.22 0.11 0.45 0.20 0.62 0.274 0.37 0.17 0.58 0.25 0.36 0.16 0.54 0.24 0.33 0.15 0.98 0.98 0.98 0.97 0.98 0.98 0.98 0.97 0.98 0.98 0.98 0.97 0.98 0.97 0.98 0.97 0.98 0.97 0.98 0.96 0.98 0.96 0.95 0.95 0.98 0.97 0.98 0.98 0.98 0.97 0.98 0.98 0.98 0.97 0.98 0.98 0.98 0.97 <10% <10% <10% <15% <10% <15% <10% <15% <10% <15% <10% <15% <10% <15% <10% <15% <10% <15% <10% <15% <10% <15% <10% <15% <10% <15% <10% <10% <10% <15% <10% <10% <10% <15% <10% <15% <10% <15% 1.59 1.61 3.06 3.06 1.71 1.71 3.13 3.14 1.84 1.87 3.53 3.64 1.87 1.90 3.63 3.63 2.20 2.22 4.24 4.24 3.15 3.15 5.68 5.69 2.49 2.50 1.59 1.61 3.06 3.06 1.61 1.66 3.13 3.14 1.81 1.87 3.54 3.53 * Primary Lamp Design Ballast Specifications • Ballast shall have a five-year warranty • Ballast shall be UL certified • Ballast shall be sound rated Class A • Ballast shall be Class P Type 1 Outdoor • Ballast shall have a Lamp Current Crest Factor of <1.7 • Ballast shall withstand line transients as specified in ANSI C62.41-1991 • Ballast shall comply with the limits of FCC Part 18 Class A • Ballast shall have a lamp operating frequency greater than 40kHz • Ballast shall have a 0oF minimum lamp starting temperature for primary lamp • Ballast shall be Instant Start • Ballast shall be Parallel Lamp Operation • Ballast shall have minimum Power Factor of 98% for primary Lamp operation • Ballast shall operate within +/- 10% of the ballast specified line voltage at 60 Hz • Ballast shall have a maximum case hot spot temperature of 70 Celsius Wiring Diagram BLACK WHITE RED BLUE BALLAST BLUE LAMP LAMP For 1-lamp operation cap one blue lead Side Ballast View • Specifications are subject to change without notice. Howard Lighting Products | 580 Eastview Drive | Laurel, MS 39443 (toll free) 800.956.3456 | (direct) 601.422.0033 | (fax) 601.422.1652 www.HowardLightingProducts.com L: 9.5” W: 1.3” H: 1.0” M: 9.0” Bottom Ballast View H W Dimensions 0.31 M L W
© Copyright 2026 Paperzz