SP-MBS-8-10KVA-2 INSTALLATION AND USER GUIDE SP-MBS-8-10KVA-2 Installation Instructions for bypass panel This is a bypass panel manufactured for Powervar. It is intended for use as a bypass switch for the UPS protecting critical loads. The power circuitry is enclosed in a forced air cooled metal enclosure. Visible from the front of the unit is the bypass switch operating handle. Access is through the front by use of a screwdriver to remove the front cover. Disconnect all sources of supply (Utility power and UPS power) prior to working on electrical equipment including the bypass and any downstream distribution or loads. It is recommended that a licensed electrician install and troubleshoot the equipment. This unit is HEAVY, take necessary safety precautions to prevent injury. Locate the panel in a convenient location within sight of the UPS. The unit should be installed within sight of the UPS. Be sure to keep the rear vents clear of any obstructions, failure to do so will result in damage to the unit. Conduit entry can be at the upper left or upper right side of the enclosure toward the front. Rear entry can be at the lower right side. Bottom entry is available through an access plate (remove to punch and replace). Cover any internal components when punching or drilling through enclosure walls. Incoming and outgoing wires to be terminated at the terminal block located at the upper rear section of the unit. Input from utility power (208VAC, 1PH, 60Hz, L+L+G), input from the UPS output (240/208/120, 1PH, 60Hz, L+L+L+N+G), output to UPS input (208VAC, 1PH, 60Hz, L+L+G), and output to the load (240/208/120, 1PH, 60Hz, L+L+L+N+G) will be hardwired observing local NEC codes. Wiring to be rated for 60 amps. Utility input protection by others. Refer to UPS operating and installation instructions for actual connections needed for the application. Check for tightness of all the connections inside the panel. Some wires might have worked themselves loose during shipping and handling. Insure that all connections are tight before applying power to the panel. Observe proper cable sizing per NEC or local codes. Observe proper phase sequence when hooking up the panel. SP-MBS-8-10KVA-2 Installation Instructions for bypass All hardwired inputs and outputs are to be made to the terminal block in the upper section of the backpanel. There are individual terminals for all connections. Follow NEC or local code requirements for wire sizing. UPS operation: The bypass switch should be in the “Normal” position. Conditioned power is output from the UPS to the critical load. TEST operation: In the event that the UPS needs to be serviced or replaced, rotating the bypass switch to “Test” will reroute the utility power around the UPS through the bypass contacts on the switch to power the load. It is recommended to place the UPS in internal bypass prior to switch operation. Check the UPS installation manual to determine how to perform this operation. This mode also provides power to the input of the UPS for test purposes. BYPASS operation: In the event that the UPS needs to be isolated for service or to be replaced, rotating the bypass switch to “Bypass” will reroute the utility power around the UPS through the bypass contacts on the switch to power the load. The UPS will be fully isolated from this panel in this mode. A qualified technician should use proper safety guidelines when working on the UPS. Always confirm that power has actually been removed prior to working on any equipment. General Specifications: Utility Input: 208VAC, 1PH, 60Hz, hardwired UPS Input: 208VAC, 1PH, 60Hz, hardwired UPS Output: 240/208/120VAC, 1PH, 60Hz, hardwired Output to Load: 240/208/120VAC, 1PH, 60Hz, hardwired Ampacity rating: 60 amps 24.00in REAR OF ENCLOSURE: SHOWN FROM THE REAR SIDE VIEW 3.50in 5.50in 3.75in BYPASS SWITCH 15.75in TERMINAL STRIP 11.50in TERMINAL STRIP BACK OF ENCLOSURE IS OPEN FOR VENTILATION TEST B Y P A S S FAN BARRIER SHELF N80 U P S Csii TRANSFORMER 28.00in FAN MOUNTED ON REAR OF ENCLOSURE 2.00in FRONT ACCESS WITH COVER 1 19.00in 3.75in 5.88in 3.00in 6.00in 3.00in 4.00in 3.00in 12.75in TRANSFORMER 1 4.50in 10.00in BOTTOM ACCESS PANEL WITH COVER BOTTOM VIEW FROM INSIDE LOOKING DOWN NOTES: 1 PART NUMBER OPENINGS SHOWN WITH DASHED LINES, AND COVERS OVER THE OPENINGS ARE IN RED REV. SP-MBS-8-10kVA-2 REV. A: DRAWN BY: MFN Phone: (800) 369-7179 or (847) 596-7000 Fax (847) 596-7100 1450 Lakeside Drive, Waukegan, IL 60085 www.powervar.com APPROVAL : D.U. Changed desc. per customer REV. C: 8-10KVA MBS WITH ISOLATION TRANSFORMER (60 AMP) DATE: 08/05/10 08/25/10 REV. B: Reference: BPT060-4P-N1-00 DESCRIPTION DATE: DESC.: DATE: 08/05/10 REV. D: DRAWING NO: BPT060-4P-N1-00-D-0810 APPR : D.U. INCOMING POWER 208 VOLTS AC, 1 PHASE,3 WIRE, 60Hz INTERNAL CABLE: #4 AWG (85A) PANEL RATED FOR 60A BYPASS SWITCH U TEST P S TB2: UPS INPUT TB1: UTILITY INPUT 2. L1 L1 L1 L1 L2 L2 L2 L2 UPS 17 TEST 18 1L1 UPS 19 TEST 20 1L2 1 #4AWG BLK TB3: UPS OUTPUT X4 L1 L1 X4 X4 L2 L2 N N #4AWG BLK TO DISTRIBUTION OR COMPUTER LOAD TB4: CRITICAL LOAD #4AWG BLK UNINTERRUPTIBLE POWER SUPPLY 208 VOLTS 1 PHASE B Y P A S S X2 X1 X1 UPS 1X4 4 X4 X4 N 7 UPS 120V 1N 8 208V N X2 X2 3 1X2 11 UPS 12 1X1 15 UPS 16 X2 120V X2 X1 N 240V X1 X1 GROUND 1 GROUND GROUND GROUND #4AWG BLK L2 TRANSFORMER 0V L2 0V 0V L1 L1 120V 120V 208V 208V 208V 240V 240V 1 BYP. 2 TEST 5 BYP. 6 TEST 9 BYP. 10 TEST 13 BYP. 14 TEST 240V 1 GROUND F1: 8/10A USE BUSSMAN FNM 8/10 OR EQUAL AUX. SWITCH 1 #8AWG GRN 4L2 1 BYP. 2 TEST 2 3 BYP. 4 TEST 3 FAN : 120VAC #14AWG RED NOTES: 1 2 PART NUMBER SWITCH CONTACTS ARE "MAKE-BEFORE-BREAK" CONTACTS MARKED "UPS" ARE CLOSED IN THE "UPS" POSITION. CONTACTS MARKED "TEST" ARE CLOSED IN THE "TEST" POSITION. CONTACTS MARKED "BYP" ARE CLOSED IN THE "BYPASS" POSITION. SP-MBS-8-10kVA-2 Reference: BPT060-4P-N1-00 MAIN DISCONNECT AND BRANCH CIRCUIT PROTECTION PROVIDED BY OTHERS DESCRIPTION DRAWN BY: MFN Phone: (800) 369-7179 or (847) 596-7000 Fax (847) 596-7100 1450 Lakeside Drive, Waukegan, IL 60085 www.powervar.com REV. REV. A: 08/05/10 APPROVAL : D.U. DATE: 08/25/10 Changed desc. per customer REV. B: REV. C: 8-10KVA MBS WITH ISOLATION TRANSFORMER (60 AMP) DATE: DATE: DESC.: 08/05/10 REV. D: DRAWING NO: BPT060-4P-N1-00-S-0810 APPR : D.U. SP-MBS-8-10KVA-2 RATING INFORMATION: VOLTAGE: 240/208/120VAC, 60 HZ PHASE: SINGLE PHASE FULL LOAD CURRENT: 60 AMPS INTERRUPT RATING: 5KAIC SYM @ 600VAC TYPE 1 ENCLOSURE CONTACT INFORMATION: Powervar 1450 Lakeside Dr. Waukegan, Il. 60085 (800) 369-7179 or (847) 596-7000 Fax (847) 596-7100
© Copyright 2026 Paperzz