Catalog Number FEATURES & SPECIFICATIONS Notes INTENDED USE — Specification premium, high performance, static T5 luminaires provide general illumination for recessed applications; ideal for restricted plenum spaces. Certain airborne contaminants can diminish integrity of acrylic. Click here for Acrylic Environmental Compatibility table for suitable uses. Type ATTRIBUTES — Designed specifically for use with high-efficiency T5 lamps, electronic ballasts and rotary sockets. Specification Premium T5 Troffer CONSTRUCTION — Smooth hemmed sides and smooth, inward formed end flanges for easy handling. Lighter weight fixture allows safe, easy installation. SP 2'X2' Standard steel door frame has superior structural integrity with premium extruded appearance and precision flush mitered corners. Steel door allows easy lens replacement without frame disassembly (for lenses up to .156" thick). Powder-painted, steel latches provide easy, secure door closure. Superior mechanical light seal requires no foam gasketing. Integral T-bar clips secure fixture to T-bar system. Housing formed from cold‑rolled steel. Acrylic shielding material 100% UV stabilized. No asbestos is used in this product. US PATENTS: 6,210,025; 6,231,213; 6,213,625; 2,288,471. T5 or T5HO Lamps 2, 3 or 4 lamps Finish: Five‑stage iron‑phosphate pretreatment ensures superior paint adhesion and rust resistance. Painted parts finished with highly reflective matte white enamel. OPTICAL — A12 lens features reverse apex technology for superior lamp obscuration and improved visual comfort. ELECTRICAL SYSTEM — Standard ballast is electronic programmed rapid start, thermally protected, resetting, Class P, HPF, non‑PCB, UL Listed, CSA certified ballast, universal voltage and sound rated A. Specifications Luminaire is suitable for damp locations. AWM, TFN or THHN wire used throughout, rated for required temperatures. Length: 24 (610) LISTING — Standard: UL. Optional: Canada — CSA or cUL; Mexico — NOM. Depth: 4-1/2 (114) WARRANTY — 1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx Weight: 16 lbs (7 kg) Width: 24 (610) All dimensions are inches (millimeters). Actual performance may differ as a result of end-user environment and application. Note: Specifications subject to change without notice. ORDERING INFORMATION Example: 2SP G 2 14T5 A12 MVOLT GEB115 For shortest lead times, configure products using bolded options. 2SP Series 2SP Number of lamps Lamp type Trim Type G F 2 3 4 Grid Overlapping flanged Ballast GEB115 GEB115S GEB10PS Door frame 14T5 14W T5 (22") 24T5HO 24W T5HO (22")1 (blank) FN FM FW RN RM RW Diffuser type Flush steel, white Flush aluminum, natural Flush aluminum,matte black Flush aluminum, white Regressed aluminum, natural Regressed aluminum, matte black Regressed aluminum, white A12 RA125 A12125 A19 #12 pattern acrylic, reverse apex #12 pattern acrylic, reverse apex 0.125" thick #12 pattern acrylic 0.125" thick #19 pattern acrylic 0.156" thick Voltage MVOLT2 120 277 3473 others available Options 1.15 ballast factor 1.15 ballast factor, step dimming4 1.00 ballast factor5 4 EL6 GLR GMF LP835 LP841 Emergency battery pack Internal fast-blow fuse6 Internal slow-blow fuse6 3500K 4100K PWS1836 PWS1846 JP CSA NOM 6' prewire, 3/8" dia., 18-gauge, 3 wires 6' prewire, 3/8" dia., 18-gauge, 4 wires7 Palletized and stretch-wrapped without individual cartons CSA Certified NOM Certified NOTES: 1. For T5HO applications, use GEB10PS. 2. MVOLT (120-277 volts), 50-60HZ. 3. For 347V, use GEB95S or GEB10PS. 4. Available with two- or four-lamp configurations only. 5. Not available with 4 lamp option. 6. Must specify voltage: 120V or 277V. 7. Use with GEB95S or GEB115S. FLUORESCENT SP-2x2-T5 SP 2' x 2' Static T5 Troffer MOUNTING DATA Continuous row mounting of flanged units requires CRE and CRM trim options (see Options). DIMENSIONS All dimensions are inches (millimeters). NOTE: 1 Recommended rough-in dimensions for F trim fixtures 24" x 24" (Tolerance is +1/4", -0”). Swing-gate range 1-5/8" to 3-3/4". Swing-gate span 23-3/8" to 26-11/16". PHOTOMETRICS Calculated using the zonal cavity method in accordance with IESNA LM41 procedure. Floor reflectances are 20%. Lamp configurations shown are typical. Full photometric data on these and other configurations available upon request. RCR pf pc pw 0 1 2 3 4 5 6 7 8 9 10 Coefficients of Utilization 20% 80% 70% 50% 30% 10% 50% 30% 10% 100 100 100 102 102 102 88 85 83 90 87 84 78 73 69 80 75 70 70 64 59 71 65 59 62 56 51 64 57 51 56 49 44 57 50 45 51 44 39 52 45 39 47 40 35 47 40 35 43 36 31 43 36 31 39 33 28 40 33 28 36 30 26 37 30 26 TEST NO: LTL17002 LUMINAIRE CATALOG NO.: 2SP G2 24T5HO A12 GEB10PS LUMENS PER LAMP: 2000 50% 50% 30% 10% 95 95 95 85 82 80 75 71 68 67 62 58 60 55 50 54 49 44 50 43 39 45 39 35 42 35 31 38 32 28 35 30 26 Zonal Lumen Summary Zone Lumens % Lamp % Fixture 32.5 27.9 0° - 30° 668.6 52.8 0° - 40° 1087.4 45.3 85.7 0° - 60° 1763.8 73.5 100.0 0° - 90° 2058.6 85.8 0.0 0.0 90° - 180° 0.0 100.0 0° - 180° 2058.6 85.8 pf pc pw 0 1 2 3 4 5 6 7 8 9 10 RCR TEST NO: LTL16992 LUMINAIRE CATALOG NO.: 2SP G2 14T5 A12 GEB10PS LUMENS PER LAMP: 1200 Coefficients of Utilization 20% 80% 70% 50% 30% 10% 50% 30% 10% 101 101 101 104 104 104 90 87 84 92 88 85 79 74 70 81 76 71 71 65 60 72 65 60 63 57 51 64 57 52 57 50 45 58 51 45 52 45 40 53 45 40 47 40 35 48 41 35 43 36 32 44 37 32 40 33 29 40 33 29 37 30 26 37 31 26 Zonal Lumen Summary Zone Lumens % Lamp % Fixture 32.3 0° - 30° 1125.7 28.1 52.7 0° - 40° 1834.2 45.9 85.6 0° - 60° 2979.8 74.5 100.0 0° - 90° 3479.8 87.0 0.0 0.0 90° - 180° 0.0 100.0 0° - 180° 3479.8 87.0 FLUORESCENT: One Lithonia Way Conyers, GA 30012 50% 50% 30% 10% 97 97 97 86 83 81 76 72 69 68 63 59 61 55 51 55 49 44 50 44 39 46 40 35 42 36 32 39 33 29 36 30 26 Phone: 800-858-7763 Fax: 770-929-8789 www.lithonia.com SP-2x2-T5 ©2008-2016 Acuity Brands Lighting, Inc. All rights reserved. Rev. 04/05/16
© Copyright 2026 Paperzz