Kuhlman Electric Corporation 25000 Volt Instrument Transformers 25000 Volt March 2008 Table of Contents Description Model Page Wound, Dry-Type VT – Y Burden (High Accuracy available) PTT-150-9710(H) 3-4 Wound, Oil-Filled VT – ZZ Burden, Distribution Class (High Accuracy available) SPOF-150 (DB) 5-6 Wound, Oil-Filled VT – ZZ Burden, Substation Class (High Accuracy available) POF-150 (DB) 7-8 Wound, Dry-Type CT – Standard Range (High Accuracy available) BB-25-973(H) 9-10 Wound, Dry-Type CT – Extended Range BB-25-974 11-12 4 ½” Window CT – Single, Dual & Multi Ratio (High Accuracy available) LG(X)-25-585 13-14 4 ½” Window CT – Single, Dual & Multi Ratio LG-25-879 15-16 8 ¾” Window CT – Single, Dual & Multi Ratio (High Accuracy available) LG(X)-25-6513 17-18 Wound, Oil-filled CT (High Accuracy available) COF(CXM)-150 19-20 Wound, Dry-Type, Single Phase Metering Unit KM-25-973 21-22 Wound, Oil-Filled, Single Phase Metering Unit (High Accuracy available) JS(JXM)-150 23-24 Wound, Oil-Filled, Three Phase Metering Unit (High Accuracy available) MVCT(MXM)-150 25-26 Wound, Dry-Type, Three Phase CT/VT Metering Rack (High Accuracy available) ME-025 27-28 Wound, Dry-Type, Three Phase Metering Unit Metering Rack MK-25 29-30 Three Phase Dead-Front CT/VT Metering Cubicle (High Accuracy available) MP-025 31-32 Indoor, Wound, Dry-Type, Single Phase Dead-Front Metering Unit KCB-24 33-34 Three Phase Low Profile, Dead-Front Metering Unit Metering Cubicle MI-25 35-36 2 Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage PTT–150–9710(H) Voltage Transformer Outdoor 25kV, 150kV BIL, Single & Dual Ratios (w/ Tertiary) Molded Epoxy, Wound Type, Metering/Relaying 25000 Volt March 2008 application The PTT-150-9710(H) outdoor voltage transformer is rated for use on 25,000 volt systems with 150kV BIL. Primary voltage ratios are available from 100:1 to 200:1 for use on 25,000 volt systems, at 60 Hertz (Hz). This dry-type, solid-cast voltage transformer will operate with high accuracy for metering or relay applications. mechanical description The core and coil assembly is wound and encapsulated in a high dielectric strength epoxy resin to provide high withstand capabilities. The external line to ground insulation consists of a cycloaliphatic epoxy resin that provides excellent arc track properties in addition to ultraviolet resistance and strong physical strength. The primary terminals are M12 stud with a compression type lug for #8 - #2 AWG conductors. The clamp-type post secondary terminals have ¼”-20 slotted screws and associated hardware located inside a removable terminal box with two (2) 1” NPT conduit hubs and a 1” knockout on the bottom of the box. accuracy performance The PTT-150-9710 will operate with 0.3 Class accuracy for metering and relay applications with burdens of 0, W, X, M, and Y. The PTT-150-9710H will operate with 0.15 Class high accuracy for metering applications with burdens of 0, W, and X. The transformer is accurate from 90% to 110% of rated primary voltage. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 120% of the nominal system voltage. mounting The PTT is designed for mounting on poles or substation structures in an upright, underhung or cantilever position. The mounting holes in the heavy galvanized steel plate are punched to industry standard dimensions for interchangeability in the field. options Units are available with dual system voltage ratings and/or in single or double bushing models. The PTT-150-9710H high accuracy voltage transformer is only available in the double bushing model. Contact factory for other needs. ORDERING INFO FOR PTT-150-9710(G) Accuracy/ Burden Catalog Number 2 Bushing Only Accuracy/ Burden F914100S0 F914100Y0 F914110S0 F914120S0 F914120Y0 0.3 0,W,X,M,Y 0.3 0,W,X,M,Y 0.3 0,W,X,M,Y 0.3 0,W,X,M,Y 0.3 0,W,X,M,Y F914100E0 -F914110E0 F914120E0 -- 0.15 0,W,X -0.15 0,W,X 0.15 0,W,X -- F914G120P0 F914120P0 0.3 0,W,X / Y -- -- 120 & 120 F914G120W0 F914120W0 0.3 0,W,X / Y -- -- 120/72 120 120 & 120 120 120 & 120 F914G120D0 ----- F914120D0 F914150S0 F914150Y0 F914200S0 F914200Y0 0.3 0,W,X,M,Y 0.3 0,W,X,M,Y 0.3 0,W,X,M,Y 0.3 0,W,X,M,Y 0.3 0,W,X,M,Y -F914150E0 -F914200E0 -- -0.15 0,W,X -0.15 0,W,X -- Ratio Primary Secondary 100:1 100:1:1 110:1 120:1 120:1:1 12000 12000 13200 14400 14400 7200 or 14400 7200 or 14400 14400 18000 18000 24000 24000 120 120 & 120 120 120 120 & 120 F914G100S0 -F914G110S0 F914G120S0 -- 120 60/120:1 60/120:1:1 120/200:1 150:1 150:1:1 200:1 200:1:1 HIGH ACCURACY PTT-150-9710H Catalog Number* 1 Bushing 2 Bushing - Thermal Burden Rating (Typical): 1500VA (Single Ratio), 1000VA (Dual Ratio), 750VA (w/ Tertiary). - Overvoltage Rating: 1.1x cont. * All units are RUS accepted and IC Approval AE-1284 is noted by bold catalog number. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 3 25000 Volt March 2008 4 PTT–150–9710(H) Voltage Transformer NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage SPOF–150 (DB) Voltage Transformer 25000 Volt Outdoor 25kV, 150kV BIL, Single & Dual Ratios (w/ Tertiary) Oil-Filled, Wound Type, Metering/Relaying March 2008 application The SPOF-150 (DB) outdoor voltage transformer is rated for use on 25,000 volt systems with 150kV BIL. Primary voltage ratios are available from 100:1 to 200:1 for use on 25,000 volt systems, at 60 Hertz (Hz). This oil-filled voltage transformer will operate with high accuracy for metering or relay applications. mechanical description The tank is a standard distribution transformer tank made of heavy gauge sheet steel with a seam welded bottom plate and a dome shaped cover. The tank is washed and coated with anticorrosive iron phosphate and then finished with a Munsel 70 Gray bakedon electrostatic polyester powder. The primary bushing(s) are high strength porcelain with tin plated bronze, eye bolt terminal(s) that accept #8 - #2 AWG conductors and are locked with silicon bronze locking hardware. The secondary terminals consist of a feed thru block with ¼”-20 copper studs and associated hardware located inside a removable terminal box with three (3) 1 ½” NPT conduit hubs. The ground terminal is a ½”-13 pad. The unit is fitted with a pressure relief valve. accuracy performance The SPOF-150 (DB) will operate with 0.3 Class accuracy for metering applications with burdens of 0, W, X, M, Y, Z and ZZ. Upon request, 0.15 metering accuracy is available for burdens of 0, W, X, M, Y and Z, as well as 0.3 ZZ. The transformer is accurate from 90% to 110% of rated primary voltage. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Additional tests include dissipation and partial discharge tests. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 135% of the nominal system voltage. mounting The SPOF is designed for mounting on poles or substation structures in an upright position with ANSI type “A” hanger brackets or optional mounting feet. NOTE: Must be installed per NESC electrical clearances. options The SPOF is available in single or double bushing models, with NEMA 4-hole Primary Terminal(s), Mounting Feet, a 5kV H0 Bushing, Stainless Steel Tank, Oil Level Gauge, Oil Drain Valve, and/or -50°C oil. Contact factory for other needs. ORDERING INFO FOR SPOF-150 (DB) Ratio Primary Secondary 100:1:1 110:1:1 120/200:1:1 150:1:1 200/346.4:1:1 12000 13200 14400 18000 24000 120 & 120 120 & 120 120/70 & 120/70 120 & 120 120/69.3 & 120/69.3 HIGH ACCURACY SPOF-150 (DB) Catalog Number 1 Bushing 2 Bushing Accuracy/ Burden Catalog Number Accuracy/ Burden F830100YA F830110YA F830200TA --- F840100YA F840110YA F840200TA F840150YA F840346TA 0.3 0,W,X,M,Y,Z,ZZ 0.3 0,W,X,M,Y,Z,ZZ 0.3 0,W,X,M,Y,Z,ZZ 0.3 0,W,X,M,Y,Z,ZZ 0.3 0,W,X,M,Y,Z,ZZ Add “AAEW” to the end of the standard catalog number 0.15 0 to Z, 0.3 ZZ 0.15 0 to Z, 0.3 ZZ 0.15 0 to Z, 0.3 ZZ 0.15 0 to Z, 0.3 ZZ 0.15 0 to Z, 0.3 ZZ - Thermal Burden Rating (Typical): 5000VA. - Overvoltage Rating: 1.1x cont., 1.9x 8 hours (single bushing designs). - IC Approval AE-0681 Rev. 1 noted by bold catalog number. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 5 25000 Volt March 2008 6 SPOF–150 (DB) Voltage Transformer NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage POF–150 (DB) Voltage Transformer 25000 Volt Outdoor 25kV, 150kV BIL, Single & Dual Ratios (w/ Tertiary) Oil-Filled, Wound Type, Metering/Relaying March 2008 application The POF-150 (DB) outdoor voltage transformer is rated for use on 25,000 volt systems with 150kV BIL. Primary voltage ratios are available from 100:1 to 200:1 for use on 25,000 volt systems, at 60 Hertz (Hz). This oil-filled instrument voltage transformer will operate with high accuracy for metering or relay applications. mechanical description The tank and expansion chambers are steel plate, pressure and vacuum tight and hermetically sealed at the factory to prevent breathing and oil contamination. Expansion chambers allow for the expansion/contraction of oil for temperature and load fluctuations. Tank components are washed and coated with anticorrosive iron phosphate and then finished with ANSI 70 Gray baked-on electrostatic polyester powder. The primary bushing(s) are ANSI 70 Gray, high strength porcelain with a high degree of stability for transportation and seismic withstand. The primary terminal(s) are stainless steel NEMA 4-hole pad(s). The secondary terminals are ¼”-20 copper studs with associated hardware located inside a removable terminal box with three (3) 1 ½” NPT conduit hubs. The ground terminal is a stainless steel NEMA 2-hole pad. The unit is fitted with a 5kV H0 Bushing (for single bushing designs), pressure relief valve, oil level indicator, ¾” oil fill plug, and ½” drain valve. accuracy performance The POF-150 (DB) will operate with 0.3 Class accuracy for metering applications with burdens of 0, W, X, M, Y, Z and ZZ. Upon request, 0.15 Class metering accuracy is available with burdens of 0, W, X, M, Y and Z, as well as 0.3 ZZ. The transformer is accurate from 90% to 110% of rated primary voltage. mounting The POF is designed for mounting on substation structures with mounting feet in an upright position. Single bushing units can be mounted on poles with ANSI type “A” hanger brackets. NOTE: Must be installed per NESC electrical clearances. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Additional tests include dissipation and partial discharge tests. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 135% of the nominal system voltage. options The POF is available in single or double bushing models, with Extra Creep Bushing(s), Polymer Bushing(s), Stainless Steel Tank, and/or -50°C oil. Contact factory for other needs. ORDERING INFO FOR POF-150 (DB) Ratio Primary Secondary 100:1:1 110:1:1 120/200:1:1 120/200:1:1:1 150:1:1 200/346.4:1:1 12000 13200 14400 14400 18000 24000 120 & 120 120 & 120 120/70 & 120/70 (3) 120/70 120 & 120 120/69.3 & 120/69.3 HIGH ACCURACY POF-150 (DB) Catalog Number 1 Bushing 2 Bushing Accuracy/ Burden Catalog Number Accuracy/ Burden F710100YA F710110YA F710200TA TBD --- F820100YA F820110YA F820200TA TBD F820150YA F820346TA 0.3 0,W,X,M,Y,Z,ZZ 0.3 0,W,X,M,Y,Z,ZZ 0.3 0,W,X,M,Y,Z,ZZ 0.3 0,W,X,M,Y,Z,ZZ 0.3 0,W,X,M,Y,Z,ZZ 0.3 0,W,X,M,Y,Z,ZZ Add “AAEW” to the end of the standard catalog number 0.15 0 to Z, 0.3 ZZ 0.15 0 to Z, 0.3 ZZ 0.15 0 to Z, 0.3 ZZ 0.15 0 to Z, 0.3 ZZ 0.15 0 to Z, 0.3 ZZ 0.15 0 to Z, 0.3 ZZ - Thermal Burden Rating (Typical): 5000VA. Dual primary units (4000VA L-G, 7000VA L-L). - Overvoltage Rating: 1.1x cont., 1.9x 8 hours (single bushing designs). Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 7 25000 Volt March 2008 8 POF–150 (DB) Voltage Transformer NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage BB–25–973(H) Current Transformer 25000 Volt Outdoor 25kV, 150kV BIL, Single & Dual Ratios Molded Epoxy, Wound Type, Metering/Relaying March 2008 application The BB-25-973(H) outdoor current transformer is rated for use on 25,000 volt systems with 150kV BIL. Primary current ratios are available from 5:5 to 1200:5 at 60 Hertz (Hz) with a Rating Factor of up to 1.5 (1200A max). This dry-type, solid-cast current transformer will operate with high accuracy for metering or relay applications. mechanical description The core and coil assembly is wound and encapsulated in a high dielectric strength epoxy resin to provide high withstand capabilities. The external line to ground insulation consists of a cycloaliphatic epoxy resin that provides excellent arc track properties in addition to ultraviolet resistance and strong physical strength. A high voltage stress ring around the top of the unit is supplied to control RIV and partial discharge. The primary terminals are flat, tin-plated copper with standard NEMA 2-hole pattern suitable for various size conductors. The clamp-type post secondary terminals have ¼”-20 slotted screws and associated hardware located inside a removable terminal box with two (2) 1” NPT conduit hubs and a 1” knockout on the bottom of the box. accuracy performance The BB-25-973 will operate with 0.3 Class accuracy for metering with burdens of B0.1 to B1.8 and T200 for relay applications. The transformer is accurate through its Rating Factor, and can be used continuously to this level. The BB-25-973H will operate with 0.15 Class high accuracy for metering applications with burdens of B0.1 to B0.9. The transformer maintains 0.15 accuracy from 5% (0.3 accuracy from 2%) of Inom through its Rating Factor, and can be used continuously to this level. mounting The BB is designed for mounting on poles or substation structures in an upright, underhung or cantilever position. The mounting holes in the heavy galvanized steel plate are punched to industry standard dimensions for interchangeability in the field. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 120% of the nominal system voltage. options A primary spark gap is available for capacitor bank or other applications where high transients will be present. 90° angle primary bus adapters can be supplied to place the two terminal surfaces parallel to one another. Contact factory for other needs. ORDERING INFO FOR BB-25-973 Ratio Catalog Number* 5:5 10:5 F9060005S0 F9060010S0 Catalog Number* Accuracy/ Burden Rating Factor 1.5 1.5 F9060005E0 F9060010E0 0.15 B0.9 0.15 B0.9 1.5 1.5 0.15 B0.9 0.15 B0.9 0.15 B0.9 … F9060050E0 F9060075E0 F9060100E0 … 1.5 1.5 1.5 … T200 T200 T200 Rating Factor … 0.3 B1.8 0.3 B1.8 0.3 B1.8 T200 T200 … F9060050S0 F9060075S0 F9060100S0 0.3 B1.8 0.3 B1.8 … … … 50:5 75:5 100:5 HIGH ACCURACY BB-25-973H Accuracy/Burden Metering Relay 1.5 1.5 1.5 … … … … … … … … 600:5 800:5 1000:5 1200:5 F9060600S0 F9060800S0 F9061000S0 F9061200S0 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 T200 T200 T200 T200 1.5 1.2 1.0 1.0 F9060600E0 F9060800E0 F9061000E0 F9061200E0 0.15 B0.9 0.15 B0.9 0.15 B0.9 0.15 B0.9 1.5 1.2 1.0 1.0 5/10:5 10/20:5 F9060005D0 F9060010D0 0.3 B0.9/B1.8 0.3 B0.9/B1.8 T100/T200 T100/T200 2.0/1.5 2.0/1.5 F9060005F0 F9060010F0 0.15 B0.5/B0.9 0.15 B0.5/B0.9 2.0/1.5 2.0/1.5 0.15 B0.5/B0.9 0.15 B0.5/B0.9 0.15 B0.5/B0.9 0.15 B0.5/B0.9 … F9060300F0 F9060400F0 F9060500F0 F9060600F0 … 2.0/1.5 1.2/1.2 1.0/1.0 1.0/1.0 … T100/T200 T100/T200 T100/T200 T100/T200 … 0.3 B0.9/B1.8 0.3 B0.9/B1.8 0.3 B0.9/B1.8 0.3 B0.9/B1.8 … F9060300D0 F9060400D0 F9060500D0 F9060600D0 … … … 300/600:5 400/800:5 500/1000:5 600/1200:5 2.0/1.5 1.2/1.2 1.0/1.0 1.0/1.0 - 1 Second Thermal/Mechanical Rating: 100x/200x full winding Inom (75x/150x for above 600:5 & 300/600:5). * All units are RUS accepted and IC Approval AE-0785 is noted by bold catalog number. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 9 25000 Volt March 2008 10 BB–25–973(H) Current Transformer NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage BB–25–974 Current Transformer 25000 Volt Outdoor 25kV, 150kV BIL, Single Ratios Molded Epoxy, Wound Type, Metering March 2008 application The BB-25-974 outdoor extended range current transformer is rated for use on 25,000 volt systems with 150kV BIL. Primary current ratios are available from 5:5 to 1200:5 at 60 Hertz (Hz) with a Rating Factor of up to 3.0 (1800A max). This dry-type, solid-cast current transformer will operate with high accuracy for metering applications. mechanical description The core and coil assembly is wound and encapsulated in a high dielectric strength epoxy resin to provide high withstand capabilities. The external line to ground insulation consists of a cycloaliphatic epoxy resin that provides excellent arc track properties in addition to ultraviolet resistance and strong physical strength. A high voltage stress ring around the top of the unit is supplied to control RIV and partial discharge. The primary terminals are flat, tin-plated copper with standard NEMA 2-hole pattern suitable for various size conductors. The clamp-type post secondary terminals have ¼”-20 slotted screws and associated hardware located inside a removable terminal box with two (2) 1” NPT conduit hubs and a 1” knockout on the bottom of the box. accuracy performance The BB-25-974 will operate with 0.3 Class accuracy for metering with burdens of B0.1 to B0.9 and T60 for relay applications. The transformer is accurate through its Rating Factor, and can be used continuously to this level. mounting The BB is designed for mounting on poles or substation structures in an upright, underhung or cantilever position. The mounting holes in the heavy galvanized steel plate are punched to industry standard dimensions for interchangeability in the field. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 120% of the nominal system voltage. options A primary spark gap is available for capacitor bank or other applications where high transients will be present. 90° angle primary bus adapters can be supplied to place the two terminal surfaces parallel to one another. Contact factory for other needs. ORDERING INFO FOR BB-25-974 Ratio Catalog Number* 5:5 10:5 15:5 20:5 25:5 30:5 40:5 50:5 75:5 100:5 150:5 200:5 300:5 400:5 600:5 800:5 1000:5 1200:5 F9070005S0 F9070010S0 F9070015S0 F9070020S0 F9070025S0 F9070030S0 F9070040S0 F9070050S0 F9070075S0 F9070100S0 F9070150S0 F9070200S0 F9070300S0 F9070400S0 F9070600S0 F9070800S0 F9071000S0 F9071200S0 HIGH ACCURACY N/A Accuracy/Burden Metering Relay 0.3 B0.9 0.3 B0.9 0.3 B0.9 0.3 B0.9 0.3 B0.9 0.3 B0.9 0.3 B0.9 0.3 B0.9 0.3 B0.9 0.3 B0.9 0.3 B0.9 0.3 B0.9 0.3 B0.9 0.3 B0.9 0.3 B0.9 0.3 B0.9 0.3 B0.9 0.3 B0.9 T60 T60 T60 T60 T60 T60 T60 T60 T60 T60 T60 T60 T60 T60 T60 T60 T60 T60 Rating Factor Catalog Number Accuracy/ Burden Rating Factor 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 2.0 1.5 1.5 ------------------- ------------------- ------------------- - 1 Second Thermal/Mechanical Rating: 150x/300x Inom (100x/225x for 800:5, 80x/180x for 1000:5 and 80x/150x for 1200:5). * All units are RUS accepted and IC Approval AE-0785 is noted by bold catalog number. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 11 25000 Volt March 2008 12 BB–25–974 Current Transformer NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage LG(X)–25–585 Current Transformer 25000 Volt Outdoor 25kV, 150kV BIL, Single, Dual & Multi Ratios Molded Resin, Window Type, Metering/Relaying March 2008 mounting The LG is designed for mounting in the upright or underhung position with the tube horizontal, or in the cantilever position with the tube vertical. CAUTION: Do not mount in the mechanical description The core and coil assembly is wound and encapsulated in a cantilever position with molded cast resin with a 4 ½” window porcelain primary bushing the tube horizontal, the to provide high withstand capabilities. The high strength porcelain base plate can collapse. has a semi conductive interior with a pigtail lead to be connected Mounting holes are to the primary conductor to equalize the voltage and prevent radio punched in the aluminum interference and corona. An optional primary bus bar with NEMA base plate. 4-hole pads can also be provided. The secondary terminals are ¼”-20 copper studs with associated hardware located inside a testing The unit is individually tested per the IEEE C57.13 standard, removable terminal box with two (2) 1” NPT conduit hubs. including applied and induced voltage, accuracy and polarity. Partial discharge testing is performed to guarantee the unit is free accuracy performance The LG-25-585 will operate with 0.3 Class accuracy for metering of partial discharge through 120% of the nominal system voltage. with burdens of B0.1 to B1.8 and up to C800 for some relay The unit is tested above operating voltage for traces of corona. A applications. The transformer is accurate through its Rating “corona free” label is bonded to the completed transformer as a Factor, and can be used continuously to this level. The LGX- guarantee of trouble-free service. 25-585 will operate with 0.15 Class high accuracy for metering applications with burdens of B0.1 to B1.8. The transformer options maintains 0.3 accuracy from 1% of Inom through its Rating Factor, The LG is available with a primary bus bar kit or conductive bird and can be used continuously to this level (for 0.15 accuracy guards to prevent foreign objects from entering the porcelain window. Contact factory for other needs. range, see ratings specific to each ratio). application The LG(X)-25-585 outdoor, window-type current transformer is rated for use on 25,000 volt systems with 150kV BIL. Primary current ratios are available from 200:5 to 5000:5 at 60 Hertz (Hz) with a Rating Factor of up to 4.0. This dry-type, solid-cast current transformer will operate with high accuracy for metering or relay applications. ORDERING INFO FOR LG-25-585 HIGH ACCURACY LGX-25-585 Accuracy/Burden Metering Relay Ratio Catalog Number* Rating Factor Catalog Number 0.15/0.3 @ Burden 0.15/0.3 Acc Range Rating Factor 200:5 300:5 400:5 500:5 600:5 800:5 1000:5 1200:5 1500:5 2000:5 2500:5 3000:5 4000:5 5000:5 F030200S1 F030300S1 F030400S1 F030500S1 F030600S1 F030800S1 F031000S1 F031200S1 F031500S1 F032000S1 F032500S1 F033000S1 F034000S1 F035000S1 0.3 B0.2 0.3 B0.5 0.3 B0.9 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 C60 C100 C120 C150 C200 C300 C350 C400 C500 C600 C800 C800 C800 C800 3.0 3.0 3.0 3.0 3.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 1.5 1.1 --F030400X1 F030500X1 F030600X1 F030800X1 F031000X1 F031200X1 F031500X1 F032000X1 ----- --B0.5/B0.9 B0.5/B1.8 B0.9/B1.8 B0.9/B1.8 B1.8 B1.8 B1.8 B1.8 ----- --400/4 to 1200A 500/5 to 2000A 600/6 to 2400A 800/8 to 3200A 10 to 4000A 12 to 4800A 15 to 4500A 20 to 4000A ----- --3.0 4.0 4.0 4.0 4.0 4.0 3.0 2.0 ----- 200/400:5 300/600:5 400/800:5 600/1200:5 1000/2000:5 1500/3000:5 F030200D1 F030300D1 F030400D1 F030600D1 F031000D1 F031500D1 0.3 B0.5/B0.9 0.3 B0.5/B1.8 0.3 B0.9/B1.8 0.3 B1.8/B1.8 0.3 B1.8/B1.8 0.3 B1.8/B1.8 C60/C120 C100/C200 C150/C300 C200/C400 C300/C600 C400/C800 3.0/3.0 3.0/3.0 2.0/2.0 2.0/2.0 2.0/2.0 2.0/2.0 ------- ------- ------- ------- - Available in multi-ratio designs (full tap ratings same as single ratio above). - 1 Second Thermal/Mechanical Rating: 80x full winding Inom / Unlimited mechanical. - Available with a primary bar kit (maximum 5500A). Change last digit of catalog from 1 to 3. * IC Approval AE-0703 is noted by bold catalog number. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 13 25000 Volt March 2008 14 LG(X)–25–585 Current Transformer NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage LG–25–879 Current Transformer 25000 Volt Outdoor 25kV, 150kV BIL, Single, Dual & Multi Ratios Molded Resin, Window Type, Metering/Relaying application The LG-25-879 outdoor, window-type current transformer is rated for use on 25,000 volt systems with 150kV BIL. Primary current ratios are available from 200:5 to 10,000:5 for 60 Hertz (Hz) with a Rating Factor of up to 2.0. This dry-type, solid-cast current transformer will operate with high accuracy for metering or relay applications. mechanical description The core and coil assembly is wound and encapsulated in a molded cast resin with a 4 ½” window porcelain primary bushing to provide high withstand capabilities. The high strength porcelain has a semi conductive interior with a pigtail lead to be connected to the primary conductor to equalize the voltage and prevent radio interference and corona. An optional primary bus bar with NEMA 4-hole pads can also be provided. The secondary terminals are ¼”-20 copper studs with associated hardware located inside a removable terminal box with two (2) 1” NPT conduit hubs. accuracy performance The LG-25-879 will operate with 0.3 Class accuracy for metering with burdens of B0.1 to B1.8 and up to C800 for some relay applications. The transformer is accurate through its Rating Factor, and can be used continuously to this level. mounting The LG is designed for mounting in the upright or underhung position with the tube horizontal, or in the cantilever position March 2008 with the tube vertical. CAUTION: Do not mount in the cantilever position with the tube horizontal, the base plate can collapse. Mounting holes are punched in the aluminum base plate. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 120% of the nominal system voltage. The unit is tested above operating voltage for traces of corona. A “corona free” label is bonded to the completed transformer as a guarantee of trouble-free service. options The LG is available with a primary bus bar kit or conductive bird guards to prevent foreign objects from entering the porcelain window. The unit can be offered in single, dual or multiple core designs. Contact factory for other needs. ORDERING INFO FOR LG-25-879 HIGH ACCURACY N/A Accuracy/Burden Metering Relay Ratio Catalog Number Rating Factor Catalog Number 0.15 Accuracy Range Rating Factor 200:5 300:5 400:5 600:5 800:5 1000:5 1200:5 1500:5 2000:5 2500:5 3000:5 4000:5 5000:5 6000:5 8000:5 10000:5 F092015S159-1 F093015S209-1 F094015S309-1 F096015S409-1 F098015S609-1 F091025S809-1 F091225S809-1 F091525S809-1 F092025S809-1 F092525S809-1 F093025S809-1 F094025S809-1 F095025S809-1 F096025S809-1 F098025S809-1 F091035S809-1 0.3 B0.1 0.3 B0.2 0.3 B0.5 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 C150 C200 C300 C400 C600 C800 C800 C800 C800 C800 C800 C800 C800 C800 C800 C800 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 1.5 1.5 1.5 1.5 1.25 1.0 ----------------- ----------------- ----------------- 200/400:5 300/600:5 400/800:5 600/1200:5 1000/2000:5 1500/3000:5 F092015D109-1 F093015D209-1 F094015D309-1 F096015D409-1 F091025D409-1 F091525D809-1 0.3 B0.5/B0.9 0.3 B0.5/B1.8 0.3 B0.9/B1.8 0.3 B1.8/B1.8 0.3 B1.8/B1.8 0.3 B1.8/B1.8 C100/C200 C200/C400 C300/C600 C400/C800 C400/C800 C800/C800 2.0/2.0 2.0/2.0 2.0/2.0 2.0/2.0 2.0/2.0 2.0/1.5 ------- ------- ------- - Available in multi-ratio designs (full tap ratings same as single ratio above). - 1 Second Thermal/Mechanical Rating: 80x full winding Inom / Unlimited mechanical. - Available with a primary bar kit (maximum 5500A). Change last digit of catalog from 1 to 3. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 15 25000 Volt March 2008 16 LG–25–879 Current Transformer NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage LG(X)–25–6513 Current Transformer 25000 Volt Outdoor 25kV, 150kV BIL, Single, Dual & Multi Ratios Molded Resin, Window Type, Metering/Relaying application The LG(X)-25-6513 outdoor, window-type current transformer is rated for use on 25,000 volt systems with 150kV BIL. Primary current ratios are available from 400:5 to 10,000:5 at 60 Hertz (Hz) with a Rating Factor of up to 4.0. This dry-type, solid-cast current transformer will operate with high accuracy for metering or relay applications. mechanical description The core and coil assembly is wound and encapsulated in a molded cast resin with a 8 ¾” window porcelain primary bushing to provide high withstand capabilities. The high strength porcelain has a semi conductive interior with a pigtail lead to be connected to the primary conductor to equalize the voltage and prevent radio interference and corona. The secondary terminals are ¼”-20 copper studs with associated hardware located inside a removable terminal box with two (2) 1” NPT conduit hubs. accuracy performance The LG-25-6513 will operate with 0.3 Class accuracy for metering with burdens of B0.1 to B1.8 and up to C800 for some relay applications. The transformer is accurate through its Rating Factor, and can be used continuously to this level. The LGX25-6513 will operate with 0.15 Class high accuracy for metering applications with burdens of B0.1 to B1.8. The transformer maintains 0.3 accuracy from 1% of Inom through its Rating Factor, and can be used continuously to this level (for 0.15 accuracy range, see ratings specific to each ratio). March 2008 mounting The LG is designed for mounting in the upright or underhung position with the tube horizontal, or in the cantilever position with the tube vertical. CAUTION: Do not mount in the cantilever position with the tube horizontal, the base plate can collapse. Mounting holes are punched in the aluminum base plate. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 120% of the nominal system voltage. The unit is tested above operating voltage for traces of corona. A “corona free” label is bonded to the completed transformer as a guarantee of trouble-free service. options The LG can be offered in single or dual core designs. Contact factory for other needs. ORDERING INFO FOR LG-25-6513 HIGH ACCURACY LGX-25-6513 Accuracy/Burden Metering Relay Rating Factor Catalog Number 0.15/0.3 @ Burden 0.15/0.3 Acc Range Rating Factor Ratio Catalog Number* 200:5 300:5 400:5 600:5 800:5 1000:5 1200:5 1500:5 2000:5 2500:5 3000:5 4000:5 5000:5 6000:5 8000:5 10000:5 F040200S1 F040300S1 F040400S1 F040600S1 F040800S1 F041000S1 F041200S1 F041500S1 F042000S1 F042500S1 F043000S1 F044000S1 F045000S1 F046000S1 F048000S1 F0410000S1 0.3 B0.2 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.9 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 C50 C100 C100 C150 C200 C250 C300 C300 C400 C600 C800 C800 C800 C800 C800 C800 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 1.5 1.5 1.0 1.0 1.0 --F040400X1 F040600X1 F040800X1 F041000X1 F041200X1 F041500X1 F042000X1 -------- --B0.5 B0.9 B0.9 B0.9 B0.9 B0.9 B0.9 -------- --400/4 to 1200A 600/6 to 2400A 800/8 to 3200A 100/10 to 3000A 120/12 to 3600A 150/15 to 3000A 200/20 to 4000A -------- --3.0 4.0 4.0 3.0 3.0 2.0 2.0 -------- 200/400:5 300/600:5 400/800:5 600/1200:5 1000/2000:5 1500/3000:5 2000/4000:5 3000/6000:5 F040200D1 F040300D1 F040400D1 F040600D1 F041000D1 F041500D1 F042000D1 F043000D1 0.3 B0.5/B0.9 0.3 B0.5/B1.8 0.3 B0.9/B1.8 0.3 B0.9/B1.8 0.3 B1.8/B1.8 0.3 B1.8/B1.8 0.3 B1.8/B1.8 0.3 B1.8/B1.8 C100/C200 C200/C400 C300/C600 C150/C300 C200/C400 C400/C800 C400/C800 C400/C800 2.0/2.0 2.0/2.0 2.0/2.0 2.0/2.0 2.0/2.0 2.0/2.0 2.0/1.5 1.5/1.0 --------- --------- --------- --------- - Available in multi-ratio designs (full tap ratings same as single ratio above). - 1 Second Thermal/Mechanical Rating: 80x full winding Inom / Unlimited mechanical. * IC Approval (AE-1104) is noted by bold catalog number. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 17 25000 Volt March 2008 18 LG(X)–25–6513 Current Transformer NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage COF(CXM)–150 Current Transformer 25000 Volt Outdoor 25kV, 150kV BIL, Single, Dual & Multi Ratios Oil-Filled, Wound Type, Metering/Relaying March 2008 application The COF(CXM)-150 outdoor current transformer is rated for use on 25,000 volt systems with 150kV BIL. Primary current ratios are available from 5:5 to 3000:5 at 60 Hertz (Hz) with a Rating Factor of up to 4.0 (3200A max). This oil-filled current transformer will operate with high accuracy for metering or relay applications. mechanical description The tank dome is fabricated from carbon or stainless steel, depending on current rating. The units are pressure and vacuum tight and hermetically sealed at the factory to prevent breathing and oil contamination. Tank components are washed and coated with anticorrosive iron phosphate and then finished with ANSI 70 Gray baked-on electrostatic polyester powder. The bushing is ANSI 70 Gray, high strength porcelain with a high degree of stability for transportation and seismic withstand. The primary terminals are tin plated aluminum, NEMA 4-hole pads for units rated ≥400A (copper for units rated ≥2000A) and NEMA 2-hole pads for units rated <400A. A bypass protector is provided for all units rated below 1200:5 to protect from transients. The secondary terminals are #10 slotted screws on a short circuiting terminal block located behind a removable cover in the CT base with three (3) 1 ½” NPT conduit hubs. The ground terminal is a stainless steel NEMA 2-hole pad. The unit is fitted with a pressure relief valve, oil level gauge, and ½” drain valve. accuracy performance The COF-150 will operate with 0.3 Class accuracy for metering applications with burdens of B0.1 to B1.8. The unit can be designed with relay accuracy up to C800. The transformer is accurate through its Rating Factor, and can be used continuously to this level. The CXM-150 will operate with 0.15 Class high accuracy for metering applications with burdens of B0.1 to B1.8. The transformer maintains 0.15 Class accuracy from 0.5% of Inom through its Rating Factor, and can be used continuously to this level. mounting The COF(CXM) is designed for mounting on substations structures in an upright position with four mounting holes in the base. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Additional tests include dissipation and partial discharge tests. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 135% of the nominal system voltage. options The COF(CXM) is available with an Extra Creep Bushing, Polymer Bushing, Stainless Steel Tank, 4kV spark gap and/or -50°C oil. The unit can be offered in single, dual or multiple core designs. Contact factory for other needs. ORDERING INFO FOR COF-150 HIGH ACCURACY CXM-150 Ratio Catalog Number Accuracy/ Burden Rating Factor Catalog Number 0.15 B1.8 Acc Range Rating Factor 5:5 10:5 F950005SA F950010SA 0.3 B1.8 0.3 B1.8 1.5 1.5 F890005SA F890010SA 0.025 to 20A 0.05 to 40A 4.0 4.0 … … … … … … … 150:5 200:5 F950150SA F950200SA 0.3 B1.8 0.3 B1.8 1.5 1.5 F890150SA F890200SA 0.75 to 600A 1 to 800A 4.0 4.0 … … … F893000SA 15 to 3200A 1.07 5/10:5 10/20:5 F950010DA F950020DA 0.3 B1.8/B1.8 0.3 B1.8/B1.8 2.0/1.5 2.0/1.5 --------- --------- --------- … … 1.0 … … 0.3 B1.8 … … F953000SA … … 3000:5 100/200:5 150/300:5 F950200DA F950300DA 0.3 B1.8/B1.8 0.3 B1.8/B1.8 2.0/1.5 2.0/1.5 … … … … 1000/2000:5 1500/3000:5 F952000DA F953000DA 0.3 B1.8/B1.8 0.3 B1.8/B1.8 2.0/1.5 2.0/1.0 - Available in multi-ratio designs (full tap ratings same as single ratio above). - 1 Second Thermal/Mechanical Rating: Single Ratio (150x lnom), Dual Ratio (75x full winding Inom), 144kA max. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 19 25000 Volt March 2008 20 COF(CXM)–150 Current Transformer NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage KM–25–973 1 Ø Metering Unit 25000 Volt Outdoor 25kV, 150kV BIL, Single Ratios Molded Epoxy, Wound Type, 1Ø Metering March 2008 application The KM-25-973 outdoor, single phase metering unit is rated for use on 25,000 volt systems with 150kV BIL. Primary current ratios are available from 5:5 to 1200:5 at 60 Hertz (Hz) with a Rating Factor of up to 1.5 (1200A max). Primary voltage ratios are available from 100:1 to 200:1 for use on 25,000 volt, Grd Y systems. This dry-type, solid-cast metering unit will operate with high accuracy for metering applications. mechanical description The core and coil assembly is wound and encapsulated in a high dielectric strength epoxy resin to provide high withstand capabilities. The external line to ground insulation consists of a cycloaliphatic epoxy resin that provides excellent arc track properties in addition to ultraviolet resistance and strong physical strength. A high voltage stress ring around the top of the unit is supplied to control RIV and partial discharge. The primary terminals are flat, tin-plated copper with standard NEMA 2-hole pattern suitable for various size conductors. The clamp-type post secondary terminals have ¼”-20 slotted screws and associated hardware located inside a removable terminal box with two (2) 1” NPT conduit hubs and a 1” knockout on the bottom of the box. accuracy performance The KM-25-973 will operate, for the current transformer, with 0.3 Class accuracy for metering with burdens of B0.1 to B0.5. The CT is accurate through its Rating Factor, and can be used continuously to this level. The unit will operate, for the voltage transformer, with 0.3 Class accuracy for metering with burdens of 0, W, X, M and Y. The VT is accurate from 90% to 110% of rated primary voltage. mounting The KM is designed for mounting on poles or substation structures in a vertical, horizontal or underhung position. The mounting holes in the heavy galvanized steel plate are punched to industry standard dimensions for interchangeability in the field. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 120% of the nominal system voltage. options A primary spark gap is available for capacitor bank or other applications where high transients will be present. 90° angle primary bus adapters can be supplied to place the two terminal surfaces parallel to one another. Contact factory for other needs. ORDERING INFO FOR KM-25-973 HIGH ACCURACY N/A Voltage Ratings Ratio* - 120:1 Pri*:Sec - 14400:120 Current Ratio Catalog Number** Accuracy/ Burden Rating Factor Catalog Number* Accuracy/ Burden Rating Factor 5:5 10:5 15:5 20:5 25:5 30:5 40:5 50:5 75:5 100:5 150:5 200:5 300:5 400:5 600:5 800:5 1000:5 1200:5 F9800505S120S F9801005S120S F9801505S120S F9802005S120S F9802505S120S F9803005S120S F9804005S120S F9805005S120S F9807505S120S F9801015S120S F9801515S120S F9802015S120S F9803015S120S F9804015S120S F9806015S120S F9808015S120S F9801025S120S F9801225S120S 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 ------------------- ------------------- ------------------- Accuracy/Burden 0.3 0,W,X,M,Y 1.2 Z Accuracy/Burden -- - Thermal Burden Rating (Typical): 750VA. - Overvoltage Rating: 1.25x cont., 1.5x 30 sec. - 1 Second Thermal/Mechanical Rating: 100x/270x Inom (80x/200x for 600:5, 70x/175x for 800:5, 50x/125x for above 800:5). * Other Primary Voltage Ratings Available, contact factory. ** IC Approval AE-1474 is noted by bold catalog number. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 21 25000 Volt March 2008 22 KM–25–973 1 Ø Metering Unit NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage JS(JXM)–150 1 Ø Metering Unit 25000 Volt Outdoor 25kV, 150kV BIL, Single, Dual & Multi Ratios Oil-Filled, Wound Type, 1Ø Metering March 2008 of rated primary voltage. The JXM-150 will operate, for the current transformer, with 0.15 Class accuracy for metering with burdens of B0.1 to B1.8. The CT maintains 0.15 Class accuracy from 0.5% of Inom through its Rating Factor, and can be used continuously to this level. The unit will operate, for the voltage transformer, with 0.15 Class accuracy for metering with burdens of 0, W, X, M, Y and Z, as well as 0.3 ZZ. The VT is accurate from 90% to 110% of rated primary voltage. application The JS(JXM)-150 outdoor single phase metering unit is rated for use on 25,000 volt systems with 150kV BIL. Primary current ratios are 5:5 to 1200:5 at 60 Hertz (Hz) with a Rating Factor of up to 4.0 (1200A max). Primary voltage ratios are available from 100:1 to 200:1 for use on 25,000 volt, Grd Y systems. This oilfilled metering unit will operate with high accuracy for metering applications. mechanical description The tank is a standard distribution transformer tank made of heavy gauge sheet steel with a seam welded bottom plate and a dome shaped cover. The tank is washed and coated with anticorrosive iron phosphate and then finished with an ANSI 70 Gray baked-on electrostatic polyester powder. The primary bushings are ANSI 70 Gray, high strength porcelain with a tin plated bronze, NEMA 1-hole primary terminal. NEMA 4-hole primary terminals are provided for units rated ≥200A. A bypass protector is provided for all units rated below 1200:5 to protect from transients. A 5kV H0 Bushing is included for power factor measurements and is connected to the tank ground, a tin plated bronze eyebolt. The secondary terminals consist of a feed thru block with ¼”-20 copper studs and associated hardware located inside a removable terminal box with three (3) 1 ½” NPT conduit hubs. The unit also includes a pressure relief valve. mounting The JS(JXM) is designed for mounting on poles or substation structures in an upright position with ANSI type “A” hanger brackets or optional mounting feet. NOTE: Must be installed per NESC electrical clearances. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Additional tests include dissipation and partial discharge tests. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 135% of the nominal system voltage. accuracy performance The JS-150 will operate, for the current transformer, with 0.3 Class accuracy for metering with burdens of B0.1 to B1.8. The CT is accurate through its Rating Factor, and can be used continuously to this level. The unit will operate, for the voltage transformer, with 0.3 Class accuracy for metering with burdens of 0, W, X, M, Y, Z and ZZ. The VT is accurate from 90% to 110% options The JS(JXM) is available with Lighting Arrestors, NEMA 4-hole Primary Terminals, NEMA 2-hole Ground Pad, Mounting Feet, Stainless Steel Tank, 4kV Spark Gap, Oil Level Indicator, Oil Drain Valve, and/or -50°C oil. Contact factory for other needs. ORDERING INFO FOR JS-150 HIGH ACCURACY JXM-150 Voltage Ratings Ratio* - 120:1 Pri*:Sec - 14400:120 Current Ratio Catalog Number** Accuracy/ Burden Rating Factor Catalog Number 0.15 B1.8 Acc Range Rating Factor 10:5 20:5 F80001S12EA F80002S12EA 0.3 B1.8 0.3 B1.8 1.5 1.5 F79001S12EA F79002S12EA 0.05 to 40A 0.1 to 80A 4.0 4.0 Accuracy/Burden 0.3 0,W,X,M,Y,Z,ZZ Accuracy/Burden 0.15 0,W,X,M,Y,Z, 0.3 ZZ … … … … … … … 150:5 200:5 F80015S12EA F80020S12EA 0.3 B1.8 0.3 B1.8 1.5 1.5 F79015S12EA F79020S12EA 0.75 to 600A 1 to 800A 4.0 4.0 … … … F79100S12EA F79120S12EA 5 to 1200A 6 to 1200A 1.2 1.0 5/10:5 10/20:5 F80001D12EA F80002D12EA 0.3 B1.8/B1.8 0.3 B1.8/B1.8 2.0/1.5 2.0/1.5 ------ ------ ------ … … 1.2 1.0 … … 0.3 B1.8 0.3 B1.8 … … F80100S12EA F80120S12EA … … 1000:5 1200:5 500/1000:5 600/1200:5 F80100D12EA F80120D12EA 0.3 B1.8/B1.8 0.3 B1.8/B1.8 2.0/1.2 2.0/1.0 - Available in multi-ratio designs. - Thermal Burden Rating (Typical): 4000VA. - Overvoltage Rating: 1.1x cont., 1.9x 8 hours. - 1 Second Thermal/Mechanical Rating: Single Ratio (150x lnom), Dual Ratio (75x full winding Inom), 144kA max. * Other Primary Voltage Ratings Available, contact factory. ** IC Approval T-332 noted by bold catalog number. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 23 25000 Volt March 2008 24 JS(JXM)–150 1 Ø Metering Unit NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage MVCT(MXM)–150 3 Ø Metering Unit Outdoor 25kV, 150kV BIL, Single, Dual & Multi Ratios Oil-Filled, Wound Type, 3Ø Metering 25000 Volt March 2008 for the current transformers, with 0.15 Class high accuracy for metering applications with burdens of B0.1 to B1.8. The transformer maintains 0.15 Class accuracy from 0.5% of Inom through its Rating Factor, and can be used continuously to this level. The unit will operate, for the voltage transformers, with 0.15 Class accuracy for metering with burdens of 0, W, X, M, Y and Z, as well as 0.3 ZZ. The VT’s are accurate from 90% to 110% of rated primary voltage. application The MVCT(MXM)-150 outdoor three phase metering unit is rated for use on 25,000 volt systems with 150kV BIL. Primary current ratios are 5:5 to 1200:5 for 60 Hertz (Hz) with a Rating Factor of up to 4.0 (1200A max). Primary voltage ratios are available from 100:1 to 200:1 for use on 25,000 volt systems. This oilfilled metering unit will operate with high accuracy for 2, 2 ½ or 3 element metering applications. mechanical description The unit is built of heavy walled steel construction similar to proven distribution and small power transformer construction and is strongly braced to withstand both electrical and mechanical stresses. The tank is washed and coated with anticorrosive iron phosphate and then finished with an ANSI 70 Gray baked-on electrostatic polyester powder. The primary bushings are ANSI 70 Gray, high strength porcelain with tin plated bronze, NEMA 4-hole primary terminals. The secondary terminals consist of a feed thru block with ¼”-20 copper studs and associated hardware located inside a terminal box with three (3) 1 ½” NPT conduit hubs. The ground terminal is a stainless steel NEMA 2-hole pad. The unit includes a pressure relief valve, CT by-pass protectors, 5kV H0 Bushing (for 3P 4W designs), ½” oil drain valve, and a magnetic type oil level gauge which is easily read from a distance. mounting The MVCT(MXM) is designed for overhead mounting on poles or substation structures in an upright position with ANSI type “C” hanger brackets or four mounting holes in the base. NOTE: Must be installed per NESC electrical clearances. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Additional tests include dissipation and partial discharge tests. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 135% of the nominal system voltage. accuracy performance The MVCT-150 will operate, for the current transformers, with 0.3 Class accuracy for metering with burdens of B0.1 to B1.8. The CT’s are accurate through their Rating Factor, and can be used continuously to this level. The unit will operate, for the voltage transformers, with 0.3 Class accuracy for metering with burdens options of 0, W, X, M, Y, Z and ZZ. The VT’s are accurate from 90% The MVCT(MXM) is available with a Stainless Steel Tank, 4kV to 110% of rated primary voltage. The MXM-150 will operate, Spark Gaps and/or -50°C oil. Contact factory for other needs. ORDERING INFO FOR MVCT-150 Ratio* - 120:1 Voltage Ratings Pri*:Sec - 14400:120 Accuracy/Burden 0.3 0,W,X,M,Y,Z,ZZ HIGH ACCURACY MXM-150 Accuracy/Burden 0.15 0,W,X,M,Y,Z, 0.3 ZZ Current Ratio Catalog Number (3P 4W)** Accuracy/ Burden Rating Factor Catalog Number (3P 4W) 0.15 B1.8 Acc Range Rating Factor 10:5 20:5 F88001S12CA F88002S12CA 0.3 B1.8 0.3 B1.8 1.5 1.5 F86001S12CA F86002S12CA 0.05 to 40A 0.1 to 80A 4.0 4.0 … … … … … … … 150:5 200:5 F88015S12CA F88020S12CA 0.3 B1.8 0.3 B1.8 1.5 1.5 F86015S12CA F86020S12CA 0.75 to 600A 1 to 800A 4.0 4.0 … … … F86100S12CA F86120S12CA 5 to 1200A 6 to 1200A 1.2 1.0 5/10:5 10/20:5 F88001D12CA F88002D12CA 0.3 B1.8/B1.8 0.3 B1.8/B1.8 2.0/1.5 2.0/1.5 ------ ------ ------ … … 1.2 1.0 … … 0.3 B1.8 0.3 B1.8 … … F88100S12CA F88120S12CA … … 1000:5 1200:5 500/1000:5 600/1200:5 F88100D12CA F88120D12CA 0.3 B1.8/B1.8 0.3 B1.8/B1.8 2.0/1.2 2.0/1.0 - Available in multi-ratio designs. - Thermal Burden Rating (Typical): 6000VA (2000VA/phase). - Overvoltage Rating: 1.1x cont., 1.9x 8 hours (3P 4W). - 1 Second Thermal/Mechanical Rating: Single Ratio (150x lnom), Dual Ratio (75x full winding Inom), 144kA max. * Other Primary Voltage Ratings Available, contact factory. ** For 3P 3W, change catalog digits “88” to “87”. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 25 25000 Volt March 2008 26 MVCT(MXM)–150 3 Ø Metering Unit NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage ME–025 3 Ø Metering Rack Outdoor 25kV, 150kV BIL, Single & Dual Ratios Pre-Wired, Molded Epoxy CTs & VTs, 3Ø Metering 25000 Volt March 2008 application The ME-025 outdoor, three phase metering rack is rated for use on 25,000 volt systems with 150kV BIL. Current transformers have ratios available from 5:5 to 1200:5 for 60 Hertz (Hz) with a Rating Factor of up to 3.0 (1800A max). Voltage transformers have ratios available from 100:1 to 200:1 for use on 25,000 volt systems. This metering rack will operate with high accuracy for 1, 2, 2 ½ or 3 element metering applications. mechanical description The rack is made of lightweight aluminum and incorporates the BB-25-973 or BB-25-974 current transformers mounted vertically and the PTT-150-9710(G) voltage transformers mounted horizontally. The CT primary terminals are flat, tin-plated copper with standard NEMA 2-hole pattern suitable for various size conductors. The VT primary terminals are M12 stud with a compression type lug for #8 - #2 AWG conductors. The secondary terminals are pre-wired through protective conduit to a 10 position test switch in standard red/black colors mounted to the rack. accuracy performance The ME-025 will operate, for the current transformers, with 0.3 Class accuracy for metering with burdens of B0.1 up to B1.8. The CT’s are accurate through their Rating Factor, and can be used continuously to this level. The rack will operate, for the voltage transformers, with 0.3 Class accuracy for metering with burdens of 0, W, X, M and Y. The VT’s are accurate from 90% to 110% of rated primary voltage. mounting The ME rack is designed for mounting on poles in an upright position. There are two galvanized steel mounting bolts supplied to attach to the pole. testing The units are individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. An additional partial discharge test is performed to guarantee the units are free of partial discharge through 120% of the nominal system voltage. The secondary pre-wiring is tested for correct polarity and type of transformer to minimize damage due to misconnection. options The ME rack is available with a 35’ S/O outdoor cable extension to a test switch/meter socket, a pre-programmed GE type KV2C Form 9S meter, and/or Canadian color-code or other color scheme wiring. CT’s and/or VT’s are available with 0.15 Class high accuracy. Transformers can be mounted with the VT’s vertical and CT’s horizontal, or rack can be designed with only VT’s or only CT’s. Contact factory for other needs. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 27 25000 Volt March 2008 28 ME–025 3 Ø Metering Rack NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage MK–25 3 Ø Metering Rack Outdoor 25kV, 150kV BIL, Single Ratios Pre-Wired, Molded Epoxy CT/VTs, 3Ø Metering 25000 Volt March 2008 application The MK-25 outdoor, three phase metering rack is rated for use on 25,000 volt systems with 150kV BIL. Primary current ratios are available from 5:5 to 1200:5 for 60 Hertz (Hz) with a Rating Factor of up to 1.5 (1200A max). Primary voltage ratios are available from 100:1 to 120:1 for use on 25,000 volt, Grd Y systems. This metering rack will operate with high accuracy for 1, 2 or 3 element metering applications. mechanical description The rack is made of lightweight aluminum and incorporates the KM-25-973 metering units mounted either vertically or horizontally. The primary terminals are flat, tin-plated copper with standard NEMA 2-hole pattern suitable for various size conductors. The secondary terminals are pre-wired through protective conduit to a 10 position test switch in standard red/black colors mounted to the rack. accuracy performance The MK-25 will operate, for the current transformers, with 0.3 Class accuracy for metering with burdens of B0.1 to B0.5. The CT’s are accurate through their Rating Factor, and can be used continuously to this level. The rack will operate, for the voltage transformers, with 0.3 Class accuracy for metering with burdens of 0, W, X, M and Y. The VT’s are accurate from 90% to 110% of rated primary voltage. mounting The MK rack is designed for mounting on poles in an upright position. There are two galvanized steel mounting bolts supplied to attach to the pole. testing The units are individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. An additional partial discharge test is performed to guarantee the units are free of partial discharge through 120% of the nominal system voltage. The secondary pre-wiring is tested for correct polarity and type of transformer to minimize damage due to misconnection. options The MK rack is available with a 35’ S/O outdoor cable extension to a test switch/meter socket, a pre-programmed GE type KV2C Form 9S meter, and/or Canadian color-code or other color scheme wiring. Contact factory for other needs. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 29 25000 Volt March 2008 30 MK–25 3 Ø Metering Rack NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage MP–025 3 Ø Metering Cubicle Outdoor 25kV, 150kV BIL, Single & Dual Ratios Pre-Wired, Molded Epoxy CTs & VTs, 3Ø Metering 25000 Volt March 2008 application The MP-025 outdoor, three phase metering, pad-mounted cubicle is rated for use on 25,000 volt systems with 150kV BIL and also complies with ANSI C57.12.28. Current transformers have ratios available from 5:5 to 1200:5 for 60 Hertz (Hz) with a Rating Factor of up to 3.0 (1200A max). Voltage transformers have ratios available from 100:1 to 200:1 for use on 25,000 volt systems. This metering cubicle will operate with high accuracy for 1, 2, 2 ½ or 3 element metering applications. mechanical description The cubicle is made of #12 AWG mild steel with Munsell Green #7GY 3.29/1.5 powder finish and incorporates the BB-25-973 or BB-25-974 current transformers and the PTT-150-9710(G) voltage transformers. The cubicle doors are pad-lockable with three point latch and a penta-head bolt and have screened vents on the transformer side. White GPO-3 glass reinforced polyester barriers are built-in between phases and the live side. The primary connections can be radial or loop feed with one or two load taps. The connections can be either 200A loadbreak bushing wells or 600A non-loadbreak inserts, both are ANSI/IEEE 386 compliant. The secondary terminals are pre-wired to a 10 position test switch and 9S meter socket in standard red/black colors on the outside right wall when facing the elbow side of the cubicle. accuracy performance The MP-025 will operate, for the current transformers, with 0.3 Class accuracy for metering with burdens of B0.1 up to B1.8. The CT’s are accurate through their Rating Factor, and can be used continuously to this level. The cubicle will operate, for the voltage transformers, with 0.3 Class accuracy for metering with burdens of 0, W, X, M and Y. The VT’s are accurate from 90% to 110% of rated primary voltage. mounting The MP cubicle is designed for pad-mount use. testing The transformer units are individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. An additional partial discharge test is performed to guarantee the units are free of partial discharge through 120% of the nominal system voltage. The secondary pre-wiring is tested for correct polarity and type of transformer to minimize damage due to misconnection. options The MP cubicle is available with the test switch on the inside wall of the cubicle to allow wiring to a remote meter socket. Unit is also available with only CT’s or VT’s. Canadian color-code or other color scheme wiring can be provided. CT’s and/or VT’s are available with 0.15 Class high accuracy. Contact factory for other needs. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 31 25000 Volt March 2008 32 MP–025 3 Ø Metering Cubicle NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage KCB–24 1 Ø Metering Unit 25000 Volt Indoor 25kV, 125kV BIL, Single Ratios Molded Epoxy, Wound Type, 1Ø Metering March 2008 application The KCB-24 indoor, dead-front, single phase metering unit is rated for use on 25,000 volt systems with 125kV BIL. Primary current ratios are available from 5:5 to 200:5 at 60 Hertz (Hz) with a Rating Factor of up to 3.0 (200A max). Primary voltage ratios are available for 100:1 to 120:1 for use on 25,000 volt, Grd Y systems. This dry-type, solid-cast metering unit will operate with high accuracy for metering applications. mechanical description The core and coil assembly is wound and encapsulated in a high dielectric strength epoxy resin to provide high withstand capabilities. The entire surface of the transformer is coated with a conductive layer that is intended to be solidly grounded when energized. This allows for compact mounting inside switchgear or enclosures. The primary terminals are standard 200 Ampere rated dead-front bushing well construction and can be connected using industry standard inserts and elbow connectors. The secondary terminals are ¼”-20 slotted screws with flat and lock washers located inside a metallic terminal cover with two (2) 1” NPT conduit hubs, one sealed and one left open for conduit entrance. The ground terminal is provided inside the terminal box along with a manually operated CT secondary shorting device for safety purposes. accuracy performance The KCB-24 will operate, for the current transformer, with 0.3 Class accuracy for metering with burdens of B0.1 to B0.5. The CT is accurate through its Rating Factor, and can be used continuously to this level. The unit will operate, for the voltage transformer, with 0.3 Class accuracy for metering with burdens of 0, W, X, M and Y. The VT is accurate from 90% to 110% of rated primary voltage. mounting The KCB is designed for mounting inside switchgear, padmounted enclosures, or vault applications. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 120% of the nominal system voltage. options Unit is also available as a CT or VT only. Contact factory for other needs. ORDERING INFO FOR KCB-24 HIGH ACCURACY MODEL N/A Voltage Ratings Ratio* - 120:1 Pri*:Sec - 14400:120 Current Ratio Catalog Number Accuracy/ Burden Rating Factor Catalog Number* Accuracy/ Burden Rating Factor 5:5 10:5 15:5 20:5 25:5 30:5 40:5 50:5 75:5 100:5 150:5 200:5 F9900505S120S F9901005S120S F9901505S120S F9902005S120S F9902505S120S F9903005S120S F9904005S120S F9905005S120S F9907505S120S F9901015S120S F9901515S120S F9902015S120S 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 2.67 2.0 1.33 1.0 ------------- ------------- ------------- Accuracy/Burden 0.3 0,W,X,M,Y 1.2 Z Accuracy/Burden 0.3 0,W,X,M,Y 1.2 Z - Thermal Burden Rating(Typical): 750VA. - Overvoltage Rating: 1.1x cont. - 1 Second Thermal/Mechanical Rating: 100x/270x Inom. * Other Primary Voltage Ratings Available, contact factory. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 33 25000 Volt March 2008 34 KCB–24 1 Ø Metering Unit NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage MI–25 3 Ø Metering Cubicle Outdoor 25kV, 125kV BIL, Single Ratios Pre-Wired, Molded Epoxy CT/VTs, 3Ø Metering 25000 Volt March 2008 application The MI-25 outdoor, three phase metering, pad-mounted cubicle is rated for use on 25,000 volt systems with 125kV BIL and also complies with ANSI C57.12.28. Current transformers have ratios available from 5:5 to 200:5 for 60 Hertz (Hz) with a Rating Factor of up to 3.0 (200A max). Voltage transformers have ratios available for 100:1 to 120:1 for use on 25,000 volt, Grd Y systems. This metering cubicle will operate with high accuracy for 1, 2 or 3 element metering applications. mechanical description The cubicle is made of #12 AWG stainless steel with Munsell Green #7GY 3.29/1.5 powder finish and incorporates the KCB-24 metering units. The cubicle doors are pad-lockable with a three point latch and a penta-head bolt and have screened vents on the removable transformer side door. The primary connections are radial with one load tap (loop feed configuration may be available by use of feed-through inserts). The connections are 200A loadbreak bushing wells, which are ANSI/IEEE 386 compliant. The secondary terminals are pre-wired to a 10 position test switch and 9S meter socket in standard red/black colors on the outside right wall when facing the elbow side of the cubicle. accuracy performance The MI-25 will operate, for the current transformers, with 0.3 Class accuracy for metering with burdens of B0.1 to B0.5 The CT’s are accurate through their Rating Factor, and can be used continuously to this level. The cubicle will operate, for the voltage transformers, with 0.3 Class accuracy for metering with burdens of 0, W, X, M and Y. The VT’s are accurate from 90% to 110% of rated primary voltage. mounting The MI cubicle is designed for pad-mount use. testing The transformer units are individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. An additional partial discharge test is performed to guarantee the units are free of partial discharge through 120% of the nominal system voltage. The secondary pre-wiring is tested for correct polarity and type of transformer to minimize damage due to misconnection. options The MI cubicle is available with a terminal block on the inside wall of the cubicle to allow wiring to a remote meter socket. Unit is also available with only CT’s or VT’s. Canadian color-code or other color scheme wiring can be provided. Contact factory for other needs. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 35 25000 Volt March 2008 36 MI–25 3 Ø Metering Cubicle NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage
© Copyright 2025 Paperzz