Technical Information CCS120 Sensor for total chlorine Application • • • • Drinking water conditioning Pool water conditioning Service water conditioning Waste water treatment Your benefits • Flow and immersion installation • Works with the well known assemblies: CCA250 CYA611 • Works with the transmitter CCM223/253 • Retrofitable in existing applications • Sensor selection via menu of the transmitter CCM223/253 • Temperature sensor NTC 10K TI388C/07/en/07.06 51517374 CCS120 Function and system design Measuring principle The amperometric sensor is based on the conversion of the measuring variable chlorine in electrical current. Two electrodes covered by an electrolyte are in contact to the medium via a membrane. It has a platinum working electrode and a silver halogenide coated counter or reference electrode. The chlorine compounds contained in the medium diffuse through the membrane. The constant polarisation voltage between the two electrodes instigates the electrochemical reaction of the chlorine compounds on the working electrode. The resulting current is measured as a primary signal (amperometric measurement principle). It is proportional to the chlorine concentration within the sensor’s operating range and only slightly pH dependant for this type of sensor. The primary signal is converted by the amplifier electronics of the sensor into a 0 ... 5 µA output signal which is displayed by the transmitter. Function The sensor CCS120 is a membrane-capped amperometric two electrode sensor. It is used for continuous measurement of total chlorine. Total chlorine consists of free chlorine (HOCl, OCl-) and bound chlorine (chloramines). To calibrate the measuring system, determine the content of chlorine using the DPD 1 / DPD 4 method. To do so, you need a photometer with the pertaining reagents. The determined value is the calibration value for the transmitter. Measuring system A complete measuring system in the flow mode comprises at least: • Chlorine sensor • Transmitter Liquisys M CCM223/253 • Special measuring cable • Flow assembly 8 9 4 5 0.42 mg/l 25.0 ¡C REL1 ALARM CAL REL REL2 REL1 E 6 REL2 7 3 2 1 a0001691 Measuring system in the flow mode (example) 1 2 3 4 5 Flow assembly CCA250 Medium inlet Inductive proximity switch for flow monitoring Mounting place for pH/redox sensor Chlorine sensor CCS120 6 7 8 9 Medium outlet Sampling tap Measuring cable CPK9-N*A1B Transmitter The described above measuring system is available as CCE-station (fully mounted on a board). 2 Endress+Hauser CCS120 A complete measuring system in the immersion mode comprises at least: • Chlorine sensor • Transmitter Liquisys M CCM223/253 • Special measuring cable • Immersion assembly 1 2 0.42 mg/l 25.0 ¡C REL1 ALARM CAL REL REL2 REL1 E REL2 6 3 4 5 a0001791 Measuring system in the immersion mode (example) 1 2 3 Junction box VBM Transmitter Measuring cable CYK71 4 5 Immersion assembly CYA611-0B Chlorine sensor CCS120 Input Measured variables Total chlorine Measuring range 0.1 ... 10 mg/l Standard slope 110 ... 120 nA/(mg/l) Free chlorine (Cl2 (dissolved), HOCl, OCl-) Bound chlorine (chloramines) Organic-bound chlorine (e.g. cyanuric acid derivates) Output Output signal 0 ... 5 µA for connection to transmitter Liquisys M CCM223/253 with software version 2.32 or later Power supply Power supply Endress+Hauser 15 V DC, 10 mA 3 CCS120 Performance characteristics Response time T90 approx. 60 s (as concentration rises and falls) Resolution 0.01 mg/l pH range 5.5 ... 9.5 pH dependency: jump from pH 7 to pH 8: approx. -10 % for free chlorine Conductivity range 0.03 ... 40 mS/cm Temperature range 5 ... 45 °C (41 ... 113 °F), no quick changes in temperature allowed Pressure Medium in the CCA250 assembly: max. 1 bar (14.5 psi) Flow optimum: minimum: maximum: 40 ... 60 l/h (10.56 ... 15.84 US.gal/h) 30 l/h (7.92 US.gal/h) 100 l/h (26.40 US.gal/h) Minimum input flow velocity optimum: minimum: maximum: 20 ... 30 cm/s (0.7 ... 1.0 ft/s) 15 cm/s (0.5 ft/s) 50 cm/s (1.6 ft/s) Cross sensitivity Oxidising reagents e.g. bromine, iodine, ozone, chlorine dioxide, permanganates result in false positive results. Reducing reagents like sulphides, sulphites, tiosulphates, and hydrazine result in false negative results. Service life membrane cap Typically 3 - 6 months, depending on water quality Installation Installation conditions The minimum flow may not drop below 30 l/h (7.92 US.gal/h). The minimum input flow velocity may not drop below XXX. Installation in flow assembly CCA250 or pendulum assembly CYA611-0B with thread NPT 3/4". Environment Storage temperature Filled with electrolyte: Without electrolyte: Ingress protection IP 68 4 5 ... 50 °C (41 ... 122 °F) -20 ... +60 °C (-4 ... +140 °F) Endress+Hauser CCS120 Mechanical construction Dimensions 27/1.06 NPT 3/4 183/7.20 Ø 29/ 1.14 Ø 36/ 1.42 Ø 25/ 0.98 74/2.91 Ø 28.8/ 1.13 mm/inch a0003082 Dimensions Weight approx. 0.14 kg (0.31 lbs) Materials Sensor shaft: Membrane cap: Temperature sensor NTC 10 kΩ at 25 °C (77 °F) Plug-in head TOP68 plug-in head Cable length max. 15 m (49.2 ft) Endress+Hauser PVC PPE 5 CCS120 Ordering information Sensor CCS120 Mesuring range A 0.1 ... 10 mg/l Head type S Thread NPT 3/4"; plug TOP 68 Options 0 none CCS120- CCE system complete order code The CCE Compact chlorine system (mounted on a board) consists of four modules: Module Order no. Sensor CCS120 CCS120-xxx CCE-1 board 50041731 Measuring cable for CCE1 51517204 Liquisys M (of your choice) CCM253..... (see Technical Information TI214C/07/en) In North America the four modules are available as a complete package (115 V, CSA). Order no. 51517437 Accessories Connection accessories Junction box VBM • For cable extension, with 10 terminals • IP 65 / NEMA 4X • Material: aluminum • Order numbers: – cable entry Pg 13.5: 50003987 – cable entry NPT ½": 51500177 • Measuring cable CCS120-1M, cable length: 1 m (3.28 ft), for compact chlorine system CCE1 order no. 51517204 • Special measuring cable CPK9-N*A1B internal PM wire For sensors with TOP68 plug-in head, for high-temperature and high-pressure applications, IP 68 Ordering acc. to product structure, see Technical Information (TI118C/07/en) Installation accessories • Flow assembly CCA250 for chlorine, chlorine dioxide, pH and redox; Ordering acc. to product structure, see Technical Information (TI062C/07/en) • Immersion assembly Dipfit W CYA611-0B for sensor immersion in basins, open channels and tanks, PVC; Ordering acc. to product structure (Technical Information TI166C/07/en) • Compact chlorine system CCE1 Factory-assembled and wired panel for transmitter with flow assembly CCA250-A1; see also Technical Information TI014C/07/en Transmitter 6 • Liquisys M CCM223/253 Transmitter for chlorine, field or panel-mounted housing, Hart® or PROFIBUS available, Ordering acc. to product structure, see Technical Information (TI214C/07/en) Endress+Hauser CCS120 Maintenance • Photometer CCM182; microprocessor-controlled photometer for chlorine, pH value, cyanuric acid; Chlorine measuring range: 0.05 to 6 mg/l pH measuring range: 6.5 to 8.4 • Electrolyte for CCS120, 50 ml order no. 51516343 • Service kit for CCS120, consists of 2 membrane caps and 1 bottle of electrolyte (50 ml) order no. 51517284 Documentation Transmitters • Liquisys M CCM223/253, Technical Information TI214C/07/en; order no. 51502336 Compact system • Compact chlorine system CCE1, Technical Information TI014C/07/en; order no. 50050696 Measuring cables • CPK1-12, Technical Information TI118C/07/en; order no. 50068526 Assemblies • Flow assembly CCA250, Technical Information TI062C/07/en; order no. 50057220 • Immersion assembly CYA611, Technical Information TI166C/07/en; order no. 50085985 Endress+Hauser 7 International Head Quarters Endress+Hauser GmbH+Co. KG Instruments International Colmarer Str. 6 79576 Weil am Rhein Deutschland Tel. +49 76 21 9 75 02 Fax +49 76 21 9 75 34 5 www.endress.com [email protected] TI388C/07/en/07.06 51517374 Printed in Germany / FM+SGML 6.0 / DT Technical Information Chloromax CCS142D Digital sensor with Memosens technology for determining free chlorine Membrane-covered amperometric sensor for process and drinking water applications Application Oxidants such as chlorine or inorganic chlorine compounds are used to disinfect water. They must be dosed immediately, depending on the operating conditions. If the concentrations are too low, this could jeopardize the disinfection process. On the other hand, concentrations which are too high can cause corrosion, skin irritation and affect the taste of the water. The CCS142D chlorine sensor is used to measure free chlorine in the following areas: • Drinking water • Process water • Industrial water treatment Your benefits • Sensor with digital signal processing: – Not sensitive to electromagnetic interference thanks to digital communication with the transmitter – Calibration data saved in the sensor, making it possible to calibrate at any transmitter or location and install subsequently at the measuring point • Ultimate measuring reliability: – Measurement practically independent of the flow at flow velocities above 15 cm/s (~0.5 ft/s) – Long calibration and maintenance intervals – No change in measured value in the event of fluctuations in conductivity • Membrane-covered sensor, therefore: – Easy membrane replacement thanks to prefabricated membrane head – Minimum maintenance • Zero-point calibration not required. No complex installation of an activated carbon filter, as found with open chlorine sensors TI419C/07/EN/01.11 71128490 Chloromax CCS142D Function and system design Measuring principle The concentration of free chlorine is determined according to the amperometric measuring principle. The hypochlorous acid (HOCl) contained in the medium diffuses through the sensor membrane and is reduced to chloride ions (Cl-) on the gold cathode. On the silver anode, silver is oxidized to silver chloride. The electron release of the gold cathode and electron acceptance on the silver anode result in a current flow which is proportional to the free chlorine concentration in the medium under constant conditions. The concentration of hypochlorous acid in the medium depends on the pH value. This dependence can be compensated by measuring the pH value in the flow assembly. The transmitter transforms the current signal into the measuring unit concentration in mg/l. Function The membrane-covered sensor CCS142D consists of a cathode (working electrode) and an anode (counterelectrode) in an electrolyte which is separated from the medium by a membrane. The membrane prevents the electrolyte from leaking and protects against contaminant penetration. The measuring system is calibrated by determining the free chlorine based on the DPD method (photometric method). The calibration value determined is entered in the transmitter. Measuring system A complete measuring system consists of: • A CCS142D chlorine sensor • An assembly, e.g. Flowfit CCA250 • A Memosens data cable CYK10 • A transmitter, e.g. Liquiline CM44x Optional: • RM junction box for cable extension • When using the assembly CCA250: additional sensor(s), e.g. pH sensor CPS71D a0007341 Measuring system 1 2 3 4 5 6 7 2 Liquiline CM44x transmitter with weather protection cover Power supply line for transmitter CCS142D chlorine sensor Flowfit CCA250 assembly Inlet to assembly (outlet on rear, not shown in graphic) CPS71D pH sensor CYK10 measuring cable Endress+Hauser Chloromax CCS142D Input Measured variable Free chlorine: Measuring range • CCS142D-A: 0.05 to 20 mg/l Cl2 (25 °C (77 °F), pH 7.2) • CCS142D-G: 0.01 to 5 mg/l Cl2 (25 °C (77 °F), pH 7.2) Depolarization current • CCS142D-A: approx. 25 nA per mg/l Cl2 (25° C (77 °F), pH 7.2) • CCS142D-G: approx. 80 nA per mg/l Cl2 (25 °C (77 °F), pH 7.2) hypochlorous acid (HOCl) Performance characteristics Response time T90 < 2 min in applications involving mainly active chlorination Reference operating conditions 25 °C (77 °F) pH 7.2 Measured value resolution • CCS142D-A: approx. 15 μg/l Cl2 • CCS142D-G: approx. 5 μg/l Cl2 Maximum measured error 1 % of measured value Repeatability • Sensor: ± 1% • Reference method: depending on version Calibration standards do not have long-term stability. Nominal slope • CCS142D-A: -25 nA per mg/l • CCS142D-G: -80 nA per mg/l Drift < 1.5 % per month Polarization time • CCS142D-A: Commissioning: 60 min Reoperation: 30 min • CCS142D-G: Commissioning: 90 min Reoperation: 45 min Electrolyte operating time At average medium concentrations of 1 mg/l Cl • CCS142D-A: > 5 years • CCS142D-G: > 3 years Chlorine intrinsic consumption At average medium concentrations of 1 mg/l Cl and reference conditions • CCS142D-A: 25 ng Cl per hour • CCS142D-G: 100 ng Cl per hour Endress+Hauser 3 Chloromax CCS142D Installation Installation instructions Flow assembly The flow assembly CCA250 is designed for on-site installation of the sensor. In addition to the chlorine or chlorine dioxide sensor, a pH and an ORP sensor can be installed. A needle valve regulates the flow within the range of 30 to 120 l/h (7.9 to 31.7 US.gal/h). When installing the sensor, note the following: • The flow must be at least 30 l/h (7.9 US.gal/h). If the flow drops below this value or stops completely, this can be detected by an inductive proximity switch and an alarm signal plus locking of the dosage pumps can be triggered. • If the medium is fed back into a surge tank, pipeline or the like, ensure that the thus generated back pressure on the sensor does not exceed 1 bar (14.5 psi) and remains constant. • Negative pressure at the sensor, e.g. by feedback of medium to the suction side of a pump, must be avoided. For further installation instructions, see the Operating Instructions of the flow assembly. Immersion assembly Alternatively, the sensor can be installed in an immersion assembly with threaded connection NPT ¾", e.g. CYA112. Please note the following when installing the sensor: • Hold the sensor securely in position and screw the assembly handtight onto the sensor. This prevents the cables from twisting and cable rupture. • To improve the sealing effect, we recommend you wrap a thin PTFE tape around the thread for assemblies with an NPT ¾" thread. Additional installation instructions can be found in the Operating Instructions for the assembly. Environment Storage temperature Filled with electrolyte: Without electrolyte: Ingress protection IP 68 (10 m (33 ft) water column at 25 °C (77 °F) during 45 days, 1 mol/l KCl) 5 to 50 °C (41 to 122 °F) -20 to 60 °C (-4 to 140 °F) Process Process temperature 0 to 45 °C (32 to 113 °F), non-freezing Process pressure Medium in the CCA250 assembly: max. 1 bar (14.5 psi) pH range Calibration CCS142D-A: CCS142D-G: Measurement: 4 to 8 pH 4 to 8.2 pH 4 ... 9 pH Chlorine measurement possible up to pH 9 with limited accuracy. Flow in the CCA250 assembly: min. 30 l/h (8 US.gal./h) Flow rate min. 15 cm/s (0.5 ft/s) 4 Endress+Hauser Chloromax CCS142D Mechanical construction Dimensions a0007386 Dimensions Weight approx. 0.1 kg (0.22 lbs) Material Sensor shaft: Membrane: Membrane cap: Cathode: Anode: Cable length max. 100 m (330 ft), incl. cable extension PVC PTFE PBT (GF 30), PVDF Gold Silver / silver chloride Ordering information Product structure Measuring range A 0.05 to 20 mg/l (0.05 to 20 ppm) G 0.01 to 5 mg/l (0.01 to 5 ppm) Approval A Non-hazardous area Sensor head type S Thread NPT 3/4, Memosens plug-in head Cable length 8 Standard: without cable Accessories 0 None CCS142D- Endress+Hauser Complete order code 5 Chloromax CCS142D Scope of delivery The scope of delivery comprises: • 1 chlorine sensor • 1 bottle with electrolyte (50 ml) • 1 replacement cartridge with pretensioned membrane • 1 Operating Instructions in English Accessories Installation accessories Flowfit CCA250 • Flow assembly for chlorine, chlorine dioxide, pH and ORP sensors • Ordering acc. to product structure, see Technical Information TI062C/07/en Wastewater assembly Flexdip CYA112 • Modular assembly system for sensors in open basins, channels and tanks • Versions in stainless steel or PVC • Ordering acc. to product structure (Technical Information TI432C/07/en) Connection accessories CYK10 Memosens data cable • For digital sensors with Memosens technology • Ordering according to product structure, see Technical Information (TI376C/07/en) CYK81 measuring cable • Non-terminated measuring cable for extension of sensor cables of e.g. Memosens sensors, CUS31/CUS41 • 2 wires, twisted pair with shield and PVC-sheath (2 x 2 x 0.5 mm2 + shield) • Sold by the meter, order no.: 51502543 Junction box RM • For cable extension (e.g. for Memosens sensors) • 5 terminals • Cable entries: 2 x Pg 13.5 • Material: PC • Ingress protection: IP 65 • Order no.: 51500832 Measuring point identification marking Memoclip • Identification for Memosens sensors • 100 plastic clips incl. label sheets • order no. 71038228 Calibration CCM182 • Microprocessor-controlled photometer for determining chlorine and pH value • Measuring range for chlorine: 0.05 - 6 mg/l • Measuring range for pH value: 6.5 - 8.4 • Order no.: CCM182-0 Maintenance CCY14-WP • 2 replacement cartridges ready-made for CCS140/141/142D chlorine and CCS240/241 chlorine dioxide sensors • Order no. 50005255 CCY14-F • Electrolyte for CCS140 / CCS141 / CCS142D chlorine sensors; 50 ml • Order no. 50005256 Polishing sheets COY31-PF • 10 pieces for cleaning of the gold cathode • For oxygen and chlorine sensors • Order no. 51506973 Service kit CCS14x • For chlorine sensors CCS140/CCS141/CCS142D • 2 replacement cartridges, filling electrolyte 50 ml, polishing sheets • Order no. 71076921 6 Endress+Hauser Chloromax CCS142D System solutions Compact measuring station CCE10/CCE11 • Panel mounted ready for connection for holding one or three transmitters, with flow assembly CCA250-A1 • Ordering acc. to product structure, s. Technical Information TI440C/07/EN Endress+Hauser 7 Instruments International Endress+Hauser Instruments International AG Kaegenstrasse 2 4153 Reinach Switzerland Tel.+41 61 715 81 00 Fax+41 61 715 25 00 www.endress.com [email protected] TI419C/07/EN/01.11 71128490 FM9 Technical Information CCS140 and CCS141 Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly Application Oxidising agents such as chlorine or anorganic chlorine compounds are used for disinfection of water. Their dosing must be carefully controlled to suit the application. Too low a concentration makes the degree of disinfection questionable. Too high a concentration can result in corrosion effects, impairment of taste or skin irritation. The CCS140 and CCS141 chlorine sensors are applied for measurement of free active chlorine in the following fields: • Drinking water treatment • Pool water treatment • Industrial water treatment Your benefits • Minimum flow rate for installation in the CCA250 flow assembly: 30 l/h • Measurement almost independent of flow rate in the range above 30 l/h • No zero point calibration necessary. This means complicated installation of an active carbon filter, as in open chlorine sensors, is not necessary. • Measured values are not affected by conductivity fluctuation. • The CCS140 sensor is ready for measurement after a polarisation time of approx. 30 ... 60 minutes. The CCS141 sensor requires 45 ... 90 min. • Easy membrane replacement thanks to ready-made membrane head • Recalibration intervals approx. 1 ... 4 months under constant operating conditions • Back pressure up to 1 bar / 14.5 psi allowed at the outlet TI058C/07/en/02.05 50028816 CCS140 / CCS141 Function and system design Measuring principle The concentration of free chlorine is determined according to the amperometric measuring principle. The hypochlorous acid (HOCl) contained in the medium diffuses through the sensor membrane and is reduced to chloride ions (Cl-) on the gold cathode. On the silve anode, silver is oxidised to silver chloride. The electron release of the gold cathode and electron acceptance on the silver anode result in a current flow which is proportional to the free chlorine concentration in the medium under constant conditions. The concentration of hypochlorous acid in the medium depends on the pH value. This dependence can be compensated by measuring the pH value in the flow assembly. The transmitter transforms the current signal into the measuring unit concentration in mg/l. Function The membrane-capped CCS140 / CCS141 sensors consist of a cathode serving as the working electrode and an anode acting as the counter electrode. These electrodes are immersed in an electrolyte. Electrodes and electrolyte are separated from the medium by a membrane. The membrane prevents the loss of electrolyte and the penetration of contaminants. The CCS140 and CCS141 sensors are used for measurement of free chlorine. To calibrate the measuring system, determine the content of free chlorine using the DPD method. You need a photometer with the pertaining reagents. The determined value is the calibration value for the transmitter. Measuring system A complete measuring system comprises at least: • Chlorine sensor • Liquisys M CCM223/253 transmitter • Special measuring cable • Flow assembly • Reference measuring instrument for determination of free chlorine according to the DPD method 8 9 4 5 0.42 mg/l 25.0 ¡C REL1 ALARM CAL REL REL2 REL1 E 6 REL2 7 3 2 1 a0001691 Measuring system in the flow mode (example) 1 2 3 4 5 2 CCA250 flow assembly Medium inlet Inductive proximity switch for flow monitoring Mounting place for pH/redox sensors Chlorine sensor 6 7 8 9 Medium outlet Sampling tap Fixed measuring cable Transmitter Endress+Hauser CCS140 / CCS141 Input Measured variable Free chlorine: Measuring range CCS140 (for industrial water, pool water): 0.05 ... 20 mg Cl2/l (25 °C / 77 °F, pH 7.2) CCS141 (for drinking water applications): 0.01 ... 5 mg Cl2/l (25 °C / 77 °F, pH 7.2) Depolarisation current CCS140: CCS141: hypochlorous acid (HOCl) approx. 25 nA per mg Cl2/l (25° C / 77 °F, pH 7.2) approx. 80 nA per mg Cl2/l (25 °C / 77 °F, pH 7.2) Performance characteristics Response time T90 < 2 min T99 < 5 min in applications involving mainly active chlorination Polarisation time CCS140: First polarisation: Repolarisation: CCS141: First polarisation: Repolarisation: Drift < 1.5 % per month Electrolyte service life typically 12 months 60 min 30 min 90 min 45 min Installation Installation instructions The flow assembly CCA250 is designed for on-site installation of the sensor. In addition to the chlorine or chlorine dioxide sensor, a pH and redox sensor can be installed. A needle valve regulates the flow within the range of 30 ... 120 l/h (7.92 ... 31.68 US.gal/h). When installing the sensor, note the following: • The flow must be at least 30 l/h. If the flow drops below this value or stops completely, this can be detected by an inductive proximity switch and an alarm signal plus locking of the dosage pumps can be triggered. • If the medium is fed back into a surge tank, pipeline or the like, ensure that the thus generated back pressure on the sensor does not exceed 1 bar (14.5 psi) and remains constant. • Negative pressure at the sensor, e.g. by feedback of medium to the suction side of a pump, must be avoided. For further installation instructions, see the operating instructions of the flow assembly. Endress+Hauser 3 CCS140 / CCS141 Environment Storage temperature Filled with electrolyte: Without electrolyte: Ingress protection IP 68 (up to the mounting collar Ø 36 mm / 1.42") 5 ... 50 °C / 41 ... 122 °F -20 ... 60 °C / -4 ... 140 °F Process Temperature range CCS140: CCS141: 10 ... 45 °C / 50 ... 113 °F 2 ... 45 °C / 36 ... 113 °F pH range CCS140: CCS141: 4 ... 8 pH 4 ... 8.2 pH Pressure Medium in the CCA250 assembly: max. 1 bar (14.5 psi) Flow in the CCA250 assembly: min. 30 l/h / 7.92 US.gal./h Flow velocity min. 15 cm/s / 0.5 ft/s Mechanical construction 160 / 6.30 88 / 3.46 74 / 2.91 Ø12 / 0.47 6.5 / 0.26 Dimensions Ø 25/0.98 Ø 29/1.14 Ø 36/1.42 a0002401-en Dimensions 4 Endress+Hauser CCS140 / CCS141 Weight approx. 0.5 kg / 1.1 lb. Material Sensor shaft: Membrane: Membrane cap: Cathode: Anode: Cable connection Fixed cable (3 m / 9.84 ft), four cores, double-screened, low noise Cable length max. 30 m / 98.43 ft (cable extension included) Temperature sensor NTC, 10 kΩ at 25 °C / 77 °F PVC PTFE PBT (GF 30), PVDF Gold Silver / silver chloride Ordering information CCS140 sensor Version A without temperature sensor N with NTC temperature sensor CCS140- CCS141 sensor Version N with NTC temperature sensor CCS141- Scope of delivery Endress+Hauser complete order code complete order code The scope of delivery comprises: • 1 chlorine sensor • 1 bottle filled with electrolyte (50 ml) plus nozzle • 1 membrane cap for protection and storage • 1 replacement cartridge with pretensioned membrane • Operating Instructions, English 5 CCS140 / CCS141 Accessories Installation accessories • Flow assembly CCA250 for chlorine, chlorine dioxide, pH and redox; Ordering acc. to product structure, see Technical Information (TI 062C/07/en) • Compact chlorine system CCE1 Factory-assembled and wired panel for transmitter with flow assembly CCA250-A1; see also Technical Information TI 014C/07/en Connection accessories • Junction box VBC Metallic junction box for cable extension, dimensions (W x D x H): 125 x 80 x 54 mm / 4.92 x 3.15 x 2.13 inches Order no. 50005181 • CMK special measuring cable for cable extension between junction box and transmitter, non terminated, sold by the metre Order no. 50005374 Transmitter • Liquisys M CCM223/253 Transmitter for chlorine, field or panel-mounted housing, Hart® or PROFIBUS available, Ordering acc. to product structure, see Technical Information (TI 214C/07/en) Maintenance /calibration • Photometer CCM182; microprocessor-controlled photometer for chlorine, pH value, cyanuric acid; Chlorine measuring range: 0.05 - 6 mg/l pH measuring range: 6.5 - 8.4 • CCY14-F Electrolyte for CCS140 / CCS141 chlorine sensors, 50 ml Order no. 50005256 • CCY14-WP 2 replacement cartridges ready-made for CCS140/141/240/241 chlorine and chlorine dioxide sensors Order no. 50005255 6 Endress+Hauser CCS140 / CCS141 Endress+Hauser 7 International Head Quarters Endress+Hauser GmbH+Co. KG Instruments International Colmarer Str. 6 79576 Weil am Rhein Deutschland Tel. +49 76 21 9 75 02 Fax +49 76 21 9 75 34 5 www.endress.com [email protected] TI058C/07/en/02.05 50028816 Printed in Germany / FM+SGML 6.0 / DT Technical Information CCS240 and CCS241 Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly Application Chlorine dioxide is used for disinfection of water. Its dosing must be carefully controlled to suit the application. Too low a concentration makes the degree of disinfection questionable. Too high a concentration can result in corrosion effects, impairment of taste or skin irritation. The CCS240 and CCS241 sensors are applied for measurement of chlorine dioxide in the following fields: • Drinking water treatment • Pool water treatment • Industrial water treatment Your benefits • Minimum flow rate for installation in the CCA250 flow assembly: 30 l/h • Measurement almost independent of flow rate in the range above 30 l/h • No zero point calibration necessary. This means complicated installation of an active carbon filter, as in open chlorine dioxide sensors, is not necessary. • Measured values are not affected by conductivity fluctuation. • The CCS240 sensor is ready for measurement after a polarisation time of approx. 10 ... 30 minutes. The CCS241 sensor requires 45 ... 90 min. • Easy membrane replacement thanks to ready-made membrane head • Recalibration intervals approx. 1 ... 4 months under constant operating conditions • Back pressure up to 1 bar / 14.5 psi allowed at the outlet TI114C/07/en/02.05 50068514 CCS240 / CCS241 Function and system design Measuring principle The concentration of chlorine dioxide is determined according to the amperometric measuring principle. The chlorine dioxide (ClO2) contained in the medium diffuses through the sensor membrane and is reduced to chloride ions (Cl-) on the gold cathode. On the silve anode, silver is oxidised to silver chloride. The electron release of the gold cathode and electron acceptance on the silver anode result in a current flow which is proportional to the chlorine dioxide concentration in the medium. This process takes place within a wide pH and temperature range. The transmitter transforms the current signal into the measuring unit concentration in mg/l. Function The membrane-capped CCS240 / CCS241 sensors consist of a cathode serving as the working electrode and an anode acting as the counter electrode. These electrodes are immersed in an electrolyte. Electrodes and electrolyte are separated from the medium by a membrane. The membrane prevents the loss of electrolyte and the penetration of contaminants. The CCS240 and CCS241 sensors are used for measurement of chlorine dioxide. To calibrate the measuring system, determine the content of chlorine dioxide using the DPD method. You need a photometer with the pertaining reagents. The determined value is the calibration value for the transmitter. Measuring system A complete measuring system comprises at least: • Chlorine dioxide sensor • Liquisys M CCM223/253 transmitter • Special measuring cable • Flow assembly • Reference measuring instrument for determination of chlorine dioxide according to the DPD method 8 9 4 5 0.42 mg/l 25.0 ¡C REL1 ALARM CAL REL REL2 REL1 E 6 REL2 7 3 2 1 a0001691 Measuring system in the flow mode (example) 1 2 3 4 5 2 CCA250 flow assembly Medium inlet Inductive proximity switch for flow monitoring Mounting place for pH/redox sensors Chlorine dioxide sensor 6 7 8 9 Medium outlet Sampling tap Fixed measuring cable Transmitter Endress+Hauser CCS240 / CCS241 Input Measured variable Chlorine dioxide (ClO2) Measuring range CCS240 (for industrial water, pool water): 0.05 ... 20 mg ClO2/l CCS241 (for drinking water applications): 0.01 ... 5 mg ClO2/l Performance characteristics Response time T90 < 2 min T99 < 5 min Polarisation time CCS240: First polarisation: Repolarisation: CCS241: First polarisation: Repolarisation: Drift < 1.5 % per month Electrolyte service life typically 12 months 30 min 10 min 90 min 45 min Installation Installation instructions The flow assembly CCA250 is designed for on-site installation of the sensor. In addition to the chlorine or chlorine dioxide sensor, a pH and redox sensor can be installed. A needle valve regulates the flow within the range of 30 ... 120 l/h (7.92 ... 31.68 US.gal/h). When installing the sensor, note the following: • The flow must be at least 30 l/h. If the flow drops below this value or stops completely, this can be detected by an inductive proximity switch and an alarm signal plus locking of the dosage pumps can be triggered. • If the medium is fed back into a surge tank, pipeline or the like, ensure that the thus generated back pressure on the sensor does not exceed 1 bar (14.5 psi) and remains constant. • Negative pressure at the sensor, e.g. by feedback of medium to the suction side of a pump, must be avoided. For further installation instructions, see the operating instructions of the flow assembly. Endress+Hauser 3 CCS240 / CCS241 Environment Storage temperature Filled with electrolyte: Without electrolyte: Ingress protection IP 68 (up to the mounting collar Ø 36 mm / 1.42") 5 ... 50 °C / 41 ... 122 °F -20 ... 60 °C / -4 ... 140 °F Process Temperature range 2 ... 45 °C / 36 ... 113 °F pH range in stability range of ClO2 Pressure Medium in the CCA250 assembly: max. 1 bar (14.5 psi) Flow in the CCA250 assembly: min. 30 l/h / 7.92 US.gal./h Flow velocity min. 15 cm/s / 0.5 ft/s Mechanical construction 160 / 6.30 88 / 3.46 74 / 2.91 Ø12 / 0.47 6.5 / 0.26 Dimensions Ø 25/0.98 Ø 29/1.14 Ø 36/1.42 a0002401-en Dimensions 4 Endress+Hauser CCS240 / CCS241 Weight approx. 0.5 kg / 1.1 lb. Material Sensor shaft: Membrane: Membrane cap: Cathode: Anode: Cable connection Fixed cable (3 m / 9.84 ft), four cores, double-screened, low noise Cable length max. 30 m / 98.43 ft (cable extension included) Temperature sensor NTC, 10 kΩ at 25 °C / 77 °F PVC PTFE PBT (GF 30), PVDF Gold Silver / silver chloride Ordering information CCS240 sensor Version N with NTC temperature sensor CCS240- CCS241 sensor Version N with NTC temperature sensor CCS241- Scope of delivery Endress+Hauser complete order code complete order code The scope of delivery comprises: • 1 chlorine dioxide sensor • 1 bottle filled with electrolyte (50 ml) plus nozzle • 1 membrane cap for protection and storage • 1 replacement cartridge with pretensioned membrane • Operating Instructions, English 5 CCS240 / CCS241 Accessories Installation accessories • Flow assembly CCA250 for chlorine, chlorine dioxide, pH and redox; Ordering acc. to product structure, see Technical Information (TI 062C/07/en) • Compact chlorine system CCE1 Factory-assembled and wired panel for transmitter with flow assembly CCA250-A1; see also Technical Information TI 014C/07/en Connection accessories • Junction box VBC Metallic junction box for cable extension, dimensions (W x D x H): 125 x 80 x 54 mm / 4.92 x 3.15 x 2.13 inches Order no. 50005181 • CMK special measuring cable for cable extension between junction box and transmitter, non terminated, sold by the metre Order no. 50005374 Transmitter • Liquisys M CCM223/253 Transmitter for chlorine, field or panel-mounted housing, Hart® or PROFIBUS available, Ordering acc. to product structure, see Technical Information (TI 214C/07/en) Maintenance /calibration • Photometer CCM182; microprocessor-controlled photometer for chlorine, pH value, cyanuric acid; Chlorine measuring range: 0.05 - 6 mg/l pH measuring range: 6.5 - 8.4 • CCY24-F Electrolyte for CCS240 / CCS241 chlorine dioxide sensors, 50 ml Order no. 50064294 • CCY14-WP 2 replacement cartridges ready-made for CCS140/141/240/241 chlorine and chlorine dioxide sensors Order no. 50005255 6 Endress+Hauser CCS240 / CCS241 Endress+Hauser 7 International Head Quarters Endress+Hauser GmbH+Co. KG Instruments International Colmarer Str. 6 79576 Weil am Rhein Deutschland Tel. +49 76 21 9 75 02 Fax +49 76 21 9 75 34 5 www.endress.com [email protected] TI114C/07/en/02.05 50068514 Printed in Germany / FM+SGML 6.0 / DT
© Copyright 2026 Paperzz