JD Steam There Are Some Things You Can Always Depend On... JD Steam Commercial Gas Fired Steam Boiler Electronic Ignition Base Standard Equipment: Base • Fire Door • Burner Orifice • Manifold • Main and Pilot Burner • Electronic Pilot Gas Valve • Intermittent Pilot Module • Complete Jacket Assembly • Steam Trim Package: Low Water Cut-Off Glass Gauge Set • Safety Valve • Steam Gauge • Pressure Limit • Drain Valve • • JD Series Boiler Bases are pre-assembled at the factory with burner manifold, burner orifices, gas valves and electronic ignition installed, ready for field installation of the pre-tested sections and appropriate packages. Plug ‘N Play Harness and Junction Box Individual base and junction box controls are designed for easy installation with Plug ‘n Play harnesses. The entire boiler links together in a “snap”. A color-coded factory supplied harness eliminates wiring errors. CSD1 Option JD boilers are available with a CSD1 option to comply with CSD1 standards where required by building code. The CSD1 option provides the increased number of controls and safety devices required to meet CSD1 standards. Utica JD Commercial Gas-Fired Steam Boiler Model Gross Input (1) Output (Mbh) (Mbh) Net AHRI Ratings Steam (PPF) (2) Base Size & Flue Outlet Steam Steam (Sq. Ft.) (3) (Mbh) (2) 300 (8") 400 (10") 500 (12") Chimney Vent Size (4) Connector Size Therm. Eff. I.D. x Ht. to Chimney (4) Comb Eff JD-300S 300 233 1.333 729 175 1 0 0 8" x 20' 8 77.5 80.4 JD-400S 400 310 1.333 971 233 0 1 0 10" x 20' 10 77.5 80.5 JD-500S 500 388 1.333 1213 291 0 0 1 12" x 20' 12 77.5 80.5 JD-600S 600 465 1.333 1454 349 2 0 0 12" x 20' 12 77.5 80.4 JD-700S 700 543 1.333 1696 407 1 1 0 12" x 20' 12 77.5 80.5 JD-800S 800 620 1.333 1938 465 0 2 0 14" x 20' 14 77.5 80.5 JD-900S 900 698 1.333 2183 524 0 1 1 14" x 20' 14 77.5 80.5 JD-1000S 1000 775 1.333 2421 581 0 0 2 14" x 20' 14 77.5 80.5 JD-1100S 1100 853 1.333 2667 640 1 2 0 16" x 20' 16 77.5 80.5 JD-1200S 1200 930 1.333 2908 698 0 3 0 16" x 20' 16 77.5 80.5 JD-1300S 1300 1008 1.333 3150 756 1 0 2 16" x 20' 16 77.5 80.5 JD-1400S 1400 1085 1.333 3392 814 0 1 2 18" x 20' 18 77.5 80.5 JD-1500S 1500 1163 1.333 3633 872 0 0 3 18" x 20' 18 77.5 80.5 JD-1600S 1600 1240 1.333 3875 930 0 4 0 18" x 20' 18 77.5 80.5 JD-1700S 1700 1318 1.327 4138 993 1 1 2 18" x 20' 18 77.5 80.5 JD-1800S 1800 1395 1.319 4408 1058 0 2 2 20" x 20' 20 77.5 80.5 JD-1900S 1900 1473 1.313 4675 1122 0 1 3 20" x 20' 20 77.5 80.5 JD-2000S 2000 1550 1.307 4942 1186 0 0 4 20" x 20' 20 77.5 80.5 JD-2100S 2100 1628 1.301 5213 1251 2 0 3 20" x 20' 20 77.5 80.5 JD-2200S 2200 1705 1.296 5483 1316 0 3 2 22" x 20' 22 77.5 80.5 JD-2300S 2300 1783 1.292 5750 1380 0 2 3 22" x 20' 22 77.5 80.5 JD-2400S 2400 1860 1.290 6008 1442 0 1 4 22" x 20' 22 77.5 80.5 JD-2500S 2500 1938 1.288 6271 1505 0 0 5 22" x 20' 22 77.5 80.5 JD-2600S 2600 2015 1.288 6517 1564 2 0 4 22" x 20' 22 77.5 80.5 JD-2700S 2700 2093 1.288 6771 1625 1 1 4 24" x 20' 24 77.5 80.5 JD-2800S 2800 2170 1.288 7021 1685 0 2 4 24" x 20' 24 77.5 80.5 JD-2900S 2900 2248 1.288 7271 1745 0 1 5 24" x 20' 24 77.5 80.5 JD-3000S 3000 2325 1.288 7521 1805 0 0 6 24" x 20' 24 77.5 80.5 Right & Left End Tappings Data D A 1. Ratings are at sea level to 2,000 feet. For altitudes above 2,000 feet, reduce all ratings 4% for each 1,000 feet above sea level. 2. Net steam ratings based on piping and pickup allowance of 1.333 (300-1600), 1.327 (1700), 1.319 (1800), 1.313 (1900), 1.307 (2000), 1.301 (2100), 1.296 (2200), 1.292 (2300), 1.290 (2400), and 1.288 (2500-3000). Contact Technical Support before selecting boiler for installations having unusual piping and pick-up factors, such as intermittent system operations, Supply and Return extensive piping systems, etc. 3. Ratings in square feet are computed at 240 Btuh/square foot for steam boilers. Primary LWCO 4. Chimney sizes shown are one option based on a typical venting system as shown in Figure 6 of the Installation Manual, and and Gauge sized according to the National Fuel Gas Code, assuming Type B double wall vent and vent connectors, other venting system Glass set designs are acceptable as shown on Flue Connection And Venting section of the installation manual. For further chimney Drain, Left End design and sizing information, consult the National Fuel Gas Code, ANSI Z223.1/NFPA 54-latest revision, or ASHRAE HVAC Systems and Equipment Handbook, Chimney, Gas Vent, and Fireplace Systems, or the Standard for Chimneys, Fireplaces, Drain, Right End Vents, and Solid Fuel Burning Appliances. NFPA 211. Follow standard engineering practice. Opening Size A 4” B 1/2” C 3/4” C 3/4” D 1/2” Plugged E 1” Accessories *F 1” Safety Valve G 3/4” Plugged or Electronic (Probe Type) LWCO F B G B A E C Steam *If opening F is to be used for something other than the Safety Valve or Pressure Relief Valve, or the Safety/Relief Valve is larger than 1”, the Safety/Relief Valve must be installed in the Header Piping as near to the boiler as possible. Contractor Assistance: 800.325.5479 Certifications All ratings and specifications subject to change. P.O. Box 4729 Utica, New York 13504 tel: 315.797.1310 • fax: 315.797.3762 www.uticaboilers.com PN 240009442 Rev. 6/12
© Copyright 2026 Paperzz