GHM-Messtechnik GmbH • Location Martens Kiebitzhörn 18 • D-22885 Barsbüttel / Germany +49-(0)40-670 73-0 • Fax +49-(0)40-670 73-288 [email protected] • www.ghm-messtechnik.de Isolating-Signal-Converter TV 501-Ex with intrinsically safe outputs Features M Universal inputs 0/4 ... 20 mA and 0/2 ... 10 V M Intrinsically safe outputs Ex II (1) G [Ex ia Ga] IIC Ex II (1) D [Ex ia Da] IIIC for 0/4 ... 20 mA simultaneous 0/2 ... 10 V M Supply voltage 10 ... 30 V AC/DC or 85 ... 253 V AC/110 ... 125 V DC M Full 3-port isolation M Power on LED M 22.5mm case for TS35 DIN rail mounting General information Isolating signal converter TV501 can be used to isolate and convert 0/4 ... 20 mA and 0/2 ... 10 V signals to the hazardous area. The universal design of the in- and outputs and the wide range of supply voltage limits the devices into 2 models. Short information Current output Ex-i Max. burden ≤ 1 kΩ. Useful to drive I/P Transmitters, proportional valves and loop powered panelmeter installed in hazardous areas. The connected devices need to be certified depending on operation-places. Multi-range Inputs and outputs are configurable between 0/4 ... 20 mA and 0/2 ... 10 V by DIP-switches at the front panel. ... professional Instruments “MADE IN GERMANY“ . . . p r o f e s s i o n a l I n s t r u m e n t s “ M A D E I N G E R -M1A- N Y “ GHM-Messtechnik GmbH • Location Martens Kiebitzhörn 18 • D-22885 Barsbüttel / Germany +49-(0)40-670 73-0 • Fax +49-(0)40-670 73-288 [email protected] • www.ghm-messtechnik.de Technical data Power supply Supply voltage : : : : : 85 ... 253 V AC/110 ... 125 V DC; 10 ... 30 V AC/DC 40 ... 400 Hz Power consumption < 3.5 VA Working temperature -10 ... 55 °C (14 ... 131 °F) Rated voltage 253 V AC or 125 V DC (Um) acc. to EN 60079-0 250 V AC acc. to EN60664-1, degree of pollution 2, overvoltage category III, between input/output/supply voltage Test voltage : 3 kV AC between input/output/supply voltage -conformity : ATEX directive 94/9/EG, EMC directive 2004/108/EG, Generic standards: (Certificate TV501ATEX.004) EN 60079-0:2013, EN 60079-11:2012, EN 61326-1:2004-05 Measuring Input Current input Voltage input Zero point Span Rated voltage : : : : : Explosion protection Certification Protection Max. output voltage U0 Max. output current I0 Max. power consumption P0 0/4 ... 20 mA switch selectable Ri = 25 Ohm; overload max. 100 mA 0/2 ... 10 V switch selectable, Ri approx. 40 kOhm; overload max. 100 V adjustable ±5 % adjustable ±5 % 253 V AC or 125 V DC (Um) acc. to EN 60079-0 Permissible short circuit current of the connected apparatus max. 2 A : : : : : TÜV 97 ATEX 1164 Ex II (1) G [Ex ia Ga] IIC, Ex II (1) D [Ex ia Da] IIIC 31.5 V 95 mA 730 mW (curve linear) Area classification Max. ext. capacity C0 Max. ext. inductivity L0 Internal capacity Ci Internal inductivity Li Ex ia/IIB : 280 nF : 1 mH : 10.4 nF : nigligibly small ia/IIC 48 nF 0.5 mH The intrinsically safe circuits are galvanically separated from the non-intrinsically safe circuits up to a peak crest value of the voltage of 375 V. Output Current output : 0/4 ... 20 mA switch selectable burden ≤320 Ω (TV501Ex-...-10) burden ≤1 kΩ (TV501Ex-...-20) Voltage output : 0/2 ... 10 V switch selectable, load max. 15 mA short-circuit proof (Simultaneous to the current output max. 5 mA) : <20 ms Rise time (T90) Accuracy : ≤ 0.3 % Temperature coefficient : ≤ 0.01 %/K Behavior of current output on sensor errors at configuration 4 ... 20 mA (for input and output) Cl. 8, 9 shorted Broken Overdriven (max. 100 mA) < 2.5 mA < 2.5 mA limit value 23 ... 25 mA Case Type Weight Protection Connection Mounting area : : : : : standard case of polycarbonate 8020 UL94 V-1 approx. 200 g case IP30, terminals IP20 finger safe acc. to German BGV A3 screw terminals with pressure plate, max. 2.5 mm², wire mounting in dry, clean and well monitored area -2- Front panel controls DIPswitches Input Output Power-On LED Connection diagram 0 ... 20 mA 0 ... 10 V S1 OFF S2 OFF 4 ... 20 mA 2 ... 10 V S1 ON S2 ON Connection to actuators with voltage input with current input Connection to the hazardous area Outputs Outputs Inputs PA: Protective earth terminal (PE) acc. to VDE0100 part 540 Supply voltage Dimension and controls (small side) Caution! Mounting of multiple units without distance is only permitted in horizontal orientation. Adjust Zero point Span TS35 DIN rail mounting acc. to DIN 46277 and DIN EN 60715 . . . p r o f e s s i o n a l I n s t r u m e n t s “ M A D E I N G E R M A N Y- “3 - GHM-Messtechnik GmbH • Location Martens Kiebitzhörn 18 • D-22885 Barsbüttel / Germany +49-(0)40-670 73-0 • Fax +49-(0)40-670 73-288 [email protected] • www.ghm-messtechnik.de Ordering code TV501-Ex-ia- 1. 1. 2. 3. - 2. - 3. Measuring range 10 Inputs 0/4 ... 20 mA and 0/2 ... 10 V DC Outputs 0/4 ... 20 mA burden max. 320 Ω 0/2 ... 10 V simultaneously, max. 15 mA 20 Inputs 0/4 ... 20 mA and 0/2 ... 10 V DC Outputs 0/4 ... 20 mA burden max. 1000 Ω Supply voltage 0 85 ... 253 V AC/110 ... 125 V DC 10 ... 30 V AC/DC 5 Options 00 no option 14/05-04 ... professional Instruments “MADE IN GERMANY“ . . . p r o f e s s i o n a l I n s t r u m e n t s “ M A D E I N G E R -M4A- N Y “ 01/05-01
© Copyright 2026 Paperzz