super spec hp - Benjamin Moore

SUPER SPEC HP
®
CONCRETE CRACK REPAIR
KIT P72
Features
•
•
•
•
•
•
Extremely Low VOC'S
Odorless
Excellent adhesion
Easy to trowel
Non-flammable
Excellent abrasion
resistance
General Description
• Superior bond strength
• Rapid setting — foot
traffic in 8 hours or less
• 98% solids
• Can be feather-edged
• Non-shrinking
This 98% solids epoxy co-polymer matrix is formulated for repair
and patching of concrete floors. It is a rapid setting compound
which develops extremely high initial strength and is ready for foot
traffic in 5 to 8 hours.
Recommended For
Limitations
• Proper curing requires 50° F (10° C) minimum application
temperature and relative humidity below 70%
• Should not be applied over damp surfaces
• Will not withstand constant temperatures over 175° F (80 °C).
Industrial plant floors, industrial plant walls, loading docks,
sidewalks, driveways, ramps
Labor Saving Benefits:
Product Information
Technical Data◊
• Excellent abrasion resistance for use in high abuse or high traffic
areas.
• 98% solids provides no shrinkage
Colors: —Standard:
(concrete gray)
Note: This is a 3-part product. All three components are required for
application. P72-A, P72-B, P72-C
Vehicle Type
Pigment Type
Volume Solids (mixed as
recommended)
Coverage per Gallon at
Recommended Film Thickness
Recommended
– Wet
Film Thickness
– Dry
Modified Amine Epoxy
Inerts
98% mixed
25 Sq. Ft.
1/8 inch
1/8 inch
Depending on surface texture and porosity. Be sure to estimate
the right amount of paint for the job. This will ensure color
uniformity and minimize the disposal of excess paint.
—Tints:
Dry Time @ 77° F – To Touch
(25° C) @ 50% RH – To Recoat*
Not Available
3 Hours
8 Hours
*If top coat is not applied within 72 hours abrade the surface to
ensure proper inter-coat adhesion. High humidity and cool
temperatures will result in longer dry, recoat and service times.
—Special Colors:
Contact your Benjamin Moore & Co representative.
Dries By
Dry Heat Resistance Intermittent
Viscosity (mixed as
recommended)
Flash Point
Gloss / Sheen
Surface Temperature – Min.
at Application
– Max
Certification:
VOC compliant in all regulated areas.
Chemical Cure
175° F
Heavy
> 200° F
N/A
50° F
85° F
Surface must be dry and at least 5° above the dew point.
Technical Assistance:
®
Available through your local authorized independent Benjamin Moore
retailer. For the location of the retailer nearest you, call 1-800-826-2623, see
www.benjaminmoore.com, or consult your local Yellow Pages.
Thin With
Clean Up Thinner
Mixed Ratio (by volume)
N/A
P95
2 minutes for A + B
1 minute for A & B + C
N/A
30 Minutes
Induction time @ 77° F
Pot Life @ 77° F
Weight Per Gallon (mixed as
recommended)
– Min.
Storage Temperature
– Max
Volatile Organic Compounds (VOC)
19 lbs
40° F
90° F
20 Grams / Liter*
.17 LBS / Gallon*
* Catalyzed
Benjamin Moore & Co., 101 Paragon Drive, Montvale, NJ 07645 Tel: (201) 573-9600 Fax: (201) 573-9046 www.benjaminmoore.com M72 P72 US 033011
Super Spec HP® Concrete Crack Repair Kit P72
Surface Preparation
Surface preparation is the most critical portion of any successful
flooring system application. All substrates must be properly
prepared using the following information.
Concrete must cure for a minimum of 30 days before applying floor
systems. Slabs on ground or grade must have an efficient vapor
barrier to prevent moisture vapor transmission. Test for moisture
following ASTM D-4253 Plastic Sheet Test. Proper jointing will
minimize cracking which could transmit through the coating
system. Expansion joints are treated after the coating is applied.
All unsound concrete must be repaired or replaced prior to coating
application. Cracks should be repaired prior to coating application.
®
Remove all oil, grease, or fats using Benjamin Moore Oil &
Grease Emulsifier (P83), following product directions. Remove all
curing compounds, hardeners, sealers, and laitances using
portable shot blast cleaning systems.
Epoxy floor coatings ideally bond to concrete that has a rough,
sandpaper finish, achieved either by mechanical methods or by
acid etching. Acid etching works best in preparing surfaces for thin
®
film coating systems. Use Benjamin Moore
Concrete
Pretreatment & Etch (P85) according to product instructions.
Vacuum entire floor using a heavy duty wet/dry vacuum to remove
all water or laitance removal residue from the pores or voids of the
floor.
Ecological restrictions involved with waste removal could prohibit
the use of acids or other chemical methods. Remove existing
coatings, curing compounds, hardeners, sealer, laitance, and other
foreign matter by using mechanical methods such as sand
blasting, vacuum blasting, scarifiers, Roto Peen, or vacuum shot
blasting. This operation should expose a clean, sound, porous,
roughened surface that maximizes coating adhesion.
WARNING! If you scrape, sand or remove old paint, you may
release lead dust. LEAD IS TOXIC. EXPOSURE TO LEAD DUST
CAN CAUSE SERIOUS ILLNESS, SUCH AS BRAIN DAMAGE,
ESPECIALLY IN CHILDREN. PREGNANT WOMEN SHOULD
ALSO AVOID EXPOSURE. Wear a NIOSH approved respirator to
control lead exposure. Carefully clean up with a HEPA vacuum
and a wet mop. Before you start, find out how to protect yourself
and your family by contacting the National Lead Information
Hotline at 1-800-424-LEAD or log on to www.epa.gov/lead.
Mixing Instructions
Remove all three components from the pail. Set the Part C
aggregate bag aside. Pour the entire contents of the Part A and
Part B containers into the now empty pail.
®
Caution: Do not change the mixing ratio of Super Spec HP
Concrete Crack Repair Kit (P72). Blend thoroughly for 2 minutes
using a spiral mixing blade in a variable speed (400–600 rpm)
electric drill, or use a Jiffy Mixer. Place the spiral mixing blade at
the bottom of the material before turning on the mixer to avoid
inducing air into the material while mixing, which will lead to
greater porosity in the finished mortar. Gently move the running
mixer toward the surface, but do not remove while spinning. Slowly
add the Part C aggregate to the liquid mixture in the pail. Blend
until all the aggregate is thoroughly mixed, covered, or saturated
with the liquid mixture (1 minute).
Application
Apply the epoxy/aggregate mixture immediately after mixing by
pouring the material onto the floor and spreading with a trowel
until the desired texture and thickness are achieved. When
repairing cracks or spalled concrete, apply material flush with the
surrounding floor. Excess material around a repair, once cured,
may be ground smooth with a diamond grinder or grinding stone.
For best results: Apply a test patch first to ensure compatibility.
Do not use when humidity exceeds 70% indoors. For interior use
only. If product has been frozen, allow to completely warm up to
70° F before using. A vapor barrier must be used beneath the
substrate to be coated to prevent loss of adhesion. For best
®
adhesion, prime first with Super Spec HP Fast Dry Epoxy Floor
®
Sealer/Finish (P41) or Super Spec HP Concrete Crack Repair
Kit (P72) A & B only. If priming with P72 A & B, the repair mortar
should be applied while primer is still “wet.”.
Thinning/Cleanup
DO NOT THIN.
Clean all equipment immediately after use with Super Spec HP
Epoxy Thinner (P95).
USE COMPLETELY OR DISPOSE OF PROPERLY. This product
contains components which may cause adverse affects to the
environment if handled improperly. Dry empty containers may be
recycled in a can recycling program. Local disposal
requirements vary; consult your sanitation department or
state-designated environmental agency on disposal options.
Environmental, Health & Safety Information
Contains: Epoxy Resin, P-tert-Butylphenol, Nonyl Phenol,
Benzene-1,3-Dimethamine
CAUSES SEVERE EYE AND SKIN BURNS. HARMFUL OR
FATAL IF SWALLOWED. SEVERE ASPIRATION HAZARD.
HARMFUL IF ABSORBED THROUGH SKIN. VAPORS MAY
AFFECT CENTRAL NERVOUS SYSTEM CAUSING DIZZINESS,
HEADACHES AND NAUSEA, MAY CAUSE ALLERGIC SKIN
REACTION
IMPORTANT: Designed to be mixed with other components.
Mixture will have hazards of both components. Before opening
packages, read all warning labels. Follow all precautions.
NOTICE: Repeated or prolonged exposure to organic solvents
may lead to permanent brain and nervous system damage.
Intentional misuse by deliberately concentrating and inhaling
vapors may be harmful or fatal.
Use only with adequate ventilation. Do not breathe vapors or
sanding dust. Avoid contact with eyes, skin and clothing. Wear
chemical resistant goggles and face shield, chemical resistant
gloves and protective clothing during application and cleanup. Do
not wear contact lenses. Open doors, windows or use other
means to ensure fresh air entry during application and cleanup. If
you experience eye watering, headache or dizziness or if air
monitoring demonstrates vapor levels are above applicable limits,
wear an appropriate, NIOSH approved, properly fitted respirator
during use and cleanup. Follow respirator manufacturer’s
directions for respirator use. Do not permit anyone without
protection in the painting area. Wash thoroughly after handling.
Close container after each use.
FIRST AID: If affected by inhalation of vapors or sanding dust,
remove to fresh air. In cases of eye contact, flush immediately
with copious amounts of water holding eyelids open for at least 15
minutes and call a physician immediately; for skin, remove
contaminated clothing and flush affected area with water for at
least 15 minutes. In case of ingestion, DO NOT INDUCE
VOMITING, get medical help immediately.
IN CASE OF: FIRE — Use foam CO2, dry chemical or water fog.
SPILL —Absorb with inert material and dispose of as specified
under “Clean Up”.
KEEP OUT OF REACH OF CHILDREN
Refer to Material Safety Data Sheet for
additional health and safety information.
Benjamin Moore & Co., 101 Paragon Drive, Montvale, NJ 07645 Tel: (201) 573-9600 Fax: (201) 573-9046 www.benjaminmoore.com M72 P72 US 033011
Benjamin Moore, Super Spec HP, and the triangle “M” symbol
are registered trademarks of Benjamin Moore & Co., Limited.
®
© 2008, 2011 Benjamin Moore & Co., Limited