SUPER SPEC HP ® CONCRETE CRACK REPAIR KIT P72 Features • • • • • • Extremely Low VOC'S Odorless Excellent adhesion Easy to trowel Non-flammable Excellent abrasion resistance General Description • Superior bond strength • Rapid setting — foot traffic in 8 hours or less • 98% solids • Can be feather-edged • Non-shrinking This 98% solids epoxy co-polymer matrix is formulated for repair and patching of concrete floors. It is a rapid setting compound which develops extremely high initial strength and is ready for foot traffic in 5 to 8 hours. Recommended For Limitations • Proper curing requires 50° F (10° C) minimum application temperature and relative humidity below 70% • Should not be applied over damp surfaces • Will not withstand constant temperatures over 175° F (80 °C). Industrial plant floors, industrial plant walls, loading docks, sidewalks, driveways, ramps Labor Saving Benefits: Product Information Technical Data◊ • Excellent abrasion resistance for use in high abuse or high traffic areas. • 98% solids provides no shrinkage Colors: —Standard: (concrete gray) Note: This is a 3-part product. All three components are required for application. P72-A, P72-B, P72-C Vehicle Type Pigment Type Volume Solids (mixed as recommended) Coverage per Gallon at Recommended Film Thickness Recommended – Wet Film Thickness – Dry Modified Amine Epoxy Inerts 98% mixed 25 Sq. Ft. 1/8 inch 1/8 inch Depending on surface texture and porosity. Be sure to estimate the right amount of paint for the job. This will ensure color uniformity and minimize the disposal of excess paint. —Tints: Dry Time @ 77° F – To Touch (25° C) @ 50% RH – To Recoat* Not Available 3 Hours 8 Hours *If top coat is not applied within 72 hours abrade the surface to ensure proper inter-coat adhesion. High humidity and cool temperatures will result in longer dry, recoat and service times. —Special Colors: Contact your Benjamin Moore & Co representative. Dries By Dry Heat Resistance Intermittent Viscosity (mixed as recommended) Flash Point Gloss / Sheen Surface Temperature – Min. at Application – Max Certification: VOC compliant in all regulated areas. Chemical Cure 175° F Heavy > 200° F N/A 50° F 85° F Surface must be dry and at least 5° above the dew point. Technical Assistance: ® Available through your local authorized independent Benjamin Moore retailer. For the location of the retailer nearest you, call 1-800-826-2623, see www.benjaminmoore.com, or consult your local Yellow Pages. Thin With Clean Up Thinner Mixed Ratio (by volume) N/A P95 2 minutes for A + B 1 minute for A & B + C N/A 30 Minutes Induction time @ 77° F Pot Life @ 77° F Weight Per Gallon (mixed as recommended) – Min. Storage Temperature – Max Volatile Organic Compounds (VOC) 19 lbs 40° F 90° F 20 Grams / Liter* .17 LBS / Gallon* * Catalyzed Benjamin Moore & Co., 101 Paragon Drive, Montvale, NJ 07645 Tel: (201) 573-9600 Fax: (201) 573-9046 www.benjaminmoore.com M72 P72 US 033011 Super Spec HP® Concrete Crack Repair Kit P72 Surface Preparation Surface preparation is the most critical portion of any successful flooring system application. All substrates must be properly prepared using the following information. Concrete must cure for a minimum of 30 days before applying floor systems. Slabs on ground or grade must have an efficient vapor barrier to prevent moisture vapor transmission. Test for moisture following ASTM D-4253 Plastic Sheet Test. Proper jointing will minimize cracking which could transmit through the coating system. Expansion joints are treated after the coating is applied. All unsound concrete must be repaired or replaced prior to coating application. Cracks should be repaired prior to coating application. ® Remove all oil, grease, or fats using Benjamin Moore Oil & Grease Emulsifier (P83), following product directions. Remove all curing compounds, hardeners, sealers, and laitances using portable shot blast cleaning systems. Epoxy floor coatings ideally bond to concrete that has a rough, sandpaper finish, achieved either by mechanical methods or by acid etching. Acid etching works best in preparing surfaces for thin ® film coating systems. Use Benjamin Moore Concrete Pretreatment & Etch (P85) according to product instructions. Vacuum entire floor using a heavy duty wet/dry vacuum to remove all water or laitance removal residue from the pores or voids of the floor. Ecological restrictions involved with waste removal could prohibit the use of acids or other chemical methods. Remove existing coatings, curing compounds, hardeners, sealer, laitance, and other foreign matter by using mechanical methods such as sand blasting, vacuum blasting, scarifiers, Roto Peen, or vacuum shot blasting. This operation should expose a clean, sound, porous, roughened surface that maximizes coating adhesion. WARNING! If you scrape, sand or remove old paint, you may release lead dust. LEAD IS TOXIC. EXPOSURE TO LEAD DUST CAN CAUSE SERIOUS ILLNESS, SUCH AS BRAIN DAMAGE, ESPECIALLY IN CHILDREN. PREGNANT WOMEN SHOULD ALSO AVOID EXPOSURE. Wear a NIOSH approved respirator to control lead exposure. Carefully clean up with a HEPA vacuum and a wet mop. Before you start, find out how to protect yourself and your family by contacting the National Lead Information Hotline at 1-800-424-LEAD or log on to www.epa.gov/lead. Mixing Instructions Remove all three components from the pail. Set the Part C aggregate bag aside. Pour the entire contents of the Part A and Part B containers into the now empty pail. ® Caution: Do not change the mixing ratio of Super Spec HP Concrete Crack Repair Kit (P72). Blend thoroughly for 2 minutes using a spiral mixing blade in a variable speed (400–600 rpm) electric drill, or use a Jiffy Mixer. Place the spiral mixing blade at the bottom of the material before turning on the mixer to avoid inducing air into the material while mixing, which will lead to greater porosity in the finished mortar. Gently move the running mixer toward the surface, but do not remove while spinning. Slowly add the Part C aggregate to the liquid mixture in the pail. Blend until all the aggregate is thoroughly mixed, covered, or saturated with the liquid mixture (1 minute). Application Apply the epoxy/aggregate mixture immediately after mixing by pouring the material onto the floor and spreading with a trowel until the desired texture and thickness are achieved. When repairing cracks or spalled concrete, apply material flush with the surrounding floor. Excess material around a repair, once cured, may be ground smooth with a diamond grinder or grinding stone. For best results: Apply a test patch first to ensure compatibility. Do not use when humidity exceeds 70% indoors. For interior use only. If product has been frozen, allow to completely warm up to 70° F before using. A vapor barrier must be used beneath the substrate to be coated to prevent loss of adhesion. For best ® adhesion, prime first with Super Spec HP Fast Dry Epoxy Floor ® Sealer/Finish (P41) or Super Spec HP Concrete Crack Repair Kit (P72) A & B only. If priming with P72 A & B, the repair mortar should be applied while primer is still “wet.”. Thinning/Cleanup DO NOT THIN. Clean all equipment immediately after use with Super Spec HP Epoxy Thinner (P95). USE COMPLETELY OR DISPOSE OF PROPERLY. This product contains components which may cause adverse affects to the environment if handled improperly. Dry empty containers may be recycled in a can recycling program. Local disposal requirements vary; consult your sanitation department or state-designated environmental agency on disposal options. Environmental, Health & Safety Information Contains: Epoxy Resin, P-tert-Butylphenol, Nonyl Phenol, Benzene-1,3-Dimethamine CAUSES SEVERE EYE AND SKIN BURNS. HARMFUL OR FATAL IF SWALLOWED. SEVERE ASPIRATION HAZARD. HARMFUL IF ABSORBED THROUGH SKIN. VAPORS MAY AFFECT CENTRAL NERVOUS SYSTEM CAUSING DIZZINESS, HEADACHES AND NAUSEA, MAY CAUSE ALLERGIC SKIN REACTION IMPORTANT: Designed to be mixed with other components. Mixture will have hazards of both components. Before opening packages, read all warning labels. Follow all precautions. NOTICE: Repeated or prolonged exposure to organic solvents may lead to permanent brain and nervous system damage. Intentional misuse by deliberately concentrating and inhaling vapors may be harmful or fatal. Use only with adequate ventilation. Do not breathe vapors or sanding dust. Avoid contact with eyes, skin and clothing. Wear chemical resistant goggles and face shield, chemical resistant gloves and protective clothing during application and cleanup. Do not wear contact lenses. Open doors, windows or use other means to ensure fresh air entry during application and cleanup. If you experience eye watering, headache or dizziness or if air monitoring demonstrates vapor levels are above applicable limits, wear an appropriate, NIOSH approved, properly fitted respirator during use and cleanup. Follow respirator manufacturer’s directions for respirator use. Do not permit anyone without protection in the painting area. Wash thoroughly after handling. Close container after each use. FIRST AID: If affected by inhalation of vapors or sanding dust, remove to fresh air. In cases of eye contact, flush immediately with copious amounts of water holding eyelids open for at least 15 minutes and call a physician immediately; for skin, remove contaminated clothing and flush affected area with water for at least 15 minutes. In case of ingestion, DO NOT INDUCE VOMITING, get medical help immediately. IN CASE OF: FIRE — Use foam CO2, dry chemical or water fog. SPILL —Absorb with inert material and dispose of as specified under “Clean Up”. KEEP OUT OF REACH OF CHILDREN Refer to Material Safety Data Sheet for additional health and safety information. Benjamin Moore & Co., 101 Paragon Drive, Montvale, NJ 07645 Tel: (201) 573-9600 Fax: (201) 573-9046 www.benjaminmoore.com M72 P72 US 033011 Benjamin Moore, Super Spec HP, and the triangle “M” symbol are registered trademarks of Benjamin Moore & Co., Limited. ® © 2008, 2011 Benjamin Moore & Co., Limited All rights reserved
© Copyright 2026 Paperzz