Evolution in Automation Paulo Afonso I, II and III Hydroelectric plants Paulo Afonso Complex Modernization First stage conclusion: 06/2008 Project Location: Paulo Afonso/BA - Brazil Controlled I/O Points: About 150.000 points Paulo Afonso I, Paulo Afonso II and Paulo Afonso III plants are in the same impoundment. The Plant I (USU) has three generators and starts the operation in 1955. The Plant II (USD) has six generators and starts operation in 1961. Power Plant III (UST) has four generators and starts operation in 1971. The project was divided into stages, where the first would be the USU, its substation, water intake, and ancillary services. Still exist in the complex, the Plants of Paulo IV and Apolônio Sales, which have not been modernized in this contract. The main benefits of the system: Supervision and remote control; Reliability and robustness of the communication system with more accurate diagnoses; Easy maintenance Supervisory system, where the client can make small adjustments and additions of points; Inclusion of a station close to the generators, allowing faster starting and stopping of the generators and helps the maintenance; Gains in production; Synchronization between AUs and monitoring system with GPS, allowing checking the sequence of events of the system. The scope of the solution provided by Altus are the following equipment and services: • Specification, design and assembly of electrical panels: Altus has been contracted by Chesf with the following objectives: o 13 generator AUs; - Implement an engineering solution for monitoring, control and protection of the generating units, outlet sluice of water, substations and ancillary services, with the main features: o 20 Substation AUs; o 4 Auxiliary Service AUs; o 3 water intake points; - Record of events with an accuracy of 1ms for all digital inputs; o Local boards and MCCs; - Record of events with precision of 100 ms for all analog inputs; o Protection Tables; - Network in dual redundant optical ring to increase security and enhance performance in communications between the AUs (autonomous units) and the supervisory system; - Supervision system with redundant servers; - Redundant Database System; - Synchronize AUs satellite (GPS); - Provide information and events to the ONS (Electric System National Operator); Benefits Paulo Afonso I, II and III Hydroelectric plants are located in the river São Francisco, in Paulo Afonso Bahia. In total, they operate with 13 generator units and an installed capacity of 1,417,000 kW. o Low and medium voltage distribution boards. • Design and installation of the GPS network synchronization; • Design and installation of optical Ethernet network for communication; • Project; o Generator Units control and protection Project; o Unifilar, trifilar, functional and logical Diagrams; Scope Description Scope: Projeto, Hardware, Serviço de Integração Electrical Sector Chesf - Companhia Hidrelétrica do São Francisco o Interconnection and lists of cables Diagrams; - Disturbance and monitoring system; o Design of the transformers of the ancillary services - Redundant Protection relays; o Electrical conduits Project • Instrumentation; • Assembly; • Commissioning and assistance operating; • Training PI 28967 Rev B - 10/2010 Evolution in Automation Aplication Pictures Chesf - Companhia Hidrelétrica do São Francisco PI 28967 Rev B - 10/2010 Evolution in Automation Chesf - Companhia Hidrelétrica do São Francisco Supervision and Control To implement the system, two "Hot Stand-By" supervision servers were provided communicating with all AUs via optical ring communication (ethernet). The screens show the data in real time. PI 28967 Rev B - 10/2010 Evolution in Automation Chesf - Companhia Hidrelétrica do São Francisco Networking Architecture In each AU and in the communication hub were used "RuggedCom" industrial switches to construct the double optical ring communication. ALNET II TCP, Modbus TCP, DNP3 or IEC 60870-5-103 are the protocols of this network. Three optical ports Switch. The third port is used to connect the adjacent rings. Two optical ports Switch. Both optical ports are used to the local ring. Two optical ports Switch. Both optical ports are used to the local ring. Besides, it provides an alternative electrical connection route between both rings of each plant. Below architecture of generator control AUC: PI 28967 Rev B - 10/2010 Evolution in Automation Contact Chesf - Companhia Hidrelétrica do São Francisco Client Contact for more information: Carlos Roberto Lopes dos Santos Phone: +55 75 3282 2120 Altus Sistemas de Informática S.A. Av. Theodomiro Porto da Fonseca, 3101 – Lote 01 - Bairro Duque de Caxias CEP 93020-080 – São Leopoldo – RS Fone: +55 51 3589 9500 Fax: +55 51 3589 9501 www.altus.com.br PI 28967 Rev B - 10/2010
© Copyright 2025 Paperzz