GE Lighting Data Sheet High Power White LED 70CRI and 85CRI 1, 4 and 7 watt 3000K, 3500K and 4100K Delivering outstanding light quality and stability • <75 Kelvin color change over 50,000 hours • Uniform, diffused white light in high flux package • Highly efficient performance in warm white color — up to 55 lpw • 70% lumen maintenance after 50,000 hours of operation • Operating current of 500mA (Tboard 85°C) for 1 & 4 watt and 350mA (Tboard 85°C) for 7 watt* • High flux package in warm white colors — up to 350 typical lumens at 350mA for 7W • Reduced part-to-part color variation: ±200 Kelvin for full color bins, and ±100 Kelvin for half-bins Advanced technology • Application driven CCT bin limits centered on general illumination color points • Proprietary phosphor technology provides flexible CCT and CRI options • Patented package design • Plug-and-play connection to power source • Thermocouple Tboard measurement point for design validation accuracy GE Reliability • • • • • Designed for Six Sigma Quality Package qualified using rigorous test protocals Robust ESD Class II rating (Human Body Model) Mercury-free, RoHS compliant Up to 50,000 hour rated life Multiple applications • • • • • • Area lighting Display lighting Accent lighting Landscape lighting Architectural lighting General Illumination *7W can be operated up to 500mA. Contact us for reccomendation. Vio Data Sheet Data Sheet Vio Nomenclature Electrical and Optical Performance Part Number 73357 73355 73353 73351 73349 73347 73356 73354 73352 73350 73348 73346 74759 74760 74761 74762 74763 74764 CCT CCT CCT Description CRI Min. Typical Max. Vio/1.2W/730 70 2800 3000 3200 Vio/1.2W/735 70 3300 3500 3700 Vio/1.2W/741 70 3900 4100 4300 Vio/1.2W/830 85 2800 3000 3200 Vio/1.2W/835 85 3300 3500 3700 Vio/1.2W/841 85 3900 4100 4300 Vio/3.6W/730 70 2800 3000 3200 Vio/3.6W/735 70 3300 3500 3700 Vio/3.6W/741 70 3900 4100 4300 Vio/3.6W/830 85 2800 3000 3200 Vio/3.6W/835 85 3300 3500 3700 Vio/3.6W/841 85 3900 4100 4300 Vio/7.2W/730 70 2800 3000 3200 Vio/7.2W/735 70 3300 3500 3700 Vio/7.2W/741 70 3900 4100 4300 Vio/7.2W/830 85 2800 3000 3200 Vio/7.2W/835 85 3300 3500 3700 Vio/7.2W/841 85 3900 4100 4300 Watts 1.2 1.2 1.2 1.2 1.2 1.2 3.6 3.6 3.6 3.6 3.6 3.6 7.2 7.2 7.2 7.2 7.2 7.2 Lumens Typical 64 67 69 55 55 57 171 188 196 142 153 160 300 350 330 250 275 285 Lumens per Watt Typical 53 55 57 45 45 47 48 53 55 40 43 45 44 52 49 36 41 42 Forward Voltage (Vf) Min. 3.2 3.2 3.2 3.2 3.2 3.2 9.6 9.6 9.6 9.6 9.6 9.6 18 18 18 18 18 18 Forward Voltage Typical 3.5 3.5 3.5 3.5 3.5 3.5 10.2 10.2 10.2 10.2 10.2 10.2 20 20 20 20 20 20 Forward Voltage (Vf) Max. 4 4 4 4 4 4 12 12 12 12 12 12 22 22 22 22 22 22 5 second pulse (all data measured at Tb = 25°C, If = 350 mA) Electrical Connection 5 1 Connector on Board: Molex 53261-0271 2 Mating Connector: Molex 51021-0200 3 Connector Crimp Terminal: 50079-8100 4 Recommended Attachment Screw: 4-40 Hex 5 Accessory: 24" Connector Harness GE-VHD-CON-M01-024 2 3 1 4 4 2 Vio Data Sheet Data Sheet Package Dimensions (All dimensions in millimeters.) Testing Protocol Operational Non-energized Test Item Time Requirement Test Protocol Specific Conditions Failure Criteria* High Temperature Storage 1000 hrs JEITA ED-4701 200, 201 Ta=100°C <30% lm Low Temperature Storage 1000 hrs -40°C <30% lm High Temperaure/Humidity Storage 1000 hrs 60°C/RH90% • 1000 hrs <30% lm 500 cycles -40°C to 110°C (20min. dwell time, <20 seconds transfer) <10% lm Thermal Shock ESD-Human Body Model 3x EIAJ ED 4701• Method 304,Level 2 +/-2kV to 4KV • Minimal +/-2kV <30% lm High Temperature Operating Life 1 1000 hrs Mil Std 810 • Method: 501.4 T ambient = 85°C, If = 350mA <30% lm High Temperature Operating Life 2 1000 hrs Mil Std 810 • Method: 501.4 T ambient = 55°C, If = 500mA <10% lm Low Temperature Operating Life 1000 hrs Mil Std 810 • Method: 502.4 Ta = -40°C, If = 350mA <30% lm High Temperature/Humidity Forward Bias 1000 hrs Ta = 60°C, 90% RH, 350mA <30% lm Room Temperture Operating Life 1000 hrs Ta = 25°C, 500mA <10% lm Physical Mechanical Shock 5/axis position Vibration Variable Frequency 3 axis Vibration Variable Frequency 3 axis Random Vibration 2 EIAJ ED 4701 Method 403 Sinusoidal 3 axis Accel: 14,700 M/s • Axis: 6 Pulse shape: Half Sine, 0.5 ms PW <30% lm <30% lm Peak Accl. = 20 gms (9.8m/s2) Freq. Range = 100 to 2000 to 100 Hz Displacement: 1.5mm • Sweep Rate: 4 minute <30% lm <30% lm <30% lm Peak Accl. = 10gms, Freq. Range = 10 to 55 to 10 Hz Displacement: +/- .75mm Freq. Range: 55 to 2000hz at 10G 1 octive/min, 3x/axis <30% lm Amplitude: 6 grms Range: 10 to 2000 hz • Dwell: 20 minutes <30% lm * ‘O’ failures in test population. 3 Vio Data Sheet Data Sheet Color Bins Color Binning Chart 411 412 CCT ccx ccy CCT ccx ccy 4300 0.364 0.351 4100 0.381 0.393 4100 0.372 0.357 3900 0.390 0.398 4100 0.381 0.393 3900 0.380 0.362 4300 0.372 0.387 4100 0.372 0.357 0.45 352 302 301 351 412 0.4 411 3000K 351 352 3500K CCT ccx ccy CCT ccx ccy 3700 0.389 0.367 3500 0.412 0.410 3500 0.399 0.373 3300 0.425 0.415 3500 0.412 0.410 3300 0.410 0.379 3700 0.401 0.404 3500 0.399 0.373 301 4100K 0.35 Planckian Locus 0.3 302 0.3 0.35 0.4 0.45 0.5 • Application binning centered at 60°C Tb. CCT ccx ccy CCT ccx ccy 3200 0.416 0.381 3000 0.446 0.422 3000 0.428 0.387 2800 0.461 0.426 Bin Min Max Bin Min Max 3000 0.446 0.422 2800 0.443 0.391 A 20 25 I 119 149 3200 0.431 0.418 3000 0.428 0.387 B 25 31 J 149 186 C 31 39 K 186 233 D 39 49 L 233 291 E 49 61 M 291 364 F 61 76 N 364 455 G 75 95 O 455 568 H 95 119 P 568 711 Luminous Flux Bins • Color coordinates measurements allowance is ±0.01 • Measured at If = 350 mA Forward Voltage Bins 1 Watt • Measured at Tb = 25°C, If = 350 mA, 5 second pulse. • Measurement tolerance ±10% 4 Watt Bin Min 7 Watt Bin Min Max Max 0 3.00 3.25 T 9.50 10.25 Bin Min Max 1 3.25 3.5 U 10.25 11.00 X 19.0 20.5 2 3.50 3.75 V 11.00 11.75 Y 20.5 22.0 3 3.75 4.00 W 11.75 12.50 Z 22.0 23.5 • Measured at Tb = 25°C, If = 350 mA • Measurement tolerance ±0.1 V Application Specific Bins 4100K Estimated Application Operating Temperature 3500K 3000K Tb Bin +/- CCT Tb Bin +/- CCT Tb Bin +/- CCT 60°C Full 200K 60°C Full 200K 60°C Full 200K <60°C 411 100K <60°C 351 100K <60°C 301 100K >60°C 412 100K >60°C 352 100K >60°C 302 100K • Full CCT bins centered on 60°C Tb operating temperature, 5 second pulse. • Choose sub-bins based on operating Tb temperature range of application. 4 Vio Data Sheet Data Sheet Emission Spectrum-70CRI Emission Spectrum-85CRI 4100 4100 3500 3500 3000 3000 5.00E-03 4.50E-03 6.00E-03 4.00E-03 5.00E-03 3.50E-03 4.00E-03 2.50E-03 3.00E-03 2.00E-03 1.50E-03 2.00E-03 1.00E-03 1.00E-03 5.00E-04 0.00E+00 370 420 470 520 570 620 670 0.00E+00 720 770 370 420 nm 520 570 620 670 720 770 Forward Voltage vs. Drive Current 600 Drive Current (mA) Normalized Intensity 1.40 1.20 1.00 0.80 0.60 0.40 0.20 0.00 470 nm Relative Luminosity vs. Drive Current 1 & 4 Watt 7 Watt 0 100 200 300 400 500 500 400 300 200 1 & 4 Watt 7 Watt 100 0 7 watt 19.0 19.2 19.4 19.6 19.8 20.0 20.2 20.4 7 watt 4 watt 9.2 9.4 9.6 9.8 10.0 10.2 10.4 10.6 4 watt 1 watt 2.9 3.0 3.1 3.2 3.3 3.4 3.5 3.6 1 watt 600 Drive Current (mA) Data collected under steady conditions at 25°C Tb. Results may vary in applications. (Vf) Light Output vs. Board Temperature Derating Curve Rb-a 5°C/W Rb-a 10°C/W 1.20 Rb-a 15°C/W Drive Current (mA) 1.00 %Lms @ 25C Tb % 3.00E-03 0.80 0.60 0.40 7 Watt (350mA) 1 & 4 Watt (350mA) 1 & 4 Watt (500mA) 0.20 0.00 20 30 40 50 60 70 80 90 0 10 20 30 40 50 60 70 Ambient Temperature (Ta) 80 Based on Tboard max of 85°C Tb Data collected under steady operation. Results may vary in applications. 400 350 300 250 200 150 100 50 0 5 Vio Data Sheet 90 Data Sheet Radiation Pattern 0 10 10 1 Watt 4 Watt 7 Watt 20 0.40 30 40 0.75 40 0.20 50 50 0.5 60 70 0.00 60 -0.20 dVf 30 20 Forward Voltage vs. Board Temperature 70 0.25 80 80 90 90 -0.40 -0.60 -0.80 0 10 20 30 40 50 60 70 80 90 Tb Color Change with Drive Current 5 second pulse @ 350mA (3500K, 85CRI Example) 0.430 0.420 0.410 0.400 0.390 200mA 350mA 500mA 100mA 50mA 0.380 0.370 0.360 0.350 0.370 0.380 0.390 0.400 0.410 0.420 0.430 0.440 0.450 Tb = 25°C, 5 second pulse measurement Absolute Maximum Ratings Parameters Forward Current Symbol Value If 700 mA Peak Pulsed Forward Current 700 mA Storage Temperature MCPCB Temperature ESD Sensitivity -40 to 100 °C Tb 85 °C (Human Body Model) Class II (2-4 kV) *Proper current derating must be considered to maintain Tb below 85°C. *Exceeding the maximum ratings can result in damage to the LED. These limits apply to a single parameter in operation. Do not operate more than one parameter at the maximum level at the same time. 6 Vio Data Sheet Data Sheet Packaging Drawings 10 parts per sleeve 50 parts per carton 7 Vio Data Sheet Data Sheet High Power White LED Handling Information The phosphor-coated hemisphere on Vio LEDs is made of glass. Adequate care in handling should be taken to avoid damaging the emitter, and incurring an injury. Store at -40°C to 100°C in a clean and dry location. Vio LEDs do not have a specific shelf life if stored under proper conditions. E319084 E319084 Information provided is subject to change without notice. Please verify all details with GE. All values are design or typical values when measured under laboratory conditions, and GE makes no warranty or guarantee, expressed or implied, that such performance will be obtained under end-use conditions. For additional product and application information, please consult GE’s Website: www.gelighting.com ILUM003 9/2009 Vio and “The look that lasts” are trademarks of Lumination, LLC. The GE brand and logo are trademarks of the General Electric Company. Printed in the USA 8
© Copyright 2026 Paperzz