1738 Quick Setup for Pre-Programmed Systems Step 1: Connecting Hardware If you are using EOL resistors, refer to “Hardwire Zone Connection Using EOL Resistors” on page 4. Step 2: How to Program 2.1 2.2 Step 3: Section [143] [151] [153] [ENTER] J[INSTALLER CODE] (default: 0000) J[SECTION] J[DATA] J[ENTER] to save. Press [CLEAR] at any point to exit and then enter a new section. Minimum Programming for Monitoring Station Reporting Description Data Partition 1 Account Number (press the [FORCE] key if less than 4 digits; to enter hexadecimal values refer to the “Decimal and Hexadecimal Programming Table” on page 4) ____/____/____/____ Monitoring Station Telephone Number 1 (press the [ENTER] key if less than 32 digits) __________________________________ Backup Monitoring Station Telephone Number (press the [ENTER] key if less than 32 digits) __________________________________ Maximum: 32 digits Maximum: 32 digits 1 Step 4: Optional Programming with Defaults and Pre-Programmed Settings If a hardware reset is performed, the control panel will reset to factory defaults (refer to the Spectra Programming Guide) and the pre-programmed settings will be lost. † = pre-programmed setting Section Description Data Zone Definitions Empty slot [FORCE] - Disabled 1 - Entry Delay 1 Additional definitions for on2 - Entry Delay 2 board terminals: 3 - Follow 7 - Keyswitch 4 - Instant 8 - Standard 24Hr Fire 5 - 24Hr Buzzer 9 - Delayed 24Hr Fire 6 - 24Hr Burglary Partition Assignment Empty - Zone disabled 1 - Partition 1 2 - Partition 2 3 - Both partitions [4] [5] OFF OFF Steady Alarm OFF ON Pulsed Alarm ON OFF Silent Alarm ON ON Report Only Zone Options [6] - Intellizone [7] - Delay before transmission [8] - Force Zone Zone Alarm Type Keyswitch Options [1] - OFF = Maintained / ON = Momentary [2] - OFF = Regular arm / ON = Stay arm Zone 1 : Entry Delay 1 zone 1 /____ 1 ____ ( 1 2 * * * * * *) Zone 2 : Follow zone (Stay Zone enabled) 3 /____ 1 ____ ( 1 2 3 * * * * *) Zone 3 : Instant zone 4 /____ 1 ____ ( 1 2 * * * * * *) Zone 4 : Instant zone 4 /____ 1 ____ ( 1 2 * * * * * *) Zone 5 : Instant zone 4 /____ 1 ____ ( 1 2 * * * * * *) Zone 6 : Instant zone 4 /____ 1 ____ ( 1 2 * * * * * *) Zone 7 : Instant zone 4 /____ 1 ____ ( 1 2 * * * * * *) PGM1 Timer 0 3 0 seconds ____/____/____ [069] Entry Delay 1 0 4 5 seconds ____/____/____ [070] Entry Delay 2 0 4 5 seconds ____/____/____ [071] Exit Delay 1 0 3 0 seconds ____/____/____ [072] Exit Delay 2 0 3 0 seconds ____/____/____ [073] Bell Cut-off Timer Partition 1 0 0 4 minutes ____/____/____ [077] † [001] † [002] † [003] † [004] † [005] † [006] † [007] † [066] † Answering Machine Override Delay (000 to disable) 0 3 2 seconds ____/____/____ Event Group # Sub-group # Partition # 0 1 _____/_____ 0 1 _____/_____ [120] † PGM1 Activation Event ([PG]/[FNC1] was pressed; smoke reset) 0 5 _____/_____ [126] † PGM1 Normal State Option [4] OFF = N.O. ON = N.C. Option [8] OFF = Disabled 3 ON = Enabled Option [4] OFF = Disabled ON = Enabled Option [6] OFF = Disabled 3 ON = Enabled Option [1] OFF = Disabled ON = Enabled Zone 1 becomes 2-wire smoke detector input [127] † Lock System Master Code User Code 048 is a Duress Code [128] 2 [1] - Auto-zone Shutdown Enabled [2] - Bypass Enabled [3] - Stay Zone † Panic 1 (keys [1] and [3]) 3 3 3 † = pre-programmed setting † Panic 2 (keys [4] and [6]) Option [2] OFF = Disabled † Panic 3 (keys [7] and [9]) Option [3] OFF = Disabled † Panic 1 alarm type Option [4] OFF = Silent Alarm † Panic 2 alarm type Option [5] OFF = Silent Alarm † Panic 3 alarm type Option [6] OFF = Silent Alarm 3 3ON = Enabled 3ON = Audible Alarm 3ON = Audible Alarm 3ON = Fire Alarm [129] † Wireless Module Low Battery Supervision Option [6] OFF = Disabled ON = Enabled [130] † One-touch Regular Arming Option [1] OFF = Disabled ON = Enabled † One-touch Stay Arming Option [2] OFF = Disabled † One-touch Force Arming Option [3] OFF = Disabled † One-touch Bypass Programming Option [4] OFF = Disabled 3 3ON = Enabled 3ON = Enabled 3ON = Enabled [131] † No exit delay beeps and no bell squawk when Stay arming Option [5] OFF = Disabled ON = Enabled [132] EOL (End-of-line) resistors Option [4] OFF = No EOL 3 ON = with EOL [133] Switch to Stay Arming if no entry delay is opened Option [4] OFF = Disabled 3 ON = Enabled [135] † Dialer Option [3] OFF = Disabled ON = Enabled [137] † Call Telephone #1 for Arming/Disarming Report Codes Option [1] OFF = Disabled 3 ON = Enabled [140] Reporting formats for telephone numbers 1 and 2. Enter a number from 1 to 6. (1 = ADEMCO slow; 2 = Silent Knight fast; 3 = SESCOA; 4 = ADEMCO Express; 5 = ADEMCO Contact ID; 6 = Pager) [302] † Master Code 1 ( 1 * 3 4 5 * * *) [303] † Master Code 2 ( 1 * 3 4 5 * * *) [304] † User Code 004 ( 1 * 3 4 5 * * *) [348] † User Code 048 ( 1 * 3 4 5 * * *) ON = Enabled 3 3 3 5 /_____ 5 _____ Tel.# 1 Format Tel.# 2 Format User Options [5] Force Arming [1] Partition 1 access [6] Arm only [2] Partition 2 access [7] PGM activation only [3] Bypass programming [8] Future use [4] Stay arming Buttons Section + * + + * + * 4 5 _____ _____ _____ Remote control # 1 _____ _____ _____ _____ _____ 4 5 _____ _____ _____ Remote control # 2 _____ _____ _____ _____ _____ 4 5 _____ _____ _____ Remote control # 3 _____ _____ _____ _____ _____ 4 5 _____ _____ _____ Remote control # 4 _____ _____ _____ _____ _____ 4 5 _____ _____ _____ Remote control # 5 _____ _____ _____ _____ _____ 4 5 _____ _____ _____ Remote control # 6 _____ _____ _____ _____ _____ 4 5 _____ _____ _____ Remote control # 7 _____ _____ _____ _____ _____ 4 5 Remote control # 8 _____ _____ _____ _____ _____ _____ _____ _____ [711] † [712] † [713] † [714] † [715] † [716] † [717] † [718] † Button Options Empty slot [FORCE] = Button disabled 1 - Regular arming 2 - Stay arming 3 - Instant arming 4 - Force arming 5 - Disarm 6 - Disarm when no alarm 7 - Regular arm and disarm 8 - Panic 1 9 - Panic 2 A - Panic 3 B - PGM activation (Event group # 07) C - PGM activation (Event group # 08) D - PGM activation (Event group # 09) * = The greyed-out columns indicate button combinations not available with the MG-REM1 remote control and cannot be programmed. 3 Step 5: Testing • Arm the system with [MASTER CODE] (default: 1234) • Trigger zones to verify operation Decimal and Hexadecimal Programming Table What Do I See? Value or Action What Do I Press? 1686V 1686H 1689 1641 1640 10-Zone LED 16-Zone LED LCD Icon LCD Values 1 to 9 [1] to [9] [1] to [9] [1] to [9] [1] to [9] [1] to [9] A (HEXA ONLY) [0] [0 (10)] [10] 0 0 B (HEXA ONLY) [STAY] / [STAY] [11] B B C (HEXA ONLY) [BYP] / [BYP] [12] C C D (HEXA ONLY) [MEM] / [MEM] [13] D D E (HEXA ONLY) [TBL] / [TRBL] / [TBL] [14] E E F (HEXA ONLY) [PG] / [FNC1] / [PG] [15] F F [CLEAR] / [ENTER] flashes [ARM1] & [STAY1] flash “PROGRAMMING MODE [ ] SECTION” “SECTION” In Programming Mode / Waiting for a Section __ [ENTER] flashes [ARM1] & [STAY1] flash “PROGRAMMING MODE [ ] SECTION” “SECTION” Enter a Space / Erase Current Digit [FORCE] / Exit Without Saving Save Data (HEXA ONLY) [ENTER] / Displays next digit or next section Advances to the next section Installer Quick Keys To access the installer quick keys, press the [ENTER] key, enter your [INSTALLER CODE] and then press: • [TBL] or [TRBL] (Installer Test Mode): The Installer Test Mode will allow you to perform walk tests. • [MEM] (Test Report): Sends the “Test Report” report code programmed in section [211] to the monitoring station. • [BYP] (Call WinLoad): Dials the PC telephone number (section [150]) to initiate communication with WinLoad. • [STAY] (Cancel Communication): Cancels all communication with WinLoad or monitoring station until next reportable event. • [FORCE] (Answer WinLoad): Will force the control panel to answer an incoming call from WinLoad. Hardwire Zone Connection Using EOL Resistors Printed in Canada - 10/2004 4 1738-EQ02
© Copyright 2026 Paperzz