Designed Specifically For Use With Tankless Water Heaters! CDXQR Series Multi-family Cased Celing Fan Coil 1-1/2 - 3 Tons Cooling Up to 31,400 BTUH HW Heat The CDXQR series fan coils are designed specifically for use with tankless water heaters. These fan coils allow high efficiency tankless water heaters to be used for two jobs instead of one....providing domestic hot water and high efficiency space heating! They are compatible with most of today's higher efficiency split-system R-410A heat pumps and condensing units. Contact the factory or go to www.firstco.com/Efficiency-Ratings for approved indoor/outdoor combinations. The space-saving CDXQR is an 11" high cased ceiling fan coil. Its compact size allows it to recess into a confined ceiling space, thus saving valuable floor space by eliminating costly furnace/air handler closets. Important: In order for the CDXQR to operate properly with tankless water heaters, the hot water coils must be piped to the tankless heaters according to the tankless manufacturer's instructions. Contact the water heater manufacturer for required accessories and piping requirements, as well as water heater sizing information. The CDXQR fan coils include a special circulating pump designed for tankless heaters, HW check valve, air purge valve, hot water coil, cooling coil, blower/motor, and multi-function circuit board. The fan coil is factory installed within an insulated enclosure or "case" and is shipped with your choice of either a solid or louvered access panel with attractive off-white powder coat finish. Solid panels must be used with ducted return air applications, while louvered panels (the default style) should be used with non-ducted return air applications. Louvered panels include filters, but solid panels require field supplied return-air filter / grilles. Standard Features: Insulated Case (Solid Panel shown) • Multi-function micro-processor circuit board with: • Automatic pump timer (heating mode) - pump purges the HW coil for 60 seconds every six hours. Note: State of MA, .248 CMR code of the state of MA requires a pump timer. (60 seconds every 6 hours) • Blower-on fan delay (heating mode) - preheats the HW coil for 45 seconds. • Blower-off fan delay (heating and cooling modes) - blower continues to operate for 45 seconds after thermostat is satisfied for increased efficiency. • Factory installed service switch • Freeze protector on HW coil • Special circulating pump with unique, easy access anti-siphon check valve and air purge valve • 120V motor, 24V controls • Higher efficiency cooling coil with installed R-410A TXV (non-bleed type) • Insulated and coated galvanized steel drain pan, sloped for proper drainage • Attractive off-white louvered or solid return-air / access panel with captive screws (panels can be field painted) • Drain pan has 3/4" MPT primary and secondary fittings • Effective January 2016, Cabinet air leakage is no more than 2% when tested in accordance with ASHRAE 193. Optional Accessories: (see P. 3) • • Louvered IAQ filter panels with Merv 8 filters Condensate overflow switch (field installed) FIRST CO. - P.O. Box 270969 - Dallas, Texas 75227 - Ph. (214) 388-5751 - Fax (214) 388-2255 - www.firstco.com DRAIN CONNECTIONS PRIMARY CONNECTIONS AT BOTH ENDS. SECONDARY CONNECTION AT THIS END ONLY (3/4” MPT) CDXQR Series HW COIL 7/8" O.D. (sweat) SUPPLY 1-1/2 through 3 tons HW COIL 7/8" O.D. (sweat) RETURN (See P. 3 for Model Numbers) H W C O I L D X 6 -1 /2 C O I L SERVICE SWITCH AND ELECTRICAL CONNECTIONS LEFT SIDE (OPPOSITE SIDE SHOWN) COOLING COIL LIQUID LINE 3/8 O.D. SWEAT SUCTION LINE 5/8 O.D. SWEAT 18-30CDXQ SUCTION LINE 7/8 O.D. SWEAT 31,36 & 37CDXQ (See P. 3 for Model Numbers) PHYSICAL DIMENSIONS UNIT MODEL A B C D 19CDXQR 45-1/8 37-1/4 30-1/8 34-3/4 20-25CDXQR 51-1/8 43-1/4 36-1/8 40-3/4 26-31CDXQR 57-1/8 49-1/4 42-1/8 46-3/4 32-37CDXQR 64-1/8 56-1/4 49-1/8 53-3/4 BLOWER DATA UNIT MODEL 19/20CDXQR CFM vs. EXTERNAL STATIC PRESSURE (3) 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 710 680 650 620 590 560 530 500 25/26CDXQR 880 840 800 760 720 680 640 600 31CDXQR 1100 1060 1020 980 930 880 830 780 32CDXQR 1160 1130 1095 1060 1025 990 950 910 37CDXQR 1310 1260 1210 1160 1110 1060 1000 940 (1) Units should not be applied to a system with less than 350 CFM/Ton airflow. (2) Motors are 120V and operate on high speed for cool and low speed for heating. (3) CFM vs. static at motor cooling speed. (4) Add .05 static when enclosure and/or ceiling panel are used. (5) 31, 32, 36 and 37CDXQ have two motors and four blowers. PERFORMANCE DATA BTUH (1000) AT ENTERING WATER TEMPERATURE NOMINAL COOLING BTUH HEATING GPM PRESS. DROP (FT. WTR) 120 F 130 F 140 F 180 F 19CDXQR 18,000 3 3.3 12.9 15.4 18.0 28.3 20CDXQR 18,000 3 4.1 13.7 16.5 19.2 30.2 25CDXQR 24,000 3 4.1 15.9 19.0 22.2 34.9 26CDXQR 24,000 3 4.3 17.0 20.4 23.8 37.4 31CDXQR 30,000 3 4.3 18.8 22.5 26.3 41.3 32CDXQR 30,000 3 5.4 20.1 24.2 28.2 44.3 37CDXQR 36,000 3 5.4 21.7 26.1 30.4 47.8 UNIT MODEL o o o o In keeping with its policy of continuous progress and product improvement, First Co. reserves the right to make changes without notice. Maintenance for all First Co. products is available under "Product Maintenance" at www.firstco.com. NOTES: 1. Heat BTUH is at 70 degree EAT. 2. 120 degree and 180 degree data is supplied for boiler applications. 3. Heating BTUH output will not exceed output of water heater. 4. Approved for installation with 0" clearance to combustible material. EXPANSION VALVE KITS (Heat Pump or cooling only) (FIELD INSTALLED) ELECTRICAL DATA UNIT MODEL MOTOR HP (120V) MOTOR AMPS (120V) PUMP MIN. CIR AMPACITY MAX CIR PROTECTION 19/20CDXQR 1/5 2.3 0.84 4 15 25/26CDXQR 1/4 3.6 0.84 6 15 31CDXQR 1/5 (2) 4.6 0.84 7 15 32CDXQR 1/5 (2) 4.6 0.84 7 15 37CDXQR 1/5 (2) 4.6 0.84 7 15 PART NO. TYPE FOR 9EVR410-1 R410A 19 - 37CDXQR (1-1/2 - 3 TON) NOTES: 1.Above expansion valve kits are approved for both cooling only (non heat pump) or heat pump applications. 2.Valves are non-bleed type. Field added. Hard start kit may be required. 3.Valves have screw-on connections. -2- CDXQR Series 1-1/2 through 3 tons PHYSICAL DIMENSIONS MODEL A B 45-3/4 30-7/8 34 20/25CDXQR 51-3/4 36-7/8 40 32/37CDXQR 58-1/2 66-1/2 PANEL NO. (IAQ) DESCRIPTION (1) W L W L 966 966-M8 LOUVERED 24-1/2 46 27-1/2 49 966-1 NA NON-LOUVERED 24-1/2 46 27-1/2 49 C 19CDXQR 26/31CDXQR PANEL NO. (STD.) 42-7/8 46-3/4 49-7/8 54-3/4 CEILING PANEL OPENING PANEL FRAME DIMS (OUTSIDE) 967 967-M8 LOUVERED 24-1/2 52-1/2 27-1/2 55-1/2 967-1 NA NON-LOUVERED 24-1/2 52-1/2 27-1/2 55-1/2 967-6 967-6-M8 LOUVERED 24-1/2 60 27-1/2 63 967-7 NA NON-LOUVERED 24-1/2 60 27-1/2 63 967-8 967-8-M8 LOUVERED 24-1/2 67 27-1/2 70 967-5 NA NON-LOUVERED 24-1/2 67 27-1/2 70 (See Panel Pictures Below) NOTES: (1) Louvered is the "default" style and automatically shipped unless non-louvered is specified on order. 7" 6 7/8" 2 7/8" 11" 5 7/8" 23 7/8" 5 1/2" B A 2 1/2" 2" C TEMPLETE FOR DUCTED RETURN (Ducted return requires remote filter grille (field supplied) and non-louvered panel) STANDARD PANELS # 966-1, 967-1, 967-7 # 966, 967, 967-6 (Louvers may differ from picture) Louvered panels accept 20x20x1" filter (field supplied) IAQ PANELS # 966-M8, 967-M8 (accepts 2-20x20x1 filter) # 967-6-M8 (accepts 2-20x25x1 filter) # 967-8-M8 (accepts 2-20x30x1 filter) (GlasFloss ® Industries Series HV filter or equivalent is recommended) MODEL NUMBERS: MODEL SIZE (BTUH CLG.) MODEL NUMBER 18,000 19/20CDXQR R410 TXV 24,000 25/26CDXQR R410 TXV 30,000 31/32CDXQR R410 TXV 36,000 37CDXQR R410 TXV NOTES: (1) TXV's are approved for cooling or heat pump operation (2) TXV's are non-bleed type. A field installed hard start kit may be required. Catalog No. CDXQR116_UNIV (replaces cdxqr715_univ) -3-
© Copyright 2026 Paperzz