CEILING-RECESSED CASSETTE (ONE-WAY AIRFLOW) PMFY-P-NBMU-E 2. EXTERNAL DIMENSIONS..................................................................................................................................... PMFY-4 3. CENTER OF GRAVITY.......................................................................................................................................... PMFY-5 4. ELECTRICAL WIRING DIAGRAMS....................................................................................................................... PMFY-6 5. SOUND PRESSURE LEVELS............................................................................................................................... PMFY-7 5-1. Sound Pressure Levels................................................................................................................................ PMFY-7 5-2. NC Curves.................................................................................................................................................... PMFY-7 6. TEMPERATURE/AIRFLOW DISTRIBUTIONS...................................................................................................... PMFY-8 6-1. Temperature Distributions............................................................................................................................ PMFY-8 6-2. Airflow Distributions...................................................................................................................................... PMFY-8 7. OPTIONAL PARTS................................................................................................................................................. PMFY-9 7-1. External Heater Adapter CN24RELAY-KIT-CM3.......................................................................................... PMFY-9 PMFY-P-NBMU-E (Feb. 2009) PMFY-1 PMFY-P-NBMU-E 1.SPECIFICATIONS.................................................................................................................................................. PMFY-3 CEILING-RECESSED CASSETTE Cassette ceiling (1-way flow type)(ONE-WAY AIRFLOW) DATA U3 I.Cassette ceiling (1-way flow type) PMFY-P-NBMU-E PMFY-P-NBMU-E PMFY-P-NBMU-E Compact and lightweight-perfect for limited ceiling space applications. The PMFY models are one-way ceiling-recessed cassette units perfect for shallow ceiling spaces. Drain pipe max. 15-13/16” max. 23-5/8” It is designed especially for use in areas like hotel rooms that cannot support ductwork or lack sufficient space to allow for wall-mounted units. PMFY-NBMU 9-1/16” 7-25/32” Unit body body size size has has been been standardized standardized for for all all models models at at 33-5/8" 33-5/8" for for Unit ® MULTI™ easier installation. This profile is the smallest of all CITY MULTI 9-1/16"-ideal for tight location. ceiling models with a depth of only 9-1/16”-ideal Cassette ceiling Nominal cooling cap.*1 BTU/h Nominal heating cap.*2 BTU/h Ceiling unit: in. P06 P08 P12 P15 P18 P24 P27 P30 P36 P48 P54 P72 P96 0.8HP 6,000 6,700 1.0HP 8,000 9,000 1.3HP 12,000 13,500 1.6HP 15,000 17,000 2.0HP 18,000 20,000 2.5HP 24,000 27,000 2.8HP 27,000 30,000 3.2HP 30,000 34,000 4.0HP 36,000 40,000 5.0HP 48,000 54,000 5.6HP 54,000 60,000 8.0HP 72,000 80,000 10.0HP 96,000 108,000 PMFY-P-NBMU-E *1, *2 *2 are are referable referred to theSpecification Specification sheet. * Nominal conditions *1, atinthe sheet. PMFY-2 PMFY-P-NBMU-E (Feb. 2009) PMFY-P-NBMU-E IU - D - 2 1. SPECIFICATIONS External dimension H x W x D Net weight PMFY-P06NBMU-E BTU / h kW kW A BTU / h kW kW A in. mm lbs (kg) Model External finish Decoration Dimension in. panel HxWxD mm Net Weight lbs (kg) Heat exchanger Type x Quantity in.WG Pa External static pressure in.WG Pa Motor type FAN Motor output kW Driving mechanism cfm Airflow rate (Low-Mid1m3 / min Mid2-High) L/s dB <A> Sound pressure level (Low-Mid1-Mid2-High) dB <A> (measured in anechoic room) dB <A> Insulation material Air filter Protection device Refrigerant control device Connectable outdoor unit Liquid (R410A) (R22) in. (mm) Diameter of refrigerant pipe (O.D.) Gas (R410A) in. (mm) (R22) Field drain pipe size in. (mm) Drain lift mechanism in. (mm) External Drawing Wiring Refrigerant cycle Standard Document attachment Accessory Remark Indoor: Outdoor: Pipe length: Direct-driven 230-254-283-307 6.5-7.2-8.0-8.7 108-120-133-145 27-30-33-35 (208-230V) - R410A CITY MULTI 258-283-304-328 258-283-304-328 7.3-8.0-8.6-9.3 7.3-8.0-8.6-9.3 122-133-143-155 122-133-143-155 32-34-36-37 (208-230V) 32-34-36-37 (208-230V) PS foam, Polyethylene foam PP honeycomb Fuse LEV R410A CITY MULTI R410A,R22 CITY MULTI 1/4 (6.35) Flare - 1/4 (6.35) Flare - 1/4 (6.35) Flare 1/4 (6.35) Flare 1/2 (12.7) Flare O.D. 1 (26) 23-5/8 (600) 1/2 (12.7) Flare O.D. 1 (26) 23-5/8 (600) 1/2 (12.7) Flare 1/2 (12.7) Flare O.D. 1 (26) 23-5/8 (600) 272-307-343-378 7.7-8.7-9.7-10.7 128-145-162-178 33-35-37-39 (208-230V) - R410A,R22 CITY MULTI 1/4 (6.35) Flare 1/4 (6.35) Flare 1/2 (12.7) Flare 1/2 (12.7) Flare O.D. 1 (26) 23-5/8 (600) BH01C848 BH79C630 Installation Manual,Installation Book Ventilation Air: Providing sufficient ventilation air is an important part of every building design. ASHRAE standard 62 provides the minimum ventilation air requirements. Also check local codes. Installation Note: PMFY-P08NBMU-E PMFY-P12NBMU-E PMFY-P15NBMU-E 1-phase 208-230 V 60Hz 6,000 8,000 12,000 15,000 1.8 2.3 3.5 4.4 0.04 0.04 0.04 0.05 0.20 0.20 0.21 0.26 6,700 9,000 13,500 17,000 2.0 2.6 4.0 5.0 0.04 0.04 0.04 0.05 0.20 0.20 0.21 0.26 9-1/16 x 31-31/32 x 15-9/16 9-1/16 x 31-31/32 x 15-9/16 9-1/16 x 31-31/32 x 15-9/16 9-1/16 x 31-31/32 x 15-9/16 230 x 812 x 395 230 x 812 x 395 230 x 812 x 395 230 x 812 x 395 31 (14) 31 (14) 31 (14) 31 (14) PMP-16BMUW PMP-16BMUW PMP-16BMUW PMP-16BMUW 6.4Y 8.9/0.4 1-3/16 x 39-3/8 x 18-17/32 1-3/16 x 39-3/8 x 18-17/32 1-3/16 x 39-3/8 x 18-17/32 1-3/16 x 39-3/8 x 18-17/32 30 x 1,000 x 470 30 x 1,000 x 470 30 x 1,000 x 470 30 x 1,000 x 470 7(3) 7(3) 7(3) 7(3) Cross fin Line flow fan x 1 Line flow fan x 1 Line flow fan x 1 Line flow fan x 1 0.000 (208V) 0.000 (208V) 0.000 (208V) 0.000 (208V) 0 0 0 0 0.000 (230V) 0.000 (230V) 0.000 (230V) 0.000 (230V) 0 0 0 0 DC Brushless 0.028 0.028 0.028 0.028 Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation Manual. *1 Nominal cooling conditions 80degF D.B. / 67degF W.B. (26.7degC D.B. / 19.4degC W.B.) 95degF D.B. (35degC D.B.) 25 ft. (7.6 m) *2 Nominal heating conditions 70degF D.B. (21.1degC D.B.) 47degF D.B. / 43degF W.B. Unit converter kcal/h = kW x 860 BTU/h = kW x 3,412 cfm = m3/min x 35.31 (8.3degC D.B. / 6.1degC W.B.) lbs = kg / 0.4536 25 ft. (7.6 m) *Above specification data is Level difference: 0 ft. (0 m) 0 ft. (0 m) *Due to continuing improvement, above specification may be subject to change without notice. PMFY-P-NBMU-E (Feb. 2009) subject to rounding variation. PMFY-3 PMFY-P-NBMU-E Model Power source Cooling capacity *1 (Nominal) Power input Current input Heating capacity *2 (Nominal) Power input Current input External finish 6-15/16(176) 3-3/8(96) ceiling drain pan panel same line Left side outer side of grille 18-1/2(470) drain pan 31-15/16(812) 29-7/8(759) Air outlet(lower) Lower view 7-7/8(200) 7-7/8(200) 13/16(20) 2-15/18(74.5) 1-1/32(26) outer line of grille 1-3/16(30) Terminal block for remote-controller electrical box center of unit 2-1/16(53) Panel(grille):PMP-40BM 23-5/8(600) 39-3/8(1000) outer side of grille Front 2-3/16(56) 1-11/16(43) 13/16(20) 13/32(10) 7-13/16(198) 15-9/16(395) 11-7/8(302) 10(254) Drainage pipe 5-9/16(141) Refrigerant pipe(liquid) ceiling panel 3-3/8(96) Refrigerant pipe(gas) 16-15/16(430) ceiling opening 13-3/8(340) suspension bolt pitch 1-25/32(45) 1-25/32(45) 13/16(20) 9-1/16(230) 11/16(17.5) 11/16(17.5) 13/16(20) 1-13/18(46) outer side of grille 18-1/2(470) 1-9/16(40) 2-3/8(60) 9-3/8(247) 39-3/8(1000) outer side of grille 37-13-16(960) ceiling opening 31-15/18(811)suspension bolt pitch 29-7/8(759) 13/16(20) 13/16(20) Panel(grille):PMP-40BM suspension bolt(M10 or W 3/8) Fresh air intake hole 9-13/16(250) 11-3/8(288.5) Installation space required around indoor unit Terminal block for transmission Right side I.D. 1-1/32" (26) Detail drawing of ventilation air intake hole Knock out Pipe cover Liquid pipe Gas pipe Terminal block for power supply Drainage piping Refrigerant piping 4-5/16 (110) 13/16(20) 2-15/18(74.5) 1-1/32(26) 9-1/16(230) 9-1/2 (235) or more PMFY-P-NBMU-E (Feb. 2009) PMFY-P-NBMU-E mounting plate 4-5/16 (110) Top 4-1/4 (108) PMFY-4 2-11/16(69) PMFY-P-NBMU-E 2. 2. EXTERNAL EXTERNAL DIMENSIONS DIMENSIONS DATA U3 2. EXTERNAL DIMENSIONS PMFY-P06,08,12,15NBMU-E Drw. : IU-BH01C848 Unit : in(mm) IU - D - 4 3. CENTER OF GRAVITY PMFY-P06,08,12,15NBMU-E Ref.: PMFY_NBMU_COG_USDB_ALL PMFY-P-NBMU-E Pipe side A A: Center of gravity (mm)[in] Model name PMFY-P06NBMU-E PMFY-P08NBMU-E PMFY-P12NBMU-E PMFY-P15NBMU-E X 165 [6-1/2] 165 [6-1/2] 165 [6-1/2] 165 [6-1/2] Y 390 [15-3/8] 390 [15-3/8] 390 [15-3/8] 390 [15-3/8] Z 130 [5-1/8] 130 [5-1/8] 130 [5-1/8] 130 [5-1/8] PMFY-P-NBMU-E (Feb. 2009) PMFY-5 2 1 TB15 TO NEXT INDOOR UNIT PULL BOX FUSE(15A) BREAKER (15A) POWER SUPPLY ~ / N 208-230V 60Hz DC24-30V L1 L2 G TB2 MF 5 GRN / YLW RED BLU S(SHIELD) TB5 TO OUTDOOR UNIT M2 BC CONTROLLER M1 ME REMOTE CONTROLLER TO MA-REMOTE CONTROLLER DC8.7-13V BLU BLU ORN ORN (BLU) (M-NET) CN2M LED2 CN3A (BLU) LED1 6 5 4 FAN 3 (WHT) 2 1 1 2 1 2 3 I.B (WHT) DRAIN CN31 3 2 1 2 1 (BLK) GAS CN29 TH23 CND (RED) FUSE 250V 6A 2 1 LEV (WHT) LEV CN60 T MV 1 2 3 4 5 1 (GRN) VANE CN6V X1 DP 1 2 3 X1 6 5 4 3 2 1 (GRN) REMOTE INDICATION CN52 1 5 (WHT) CENTRALLY CONTROL CN51 5 6 5 4 3 2 1 6 BLU BRN ORN YLW RED WHT 3 2 1 2 1 TH21 (WHT) (RED) LIQUID INTAKE CN21 CN20 TH22 Note 1.At servicing for outdoor unit, always follow the wiring diagram of outdoor unit. 2.In case of using MA-Remote controller, please connect to TB15. (Remote controller wire is non-polar.) 3.In case of using M-NET, please connect to TB5. (Transmission line is non-polar.) 4.Symbol [S] of TB5 is the shield wire connection. 5.Symbols used in wiring diagram above are, : terminal block, :connecter. 6.The setting of the SW2, SW3 dip switches differs in the capacity for the detail, refer to the fig : 7.Please set the switch SW5 according to the power supply voltage. DS Name A.B Address board SW1 Switch Mode selection SW5 Voltage selection SW11 Address setting 1st digit SW12 Address setting 2nd digit SW14 Connection No. TH23 TH22 Symbol Thermistor TH21 BRN RED ORN YLW GRN Name Drain pump Aux.relay Transformer Power supply (I.B) Power supply (I.B) Fan motor (with inner thermo) Vane motor Drain pump kit Drain sensor Linear expansion valve Terminal Power supply Transmission block MA-Remote Controller (WHT) CNP CN25 2 1 LED2 2 1 CN27 (WHT) REMOTE SWITCH CN32 3 1 4 3 2 1 (RED) ADDRESS CN42 ON OFF P15 4 8 ON OFF P12 (RED) ADDRESS CN81 ON OFF P08 8 7 6 5 4 3 2 1 ON OFF P06 Models Power supply for MA-Remote controller LED1 Main power supply LED on indoor board for service Mark Meaning ON OFF SW4 SW3 SW2 Symbol X1 T LED1 LED2 MF MV DP DS LEV TB2 TB5 TB15 (RED) ADDRESS CN43 0 0 0 (RED) ADDRESS CN82 1 2 3 4 5 6 7 8 910 1 2 3 4 5 6 7 8 910 1 2 3 4 5 6 7 8 910 1 2 3 4 5 6 7 8 910 SW3 8 7 6 5 4 3 2 1 ON OFF ON OFF ON OFF ON OFF 4 3 2 1 A.B 123456 123456 123456 123456 SW2 Function 230V Name Indoor controller board Connector Humidifier Damper Remote switch Centrally control Remote Indication Switch Capacity code Mode selection Model selection Varistor Fuse (6A / 250V) SW5 Symbol I.B CN25 CN27 CN32 CN51 CN52 SW2 SW3 SW4 ZNR FUSE SW1 1 2 34 5 1 2 3 4 5 6 1 2 3 4 5 6 7 8 910 ON OFF SWC SW14 SW12 SW11 [Legend] 1 2 3 4 5 6 7 8 910 ON OFF CONNECTION No. PMFY-P-NBMU-E (Feb. 2009) PMFY-P-NBMU-E 1ST DIGIT PMFY-6 3RD 2ND DIGIT DIGIT PMFY-P06,08,12,15NBMU-E 208V PMFY-P-NBMU-E 4. 3. ELECTRICAL ELECTRICAL WIRING WIRING DIAGRAMS DIAGRAMS DATA U3 3. ELECTRICAL WIRING DIAGRAMS Drw. : IU-BH79C630 IU - D - 5 5. 4. SOUND SOUND PRESSURE PRESSURE LEVELS LEVELS DATA U3 4-1. Sound Levels 5-1. SoundPressure Pressure Levels 4. SOUND LEVELS UNIT Operating sound pressure levels (Low-Medium2-Medium1-High) CEILING Model 4-7/ 8 ft (1.5m) PMFY-P-NBMU-E Cassette ceiling series Unit : dB(A) Sound pressure levels (A weighted) PMFY-P06NBMU-E 27-30-33-35 PMFY-P08NBMU-E 32-34-36-37 PMFY-P12NBMU-E 32-34-36-37 PMFY-P15NBMU-E 33-35-37-39 MICROPHONE Measurement location 4-2. NC 5-2. NCcurves Curves PMFY-P06NBMU-E PMFY-P08,12NBMU-E PMFY-P15NBMU-E External Static Pressure: 0Pa Power Source: 208-230V, 60Hz External Static Pressure: 0Pa Power Source: 208-230V, 60Hz External Static Pressure: 0Pa Power Source: 208-230V, 60Hz 70.0 High Low Middle1 Middle2 65.0 60.0 70.0 60Hz 60Hz 60Hz 60Hz NC-60 55.0 50.0 NC-50 45.0 40.0 NC-40 35.0 30.0 NC-30 25.0 20.0 15.0 10.0 High Low Middle1 Middle2 65.0 60.0 70.0 60Hz 60Hz 60Hz 60Hz NC-60 55.0 50.0 NC-50 45.0 40.0 NC-40 35.0 30.0 NC-30 25.0 20.0 Approximate minimum audible limit on continuous noise 63 125 250 NC-20 500 1k 2k 4k 8k Octave band center frequencies <Hz> Ref.:NC_PMFY-P06NBMU-E 15.0 10.0 High Low Middle1 Middle2 65.0 60.0 60Hz 60Hz 60Hz 60Hz NC-60 55.0 50.0 NC-50 45.0 40.0 NC-40 35.0 30.0 NC-30 25.0 20.0 Approximate minimum audible limit on continuous noise 63 125 250 NC-20 500 1k 2k 4k 8k 15.0 10.0 Approximate minimum audible limit on continuous noise 63 Octave band center frequencies <Hz> Ref.:NC_PMFY-P08,12NBMU-E PMFY-P-NBMU-E (Feb. 2009) PMFY-P-NBMU-E 125 250 NC-20 500 1k 2k 4k 8k Octave band center frequencies <Hz> Ref.:NC_PMFY-P15NBMU-E IUPMFY-7 -D-6 6. TEMPERATURE/AIRFLOW DISTRIBUTIONS 6. TEMPERATURE/AIRFLOW DISTRIBUTIONS DATA U3 6-1. Distributions 6-1. Temperature Temperature distributions <Cooling mode> ° <Heating mode> ° 2.7 2.7 (8' 10-5/16") 19(66) 2 (6' 6-3/4") Height <m(ft)> Height <m(ft)> (8' 10-5/16") 21(70) 23(73) 25(77) 1 (3' 3-3/8") 23(73) 25(77) 2 (6' 6-3/4") 33 (91) 24(75) 1 (3' 3-3/8") 27 (81) 30 (86) 24(75) 21(70) 25(77) 5 (16' 4-7/8") 4 (13' 1-1/2") 3 (9' 10-1/8") 2 (6' 6-3/4") Floor distance <m(ft)> 6-2. Airflow Airflow distributions 6-2. Distributions 1 (3' 3-3/8") 5 (16' 4-7/8") 0 4 (13' 1-1/2") 3 (9' 10-1/8") 2 (6' 6-3/4") Floor distance <m(ft)> Ref.:TD_PMFY-P-NBMU-E_C30 0 <Fan mode> m/s(ft/s) m/s(ft/s) 2.7 (8' 10-5/16") 2.7 (8' 10-5/16") 2 (6' 6-3/4") Height <m(ft)> 3.0(9' 10-1/8") 2.0(6' 6-3/4") 1.0(3' 3-3/8") 1 (3' 3-3/8") 0.5(1' 7-11/16") 3.0(9' 10-1/8") 2 (6' 6-3/4") 2.0(6' 6-3/4") 1 (3' 3-3/8") 0.5(1' 7-11/16") 5 (16' 4-7/8") 4 (13' 1-1/2") 3 (9' 10-1/8") 2 (6' 6-3/4") Floor distance <m(ft)> 1 (3' 3-3/8") 0 Ref.:AD_PMFY-P-NBMU-E_30 PMFY-8 1 (3' 3-3/8") Ref.:TD_PMFY-P-NBMU-E_H70 <Fan mode> Height <m(ft)> PMFY-P-NBMU-E 6. TEMPERATURE/AIRFLOW DISTRIBUTIONS PMFY-P-NBMU-E (Feb. 2009) PMFY-P-NBMU-E 5 (16' 4-7/8") 4 (13' 1-1/2") 3 (9' 10-1/8") 1.0 (3' 3-3/8") 0.5(1' 7-11/16") 2 (6' 6-3/4") Floor distance <m(ft)> 1 (3' 3-3/8") 0 Ref.:AD_PMFY-P-NBMU-E_70 IU - D - 25 7. OPTIONAL PARTS 7-1. External Heater Adapter CN24RELAY-KIT-CM3 PMFY-P-NBMU-E External heater adaptor CN24RELAY-KIT-CM3 is a set of special wiring parts for controlling the electric heater* with the air conditioner system. *The electric heater should be designed and prepared at the site. A basic connection method is shown as follows:(For details, refer to its Installation Manual.) Remote control Board Relay circuit Indoor unit control board Adapter X Red 1 White 2 White Electric Heater power source CN24 Outdoor unit control board PUHY,PURY-P-TGMU SW5-2 "ON" PUHY,PURY-P-T/YHMU SW5-10 "ON" PUMY series SW4-4 "ON" PUHY,PURY-P-T/YJMU SW5-10 "ON" PUHY,PURY-HP-TJMU SW5-10 "ON" X Electric Heater Maximum cable length is 10 m (32ft) Preparations in the field For relay X use the specifications given below Operation coil Rated voltage : 12VDC Power consumption : 0.9W or less The length of the electrical wiring for the CN24RELAY-KIT-CM3 is 2 meters (6-1/2 ft) To extend this length, use sheathed 2-core cable. Control cable type : CVV, CVS, CPEV or equivalent. Cable size : 0.5 mm2 ~ 1.25 mm2 (16 to 22 AWG) Don't extend the cable more than 10 meters (32ft) Recommended circuit R 1-phase power supply Wiring diagram S 208V, 230V/60Hz R 88H FS1 H1 88H FS2 FS1 H2 S FS1, 2 ----- Thermal fuse FS2 88H Control board 26H H1, H2 ----- Heater 26H --------- Overheat protection thermostat 88H --------- Electromagnetic contactor CN24 Item Quantity External output cable 2 Fan speed setting cable with resistance 2 Shape Refer to the Installation Manual for wiring and installation details. PMFY-P-NBMU-E (Feb. 2009) PMFY-9 PMFY-P-NBMU-E PMFY-10 PMFY-P-NBMU-E (Feb. 2009)
© Copyright 2026 Paperzz