MODEL FD-A STATIC CURTAIN TYPE FIRE DAMPERS HORIZONTAL AND VERTICAL / 11/2 or 3 HOUR LISTED AND LABELLED BY: FD-VA L A E AL AT S Galv. Steel Interlocking Blades Fusible Link (Replaceable) 165°F Standard D am per = N om inal - 1/4" (6 m m ) E CALIF O OF NI 11 3 /16" (94 mm) S TIN G R S TA T LI ST FIR ER E MAR S VIC E DESIGNED AND TESTED IN ACCORDANCE WITH UL-555 AND ULC-S112. MEETS ALL NFPA-90A REQUIREMENTS FOR FIRE DAMPERS. Galv. Steel Frame FD-HA Stainless Steel Closure Spring Access Door Located This Side 11 3 /16" (94 mm) Frame: Roll Formed Galvanized Steel with Safety Edge. Blades: Roll Formed Galvanized Steel, Curtain-Type Springs: Stainless Steel. Fusible Link: U.L. Listed 165°F. 1-1/2 Hr. Vertical Min. Size: 4”w X 4”h (102 mm x 102 mm) Max. Size: 120”w X 120”h (3048 mm x 3048 mm) Single Section Max: 60”w X 60”h (1524 mm x 1524 mm) 1-1/2 Hr. Horizontal Min. Size: 4”w X 4”h (102 mm x 102 mm) Max. Size: 120”w X 40”h (3048 mm x 1016 mm) or 96”w X 48”h (2438 mm x 1219 mm) Single Section Size: 48”w X 48”h (1219 mm x 1219 mm) 3 Hr. Vertical Min. Size: 4”w X 4”h (102 mm x 102 mm) Max. Size: 80”w X 40”h (2032 mm x 1016 mm) Single Section Size: 40”w X 40”h (1016 mm x 1016 mm) 3 Hr. Horizontal Min. Size: 4”w X 4”h (102 mm x 102 mm) Max. Size: 80”w X 40”h (2032 mm x 1016 mm) Single Section Size: 40”w X 40”h (1016 mm x 1016 mm) H Standard Construction: FD-(V/H) AR Optional Construction: Factory Supplied Sleeve 18 - 16 - 14 - 10 Gauge Sleeve Length (Required) D* D+2" FD-A - 09-08 3 Hour Rating Round Transitions (FD - AR) Fuse Link 212°F * D = Duct Size Minus 1/4” * Maximum Diameter = 58” (1473 mm) Notes: Non-sleeved Dampers are furnished approximately 1/4” (6.4mm) smaller than given duct dimensions. Sleeved Dampers are furnished approximately same size as given duct dimensions, unless otherwise noted. “These Dampers are UL/ULC Approved For Use in Static Systems Where The Fan Shuts Down D+2" Manufacturer’s Recommendations All moving parts of the damper must be inspected and cycled at intervals not greater than 6-12 months the first year and then every 4 years after, or in accordance with the latest edition of NFPA 90A, 92A, local codes and the actuator manufacturer. In addition, fuse links shall be removed and inspected for corrosion. Dry lubricants are recommended. Specifications are correct at time of printing. However, as part of our ‘continuous improvement program,’ we reserve the right to make further improvements without notice. Project: Contractor: Location: Address: Architect: P.O. Number: Engineer: NCA MANUFACTURING, Date: INC. 1036 SOUTH JUPITER ROAD GARLAND, TEXAS 75042 TEL. 972-276-5002 FAX 972-276-6747
© Copyright 2025 Paperzz