Product Group 11

X-Ray, Exposure
PG 11
Article-No. Description
11
11
11
11
11
10500
10501
10504
10507
10510
Engraved Markers
Set of Letters A - Z
Set of Numbers 0 - 9
Height
4 mm
Heigth
7.5 mm
Height
10 mm
Made of yellow. non-breakable plastic, only 2 –2.5 mm thick.
A tungsten putty is embedded permanently into the engraved
outlines of the symbol. The upper edge has a slot worked
in (0.4 mm) to accept the carrier strip.
Following symbols are available in three different
character heights: Numbers 0-9, letters A-Z, stop,
oblique, hyphen, multiplication sign, arrows.
11 10511
Arrow marker
slotted on four sides, may be lined up
to point in four different directions.
11 11502
Firms name or symbol,
per piece there will be a tool charge for customers
own design of name or symbol
11 11510
Carrier strip for engraved markers
In flexible plastic 20 x 500 mm, thickness will fit
into slots of markers.
11 11610
Carrier strip, magnetic
In flexible plastic combined 0.1 - 0.5 m length
11 11520
Clasp for engraved marker
Clasp for 10 engraved markers, 7.5 mm, the clasp
may be mounted on a marker type between decimals.
11 11997
Metal Box; 36 Divisions
For storing exposure accessories in two tiers
Size: 340 x 245 x 70 mm, 2.1 kg
11 10650
Complete Set for Film Marking
Consisting of:
1x Box for engraved markers ( 11997 )
100x Engraved numbers, ten each 0 - 9
78x Engraved letters, three each A - Z
25x Engraved signs, 5 each hyphen, multiply, arrow up
5x Arrows slotted on four sides
2x Magnets for IQI´s and markers (11021)
2x Carrier strips 0.5 m (11510)
5x Carrier strips magnet (11610)
3x Metal clasps for markers (11520)
Size
Weight
: 340 x 245 x 70 cm
: 2,6 kg
Page 1
X-Ray, Exposure
PG 11
Article-No. Description
11
11
11
11
11
11
10100
10101
10106
10108
10110
10113
Lead Marker, Cast
Set of Letters A - Z
Set of Numbers 0 - 9
Height
6 mm
Heigth
8 mm
Height
10 mm
Height
13 mm
Letters, numbers and arrows conical character
size measured front, per piece
11 10997
Box for Cast Markers, Wood
Fitted with 48 compartment
Size: 400 x 300 x 75 mm, 950 g
11 10161
Marking Tape for Press Ident
Rolls of self adhesive tape with lead lining
for the quick production of identification-marking
strips for radiography.
1 roll, ca. 2 m long, width of tape 12 mm
11 10855
Zero-Punch Steel
Stamps zero and arrow into steel by impact,
symbol 6 mm high. To indicate date line and
eventual direction of product flow through a pipeline.
No sharp edges.
11 10800
NISSEN Marking Paint
Tube dispenser with ball point valve gives
permanent white lines 3.2 mm wide. Specimens
will keep their markings up to 950° C. Nor trace
of sulphur or chlorides. Weight: 130 g
11 10850
Marking Crayon, Yellow
Weatherproof and wipe proof. 12 pcs. in a box
11 10950
Stop Watch
To control exposure times 360° C circle for
15 minutes and small round 30 seconds..
Size: 60 mm ø x 20 mm, 150 g
11 10960
Countdown Timer
Digital countdown timer with alarm.
Accepts any setting of time spans
between 1 second to 99.99 minutes.
Clips on to pocket or may stand on desk.
Size: 70 x 60 x 20 mm, 50 g
Page 2
X-Ray, Exposure
PG 11
Article-No. Description
11
11
11
11
10911
10912
10913
10914
Lead Marker Tape
Spaced at 25 cm per 10 cm
Spaced at 20 cm per 10 cm
Spaced at 10 cm per 10 cm
Spaced at 5 cm per 10 cm
Lead numbers built into a double sided thick hardwearing cloth tape
measure; with a plastic buckle. Available in any length.
Priced in multiples of 10 cm
11
11
11
11
11
10921
10922
10923
10924
10925
11 10490
11 10491
11 10492
11 10493
Dispensing Reel for Marker Tapes
for marker tapes up to 3 m length
for marker tapes up to 6 m length
for marker tapes up to 12 m length
for marker tapes up to 15 m length
for marker tapes up to 20 m length.
Lead Marker Tape for Co-60 Radiography
For heavy wall thickness to 130 mm FE.
Marked every 10 cm with one or two lead markers
16 mm high an 2-3 mm thick. Available in lengths
from 1 m upwards, priced in multiples of 10 cm length.
Lead Marker Tape Narrow
Spaced at 5 cm per 10 cm
Spaced at 2 cm per 10 cm
Spaced at 1 cm per 10 cm
With a GRP tape only 9 mm. Built in cloth tape with
visible cm divisions. Every 1, 2, or 5 cm a built-in lead
figure 4 mm high. Available in lengths to 1.5 m,
priced in multiples of 10 cm length
11 11950
11 11951
Textile rubber belt
Standard length 1.5 m.
per each additional meter
For securing cassettes and readypack films to
circumferential welds. 19 mm wide with a buckle,
11 10141
11 10142
Film Fastening Tape, Roll 50 m Long
Black, 50 mm wide
Black, 25 mm wide
Strong cloth tape for fastening films or cassettes
up to 50° C. May be torn both along and across the roll.
11 11310
11 11350
Magnetic Wallets for EN Wire IQIs
for EN wire IQI´s, 25 mm long
for EN wire IQI´s, 50 mm long
Page 3
X-Ray, Exposure
PG 11
Article-No. Description
11 11010
11 11020
Film Marking Frames
for film areas to 10 x 48 cm
for film areas to 10 x 24 cm
Flexible steel frames with magnets on four
corners for positioning engraved markers and
wire type penetrameters on test specimens.
11 11021
Magnet for IQI´s
Ø 20 mm, 40 x 30 x 25 mm, 110 g
11 11050
Brigde type clamping magnet
With 2 permanent magnets and a flexible bridge.
Distance between magnets is 160 mm.
Size: 21 x 35 x 240 mm, 220 g
11 11210
Magnetic film cassette and holder
With 2 routable horse-shoe magnets and a spring-loaded
pressure cup for holding films and cassettes up to 10 cm wide.
Distance between the magnets: 130 mm.
Size: : 220 x 30 x 110 mm, 820 g
11 11211
Suction pad holder
For non magnetic surfaces. Spring loaded pressure cup.
Distance between the two suction pads is 130 mm.
Size: 210 x 30 x 110 mm, 500 g
11
11
11
11
11
11
11
11
11
11
12710
12718
12711
12719
12720
12722
12725
12727
12728
12729
Anti-scatter filter Pb
10 x 24 cm, Pb 0.5 mm
10 x 40 cm, Pb 0.5 mm
10 x 48 cm, Pb 0.5 mm
15 x 40 cm, Pb 0.5 mm
30 x 40 cm, Pb 0.5 mm
10 x 24 cm, Pb 1.0 mm
10 x 40 cm, Pb 1.0 mm
10 x 48 cm, Pb 1.0 mm
15 x 40 cm, Pb 1.0 mm
30 x 40 cm, Pb 1.0 mm
To keep scattered radiation away from the rear of the X-Ray film.
Sealed in a welded polythene wallet.
11
11
11
11
12810
12811
12820
12830
Anti-Scatter filter Sn
10 x 24 cm, Sn 0.5 mm
10 x 48 cm, Sn 0.5 mm
30 x 40 cm, Sn 0.5 mm
30 x 40 cm, Sn 1.0 mm
Page 4
X-Ray, Exposure
PG 11
Article-No. Description
System for attaching C P tube-heads
For fixing CO tube heads on pipes eg. MCN 101, 160, 165, 166,
167, 225 or other tube heads diam. 70, 100 or 120 mm.
The five available modular PE elements may
be fitted with hooks or clips to join 2 - 3 elements together
11 11090
11 11091
11 11092
Basic and double wall element
Basic element for Heads 100 mm Ø
Basic element for Heads 70 mm Ø
Basic element for Heads 120 mm Ø
The concave surface maybe fastened to
tube housing with two metal straps 25 mm
wide. The prismatic surface fastens to pipe
under test with pipe strap, Code 11105, for
double wall exposures. May also be fixed
to the spacers Code 11095 or 11100.
Size: 100 x 180 x 60 mm, 700 g
11 11095
Spacer for 350 mm FFD
Upper surface formed to take prismatic
surface of basic element. Lower prismatic
surface may be fastened to pipe under test
with the pipe strap, Code 11105. Together
with a basic element the FFD will be appr. 350 mm.
Size: 100 x 180 x 275 mm, 2.1 kg
11 11100
Spacer for loop shot position
The lower prismatic surface may be fastened
to pipe under test with pipe strap. The upper
surface is angled at 30 degrees to take
prismatic surface of basic plates, and is fitted
with 4 clips for quick coupling. Together with
the right basic element the FFD will be fine
for loop shots of welds in small pipes.
Size: 100 x 155 x 165 mm, 1.7 kg
11 11105
X-Ray pipe strap with ratchet
For the safe and quick fastening of X-Ray tube
heads, basic elements or spacer elements
to pipes.
Length of strap:
4m
Width of strap:
36 mm
Size:
160 x 80 x 70 mm
Weight:
0.65 kg
Page 5
X-Ray, Exposure
PG 11
Article-No. Description
IQI acc. to EN 462-2; Step / Hole
11
11
11
11
11
11
11
11
11
11
11
11
00114
00113
00112
00111
00124
00123
00122
00134
00133
00132
00144
00143
Description
for Image Quality
IQI EN 462-H 1-FE
IQI EN 462-H 5-FE
IQI EN 462-H 9-FE
IQI EN 462-H13-FE
IQI EN 462-H 1-CU
IQI EN 462-H 5-CU
IQI EN 462-H 9-CU
IQI EN 462-H 1-AL
IQI EN 462-H 5-AL
IQI EN 462-H 9-AL
IQI EN 462-H 1-TI
BPK EN 462-H 5-TI
H 1 to H 6
H 5 to H 10
H 9 to H 14
H13 to H 18
H 1 to H 6
H 5 to H 10
H 9 to H 14
H 1 to H 6
H 5 to H 10
H 9 to H 14
H 1 to H 6
H 5 to H 10
These IQIs consist of six steps with one or two holes of the same
diameter as the thickness. The individual plaques are welded into a PVC
pouch which also contains the lead identification. Each IQI is
numbered and is supplied with a declaration of conformity within a
storage wallet.
11 00151
Image Quality Indicator acc. to EN 462-5
For measuring image unsharpness. The IQI consists of 13 wire pairs
embedded in rigid plastic. The wires of platinium and tungsten and
are exactly spaced to correspond to the diameter of each pair.
Each IQI is engraved with a serial number and is supplied with
a declaration of conformity in a storage box
11 00750
ASTM 801 -91 Penetrameter
According to ASTM E 801 they consist of a set of 8 IQI´s
about radiographically equivalent to diodes,
PCB´s or larger hybrid circuit devices. Each IQI consists
of a number of wires, which vary in diameter and are
arranged on a shim in a grid pattern. Next to them
are lead particles of different sizes and an identification number.
Complete set in storage box
Page 6
X-Ray, Exposure
PG 11
Article-No. Description
Penetrameter acc. to ASTM E-1025-98
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
00671
00672
00673
00674
00675
00676
00677
00678
00679
00680
00681
00682
00683
00684
00685
00686
00687
00688
00689
Type
Thickness in mm and inch
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
6,3 mm
9,5 mm
12,7 mm
15,9 mm
19,1 mm
22,2 mm
25,4 mm
31,8 mm
38,1 mm
50,8 mm
63,5 mm
76,2 mm
101,6 mm
152,4 mm
203,2 mm
254,0 mm
304,8 mm
406,4 mm
508,0 mm
5
7
10
12
15
17
20
25
30
35
40
45
50
60
80
100
120
160
200
(((((((((((((((((((-
1/4“)
3/8“)
1/2“)
5/8“)
3/4“)
7/8“)
1“
)
1 1/4“)
1 1/2“)
2“
)
2 1/2“)
3“
)
4“
)
6“
)
8“
)
10“
)
12“
)
16“
)
20“
)
These conform to the American standards, ASTM-E 142,
ASME-section III(post 1973) ASME-section V, API 1104.
They have three holes 1 x. 2 x and 4 x the penetrameter thickness,
with minimum diameters of 0.01“, 0.02“ and 0.04“. Therefore the hole
diameters only differ in size from No. 12 upwards. The numbers tell
the thickness of the shim in thousands of an inch. The stainless material
may be used on mild steel an vice versa.
11 13810
Exposure Calculator, Ir-192
For calculating gamma exposure with Ir-192,
constant for film D5 and density 3.5, in an
easy slide rule design. Supplied in a leather wallet.
Size: 55 x 170 x 2 mm, 20 g
11 13850
Exposure Calculator, Universal
For calculating exposures with Ir-192, Co-60,
Cs-137 and Th-170.
For all films and film densities with an easy to
work slide rule design. On the back a thickness
conversion scale gives the steel equivalent for
a number of frequently encountered materials.
Complete with instructions, film speed tables
and a leather wallet. All source to film distance
are given in metric units.
Size: : 65 x 185 x 12 mm, 80 g
Page 7
X-Ray, Exposure
PG 11
Article-No. Description
11
11
11
11
00711
00712
00713
00714
ASTM E 747-98 Wire IQI
Typ 1 A 01 FE Mat. thickness
4- 12,5
Typ 1 B 03 FE Mat. thickness 10- 40,5
Typ 1 C 10 FE Mat. thickness 32-125
Typ 1 D 32 FE Mat. thickness 102-400
mm
mm
mm
mm
11 00721
11 00722
11 00723
Typ 02 A 01 AL Mat. thickness
Typ 02 B 03 AL Mat. thickness
Typ 02 C 10 AL Mat. thickness
4- 12,5 mm
10- 40,5 mm
32-125 mm
11 00731
11 00732
11 00733
Typ 4 A 01 CU Mat. thickness 4- 12,5 mm
Typ 4 B 03 CU Mat. thickness 10- 40,5 mm
Typ 4 C 10 CU Mat. thickness 32 -125 mm
11 00741
11 00742
Typ 01 A 01 TI Mat. thickness 4- 12,5 mm
Typ 01 B 03 TI Mat. thickness 10- 40,5 mm
Each IQI consists of 6 wires differing in
diameter and a lead identification.
With declaration of conformity.
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
00871
00872
00873
00874
00875
00876
00877
00878
00879
00880
00881
00882
00883
00884
00885
ASTM Penetrameter acc. to E 1742 (form. MIL-STD 453)
Type
Penetrameter
Min. thickness
number
thickness (")
specimen mm / inch
0.25
0.005
6,35
1/4
0.37
0.0075
9,53
3/8
0.50
0.01
12,7
1/2
0.62
0.0125
15,87
5/8
0.75
0.015
19,05
3/4
0.87
0.0175
22,22
7/8
1.0
0.02
25,4
1
1.2
0.025
31,75
1 1/4
1.5
0.03
37,5
1 1/2
1.7
0.035
44,45
1 3/4
2.0
0.04
50,8
2
2.2
0.045
57,15
2 1/4
2.5
0.05
63,5
2 1/2
3.0
0.06
76,2
3
4.0
0.08
101,6
4
These Penetrameters are very similar to the other
ASTM/ASME variety and follow the same hole to
thickness pattern whit three holes. The number on
a ASTM E 1742 penetrameter refers to the minimum
specimen thickness at 2 % sensitivity. Therefore the
number is 50x the penetrameter thickness. Fractions
of an inch in the identifying number are expressed
as decimals.
Page 8
X-Ray, Exposure
PG 11
Article-No. Description
11
11
11
11
11
11
11
11
11
00411
00412
00414
00413
00415
00416
00441
00442
00443
EN 462-1 Image Quality Indicator
IQI EN 462- W 1 FE, 50 mm
IQI EN 462- W 6 FE, 50 mm
IQI EN 462- W 6 FE, 25 mm
IQI EN 462- W10 FE, 50 mm
IQI EN 462- W10 FE, 25 mm
IQI EN 462- W10 FE, 10 mm
IQI EN 462- W13 FE, 50 mm
IQI EN 462- W13 FE, 25 mm
IQI EN 462- W13 FE, 10 mm
11
11
11
11
11
11
11
11
11
00421
00422
00424
00423
00425
00426
00461
00462
00463
IQI
IQI
IQI
IQI
IQI
IQI
IQI
IQI
IQI
EN
EN
EN
EN
EN
EN
EN
EN
EN
462462462462462462462462462-
W 1 AL, 50 mm
W 6 AL, 50 mm
W 6 AL, 25 mm
W10 AL, 50 mm
W10 AL, 25 mm
W10 AL, 10 mm
W13 AL, 50 mm
W13 AL, 25 mm
W13 AL, 10 mm
11
11
11
11
11
11
11
00431
00432
00434
00433
00435
00436
00481
IQI
IQI
IQI
IQI
IQI
IQI
IQI
EN
EN
EN
EN
EN
EN
EN
462462462462462462462-
W 1 CU, 50 mm
W 6 CU, 50 mm
W 6 CU, 25 mm
W10 CU, 50 mm
W10 CU, 25 mm
W10 CU, 10 mm
W13 CU, 50 mm
11
11
11
11
00493
00495
00497
00498
IQI
IQI
IQI
IQI
EN
EN
EN
EN
462462462462-
W10
W10
W13
W13
TI,
TI,
TI,
TI,
50
25
50
25
mm
mm
mm
mm
Wire type penetrameters, acc. to the European standard EN 462,
1994 issue. Number, arrangement, radius and material of each
wire in this IQI correspond to the previous known DIN Image Quality
Indicators (IQI) acc. to 54109, 1987 issue.
Enclosed is certification of conformity for each BPK
and the radiographic inscription at the top e.g. 10 FE EN.
The letter "W" stand for "Wire". The thickest wire and with
it the lowest Image Quality Class is W1.
Page 9
X-Ray, Exposure
PG 11
Article-No. Description
EN Image Quality Indicators
Acc. the European Standard EN 462, 1994 issue.
Mounted in a transparent plastic pocket with one
line of identification markers.The IQIs are fully
comply with the internatinal standard
ISO 1027-83. The available types vary acc. to the
sequence of the seven parallelly embedded wires
(1, 6, 10 ,13) - as their numbers goes up, their
diameter goes down. They vary in material
(FE, AL, CU, TI) and in the length of wires
(50, 25, 10 mm).
Number and diameter of wires:
1 FE EN
6 FE EN
10 FE EN
13 FE EN
as
as
as
as
before
before
before
before
FE
FE
FE
FE
1- 7
6 - 12
10 - 16
13 - 16
Material of wires:
Type
Meterial
For radiograhpy of specimen made of
FE
AL
CU
TI
clear steel
aluminium
copper
titanium
iron, stainless & alloys
aluminium, magnesium & alloys
copper, zink, tin & alloys
titanium
Four sequences of 7 wires each are available,
their choice depending on specimen thickness:
Seq. Code
No. Of wire
For specimen thickness
mm
inches
1
6
10
13
1- 7
6 - 12
10 - 16
13 - 19
160 - 40
50 - 12.5
20 - 5
10 - 2.5
6.3 - 1.575
1.97 - 0.49
0.78 - 0.2
0.39 - 0.1
The letter "W" stand for "Wire". The thickest wire and with
it the lowest Image Quality Class is W1.
Page 10