AX1 ICON KEYPAD Installer Programming Sheet

ASSURE D LI VE SAFE
AX1 ICON KEYPAD Installer Programming Sheet
Ver 1.0
Default Setting
ICON
Display
CL
Item
Description
Zone LED
1234 5678 9
01#
Installer Code
5 digits installer code
12345#
INS CD
Telephony Setting
10#
Telephony Control
Zone 1 LED ON mean enable DTMF Dialling else Pulse Dialling
Zone 2 LED ON mean enable Double Call
XX XXXX X #
TEL CT
11#
Receiver Type
Zone 1 LED ON mean Receiver 1 as User else CMS
Zone 2 LED ON mean Receiver 2 as User else CMS
Zone 3 LED ON mean Receiver 3 as User else CMS
Zone 4 LED ON mean Receiver 4 as User else CMS
XXXX X #
RCR TY
12#
Receiver Option
Zone 1 LED ON mean Receiver 1 as Permanent else Backup
Zone 2 LED ON mean Receiver 2 as Permanent else Backup
Zone 3 LED ON mean Receiver 3 as Permanent else Backup
Zone 4 LED ON mean Receiver 4 as Permanent else Backup
XXXX X #
RCR OP
13#
Delay before Dial
Timer
From 0 – 15 seconds
0#
DELAY
14#
Dial Attempts
From 0 – 15 Times
5#
DL APT
15#
Redial Timer
From 0 – 10 Times
0#
REDIAL
16#
CMS Account No 1
4 digits CMS account number 1
0000#
ACC1
17#
CMS Account No 2
4 digits CMS account number 2
0000#
ACC2
18#
CMS Account No 3
4 digits CMS account number 3
0000#
ACC3
19#
CMS Account No 4
4 digits CMS account number 4
0000#
ACC4
20#
Telephone No 1
Max 18 digits telephone number 1 (0 to erase telephone number)
#
TEL 1
21#
Telephone No 2
Max 18 digits telephone number 2 (0 to erase telephone number)
#
TEL 2
22#
Telephone No 3
Max 18 digits telephone number 3 (0 to erase telephone number)
#
TEL 3
23#
Telephone No 4
Max 18 digits telephone number 4 (0 to erase telephone number)
#
TEL 4
24#
Ring Number
From 1 – 99 rings
10#
RI NUM
X
(Press for next zone
DELAY
Zone Type Setting (Zone 1 – Zone 8)
30#
Delay Zone
Zone LED ON means the zone is assigned as Delay zone
Instant Zone
Zone LED ON means the zone is assigned as Instant zone
X
INST
Interior Zone
Zone LED ON means the zone is assigned as interior zone
X
INTER
24 Hours Zone
Zone LED ON means the zone is assigned as 24 Hour zone
X
24 HR
Light Zone
Zone LED ON means the zone is assigned as Light zone
X#
LIGHT
NO
type or # to save)
Zone Circuit Type (Zone 1 – Zone 8)
31#
Normally Open
Zone LED ON means the zone is assigned to N.O type
X
(Press for next zone
Normally Close
Zone LED ON means the zone is assigned to N.C type
X
NC
EOL
Zone LED ON means the zone is assigned to E.O.L type
X#
EOL
type or # to save)
Zone Sensitivity Setting (Zone 1- Zone 8)
32#
Select Zone
From 1 - 8
#
ZNNUM
Sensitivity
From [1 – 100] *10ms
20#
SENS
Zone Bell Type (Zone 1 – Zone 8)
33#
Select Zone
From 1 – 8
#
ZNNUM
Bell type
[1] Pulse, [2] Steady, [3] Chirp, [4] Silent
2#
BELL
Zone Door Chime (Zone 1 – Zone 8)
34#
Select Zone
From 1 – 8
#
ZNNUM
Door Chime
Zone 1 LED ON mean Chime Enable else Disable
XXX XXXX X #
CHIM
Zone Bypass Allow (Zone 1 – Zone 8)
Select Zone
From 1 – 8
#
ZNNUM
Bypass Allow
Zone 1 LED ON mean Allow to Bypass else Not Allow
XXX XXXX X #
BYPS
36#
Entry Delay
From 10 – 150 seconds
30#
ENTRY
37#
Exit Delay
From 10 – 150 seconds
60#
EXIT
38#
Bell Audible Time
From 1 – 30 minutes or 0 for continuous
5#
BELL
35#
1
39#
Tamper Zone
Setting
Zone 1 LED ON means Active 24 Hours else Active when ARM
Zone 2 LED ON means NC type else NO type
XX XXXX X #
TAMPER
Zone reporting (Zone 1 – Zone 8)
40#
Select Zone
From 1-8
#
ZNNUM
Zone Reporting
Zone 1 LED ON means enable Alarm reporting
Zone 2 LED ON means enable Alarm Restore Reporting
Zone 3 LED ON means enable Bypass & Bypass Restore Reporting
X XXXX X #
ZNRPT
Telephony Reporting
41#
CMS Periodic report
From 1 – 24 Hours
#
PERIOD
42#
System Report
Zone 1 LED ON means enable Keypad Alarm Reporting
Zone 2 LED ON means enable System Status Reporting
Zone 3 LED ON means enable Open Report
Zone 4 LED ON means enable Close report
Zone 5 LED ON means enable System Reset Report
Zone 6 LED ON means enable CMS Periodic Report
XX X #
SYSRPT
3#
KEYSET
Key switch Setting
43#
Keyswitch Type
[1]
[2]
[3]
[4]
Keyswitch Latch with bell indicator
Keyswitch Latch with Strobe Light indicator
Keyswitch Momentary with bell indicator
Keyswitch Momentary with Strobe Light indicator
44#
Keyswitch circuit
ZONE 1 LED ON means NC type else NO type
XXX XXXX X #
KEYTYP
Softzone Bell Setting
50#
Fire
[1] Pulse, [2] Steady, [3] Chirp, [4] Silent
2#
FIRE
51#
Emergency
[1] Pulse, [2] Steady, [3] Chirp, [4] Silent
2#
EMRGCY
52#
Panic
[1] Pulse, [2] Steady, [3] Chirp, [4] Silent
2#
PANIC
60#
Unit control
Zone 1 LED ON means enable Phone communication
Zone 2 LED ON means enable Battery Test
Zone 3 LED ON means enable Softzone
Zone 4 LED not in use
Zone 5 LED ON means enable Keyswitch
Zone 6 LED ON means enable 4 min Power Up delay
Zone 7 LED ON means enable Tamper Zone
X X X
#
U CTRL
Event Trigger IO (Zone 1 – 8)
70#
Select Zone
From 1 – 8
#
ZNNUM
Zone trigger Output
Zone LED ON means enable Output to turn ON
(*Zone 1 LED representing Output 1, Zone 2 representing Output 2 & etc)
X
ZN:IO
Select Timer
From 1-4
#
TIMNUM
Timer trigger output
Zone LED ON means enable Output to turn ON
(*Zone 1 LED representing Output 1, Zone 2 representing Output 2 & etc)
X
TIM:IO
Timer Output (Timer 1 – 4)
80#
GSM Setting
90#
GSM setting
Zone 1 LED ON means enable GSM module
Zone 2 LED ON means enable GSM Acknowledgement Report
XX XXXX X
GSMSET
91#
GSM Receiver No1
Max 18 digit receiver Number 1
[start with country code, eg 6012 345678]
[0] to erase GSM telephone number
#
GSM 1
92#
GSM Receiver No2
Max 18 digit receiver Number 2
[start with country code, eg 6012 345678]
[0] to erase GSM telephone number
#
GSM 2
93#
GSM Receiver No3
Max 18 digit receiver Number 3
[start with country code, eg 6012 345678]
[0] to erase GSM telephone number
#
GSM 3
94#
GSM Receiver No4
Max 18 digit receiver Number 4
[start with country code, eg 6012 345678]
[0] to erase GSM telephone number
#
GSM 4
Remark:
= LED ON, = LED OFF, X = Not in used. [Press the zone number to toggle the zone LED to ON or OFF]
Memory Viewing for Numeric setting
Press [COM] after enter the command to view memory.
Eg: Check Telephone No 1: [20#] + [COM], the phone number will be displayed one by one
Press [COM] again to exit memory viewing.
2
AX1 System Wiring Diagram
ASSURED LI VE S AFE
Reset Jumper
1
2
3
1
2
3
RESET
BATTERY WIRE
LED3
IMPORTANT:
Communication line to
Keypad and Expanders
AX1 ICON KEYPAD ID SETTING
KEYPAD
ID Setting
Keypad 1
1 2 3
4
1 2 3
4
1 2 3
4
1 2 3
4
DSW2
Notes:
Switch DSW1
shall ALL UP
Keypad 2
YELLOW
GREEN
RED
BLACK
Keypad 3
Keypad 4
:
Switch position
3