AdvanCE™ FS96 dsDNA Fragment Analyzer A D V A N C E D A N A LY T I C A L >I N S T R U M E N T C A PA B I L I T I E S SUPERIOR INSTRUMENT, SUPERIOR RESULTS The AdvanCE™ FS96 system has been designed for flexible operation, covering a wide range of DNA/RNA sizes and concentrations with high separation resolution. Different gel kits are interchangeable with the same capillary array. Detect SSRs With Confidence — Down to 2 bp Resolution Separate Consistently Over a Wide DNA Range 200 2711 2500 80000 70000 500 2000 RFU 50000 40000 1500 113 115 1000 800 500 900 600 10000 122 1000 400 300 20 20000 100 30000 700 RFU 60000 35 90000 300 97242.347 0 34:00 36:00 39:00 42:00 45:00 48:00 51:00 54:00 57:00 01:00 35 75 50 100 150 Time 200 300 Size DNF-910 Gel: 20 bp Extended Range DNA Ladder (Lonza®); 50 bands from 20 bp – 1,000 bp. DNF-900 Gel: Separation demonstrating resolution of 113 bp, 115 bp, and 122 bp DNA fragments. Resolve Large DNA Fragments Automate Mutation Detection Analysis Detect induced (and natural) point mutations in genomic DNA. High detection sensitivity (as low as 5 pg/μL) combined with a simplified cleavage process (no desalting step or EDTA addition) result in the efficient detection of mutations. The streamlined cleavage process and fast separation times yield improved throughput over manual methods. 3000 2399 2200 2000 1800 4000 5000 6000 900 800 700 600 400 400 300 100 600 200 800 1500 1000 2000 500 1200 1000 200 39:00 42:00 45:00 48:00 51:00 54:00 57:00 60:00 63:00 66:00 69:00 72:00 75:00 78:00 80:00 415 35:00 14000 Time 12000 10000 8000 1000 35 RFU DNF-920 Gels: Mixture of GeneRuler™ 100 bp DNA Ladder (Fermentas) and 1 Kb DNA Ladder (New England Biolabs®) 632 16963 16000 -80 217 RFU 1400 8000 10000 1600 6000 4000 Separate and Quantify Genomic DNA 2000 30:00 32:00 34:00 36:00 38:00 40:00 42:00 44:00 46:00 48:00 50:00 52:00 54:00 56:00 Time Pooled DNA (equivalent of 8 diploid organisms), amplified, cleaved and separated. The uncut fragment is 632 bp; cut fragments are 415 bp and 217 bp. Hind III λ Analyze Total RNA Quality No exchange of capillary array is required, streamlining operation and reducing costs compared to alternative methods. Intact Other Applications Degraded 10:00 15:00 20:00 25:00 30:00 35:00 40:00 45:00 Time DNF-930 Gel: Separation of λ DNA/HindIII Marker (Promega®) with intact (D1) and degraded (B1) genomic DNA. A D VA N C E D A N A LY T I C A L > WWW.AATI-US.COM >DNA and RNA Quantity and Quality Measurements >Restriction Digestion of DNA Fragments (CAPS Analysis) >SSCP >MLVA/MLPA AdvanCE ™ FS96 dsDNA FR A G M E N T A N A LY Z E R >A N A LY T I C A L S O F T W A R E IMPROVE THROUGHPUT BY DECREASING ANALYSIS TIME PRO Size™ data analysis software is designed to simplify calibration and fragment identification, and automate routine scoring and reporting of fragments. Flexible Data Display Data can be displayed in electropherogram or digital gel views for any combination of rows, columns or individual samples. Overlay random wells and adjust contrast, show/hide markers, zoom/autoscale and copy to other applications. Scoring and Output Create, save and import multiple flag criteria for scoring any data set. Results can be displayed and exported in various formats including binary output. Reports can be generated in Excel® or PDF format. >T E C H N O LO G Y AWARD-WINNING TECHNOLOGY * — UNIQUE, UNMATCHED CAPABILITIES Advanced Analytical’s parallel capillary gel electrophoresis separation technology dramatically improves laboratory throughput and efficiency and reduces operational costs. The AdvanCE™ FS96 system employs a powerful LED to excite separated and intercalated dsDNA or RNA as it passes through the capillary detection window, obviating the need for labeled primers. A sensitive CCD detector is expertly arranged to continuously collect the emitted signals. Proprietary signal processing provides superior dynamic range. With simultaneous injection and separation of 96 individual samples, the AdvanCE™ FS96 system is ideal for rapid, high throughput analysis of dsDNA or RNA fragments. Vacuum injection mode, a feature exclusive to the AdvanCE™ FS96 system, provides unique capabilities for high salt sample matrices and more accurate quantification of nucleic acids. A D VA N C E D A N A LY T I C A L > WWW.AATI-US.COM Capillaries Sample or Buffer Tray Fluorescence Excitation Detection Window Capillaries CCD Detector High Voltage Power Supply Outlet *Best Scientific Poster at TIDES 2005 Conference sponsored by BioProcess International. *R&D Magazine’s Top 100 Technologies for 2001. *R&D Magazine’s Most Promising New Technology Award 2001. AdvanCE ™ FS96 dsDNA FRAG M E N T A N A LY Z E R A d v a n C E ™ F S 9 6 d s D N A F R A G M E N T A N A LY Z E R >K E Y F E AT U R E S / B E N E F I T S >A 96-Capillary Array – Direct, parallel injection and separation of an entire 96-well plate at once. >Short Run Times – As little as 30 min for <1,000 bp. With the fastest 96-well plate cycle time of any CE system available, get more done in less time. >High Sensitivity – Detection limits as low as 5 pg/μL without desalting, allows direct injection of PCR and digest samples. >High Separation Resolution – Resolve a wide range of DNA/RNA fragments. Achieve as low as 2 bp resolution. Custom gels can be developed. >Multiple Injection Modes – Introduce samples by either electrokinetic (voltage) or vacuum injection. Exclusive to the AdvanCE™ system. Minimize impact from high salt or variable salt matrices. >W ide Dynamic Range – Covers 3 orders of magnitude. Less optimization needed. >Low Cost per Sample – Lower operational cost compared to agarose/acrylamide gels and cost savings by eliminating labeled primers. >Robotics Interface Capability – Allows for unattended, 24 h operation with automated plate exchange. >Variable Capillary Dimensions – Flexible capillary options allow instrument to meet changing laboratory or project needs. >User Friendly Software – Automate data scoring. Calculate fragment size and concentration, display data in multiple formats, create and save customized scoring parameters, export and report results with ease. >Real Time Viewing of Data – See results as they are being generated, change conditions during a run if desired. >A d v a n C E ™ F S 9 6 S Y S T E M T E C H N I C A L S P E C I F I C AT I O N S Maximum Sample Throughput: Maximum Unattended Sample Capacity: Minimum Sample Volume: Gel Sizing Ranges: Resolution: Sizing Accuracy: Detection Sensitivity: Light Source: Detector: Software: Data Export Format: Environmental Conditions: Relative Humidity Range: Electrical: Instrument Dimensions: Instrument Weight: 96 samples/30 min (20–1,000 bp fragment range) 192 samples; unlimited with robotic arm 20 μL for injection; as little as 1 μL sample required 10-500 bp; 50-2,000 bp; 500-12,000 bp; Genomic DNA Gel dependent; to as low as 2 bp Typically 5% or better As low as 5 pg/μL in PCR matrix 1,000 mW LED, 470 nm excitation wavelength High sensitivity CCD; 500-600 nm emission wavelength AdvanCE™ instrument control, PRO Size™ data analysis Microsoft® Excel® spreadsheet, binary output option Indoor use, normal laboratory environment 20-23°C < 80% (non-condensing) 100-200 VAC; 50-60 Hz; 15 A (Alternate configurations available) Fully configured 99.1 cm H x 243.8 cm W x 76.2 cm D (39 x 96 x 30 in) 88.6 kg (195 lbs) Advanced Analytical Technologies, Inc. 2711 South Loop Drive, Suite 4150 Ames, IA 50010 USA Phone: +1-515-296-6600 Fax: +1-515-294-7141 E-mail: [email protected] www.aati-us.com Copyright © 2010 Advanced Analytical Technologies, Inc. All Rights Reserved. Reproduction, adaptation or translation without prior written permission is prohibited, except as allowed under copyright laws. AdvanCE™ is a trademark of Advanced Analytical Technologies, Inc.
© Copyright 2026 Paperzz