NOTE! Clients must ensure that the requirements ofthe Party Wall Act 1996 are strictly adhered to and all legal requirements of the act discharged, prior to any work commencing adjacent to existing party and boundary walls. applicant Do Not Scale Drawing All Dimensions to be Checked on Site Prior to Commencement 1 Existin^g Side Elevation Mr B Greaves 32 Cumberland Drive Ardsley Barnsley 571 SDF Proposed Side Elevation Sun room ROOF: Roof spec as bedroom roof (see sheet I) flashing t o existing t o extend mm I 5 0 vert. ELECTRICAL: electrical spec as bedroom extension; VENTILATION: tncicle ventilation t o habitable rooms ec^ual t o 6 0 0 0 sq. mm.; under floor ventilation by air bricks set at 9 0 0 crs; HEATING: Central heating by extension of existing system; ail new radiators t o be fitted with TRV's; temperature control by room stats; EXTERNAL STEPS: Steps t o be constructed in bnckwork and cone; going 3 0 0 ; riser 2 2 0 ; handrails to sides t o be constructed of facing brickwork, with cone toppers; central handrail of steelwork; handrails t o be 9 0 0 mm high; t o p landing t o be I 5 0 0 wide; GENERAL NOTES: Samples of ail external materials t o be used in the construction of the dwelling t o be submitted t o and approved by the Planning Department prior t o commencement; Section Thro Sun Room Extension WALLS; Walls spec as bedroom \A/alls(see sheet I) GROUND FLOOR: Ground Floor of 2 2 thick flooring t * g boarding, on I OOxGS floor joists set at 4 0 0 crs; honey comb sleeper wall at mid span t o give max span of joists I 6 0 0 ; insulation t o floor by I 0 0 thick Crown Loft Roll between joists, suspended on polypropylene support netting; mm gap from wall t o chipboard floor of I Omm; apply self adhesive strip t o underside of skirting boards and two beads of sealant t o the back; ensure foam strip is compressed before fixing skirting in place; FOUNDATIONS: foundations as bedroom extension (see sheet I ) ; Site of I 0 0 cone on I 2 5 cosolidated hardcore; DOORS: Fit bi-fold door t o rear elevation as shown; doors by Duration windows or similar; all glazing t o doors and side panels within I 5 0 0 of floor level and t o windows within 6 0 0 of floor level t o be of safety glazing; safety glazing t o be permanently marked t o BS 6206; DRG No: BGOO Sheet 2 of 2 PROPOSED SINGLE STOREY SIDE BEDROOM EXTENSION and SUN ROOM EXTENSION at 3 2 CUMBERLAND DRIVE, ARDSLEY, BARNSLEY, 5 7 I SDF. PROPOSED PLANS AND ELEVATIONS Scale 1:50^ 1:100 - JANUARY 20 I 4 NOTE I Clients must ensure that the requirements ofthe Party Wall Act 1996 are strictly adhered to and all legal requirements ofthe aot discharged, prior to any work commencing adjacent to existing party and boundary walls. applicant Do Not Scale Drawin^g All Dimensions t o be Checked on Site Prior t o Commencement Mr B Greaves 3 2 Cumberland Drive Ardsley Barnsley 5 7 ! SDF Existing Rear Elevation Proposed Rear Elevation • • Porch Garage Bedroom 2 View on Arrow A Kitchen ELECTRICAL: All electrical work is reguired to meet the re(5|Uirement5 of Part F (Electrical Safety) and must be designed, installed and tested by an electrician registered under the 'Competent Persons Scheme' Prior t o completion the Council must be satisfied that Part P has been complied with; and an appropnate BS 7S7 I Electrical Installation certificate will be issued for the work, by a person competent t o do so; Alternatively an application will be made seperately t o the Local Authority Building Control m respect of the Approved Documents for the inspection and testing of the electrical installation; Bathroom V All internal light fittings t o accept energy efficient bulbs only; external lighting t o have lamps that do not exceed -I SOW and automatically switch off when there is enough daylight; and when not reguired at night; VENTILATION: trickle ventilation t o habitable rooms egual t o 6 0 0 0 sg. mm.; ventilation t o underfloor of sun room by air bricks set at 9 0 0 crs; Lounge HEATING: Central heating by extension of existinig system; all new radiators t o be fitted with TRV's; temperatuire control by room stats; Bedroom GENERAL NOTES: Samples of all external matenalls to be used in the construction of the dwellmg to be submitted t o and approved by the Planning Department prior to commencement; ROOF: Roof of cone interlocking tiles in style and colour t o match existing dwelling; on 3 6 x 2 5 tanalised s.w. battens; on I No layer of breathable felt; on trusses designed and manufactured by South Yorkshire Truss Supplies Doncaster or similar; calculations for trusses t o be submitted t o and approved by the Local Authority 2 6 days prior t o commencement; trusses set at GOO crs.; 100x25 diagnal wind bracing; web bracing; $ ceiling bracing t o full length of roof; solid noggings and packings at all anchor points; valleys of BML milted lead code 5 or 6 on laying boards, roof construction t o comply with BS 52G3 Part 3; 3 No. end trusses t o be tied t o walls using Catnic straps; screwed t o walls and t o cover 3 No trusses; I 00x75 wallplate anchored by 3 0 x 5 x 4 5 0 galv. M.S. straps set at 2 0 0 0 crs. max. I 0 0 x 5 0 binders set at all node points; ceiling of 3 0 0 thick Crown loft roll 4 0 insulation; laid I 0 0 between trusses, 2 0 0 over; underdrawn with I 2 . 5 thick plasterboard and skim; I J 2 half round upvc gutters on 2 2 5 x 2 5 white upvc facia; upvc soffit fitted with soffit vents, soffit ventilation t o be egual t o continuous I Omm ventilation strip; and covered by insect proof mesh; 7 € dia. upvc faltpipes; 100 dia. underground drainage pipework t o existing soakaways, or new soakaways 5 0 0 0 mm from buildings; position of soakaways t o be determined on stte in conjunction with building inspector; perculation tests t o be carried out as necessary; WALLS: Walls of cavity construction; outer leaf of facings t o match existing; I 0 0 cavity with I 0 0 thick Crown Dritherm cavity slab 3 2 insulation; I 0 0 thick low density block inner leaf; concrete commons t o both leaves below d.p.c,; and cavity fill with weak mix concrete t o ground level; or use Thermaiite Foundation Blocks; d.p.c. t o be mm I 5 0 min above fmished G.L.; internal finish of plasterboard on dabs and skim; continuous adhesive t o perimeter of dry lining and a foamed polyurathane between the wmdows/doors and surrounds t o reduce air leakage; polyfoam cavity closures t o be used at all cills and jambs t o eliminate any thermal bridge and t o achieve an airtight seal between windows and inner leaf; all joists built into walls to be fully mastic seaied; care to be taken with the extension t o ensure minimal air leakage; stainless steel twist wall ties set at 7 5 0 crs. horizontal; 4 5 0 crs. vertical; 2 2 5 crs. around openings and up unbonded reveals; horizontal and vertical d.p.c. t o all openings; Catnic lintels over all openings as marked on plan; mm end bearing I 5 0 ; all returns min GS5; brickwork bond 3 in G; blockwork bond every other course; or use Catnic wall ties; GROUND FLOOR: Ground Floor of I 0 0 thick concrete; on 1 0 0 thick Celotex insulation; on 2 0 0 0 g visgeen dpm; bonded t o horizontal dpc's; on I 25 thick consolidated hardcore; FOUNDATIONS: foundations of G I 0 x 2 2 5 concrete strips at depth t o the satisfaction of the I7A Building Inspector; but wtth 7G0 mm dig; 9 0 0 if into clay; and lower than any drains; foundations t o internal walls of 450x1 5 0 concrete strips at same depth as externals; Existing Ground rioor Plan WINDOWS AND DOORS: All windows to be double glazed With I G gap and low E coating; and t o give 1/20 of internal floor area opening min; frames of white upvc by Yorkshire Windows or similar; all glazing t o doors and side panels within I 5 0 0 of floor level and t o windows withm 6 0 0 of floor level t o be of safety glazing; safety glazing to be permanently marked t o BS G20G; new windows t o be escape windows; mm unobstructed opening 7 5 0 x 4 5 0 ; cill height between 6 0 0 and 1 100; o o la Section Thro Bedroom Extension 5460 DRG No: BGOO Sheet I of 2 7700 PROPOSED SINGLE STOREY SIDE BEDROOM EXTENSION Proposed Ground rioor Plan and SUN ROOM EXTENSION at 3 2 CUMBERLAND DRIVE, ARDSLEY, BARNSLEY, 5 7 I SDF. PROPOSED PLANS AND ELEVATIONS Scale 1:50$ 1:100 - DECEMBER 20 I 4
© Copyright 2024 Paperzz