Do Not Scale Drawing All Dimensions to be Checked on Site Prior to

NOTE!
Clients must ensure that the requirements ofthe
Party Wall Act 1996 are strictly adhered to and
all legal requirements of the act discharged, prior
to any work commencing adjacent to existing
party and boundary walls.
applicant
Do Not Scale Drawing
All Dimensions to be Checked on
Site Prior to Commencement 1
Existin^g Side Elevation
Mr B Greaves
32 Cumberland Drive
Ardsley
Barnsley
571 SDF
Proposed Side Elevation
Sun room
ROOF: Roof spec as bedroom roof (see sheet I)
flashing t o existing t o extend mm I 5 0 vert.
ELECTRICAL: electrical spec as bedroom extension;
VENTILATION: tncicle ventilation t o habitable rooms ec^ual t o
6 0 0 0 sq. mm.; under floor ventilation by air bricks set at
9 0 0 crs;
HEATING: Central heating by extension of existing system; ail
new radiators t o be fitted with TRV's; temperature control by
room stats;
EXTERNAL STEPS: Steps t o be constructed in bnckwork and
cone; going 3 0 0 ; riser 2 2 0 ; handrails to sides t o be
constructed of facing brickwork, with cone toppers; central
handrail of steelwork; handrails t o be 9 0 0 mm high; t o p
landing t o be I 5 0 0 wide;
GENERAL NOTES: Samples of ail external materials t o be used
in the construction of the dwelling t o be submitted t o and
approved by the Planning Department prior t o
commencement;
Section Thro Sun Room Extension
WALLS; Walls spec as bedroom \A/alls(see sheet I)
GROUND FLOOR: Ground Floor of 2 2 thick flooring t * g
boarding, on I OOxGS floor joists set at 4 0 0 crs; honey
comb sleeper wall at mid span t o give max span of joists
I 6 0 0 ; insulation t o floor by I 0 0 thick Crown Loft Roll
between joists, suspended on polypropylene support netting;
mm gap from wall t o chipboard floor of I Omm; apply self
adhesive strip t o underside of skirting boards and two beads
of sealant t o the back; ensure foam strip is compressed
before fixing skirting in place;
FOUNDATIONS: foundations as bedroom extension (see
sheet I ) ;
Site of I 0 0 cone on I 2 5 cosolidated hardcore;
DOORS: Fit bi-fold door t o rear elevation as shown; doors
by Duration windows or similar;
all glazing t o doors and side panels within I 5 0 0 of floor level
and t o windows within 6 0 0 of floor level t o be of safety
glazing; safety glazing t o be permanently marked t o BS
6206;
DRG No: BGOO
Sheet 2 of 2
PROPOSED SINGLE STOREY SIDE BEDROOM EXTENSION and
SUN ROOM EXTENSION at 3 2 CUMBERLAND DRIVE,
ARDSLEY, BARNSLEY, 5 7 I SDF.
PROPOSED PLANS AND ELEVATIONS
Scale 1:50^ 1:100
- JANUARY 20 I 4
NOTE I
Clients must ensure that the requirements ofthe
Party Wall Act 1996 are strictly adhered to and
all legal requirements ofthe aot discharged, prior
to any work commencing adjacent to existing
party and boundary walls.
applicant
Do Not Scale Drawin^g
All Dimensions t o be Checked on
Site Prior t o Commencement
Mr B Greaves
3 2 Cumberland Drive
Ardsley
Barnsley
5 7 ! SDF
Existing Rear Elevation
Proposed Rear Elevation
•
•
Porch
Garage
Bedroom 2
View on Arrow A
Kitchen
ELECTRICAL: All electrical work is reguired to meet the re(5|Uirement5
of Part F (Electrical Safety) and must be designed, installed and
tested by an electrician registered under the 'Competent Persons
Scheme'
Prior t o completion the Council must be satisfied that Part P has
been complied with; and an appropnate BS 7S7 I Electrical
Installation certificate will be issued for the work, by a person
competent t o do so;
Alternatively an application will be made seperately t o the Local
Authority Building Control m respect of the Approved Documents for
the inspection and testing of the electrical installation;
Bathroom
V
All internal light fittings t o accept energy efficient bulbs only; external
lighting t o have lamps that do not exceed -I SOW and automatically
switch off when there is enough daylight; and when not reguired at
night;
VENTILATION: trickle ventilation t o habitable rooms egual t o
6 0 0 0 sg. mm.; ventilation t o underfloor of sun room by air
bricks set at 9 0 0 crs;
Lounge
HEATING: Central heating by extension of existinig system; all
new radiators t o be fitted with TRV's; temperatuire control by
room stats;
Bedroom
GENERAL NOTES: Samples of all external matenalls to be used
in the construction of the dwellmg to be submitted t o and
approved by the Planning Department prior to
commencement;
ROOF: Roof of cone interlocking tiles in style and colour t o
match existing dwelling; on 3 6 x 2 5 tanalised s.w. battens; on
I No layer of breathable felt; on trusses designed and
manufactured by South Yorkshire Truss Supplies Doncaster or
similar; calculations for trusses t o be submitted t o and
approved by the Local Authority 2 6 days prior t o
commencement; trusses set at GOO crs.; 100x25 diagnal
wind bracing; web bracing; $ ceiling bracing t o full length of
roof; solid noggings and packings at all anchor points; valleys
of BML milted lead code 5 or 6 on laying boards, roof
construction t o comply with BS 52G3 Part 3; 3 No. end
trusses t o be tied t o walls using Catnic straps; screwed t o
walls and t o cover 3 No trusses; I 00x75 wallplate anchored
by 3 0 x 5 x 4 5 0 galv. M.S. straps set at 2 0 0 0 crs. max.
I 0 0 x 5 0 binders set at all node points; ceiling of 3 0 0 thick
Crown loft roll 4 0 insulation; laid I 0 0 between trusses, 2 0 0
over; underdrawn with I 2 . 5 thick plasterboard and skim; I J 2
half round upvc gutters on 2 2 5 x 2 5 white upvc facia; upvc
soffit fitted with soffit vents, soffit ventilation t o be egual t o
continuous I Omm ventilation strip; and covered by insect
proof mesh; 7 € dia. upvc faltpipes; 100 dia. underground
drainage pipework t o existing soakaways, or new soakaways
5 0 0 0 mm from buildings; position of soakaways t o be
determined on stte in conjunction with building inspector;
perculation tests t o be carried out as necessary;
WALLS: Walls of cavity construction; outer leaf of facings t o
match existing; I 0 0 cavity with I 0 0 thick Crown Dritherm
cavity slab 3 2 insulation; I 0 0 thick low density block inner
leaf; concrete commons t o both leaves below d.p.c,; and
cavity fill with weak mix concrete t o ground level; or use
Thermaiite Foundation Blocks; d.p.c. t o be mm I 5 0 min
above fmished G.L.; internal finish of plasterboard on dabs
and skim; continuous adhesive t o perimeter of dry lining and a
foamed polyurathane between the wmdows/doors and
surrounds t o reduce air leakage; polyfoam cavity closures t o
be used at all cills and jambs t o eliminate any thermal bridge
and t o achieve an airtight seal between windows and inner
leaf; all joists built into walls to be fully mastic seaied; care
to be taken with the extension t o ensure minimal air leakage;
stainless steel twist wall ties set at 7 5 0 crs. horizontal; 4 5 0
crs. vertical; 2 2 5 crs. around openings and up unbonded
reveals; horizontal and vertical d.p.c. t o all openings; Catnic
lintels over all openings as marked on plan; mm end bearing
I 5 0 ; all returns min GS5;
brickwork bond 3 in G; blockwork bond every other course;
or use Catnic wall ties;
GROUND FLOOR: Ground Floor of I 0 0 thick concrete; on
1 0 0 thick Celotex insulation; on 2 0 0 0 g visgeen dpm;
bonded t o horizontal dpc's; on I 25 thick consolidated
hardcore;
FOUNDATIONS: foundations of G I 0 x 2 2 5 concrete strips at
depth t o the satisfaction of the I7A Building Inspector; but
wtth 7G0 mm dig; 9 0 0 if into clay; and lower than any drains;
foundations t o internal walls of 450x1 5 0 concrete strips at
same depth as externals;
Existing Ground rioor Plan
WINDOWS AND DOORS: All windows to be double glazed
With I G gap and low E coating; and t o give 1/20 of internal
floor area opening min; frames of white upvc by Yorkshire
Windows or similar; all glazing t o doors and side panels within
I 5 0 0 of floor level and t o windows withm 6 0 0 of floor level
t o be of safety glazing; safety glazing to be permanently
marked t o BS G20G; new windows t o be escape windows;
mm unobstructed opening 7 5 0 x 4 5 0 ; cill height between 6 0 0
and 1 100;
o
o
la
Section Thro Bedroom Extension
5460
DRG No: BGOO
Sheet I of 2
7700
PROPOSED SINGLE STOREY SIDE BEDROOM EXTENSION Proposed Ground rioor Plan
and SUN ROOM EXTENSION at 3 2 CUMBERLAND DRIVE,
ARDSLEY, BARNSLEY, 5 7 I SDF.
PROPOSED PLANS AND ELEVATIONS
Scale 1:50$ 1:100
- DECEMBER 20 I 4