Product data sheet 67.440 RLP100F910, F916, F918: Dual-channel air-volume controller How energy efficiency is improved For demand-based volume flow control of dual-channel systems in offices Features • Optimum use of energy thanks to RLP100 2-channel controller in combination with room operating units of the TSP, TSFP and TSSP series • Compatible with practically all currently-available mixing boxes • Suitable for explosion hazard zone 1 II 2 G T6 • Conformity tested as per EN 13463-1 and EN 1127-1 (ex zone 1 II 2 G T6) • Controls constant, switchable or variable air volumes • Accurate, static differential pressure sensor with large measuring range • Front plate printed with circuit diagrams for easy identification of the controller functions • Compressed-air connections with Rp⅛" female thread • Special measuring connection for detecting the air volume • Low-pressure connections with dual-diameter connector for soft plastic tubing (internal Ø 4 and 6 mm) • 2 inputs • Command variable • Day/night change-over or heating/cooling signal • 3 outputs • Actual value, air volume • Activates two damper actuators, heating and cooling • 1 adjuster for setting the sensor measuring range • 2 setpoint adjusters for maximum and minimum limitation of the air volume Technical data Parameters Admissible pressure RLP100F91* RLP100F910, RLP100F916 RLP100F918 Low-pressure connections 3000 Pa Supply pressure 1.3 bar ±0.1 Operating range Pstat 0...3000 Pa Response sensitivity 0.1 Pa Input for setpoint shift w1, w2; 20...100% m 0.2...1.0 bar Measuring range ∆p (factory setting) 6.4...160 Pa, can be reduced to 1...25 Pa Ambient conditions Admissible ambient temperature 0...55 °C Setting range for setpoint 20...100% m Output pressures 0.2...1.0 bar Inputs/Outputs Linearity and accuracy of root extrac- 2% of 100% m tion Construction Housing material Glass-fibre-reinforced thermoplastic Fitting To walls or top-hat rails (EN 60715 rail) Weight 0.6 kg Type of protection IP 30 Type RLP100F910 RLP100F916 Properties Constant-air-volume controller (PI) for full-range actuators Constant VAV controller (PI) for sequential actuators Air capacity, connection 2, cooling 400 ln/h 100 ln/h Standards and directives Overview of types Right of amendment reserved © 2015 Fr. Sauter AG 6.1 1/5 67.440 Product data sheet Type RLP100F910 RLP100F916 Air capacity, connection 7, heating 400 ln/h 18 ln/h Air consumption 53 ln/h 60 ln/h P-band (fixed) 100% 400% Accessories Type Description 0297354000 Short screw-in connector R⅛", for soft plastic tubing Ø 4 mm (internal) 0297762001 Restrictor Ø 0.8 mm for damping turbulent low-pressure signals 0274571000 Restrictor Ø 0.5 mm for damping turbulent low-pressure signals 0297870001 Bracket for fixing to ceilings, floors or in panels A A A 0297354000: 5 pieces required 0297762 001: Can be plugged into soft plastic hose, inner Ø 4 mm. If attenuation is insufficient, instead of the Ø 0.8 mm restrictor, the Ø 0.5 mm restrictor can be used (accessory 0274571; this restrictor is not suitable for RLP100F908, F914, F123). 0274571 000: Can be plugged into soft plastic hose, inner Ø 4 mm. Suitable for extreme cases when the Ø 0.8 mm restrictor (accessory 0297762) does not provide sufficient attenuation. Not suitable for volume flow controllers (RLP100F914, F123) and transducers (RLP100F908) where the “+ and -” low pressure line is constantly supplied with a very small quantity of air, because the pressure signals in the lower measuring range are falsified and the positioning time of 1...2 s (RLP100F123) is not achieved. Additional information Fitting instructions RLP100F916 MV 505338 RLP100F918 MV 505262 RLP100F910 MV 505089 VAV technical manual 7 000 621 001 Description of operation A square root transducer converts the pressure difference (6.4...160 Pa) produced at an orifice plate or pitot tube into a standard signal (0.2...1.0 bar) that is linear to the flow. The pressure difference of the setpoint range (E = 0.7...1.8) is set using the adjuster E. The integral controller compensates for the control deviations with no persistent error. RLP100F916: The command variable w shifts the volume flow (e.g. TSP 80 B temperature controller). An external setpoint signal can be supplied via connection 8 and limited with the adjusters mmin and mmax. When the connection is open mmin is effective, and when it is closed mmax applies. RLP100F918: The command variables w1 (heating) and w2 (cooling) shift the volume flow (e.g. TSSP 80 temperature controller). The volume flows for heating and cooling can be individually limited using the mmin and mmax adjusters and the internal adjuster mmax (int.). RLP100F910: The command variable w shifts the heating volume flow (e.g. TSP 80 B temperature controller). The ratio of hot to cold air is fixed at 1:2. An external setpoint signal can be supplied via connection 8 and limited with the adjusters mmin and mmax. When the connection is open mmin is effective, and when it is closed mmax applies. Intended use This product is only suitable for the purpose intended by the manufacturer, as described in the “Description of operation” section. All related product documents must also be adhered to. Changing or converting the product is not admissible. Engineering and fitting notes Crosswise mounting is not permitted. 2/5 6.1 Right of amendment reserved © 2015 Fr. Sauter AG Product data sheet 67.440 To prevent turbulent flow causing vibrations that affect the low pressure signal, there must be a smoothing sector in front of the cross meter for measuring the differential pressure. Where there are unfavourable inflows – bends, elbows or branches immediately in front of the cross meter – a restrictor (accessory 0297762 or 0274571) must be installed in the plastic hose of the + and – connection to attenuate turbulent low pressure signals. Disposal When disposing of the product, observe the currently applicable local laws. More information on materials can be found in the Declaration on materials and the environment for this product. Connection diagrams RLP 100 F916 RLP 100 F918 E 1 1 E DP I E xi 1,3 bar p1 PI 1 DP 1 E xi Controller I 16 l/h 16 l/h Controller 8 2 6 y2 DP 8 y1 DP NC 0,2...1,0 y2 NC 0,2...1,0 V M RLP 100 F910 E 1,3 bar 1 p1 2 y1 0,2...0,6 V DP 7 w2 T NC NC 0,6...1,0 6 w1 T 1,3 bar Controller 7 w1 0,2...1 bar 1,3 bar p1 xi 1 E PI 1:2 Min Controller 2 8 7 6 y2 w1 ??? ????? DP y1 p1 NC 0,2...1,0 NC T 0,2...1 V Right of amendment reserved © 2015 Fr. Sauter AG 6.1 3/5 67.440 Product data sheet Dimension drawing 12 Ø6,8 Ø4,7 20 70 103 136 s11 8,5 5 8 7 2 110 1 23,5 23,5 23,5 23,5 6 88 Rp 1/8 (ISO 7/1) Accessories 297870 001 150 6 10 135 M00568 s10 1,5 4,5 Ø5 (ISO 7/1) R 1/8 297354 14 M09889 108 28 Application example for RLP100F918 VAV control facility for 2-duct installations with room temperature for heating and cooling 0,2...1,0 bar NC 2 AK 31P 3 3 V KL V non-pressursed room FO NC 4 T AK 31P 2 NC l < 0,3 m 1,3 bar PD/F 1 M 6 8 I 5 P 2 7 TSSP 80 1 PD/F 1 2 1,3 bar 1 6 I 2 2 RLP 100 F001 RLP 100 F918 6 3 1:1 2 XRP 101 4/5 6.1 Right of amendment reserved © 2015 Fr. Sauter AG AK 31P 0,2...1,0 bar WL Product data sheet 67.440 1 VAV controller 4 Room temperature controller CA 2 Damper actuator 5 2-duct VAV controller WA Cold air Warm air 3 Reducing box 6 Interface relay EA Exhaust air NC Normally closed Fr. Sauter AG Im Surinam 55 CH-4016 Basel Tel. +41 61 - 695 55 55 www.sauter-controls.com Right of amendment reserved © 2015 Fr. Sauter AG 6.1 5/5
© Copyright 2026 Paperzz