CT Main Disconnect Panel Application: Provide emergency shutdown, under voltage protection, overcurrent protection, OSHA Lock Out/Tag Out provisions, and serves as a local disconnect for the Diagnostic Imaging System. It automatically restores power to the equipment following a power loss with a brief delay before re‐energizing to allow for the incoming power to stabilize, reducing the potential for damage to sensitive electronic devices encountered when switching to backup power. Advantages: Helps reduce installation time by providing a single‐point power connection Proven components and designs eliminate guesswork Standard configurations suitable for use in 25kA short‐circuit current rated (SCCR) power systems Standardized design and testing helps ensure high product quality and system reliability Includes installation and operation manual UL and cUL listed, labeled, tested and conforms to National Electric Code Surface or semi‐flush mounting High SCCR ratings and a variety of custom configurations are available. Please contact Bevco Imaging Suite Controls for consultation Configuration: © 2011 Bevco Engineering Company, Inc. Ordering Information: Basic Panels Nominal Dimensions Height Width Depth Basic Part Number 3‐Phase Voltage Amperage CT480‐090‐BB 440/460/480 50/60 Hz 90 24" 15" 9" CT480‐110‐BB 440/460/480 50/60 Hz 110 30" 24" 9" CT480‐125‐BB 440/460/480 50/60 Hz 125 30" 24" 9" CT480‐150‐BB 440/460/480 50/60 Hz 150 30" 24" 9" CT400‐090‐BB 380/400/415 50/60 Hz 90 24" 15" 9" CT400‐110‐BB 380/400/415 50/60 Hz 110 30" 24" 9" CT400‐125‐BB 380/400/415 50/60 Hz 125 30" 24" 9" CT400‐150‐BB 380/400/415 50/60 Hz 150 30" 24" 9" Option ‐BB ‐BU Description Basic Main Disconnect Panel UPS Interface option. Fully integrate emergency power off function if an Uninterruptible Power Supply (by others) is included in the system. See below for compatible UPS Bypass Panel for UPS maintenance and safety. System‐matched UPS Bypass Panels Basic Part Number UB100‐120 UB150‐180 UP225‐270 UB300‐360 UB100‐600 kVA Rating 100 kVA 150 kVA 225 kVA 300 kVA 500 kVA Amperage @ 480V3PH 120 180 270 360 600 Nominal Dimensions Height Width Depth 24" 15" 9" 24" 15" 9" 24" 15" 9" 30" 24" 9" 24" 9" 30" Listed above are common options and configurations. A wide variety of potential combinations of voltage, short‐circuit current ratings, and amperage requirements can be accommodated. Please CONTACT US with your specific needs. Bevco Imaging Suite Controls W222N5739 Miller Way, Sussex, WI 53089 Phone (262) 820‐2400 Fax (262) 820‐2599 www.bevcoisc.com © 2011 Bevco Engineering Company, Inc.
© Copyright 2025 Paperzz