StealthWatch FlowCollector 5000 Specification Sheet

SPECIFICATION SHEET | StealthWatch Flow Collector 5000
STEALTHWATCH®
FLOW COLLECTOR™ 5000
ENGINE & DATABASE
First Ship Date: 1/2015
Final Ship Date: Currently Shipping
This specification sheet includes both appliances used for the Stealthwatch Flow Collector 5000. (Your
models may look slightly different.) The Flow Collector 5000 engine (on this page) is connected to the
database (on page 3) by a crossover (copper network) cable with SFP+ connections that is supplied
with the appliances. For installation information, see the Stealthwatch System Hardware Installation
Guide v6.x.
Note: The iDRAC port can be used but is not supported.
Flow Collector 5000 Engine
Front
Back
Specifications
Maximum Flows Per Second (fps)
Maximum Exporters
240,000* fps
4,000
Hardware Platform
Hardware Generation
R620
12G
Rack Units (Mountable)
Weight
1U, Sliding Ready Rails with Cable Management Arm
41 pounds (18.6 kg)
Shipping Dimensions
Shipping Weight
Height: 11 inches (27.9 cm)
Width: 24 inches (61 cm)
Depth: 36 inches (91.4 cm)
© 2017 Cisco and/or its affiliates. All rights reserved.
65 pounds (29.5 kg)
SPECIFICATION SHEET | StealthWatch Flow Collector 5000
- continued -
Dimensions
Network
Height: 1.68 inches (4.3 cm)
Width: 18.99 inches (48.2 cm) with rack latches
17.08 inches (43.4 cm) without rack latches
Depth: 29.25 inches (74.3 cm) with power supply and bezel
27.25 inches (69.2 cm) without power supplies and
bezel
Management Port: 1; 10/100/1000 copper
Humidity (Relative)
Altitude
Operating: 20% to 80% (non-condensing) at a maximum wet bulb
temperature of 84.2° F (29° C)
Storage: 5% to 95% (non-condensing) at a maximum wet bulb
temperature of 100.4° F (38° C)
Operating: -50 feet to 10,000 feet
(-15.2 meters to 3,048 meters)
Storage:
-50 feet to 35,000 feet
(-15.2 meters to 10,668 meters)
Power
Heat Dissipation
Redundant 750 W AC, 50/60 Hz
Auto Ranging (100V to 240V)
2,891 BTU per hour maximum
Temperature
Vibration
Operating: 50° F to 95° F (10° C to 35° C) at 10% to 80% relative
humidity, with 78.8° F (26° C) maximum dew point
Operating Maximum: 0.26 Grms at 5-350 Hz in all
orientations
Storage Maximum: 1.87 Grms at 10-500 Hz for 15
minutes (all six sides tested)
Note: For altitudes above 2,952 feet, the maximum allowable dry
bulb temperature is derated at 1° F (-17° C) per 550 feet (1.67 m).
Storage: -40° F to 149° F (-40° C to 65° C) with a maximum
temperature gradation of 68° F (20° C) per hour
Shock
Regulatory
Operating Maximum: Half sine shock in all operational
orientations of 31G plus or minus 5% with a pulse duration of 2.6
ms plus or minus 10%
Storage Maximum: Half sine shock on all six sides of 71G plus or
minus 5% with a pulse duration of 2 ms plus or minus 10%; square
wave shock on all six sides of 27G with a velocity change at 235
inches per second or greater.
FCC (U.S. only) Class A
DOC (Canada) Class A
CE Mark (EN 55022 Class A,
EN 55024, EN 61000-3-2,
EN 61000-3-3, EN 60950)
VCCI Class A
UL 1950
CSA 950
Please call for a complete list.
*The maximum fps can change depending on network conditions. Please contact a Lancope representative for details.
Please continue to the next page for Flow Collector 5000 database specifications.
© 2017 Cisco and/or its affiliates. All rights reserved.
ss-fc5000-01222017
2
SPECIFICATION SHEET | StealthWatch Flow Collector 5000
Flow Collector 5000 Database
Front
Back
Specifications
Hardware Platform
Hardware Generation
R820
13G
Network
Storage
Management Port: 1; 10/100/1000 copper
Console Port: Serial, KVM
6 TB (RAID-1/0 Redundant)
Rack Units (Mountable)
Weight
2U, Stackable
Sliding Ready Rails with Cable Management Arm
65 pounds (40.9 kg)
Dimensions
Power
Height:
Width:
Redundant 750 W AC, 50/60 Hz
Auto Ranging (100V to 240V)
Depth:
3.42 inches (8.68 cm)
18.99 inches (48.24 cm) with rack latches
17.08 inches (43.4 cm) without rack latches
32.02 inches (81.33 cm) with power supply and bezel
30 inches (76.1cm) without power supplies and bezel
- continued -
© 2017 Cisco and/or its affiliates. All rights reserved.
ss-fc5000-01222017
3
SPECIFICATION SHEET | StealthWatch Flow Collector 5000
Shipping Dimensions
Shipping Weight
Height: 11 inches (27.9 cm)
Width: 25 inches (63.5 cm)
Depth: 36 inches (91.4 cm)
90 pounds (29.5 kg)
Temperature
Heat Dissipation
Operating: 50° F to 95° F (10° C to 35° C) at 10% to 80%
relative humidity, with 78.8° F (26° C) maximum dew point
2,891 BTU per hour maximum
Note: For altitudes above 3,117 feet, the maximum allowable
dry bulb temperature is derated at 1° F (-17° C) per 547 feet
(167 m).
Storage: -40° F to 149° F (-40° C to 65° C) with a maximum
temperature gradation of 68° F (20° C) per hour
Humidity (Relative)
Altitude
Operating: 20% to 85% (non-condensing) at a maximum wet
bulb temperature of 78.8° F (26° C)
Storage: 5% to 95% (non-condensing) at a maximum wet bulb
temperature of 91° F (33° C)
Operating: -50 feet to 10,000 feet
(-15.2 meters to 3,048 meters)
Storage:
-50 feet to 39,370 feet
(-15.2 meters to 12,000 meters)
Vibration
Shock
Operating Maximum: 0.26 Grms at 5-350 Hz in all orientations
Storage Maximum: 1.87 Grms at 10-500 Hz for 15 minutes (all
six sides tested)
Operating Maximum: Half sine shock in all operational
orientations of 31 G plus or minus 5% with a pulse duration
of 2.6 ms plus or minus 10%
Storage Maximum: Half sine shock on all six sides of 71 G
plus or minus 5% with a pulse duration of 2 ms plus or
minus 10%; square wave shock on all six sides of 27 G with
a velocity change at 235 inches per second or greater.
Regulatory Compliance
•
•
•
FCC (U.S. only) Class A
DOC (Canada) Class A
VCCI Class A
© 2017 Cisco and/or its affiliates. All rights reserved.
•
•
UL 1950
CSA 950
•
CE Mark (EN 55022 Class A, EN 55024,
EN 61000-3-2, EN 61000-3-3, EN 60950)
Please call for a complete list.
ss-fc5000-01222017
4