3i 3i Series Infrared Thermometer Noncontact Temperature Measurement Specialized Models for Specialized Applications Advanced applications and processes need specialized tools like the Raytek 3i IR (infrared) thermometer. The Raytek 3i series of noncontact thermometers measures surface temperature in places other thermometers cannot. With a choice of spectral responses, temperature ranges, laser sighting options and on-board data logging capabilities, the Raytek 3i meets the individual requirements of demanding users. Find Quality Products Online at: Contact us. [email protected] www. .com GlobalTestSupply [email protected] Raytek 3i Series O vercome the limitations of contact thermometers in manufacturing plants with Raytek 3i series infrared thermometers. For the most accurate readings in hot environments, the 3i thermometer compensates for the energy reflected by the background around the target. Reflected background energy compensation allows for accurate measurement even when the area measured is reflecting energy from nearby objects with higher temperatures; for example, inside a furnace. Varying spectral responses, laser-sighting systems, and distance-to-measurement spot ratios ensure the Raytek 3i temperature measurements are precise. 1M and 2M Raytek high temperature infrared thermometers, such as the 3i 1M & 2M models are ideal for foundry and processing operations, such as heat treating, tempering and forging. LT and LR For maintenance and quality control applications, the Raytek 3i Low Temperature (LT) and Long Range (LR) models are available for various temperature range and optical requirements. The strong 105:1 distance-tospot ratio of the 3i LRL2SC thermometer combined with a –30 to 1200°C (-20 to 2200°F) temperature range and scope permits easy temperature measurements of elevated objects at great distances, such as electrical connectors in towers. Due to the high-resolution 180:1 optics of the Raytek 3i 1M unit, it can take the approximate temperature measurements of molten glass by measuring the surface temperature of the port arch and bridge wall. Measuring the surface temperature of regenerator stacks or furnace melts may also assess the possibility of brick damage. Ideally suited for: G5 and P7 Accurately measure glass and plastics processing with specialized spectral responses using the Raytek 3iG5 or 3iP7 unit. The 3iG5 model is a 5-micron instrument designed for glass manufacturing and recycling, and is useful for temperature measurements of float sheets and gobs. The 7.9-micron Raytek 3iP7 model is designed for applications in producing and converting film plastics. Well suited for many processes within glass and plastic manufacturing. G5 NElectrical NPlant NPaper NFire Connectors Steel N Foundry and Processing Operations Ceramics N Chemical Furnaces N Petrochemical Furnaces N Production Lamination Flexo-Printing NFilm Orientation NExtrusion and Coating NPET, flouroplastic, Teflon®, acrylic, nylon (polyanide) cellulose, acetate, polyimide, polyurethane, PVC, polycarbonate N Metal Refining N N Maintenance N N Semiconductor NUtilities N Iron N N Useful in the following manufacturing situations: Tempering Annealing NForming NSealing NLaminating NBending P7 Safety Find Quality Products Online at: Contact us. [email protected] www. .com GlobalTestSupply [email protected] Laser Sighting Options Single Laser (L2, L3) Dual Laser (DL2, DL3) Single laser models are designed The dual laser uses two laser for accuracy over distances and spots to indicate the diameter pinpoint the center of the target of the target area measured. area with a bright laser spot. The single laser L3 unit is equipped with a 4 milliwatt laser, providing the brightest laser guide. Models ending with L2 meet FDA Class II and IEC Class 2 requirements. Models ending with L3 meet FDA Class IIIa requirements. Scope Only (SC) or Scope with Laser (SCL2) Measure temperature at a distance in bright daylight. At the focus point, 3i scopes are parallax-free and provide circular reticles for pinpoint accuracy. To enhance the sighting capabilities of the scope, combine the scope with a laser equipped model. Crossed Laser (CL2, CL3) For precise measurement of smaller targets, minimum measurement spot is indicated at the point the two laser beams meet. Optical Resolutions D:S (distance to spot using 90% encircled energy at focal point) 208 5 363 483 248 603 9 6 15 12 DISTANCE (SENSOR TO OBJECT IN METERS) FOCUS POINT D:S = 25:1 @15 m (50 ft) IR Spot Diameter at Lens = 23 mm (0.9 in) Laser Diameter at Lens = 40 mm (1.6 in) FAR FIELD D:S = 23:1 2.8 71 0 1.5 5.1 127 3 15 7.5 30 20 50 LRL2 LRL3 LRSC 24.0 19.5 14.5 208 5 363 483 248 603 9 6 15 12 DISTANCE (SENSOR TO OBJECT IN METERS) FOCUS POINT D:S = 25:1 @15 m (50 ft) IR Spot Diameter at Lens = 23 mm (0.9 in) Laser Diameter at Lens = 40 mm (1.6 in) FAR FIELD D:S = 23:1 30 20 40 50 2ML2 2ML3 2MSC 1.0 in @ 15 ft 0.8 1.5 13 18 36 2.3 57 3.2 80 4.0 100 25 mm @ 4.6 m 0 1.5 3 9 6 12 15 DISTANCE (SENSOR TO OBJECT IN METERS) FOCUS POINT D:S = 180:1 15 10 0 FAR FIELD D:S = 90:1 30 20 2.4 43 61 3 3.3 81 50 4.1 5.0 102 9 6 40 12 LTCL2 LTCL3 124 15 30 20 50 8.8 3.0 165 9 203 15 12 FAR FIELD D:S = 68:1 IR Beam Profile Laser Profile DISTANCE (SENSOR TO OBJECT IN INCHES) 0 60 36 180 120 Focus Point 7.3 0.3 IN @ 24 IN 0.9 4.6 1.9 23 48 118 8 mm @ 610 mm 203 0 1000 1500 5000 3000 DISTANCE: (SENSOR TO OBJECT IN MILLIMETERS) FAR FIELD D:S = 20:1 IR Beam Profile Laser Profile DISTANCE (SENSOR TO OBJECT IN INCHES) 0 36 74 171 9 6 12 218 15 DISTANCE (SENSOR TO OBJECT IN METERS) 60 20 3.6 2.1 0.9 23 53 97 25 mm @ 1900 mm 0 1000 1500 3000 5000 DISTANCE (SENSOR TO OBJECT IN MILLIMETERS) FOCUS POINT D:S = 75:1 FAR FIELD D:S = 60:1 180 120 Focus Point 1.0 IN @ 75 IN FAR FIELD D:S = 40:1 IR Spot Diameter at Lens = 23 mm (0.9 in) IR Spot Diameter at Lens = 23 mm (0.9 in) 3i Models 124 6 50 8.0 DISTANCE (SENSOR TO OBJECT IN METERS) 0.8 122 3 3 FOCUS POINT D:S = 75:1 LTSC 51 mm @ 4.6 m 0 86 IR Spot Diameter at Lens = 23 mm (0.9 in) Laser Diameter at Lens = 40 mm (1.6 in) 4.9 FOCUS POINT D:S = 90:1 FAR FIELD D:S = 140:1 40 6.8 2.0 in @ 15 ft 38 51 40 6.5 5.0 3.5 2.0 0 1.5 30 20 Low Temperature Focus Point 1.5 33 FAR FIELD D:S = 100:1 DISTANCE (SENSOR TO OBJECT IN FEET) 10 1.3 10 IR Spot Diameter at Lens = 23 mm (0.9 in) Laser Diameter at Lens = 40 mm (1.6 in) DISTANCE (SENSOR TO OBJECT IN METERS) 0 5 Low Temperature 1.7 0 DISTANCE (SENSOR TO OBJECT IN FEET) 0 FOCUS POINT D:S = 75:1 @15 m (50 ft) DISTANCE (SENSOR TO OBJECT IN FEET) IR Spot Diameter at Lens = 7 mm (0.3 in) Sighting Options 12 2M for Metals Focus Point 0.5 143 IR Spot Diameter at Lens = 23 mm (0.9 in) Spot Diameter (mm) Spot Diameter (in) Spot Diameter (mm) 1ML2 1ML3 1MSC 10 6 FOCUS POINT D:S = 120:1 @ 15 m (50 ft) DISTANCE (SENSOR TO OBJECT IN FEET) 5 9 119 LTDL2 LTDL3 DISTANCE (SENSOR TO OBJECT IN METERS) IR Beam Profile Laser Profile 1M for Metals and Molten Glass 0 0 95 4.8 5.7 Long Range 40 10.0 71 50 IR Spot Diameter at Lens = 23 mm (0.9 in) Spot Diameter (mm) Spot Diameter (in) Spot Diameter (mm) P7DL2 P7DL3 10 47 3.8 FOCUS POINT D:S = 105:1 @ 15 m (50 ft) DISTANCE (SENSOR TO OBJECT IN FEET) 5 2.8 3 IR Beam Profile Laser Profile P7DL for Thin Film Plastics 0 1.9 40 Spot Diameter (in) LRSCL2 19.5 14.5 30 20 Spot Diameter (mm) 10.0 10 0 Spot Diameter (in) 24.0 Spot Diameter (in) 50 Spot Diameter (mm) 3 40 Spot Diameter (in) 0 1.5 127 7.5 30 20 DISTANCE (SENSOR TO OBJECT IN FEET) Spot Diameter (mm) 71 5.1 15 Spot Diameter (mm) 2.8 10 Spot Diameter (in) 5 Spot Diameter (in) Spot Diameter (in) Spot Diameter (mm) P7DL2 P7DL3 DISTANCE (SENSOR TO OBJECT IN FEET) 0 Low Temperature Long Range G5SC for Glass 2 Micron (2M) Glass (G5) Plastic (P7) Single Laser (L2) Class II Low Temp (LT) Long Range (LR) 1 Micron (1M) - LRL2 1ML2 2ML2 - - Single Laser (L3) Class IIIa - LRL3 1ML3 2ML3 - - LTDL2 - - - - P7DL2 Dual Laser (DL3) Class IIIa LTDL3 - - - - P7DL3 Crossed Laser (CL2) Class II LTCL2 - - - - - Crossed Laser (CL3) Class IIIa LTCL3 - - - - - Scope (SC) LTSC LRSC 1MSC 2MSC G5SC - - LRSCL2 - - - - Dual Laser (DL2) Class II Scope with Laser (SCL2) Class II Find Quality Products Online at: Contact us. [email protected] www. .com GlobalTestSupply [email protected] Model LT Specifications and Features Temperature Range LR -30/1200ºC Accuracy Repeatability Response Time (95%) Spectral Response Adjustable Emissivity* (from 0.1 to 1.0 by 0.01) Ambient Operating Temperature Relative Humidity Storage Temperature Weight/Dimensions Power Battery Life (Alkaline) Laser Reflected Energy Compensation Distance to Spot (D:S) MAX, MIN, DIF, AVG Temperatures Display Hold Backlit LCD Temperature Display Display Resolution Locking Trigger Tripod Mounting Audible/Visible Hi/Lo Alarms Analog Output Digital Output 100 Point Data Logging LRSCL2 (-20/2200ºF) 1M 2M G5 P7 600/3000ºC 200/1800ºC 150/1800ºC 10/800ºC (1100/5400ºF) (400/3275ºF) (300/3275ºF) (50/1450ºF) ±0.5% of reading or ±1ºC (±1.5ºF) ±1% of reading or ±1ºC (±1.5ºF) ±1% of reading or ±1ºC (±1.5ºF) whichever whichever is greater at 23ºC ±5ºC whichever is greater at 23ºC ±5ºC is greater at (73ºF ±9ºF) ambient operating (73ºF ±9ºF) ambient operating 23ºC ±5ºC temperature temperature (73ºF ±9ºF) ambient operating temperature ±0.5% of reading or ±1ºC ( ± 1ºF), whichever is greater 700 mSec 550 mSec 700 mSec 8 to 14µm 1.0µm 1.6µm 5µm 7.9µm 0 to 50ºC (32 to 120ºF) 10 to 90%, noncondensing @ up to 30ºC (86ºF) -20 to 50ºC (-4 to 120ºF) without batteries Laser Models: 208 H x 257 L x 71 W mm / 794 g (8.2 H x 10.1 L x 2.8 W in / 1.75 lb) Scope Models: 244 H x 257 L x 71 W mm / 1000 g (9.6 H x 10.1 L x 2.8 W in / 2.21 lb) 4 AA batteries or 6 to 9 V, 200 mA DC power supply 21–25 hours L2 models are IEC Class2/FDA Class II (<1mW), L3 models are FDA Class IIIa (<5mW) 75:1 120:1 105:1 180:1 90:1 50:1 25:1 7 Seconds ºC or ºF (selectable), multifunction 4-digit backlit LCD 1ºC or 1ºF 1mV/ºC or 1mV/ºC or 1mV/ºC or 1mV/ºF 0.5 mV/ºF 1mV/ºF RS232, 9600 baud, output interval adjustable from 1 to 9999 seconds Nylon carry case with shoulder strap • NIST Certification (Must be specified at time of order) Variable brightness filters (scope and G5 only) • 110V/60Hz or 220V/50Hz voltage adapters Portable printer and cable • Computer, analog, and printer cables • DataTemp 2 software • Hard shell case Options/ Accessories * For more details visit www.raytek.com/emissivity.htm The Worldwide Leader in Noncontact Temperature Measurement Raytek Corporation Worldwide Headquarters Santa Cruz, CA USA Tel: 1 800 227 8074 (USA and Canada, only) 1 831 458 3900 [email protected] European Headquarters Berlin, Germany Tel: 49 30 4 78 00 80 [email protected] France Tel: 0800 888 244 [email protected] China Headquarters Find Quality Products Online at: Beijing, China United Kingdom Tel: +44 1908 630 800 [email protected] www.raytek.com Contact us. [email protected] www. .com GlobalTestSupply [email protected]
© Copyright 2026 Paperzz