Contents Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Standard Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Optional Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Optional Microprocessor Controller. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Performance Specifications—Air Cooled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Performance Specifications—Water Cooled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Performance Specifications—Glycol Cooled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Performance Specifications—Chilled Water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Air-Cooled Condensers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Fluid Coolers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Remote Condensing Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Pump Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Guide Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Guidelines for Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 CM Capacity (kW) CM 003 005 007 R= Air Cooled with Remote Condensing FC=277/1/60 010 W= Water Cooled KA= 480/3/60 014 F= Water Cooled with Multicool 017 Configuration Voltage Air Pattern A= Air Cooled BC=208-230/1/60 S=Spot Cooled E= Air Cooled with Multicool BA= 208-230/3/60 D=Ducted G=Glycol Cooled B= Glycol Cooled with Multicool P= Glycol Cooled with Economizer C= Chilled Water CM XXX X APC NetworkAIR™ CM XX X i ii APC NetworkAIR™ CM Overview The APC NetworkAIR CM computer room air conditioning system offers an increasingly compact, modular, and reliable system solution without consuming valuable floor space. Precision environmental requirements now reach far beyond the confines of the traditional data center or computer room to encompass a larger suite of applications, referred to as technology rooms. Critical environment applications include: • Computer rooms • Telecommunication facilities • Clean rooms • Power equipment Room Air Distribution The spot-cooled configuration is supplied with a 2’ x 4’ (610mm x 1220mm) supply/return air filter assembly. The filter assembly includes one-way supply and return air grilles. Available on 3-10kW (13 ton) units only. Standard Features • Scroll & Hermetic Reciprocating Compressors • Centrifugal Blower Assembly • Heavy Gauge Steel Frame • Thermostat/Humidistat Controller Optional Features The duct configuration is supplied with a 1” (25mm) duct flange on the supply and return air openings. • 2 or 3 Way Fluid Regulating Valves (Glycol/Water/ Economizer) • Chilled Water Control Valve Configuration • Tube in tube coaxial condenser (310kW (1-3 ton) Glycol/Water) • Glycol Cooled • Glycol Cooled with Economizer • Glycol Cooled with MultiCool (Chilled Water Coil) • Water Cooled • Brazed plate condenser (14-17kW (4-5 ton) Glycol/Water) • Microprocessor w/Remote Display • Remote Sensor • Water Cooled with MultiCool (Chilled Water Coil) • Redundant Group Control • Medical equipment rooms • Archives • Air Cooled • Pure Steam Canister Humidifier • LAN/WAN environments • Air Cooled with MultiCool (Chilled Water Coil) • 30%, 1” Deep Filters • Air Cooled with Remote Condensing • Hot Water Reheat A worldwide network of APC representatives is fully qualified to provide engineering, sales, installation and service for our products. APC warrants all parts for 12 months from shipment. Extended warranties are available. Capacity CM is available from 3-17 kW (1-5 ton) in direct expansion and chilled water. • Chilled Water • Programmable Thermostat • Electric Reheat • Hot Gas Reheat (Water/Glycol) • Hot Gas Bypass (N/A on Chilled Water systems) Compliance Approval • ETL/CETL • UL Listed to UL 1995 and CSA C22.2 No. 236 • MEA #256-94-E (5, 7, 10, 17 kW), #177-01-E (3, 14 kW) (City of New York) • • • • Ship Loose Spot Water Detector Ship Loose Firestat Ship Loose Smoke Detector Ship Loose Condensate Pump • Reheat/Humidity Lockout • Environmental Monitoring • Remote Relay Shutdown • OHE Disconnect • ModBus/JBus Gateway • Fused Ship-Loose Disconnect C APC NetworkAIR™ CM US • Optional HP Motor 1 Standard Features Cabinet The frame is constructed of heavy gauge steel for maximum strength. Hanger mounting brackets shall be part of the chassis and shock mounts are provided for vibration isolation. The unit offers service access to all components through removable access panels lined with 1/2” thick insulation. Please allow 36” (914mm) on all sides for accessibility. Fan/Motor Section The air distribution system for the 3-10kW (1-3 ton) units is comprised of a direct-drive fan motor with a double-inlet blower and permanently sealed ball-bearing type blower bearings. The air distribution system for the 14-17kW (4-5 ton) units has a belt drive fan motor with a double-inlet blower and permanently sealed ball-bearing type blower bearings. Evaporator Coil & Drain Pan The evaporator coil is constructed of copper tubes and aluminum fins and is mounted in a stainless steel condensate drain pan. The condensate drain pan is equipped with dual condensate overflow switches that will automatically shut-down the equipment if the condensate drain becomes clogged. 2 Chilled Water Coil The cooling coil is constructed of copper tubes and aluminum fins and is mounted over a stainless steel condensate drain pan. The coil circuiting ensures water distribution over the entire coil face area. Electrical Panel The electrical panel contains the contactors, starters, overload protection devices, and input power disconnects. Each wire (except jumpers) is numbered every 3” (80mm), or color coded to facilitate circuit tracing when installing and servicing the unit. Each AC power circuit is individually branch circuit fused on all three phases. All compressor and motor devices are thermally and short circuit protected. The electrical panel is easily accessible from the front of the unit. All electrical components are ULlisted and -recognized and all wiring conforms to NFPA 70 (NEC) and UL 1995 requirements. APC NetworkAIR™ CM Refrigeration System and Compressor The refrigeration system consists of a single hermetic compressor, externally equalized expansion valve, filter-dryer, high pressure switch, refrigerant sight glass, and moisture indicator. Thermostat Controller The unit control provides two separate heat and cool temperature setpoints with a minimum 2 degree spacing between them. The controller shall activate heating or cooling functions automatically in regard to setpoint versus measured conditions. The control setpoint range shall be 60-80°F (15-27°C). Units requiring humidity control have separate humidity and dehumidity setpoints with a minimum 4% RH spacing between them. The controller activates humidifying or dehumidifying cycles as a function of setpoint versus measured return air conditions. The humidity setpoint range shall be 20% RH or 80% RH. As an option, the control shall also allow daily or 5 day/2 day program scheduling at a maximum of two programs per day. Optional Features Air Filter The filtration of conditioned air is extremely vital to maintaining the clean, particle-free environment required by electrical equipment. The CM system uses 30% efficient, 1” deep filters, with full depth filter pleats. Filters are easily replaced on all CM model configurations. Humidifier The humidifier utilizes a pure steam generator specifically designed for hi-tech area environmental control. The pure steam eliminates contaminating mineral deposits, bacteria, white dust and excessive humidity. The humidifier requires little or no scheduled maintenance. Automatic flushing combined with an indicator that signals when the canister is to be changed, ensure maintenance free operation. Electric Reheat The electrical resistance heater is sized to offset the sensible cooling capacity in the dehumidification mode. The reheat elements are low watt density finned tubular on the 35kW (1-1.5 ton) systems. Open coil resistance type are used on the 717kW (2-5 ton) systems. Reheat elements are electrically and thermally protected. Condenser The 3-10kW (1-3 ton) water- and glycol-cooled systems employ a coaxial style condenser that uses efficient tube within a tube counterflow heat transfer to remove the heat of compression. Water flows through the inner tube while refrigerant flows in the cavity between the inner copper tube and outer steel tube. The convoluted tubes enhance thermal performance while inhibiting the accumulation of deposits. Water-Regulating Valve Water and Glycol systems maintain proper performance by sensing refrigerant discharge pressure and regulating the among of water or glycol supplied to the condenser. A two-way or three-way valve is available. The standard valve pressure rating is 150 psi (1030kPa). Valves with a pressure rating of 350 psi (2413 kPa) ship loose for field installation. Space restrictions within the cabinet prevent the valves from being factory installed when reheat and humidity are selected. Redundant Group Control Allows up to six NetworkAIR units the ability to communicate with each other to automatically switch upon alarm condition, or timed rotation. Can also allow standby units the ability to assist the running system. Chilled Water Control Valve Cooling capacity shall be controlled with a slow-close, 2-way, motorized valve rated for 125 psi (862 kPa). Hot Gas Reheat Hot gas reheat is optional on waterand glycol-cooled systems. The copper tube, aluminum fin hot gas reheat coil maintains the leaving dry bulb temperature when the system is in dehumidification mode. The coil is controlled by the processor through a factory piped and wired three-way heat reclaim regulator and check valve. Remote Relay Shutdown Shutdown of the NetworkAIR system can be done remotely by a factory installed relay. The relay can be ordered with a 24V, 120V, or 240V coil. The relay must be powered by others to disable the NetworkAIR system. Reheat/Humidity Lockout When facilities have limited backup power capacity, this lockout prevents the operation of electrical loads that are not essential for continued site operation. Programmable Thermostat A wall-mount programmable thermostat with LCD display, sevenday programming, and battery back-up will provide temperature control. When equipped with a humidifier and/or reheat, a hair element humidistat/dehumidistat supplies humidification and or dehumidification control. APC NetworkAIR™ CM Remote Sensor(s) Environmental sensor(s) can be strategically placed, up to 50ft. from the unit to better meet the site’s cooling needs. The sensor must be positioned to permit air movement across the sensors. Hot Water Reheat (Modulating) A modulating control valve controls hot water reheat. The system is supplied with a factory-installed copper tube and an aluminum fin hot water coil. Option not available on MultiCool models. Hot Water Reheat (2-Way On/ Off) An on/off solenoid valve maintains the dry bulb temperature when the system is in dehumidification and reheat mode. Completely factory pre-piped, the system includes a copper tube, aluminum fin reheat coil, float, and thermostatic steam trap. 3 Optional Features Optional Blower/Motor HP An optional 5HP motor can be used for increased CFM or to accommodate special air filters, high external static pressure, etc. while maintaining the standard CFM rating. Ship Loose Condensate Pump The condensate pump, shipped loose, will pump 36 gal/h (0.06 L/s) at 15 ft. (4.6 m) head. Condensate pump must be mounted to the outside of the unit. ModBus/JBus Gateway The Gateway translates transmission protocol from the system’s network into ModBus/JBus communication protocol. One gateway can support up to 16 units. Fused Disconnect A Nema 1 fused disconnect, complete with fuses, will ship loose for field installation, thus allowing the disconnect to be unit-mounted or remotely located. Ship Loose Smoke Detector The smoke detector is designed to sense smoke in the return air stream. Upon detection of smoke, an audible and visual alarm on the microprocessor will be activated and the unit will be immediately shutdown. Smoke detector ships loose for field installation. Smoke detector must be mounted externally, near the return air grille on spot cooled units and in the duct work in ducted configurations. OHE Disconnect A non-fused disconnect switch may be wired to an outdoor heat exchanger to disconnect high voltage power if necessary. Hot Gas Bypass An auxiliary side-port hot gas bypass circuit maintains the evaporator coil temperature during low load conditions. This optional feature will offer longer compressor run times and minimize compressor cycling and temperature fluctuations. Ship Loose Spot Water Detector(s) The solid-state spot water detector activates an audible alarm on the controller when moisture is detected. A maximum of four detectors may be installed. Spot water detector ships loose for field installation. Spot water detector must be mounted externally. Ship Loose Firestat A firestat ships loose for field installation in the air stream of the unit. If the return air temperature reaches 125°F (52°C), an audible and visual alarm on the microprocessor will be activated and the unit will immediately shutdown. Firestat must be mounted externally, near the return air grille on spot cooled units and in the duct work in ducted configurations. 4 MultiCool MultiCool systems contain a chilled water coil and direct expansion coil within the same cabinet. Either cooling coil can be used as a backup to the other. These systems provide cooling using either building chilled water and/or the direct expansion system. Economizer Glycol and water cooled systems may be optionally configured with an economizer coil. During cold ambient conditions, the compressorized system will shut-down and utilize the cold outdoor air to cool the glycol system, rerouting it from the heat exchanger to the economizer coil for efficient operation. APC NetworkAIR™ CM Environmental Monitoring Unit A stand-alone unit performs contact monitoring and continuous temperature and humidity sensing through two probes (one included). The unit is controlled by available web, control console, or SNMP interface with a network connection. In the event of an environmental anomaly, notification is sent via e-mail or SNMP. The unit is 18.25” x 9” x 2.75” (464mm x 229mm x 70mm). The probes extend up to 12’ (3.66m) from the unit. Environmental Management System A browser-accessible, 1U, rackmountable appliance allows monitoring of environmental conditions. Monitoring of one temperature, one humidity, and one vibration sensor ship standard. When conditions change, notifications are sent via email to appropriate personnel. The EMS provides 8 input contacts, 2 output relays, and controllable power outlets for defining actions remotely should conditions warrant it. Optional Microprocessor Controller Microprocessor Controller The microprocessor controller is standard on the main module of each system. The controller provides precision control for the demanding requirements of: • Data centers • Control rooms • Clean rooms • Switch rooms • UPS rooms The easy-to-use display allows the operator to select options from the device’s menu-driven interface to control and monitor the connected air conditioning system. Status Complete status monitoring is provided within the status menu of the microprocessor controller. Available information includes: • Current Temperature/Humidity • Temperature/Humidity Setpoint Automatic setpoint crossover protection will prevent the setting of the heat setpoint above the cool setpoint and the humidification setpoint above the dehumidification setpoint. Setpoint adjustment can be restricted to only operators with knowledge of the security codes set within the security menu structure. Configuration Flexibility is offered through the use of the configuration menu. Operating requirements are satisfied by changing the configuration settings. New configurations are stored in EEPROM and protected from unauthorized tampering by the four-digit security password, selected in the security menu. Configuration options include: • Fahrenheit or celsius display • Compressor minimum on/off time • Power loss restart time delay • Redundant unit grouping • Cooling/Heating Status • Alarm input polarity • Humidification/Dehumidification Status • Alarm enable Alarms Quick access to any alarm condition is facilitated through the menu structure. The alarm key acts as a hot key providing immediate access to the alarm display menu. Presence of a new alarm will sound the audible alarm. The red alarm LED on the display panel will remain illuminated until all alarms have been cleared. The temperature and humidity alarm setpoints are adjustable. Alarm annunciations include: • Loss of airflow • Clogged filter • High head pressure • Low suction pressure • High/Low temperature • Temperature/Humidity deadbands • Small room delay Common Alarm Contact A common alarm relay is installed on every microprocessor. In the event of an alarm condition, the relay will change state. The user can select which alarms change the state of the relay. This feature allows for remote enunciation of alarm status. Run Times The major components within the unit have independent run timers that monitor and store accumulated run hours on the components. The run timers are provided with operator adjustable run time alarms. Security Multiple security levels prevent unauthorized adjustment of important system parameters. The user may select a four-digit password for setpoint and configuration changes. Should the password be forgotten, APC can provide temporary access. Monitoring With the addition of a supervisory network communications card the microprocessor may interface with the locally installed APC remote monitoring and control system. Gateways are available for interfacing with building management systems. Please check with APC for compatibility with your building management system. Cool Inhibit Prevents the unit from over-cooling during the dehumidification cycle. If the space temperature falls below a user adjustable setpoint, cooling will become inhibited until the space temperature returns to setpoint. Cool Override A manual toggle switch will allow the compressor to operate in the event of a microprocessor failure. The cool override can be field wired to a snap acting thermostat for cooling control. Remote Shutdown Events external to the unit, such as activation of a fire suppression system may require the unit to shut down remotely. Additionally this feature may be tied into a BMS that would allow remote control of the units on/off status. • High/Low humidity APC NetworkAIR™ CM 5 Performance Specifications—Air Cooled NET COOLING CAPACITY - BTU/HR (kW) 3kW (1 ton) 5kW (1.5ton) 7kW (2 ton) 10kW (3 ton) 80F DB, 67F WB (26.7C DB, 19.4C WB) 50% RH Total 15,000 (4.3) 18,000 (5.3) 24,000 (7.0) 34,000 (9.9) Sensible 13,000 (3.9) 15,000 (4.3) 19,000 (5.6) 26,000 (7.6) 75F DB, 62.5F WB (23.9C DB, 16.9C WB) 50% RH Total 14,000 (4.0) 17,000 (4.9) 21,000 (6.3) 32,000 (9.3) Sensible 12,000 (3.6) 14,000 (4.0) 19,000 (5.6) 26,000 (7.6) 75F DB, 61F WB (23.9C DB, 16.1C WB) 45% RH Total 13,000 (3.9) 16,000 (4.6) 22,000 (6.6) 31,000 (9.0) Sensible 13,000 (3.9) 16,000 (4.6) 21,000 (6.3) 28,000 (8.0) 72F DB, 60F WB (22.2C DB, 15.5C WB) 50% RH Total 13,000 (3.9) 16,000 (4.6) 21,000 (6.3) 30,000 (8.9) Sensible 12,000 (3.6) 14,000 (4.0) 19,000 (5.6) 25,000 (7.3) 72F DB, 58.6 WB (22.2D DB, 14.8C WB) 45% RH Total 13,000 (3.9) 16,000 (4.6) 21,000 (6.3) 30,000 (8.9) Sensible 13,000 (3.9) 15,000 (4.3) 20,000 (5.9) 27,000 (7.9) 70F DB, 58.5F WB (21.1C DB, 14.8C WB) 50% RH Total 12,000 (3.6) 15,000 (4.3) 21,000 (6.3) 29,000 (8.6) Sensible 12,000 (3.6) 14,000 (4.0) 18,000 (5.3) 25,000 (7.3) 70F DB, 57.2F WB (21.1C DB, 14.0C WB) 45% RH Total 12,000 (3.6) 15,000 (4.3) 20,000 (6.0) 29,000 (8.6) Sensible 12,000 (3.6) 15,000 (4.3) 20,000 (6.0) 27,000 (8.0) MULTICOOL -- COOLING CAPACITY DATA -- BTU/HR (kW) - 45F (7.2C) EWT 80F DB, 67F WB (26.7C DB, 19.4C WB) 50% RH Total - BTU/HR (kW) 20,000 (5.9) 22,000 (6.6) 37,000 (10.9) 46,000 (13.6) Sensible - BTU/HR (kW) 15,000 (4.3) 17,000 (4.9) 26,000 (7.6) 33,000 (9.6) Flow Rate - GPM (L/s) 4.1 (0.3) 4.4 (0.3) 10.7 (0.7) 9.4 (0.6) Pressure Drop - psig (kPa) 5.6 (38.6) 6.5 (44.8) 7.5 (51.7) 8.6 (59.3) 75F DB, 62.5F WB (23.9C DB, 16.9C WB) 50% RH Total - BTU/HR (kW) 15,000 (4.3) 16,000 (4.6) 27,000 (8.0) 34,000 (9.9) Sensible - BTU/HR (kW) 14,000 (4.0) 15,000 (4.3) 23,000 (6.9) 29,000 (8.6) Flow Rate - GPM (L/s) 3.0 (0.2) 3.3 (0.2) 5.5 (0.3) 6.9 (0.4) Pressure Drop - psig (kPa) 3.1 (21.4) 3.7 (25.5) 4.2 (29.0) 4.8 (33.1) 75F DB, 61F WB (23.9C DB, 16.1C WB) 45% RH Total - BTU/HR (kW) 14,000 (4.0) 16,000 (4.6) 26,000 (7.6) 33,000 (9.6) Sensible - BTU/HR (kW) 14,000 (4.0) 16,000 (4.6) 24,000 (7.0) 31,000 (9.0) Flow Rate - GPM (L/s) 2.9 (0.2) 3.2 (0.2) 5.2 (0.3) 6.6 (0.4) Pressure Drop - psig (kPa) 3.0 (20.7) 3.6 (24.8) 3.7 (25.5) 4.4 (30.3) 72F DB, 60F WB (22.2C DB, 15.5C WB) 50% RH Total - BTU/HR (kW) 13,000 (3.9) 14,000 (4.0) 23,000 (6.9) 29,000 (8.6) Sensible - BTU/HR (kW) 13,000 (3.9) 13,000 (3.9) 21,000 (6.3) 27,000 (7.9) Flow Rate - GPM (L/s) 2.5 (0.2) 2.8 (0.2) 4.6 (0.3) 5.8 (0.4) Pressure Drop - psig (kPa) 2.3 (15.9) 2.7 (18.6) 3.0 (20.7) 3.6 (24.8) 72F DB, 58.6 WB (22.2D DB, 14.8C WB) 45% RH Total - BTU/HR (kW) 13,000 (3.9) 14,000 (4.0) 22,000 (6.6) 28,000 (8.3) Sensible - BTU/HR (kW) 13,000 (3.9) 14,000 (4.0) 21,000 (6.3) 27,000 (7.9) Flow Rate - GPM (L/s) 2.5 (0.2) 2.8 (0.2) 4.4 (0.3) 5.6 (0.4) Pressure Drop - psig (kPa) 2.3 (15.9) 2.7 (18.6) 2.7 (18.6) 3.3 (22.8) 70F DB, 58.5F WB (21.1C DB, 14.8C WB) 50% RH Total - BTU/HR (kW) 11,000 (3.3) 12,000 (3.6) 20,000 (6.0) 26,000 (7.6) Sensible - BTU/HR (kW) 11,000 (3.3) 12,000 (3.6) 19,000 (5.6) 25,000 (7.3) Flow Rate - GPM (L/s) 2.3 (0.1) 2.5 (0.2) 4.1 (0.3) 5.2 (0.3) Pressure Drop - psig (kPa) 1.9 (13.1) 2.2 (15.2) 2.4 (16.5) 2.9 (20.0) 70F DB, 57.2F WB (21.1C DB, 14.0C WB) 45% RH Total - BTU/HR (kW) 12,000 (3.6) 12,000 (3.6) 20,000 (6.0) 25,000 (7.3) Sensible - BTU/HR (kW) 12,000 (3.6) 12,000 (3.6) 20,000 (6.0) 25,000 (7.3) Flow Rate - GPM (L/s) 2.3 (0.1) 2.5 (0.2) 4.0 (0.3) 5.1 (0.3) Pressure Drop - psig (kPa) 1.9 (13.1) 2.2 (15.2) 2.3 (15.9) 2.7 (18.6) AIR SYSTEM -- BELT DRIVE CENTRIFUGAL Air Volume -- CFM (L/s) 625 (295) 700 (330) 900 (425) 1,200 (566) Blower Motor -- HP (kW) 0.25 (0.2) 0.25 (0.2) 0.25 (0.2) 0.50 (0.4) External Static Pressure -- inches of water (Pa) 0.3 (75) 0.3 (75) 0.3 (75) 0.3 (75) Number of Blowers 1 1 1 1 COMPRESSOR EER 7.9 12.5 12.9 13.7 Quantity 1 1 1 1 Nominal HP (kW) 1.0 (0.75) 1.5 (1.13) 2.0 (1.50) 3.0 (2.26) 6 APC NetworkAIR™ CM 14kW (4 ton) 17kW (5 ton) 49,000 (14.3) 56,000 (16.6) 41,000 (11.9) 47,000 (13.9) 45,000 (13.3) 52,000 (15.3) 41,000 (11.9) 47,000 (13.9) 45,000 (13.3) 55,000 (16.3) 44,000 (13.0) 52,000 (15.3) 43,000 (12.6) 50,000 (14.6) 40,000 (11.6) 45,000 (13.3) 45,000 (13.3) 50,000 (14.6) 45,000 (13.3) 49,000 (14.3) 44,000 (13.0) 49,000 (14.3) 42,000 (12.3) 45,000 (13.3) 44,000 (13.0) 48,000 (14.0) 44,000 (13.0) 47,000 (13.9) 75,000 (21.9) 82,000 (23.9) 54,000 (15.9) 60,000 (17.6) 15.0 (0.9) 16.5 (1.0) 10.1 (69.6) 12.1 (83.4) 55,000 (16.3) 60,000 (17.6) 47,000 (13.9) 53,000 (15.6) 11.0 (0.7) 12.2 (0.8) 5.6 (38.6) 6.8 (46.9) 52,000 (15.3) 58,000 (17.0) 49,000 (14.3) 55,000 (16.3) 10.6 (0.7) 11.8 (0.7) 5.2 (35.9) 6.4 (44.1) 46,000 (13.6) 51,000 (14.9) 43,000 (12.6) 48,000 (14.0) 9.2 (0.6) 10.3 (0.6) 4.0 (17.6) 4.9 (33.8) 44,000 (12.9) 49,000 (14.3) 43,000 (12.6) 49,000 (14.3) 8.9 (0.6) 9.9 (0.6) 3.7 (25.5) 4.6 (31.7) 41,000 (11.9) 44,000 (12.9) 39,000 (11.3) 43,000 (12.6) 8.2 (0.5) 8.9 (0.6) 3.2 (22.1) 3.7 (25.5) 39,000 (11.3) 44,000 (12.9) 39,000 (11.3) 44,000 (12.9) 7.9 (0.5) 8.9 (0.6) 3.0 (20.7) 3.7 (25.5) 2,000 (944) 1.50 (1.1) 0.5 (125) 1 2,300 (1,086) 1.50 (1.1) 0.5 (125) 1 13.8 1 4.0 (3.01) 13.9 1 5.0 (3.76) Performance Specifications—Air Cooled Performance Specifications - Air Cooled CM (kW-tons) EVAPORATOR COIL -- SLAB 3kW (1 ton) 5kW (1.5ton) 7kW (2 ton) 10kW (3 ton) 14kW (4 ton) 17kW (5 ton) Face Area -- ft2 (m2) Rows Deep Face Velocity -- FPM (m/s) HUMIDIFICATION --- SOLID STATE ELECTRODE CANISTER Flush Cycle Capacity -- Lbs/hr (Kg/hr) kW FILTERS Quantity Size -- Inches (mm) 1.9 (0.17) 3 338 (1.72) 1.9 (0.17) 3 378 (1.92) 2.9 (0.27) 3 310 (1.57) 2.9 (0.27) 3 414 (2.10) 5.2 (0.48) 4 385 (1.96) 5.2 (0.48) 4 442 (2.25) automatic 5 (2.3) 1.7 automatic 5 (2.3) 1.7 automatic 5 (2.3) 1.7 automatic 5 (2.3) 1.7 automatic 10 (4.5) 3.4 automatic 10 (4.5) 3.4 1 20 x 20 (508 x 508) 1 (25) 1 20 x 20 (508 x 508) 1 (25) 1 20 x 20 (508 x 508) 1 (25) 1 20 x 20 (508 x 508) 1 (25) 2 16 x 25 (406 x 635) 1 (25) 2 16 x 25 (406 x 635) 1 (25) 10,000 (3.0) 1 19,000 (5.6) 1 20,000 (6.0) 1 26,000 (7.6) 1.5 (0.09) 0.7 (4.8) 31,000 (9.0) 2.0 (0.13) 1.2 (8.3) 39,000 (11.3) 50,000 (14.6) 55,000 (16.3) 3.0 (0.19) 3.0 (0.19) 3.5 (0.22) 2.4 (16.6) 2.4 (16.6) 3.1 (21.4) 280 (127) 18.0 (465) 49.0 (1245) 26.0 (673) 355 (161) 26.0 (673) 51.0 (1295) 26.0 (673) 380 (172) 26.0 (673) 51.0 (1295) 26.0 (673) 585 (265) 26.0 (673) 60.0 (1524) 38.0 (958) 585 (265) 26.0 (673) 60.0 (1524) 38.0 (958) 3/8 5/8 1/2 5/8 1/2 5/8 1/2 7/8 5/8 7/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 1/4 1/4 1/4 1/4 1/4 7/8 7/8 7/8 7/8 7/8 1/2 1/2 7/8 7/8 7/8 7/8 1-3/8 1-3/8 1-3/8 1-3/8 Depth -- Inches (mm) REHEAT Electric -- Equally Loaded on each phase, rated at 230V/1 and 203/3 Capacity -BTU/HR (kW) Includes Motor Heat 10,000 (3.0) Stages 1 Hot Water -- 180F (82.2C) EWT, 140F (63.9C) LWT Capacity - BTU/HR (kW) Includes Motor Heat 23,000 (6.9) GPM (L/s) 1.0 (0.06) Pressure Drop -- PSI (kPA) 0.3 (2.1) PHYSICAL DATA Weight -- lbs (kg) 280 (127) Height -- Inches (mm) 18.0 (465) Length -- Inches (mm) 49.0 (1245) Depth -- Inches (mm) 26.0 (673) CONNECTION SIZES* Air Liquid Line -- inches OD 3/8 Discharge Line -- inches OD 5/8 Hot Water Supply Line -- inches OD 5/8 Return Line -- inches OD 5/8 Humidifier Supply Line -- inches OD 1/4 Condensate Drain Drain Line -- inches ID 7/8 MultiCool Supply Line -- inches OD 1/2 Return Line -- inches OD 1/2 *Connection sizes, not recommended piping sizes APC NetworkAIR™ CM 39,000 (11.3) 39,000 (11.3) 2 2 7 Performance Specifications—Water Cooled NET COOLING CAPACITY - BTU/HR (kW) 3kW (1 ton) 5kW (1.5ton) 7kW (2 ton) 10kW (3 ton) 80F DB, 67F WB (26.7C DB, 19.4C WB) 50% RH Total 16,000 (4.6) 21,000 (6.3) 26,000 (7.6) 43,000 (12.6) Sensible 13,000 (3.9) 16,000 (4.6) 20,000 (6.0) 37,000 (10.6) 75F DB, 62.5F WB (23.9C DB, 16.9C WB) 50% RH Total 15,000 (4.3) 20,000 (6.0) 24,000 (7.0) 34,000 (9.9) Sensible 13,000 (3.9) 16,000 (4.6) 20,000 (6.0) 27,000 (8.0) 75F DB, 61F WB (23.9C DB, 16.1C WB) 45% RH Total 15,000 (4.3) 19,000 (5.6) 23,000 (6.9) 33,000 (9.6) Sensible 14,000 (4.0) 17,000 (4.9) 21,000 (6.3) 29,000 (8.6) 72F DB, 60F WB (22.2C DB, 15.5C WB) 50% RH Total 14,000 (4.0) 19,000 (5.6) 23,000 (6.9) 33,000 (9.6) Sensible 13,000 (3.9) 16,000 (4.6) 19,000 (5.6) 27,000 (8.0) 72F DB, 58.6 WB (22.2D DB, 14.8C WB) 45% RH Total 14,000 (4.0) 19,000 (5.6) 22,000 (6.6) 32,000 (9.3) Sensible 14,000 (4.0) 17,000 (4.9) 21,000 (6.3) 29,000 (8.6) 70F DB, 58.5F WB (21.1C DB, 14.8C WB) 50% RH Total 14,000 (4.0) 18,000 (5.3) 22,000 (6.6) 32,000 (9.3) Sensible 12,000 (3.6) 15,000 (4.3) 19,000 (5.6) 26,000 (7.6) 70F DB, 57.2F WB (21.1C DB, 14.0C WB) 45% RH Total 14,000 (4.0) 18,000 (5.3) 22,000 (6.6) 31,000 (9.0) Sensible 13,000 (3.9) 16,000 (4.6) 20,000 (6.0) 28,000 (8.3) MULTICOOL -- COOLING CAPACITY DATA -- BTU/HR (kW) - 45 F (7.2 C) EWT 80F DB, 67F WB (26.7C DB, 19.4C WB) 50% RH Total - BTU/HR (kW) 20,000 (5.9) 22,000 (6.6) 37,000 (10.9) 46,000 (13.6) Sensible - BTU/HR (kW) 15,000 (4.3) 17,000 (4.9) 26,000 (7.6) 33,000 (9.6) Flow Rate - GPM (L/s) 4.1 (0.3) 4.4 (0.3) 10.7 (0.7) 9.4 (0.6) Pressure Drop - psig (kPa) 5.6 (38.6) 6.5 (44.8) 7.5 (51.7) 8.6 (59.3) 75F DB, 62.5F WB (23.9C DB, 16.9C WB) 50% RH Total - BTU/HR (kW) 15,000 (4.3) 16,000 (4.6) 27,000 (8.0) 34,000 (9.9) Sensible - BTU/HR (kW) 14,000 (4.0) 15,000 (4.3) 23,000 (6.9) 29,000 (8.6) Flow Rate - GPM (L/s) 3.0 (0.2) 3.3 (0.2) 5.5 (0.3) 6.9 (0.4) Pressure Drop - psig (kPa) 3.1 (21.4) 3.7 (25.5) 4.2 (29.0) 4.8 (33.1) 75F DB, 61F WB (23.9C DB, 16.1C WB) 45% RH Total - BTU/HR (kW) 14,000 (4.0) 16,000 (4.6) 26,000 (7.6) 33,000 (9.6) Sensible - BTU/HR (kW) 14,000 (4.0) 16,000 (4.6) 24,000 (7.0) 31,000 (9.0) Flow Rate - GPM (L/s) 2.9 (0.2) 3.2 (0.2) 5.2 (0.3) 6.6 (0.4) Pressure Drop - psig (kPa) 3.0 (20.7) 3.6 (24.8) 3.7 (25.5) 4.4 (30.3) 72F DB, 60F WB (22.2C DB, 15.5C WB) 50% RH Total - BTU/HR (kW) 13,000 (3.9) 14,000 (4.0) 23,000 (6.9) 29,000 (8.6) Sensible - BTU/HR (kW) 13,000 (3.9) 13,000 (3.9) 21,000 (6.3) 27,000 (7.9) Flow Rate - GPM (L/s) 2.5 (0.2) 2.8 (0.2) 4.6 (0.3) 5.8 (0.4) Pressure Drop - psig (kPa) 2.3 (15.9) 2.7 (18.6) 3.0 (20.7) 3.6 (24.8) 72F DB, 58.6 WB (22.2D DB, 14.8C WB) 45% RH Total - BTU/HR (kW) 13,000 (3.9) 14,000 (4.0) 22,000 (6.6) 28,000 (8.3) Sensible - BTU/HR (kW) 13,000 (3.9) 14,000 (4.0) 21,000 (6.3) 27,000 (7.9) Flow Rate - GPM (L/s) 2.5 (0.2) 2.8 (0.2) 4.4 (0.3) 5.6 (0.4) Pressure Drop - psig (kPa) 2.3 (15.9) 2.7 (18.6) 2.7 (18.6) 3.3 (22.8) 70F DB, 58.5F WB (21.1C DB, 14.8C WB) 50% RH Total - BTU/HR (kW) 11,000 (3.3) 12,000 (3.6) 20,000 (6.0) 26,000 (7.6) Sensible - BTU/HR (kW) 11,000 (3.3) 12,000 (3.6) 19,000 (5.6) 25,000 (7.3) Flow Rate - GPM (L/s) 2.3 (0.1) 2.5 (0.2) 4.1 (0.3) 5.2 (0.3) Pressure Drop - psig (kPa) 1.9 (13.1) 2.2 (15.2) 2.4 (16.5) 2.9 (20.0) 70F DB, 57.2F WB (21.1C DB, 14.0C WB) 45% RH Total - BTU/HR (kW) 12,000 (3.6) 12,000 (3.6) 20,000 (6.0) 25,000 (7.3) Sensible - BTU/HR (kW) 12,000 (3.6) 12,000 (3.6) 20,000 (6.0) 25,000 (7.3) Flow Rate - GPM (L/s) 2.3 (0.1) 2.5 (0.2) 4.0 (0.3) 5.1 (0.3) Pressure Drop - psig (kPa) 1.9 (13.1) 2.2 (15.2) 2.3 (15.9) 2.7 (18.6) COOLANT REQUIREMENTS THR -- MBH (kW) 23,000 (6.9) 28,000 (8.3) 34,000 (9.9) 49,000 (14.3) 65 F (18.3 C) Water In -- GPM (L/s) 1.0 (0.06) 1.3 (0.08) 1.8 (0.11) 2.3 (0.15) Pressure Drop -- psig (kPa) 1.9 (13.1) 1.6 (11.0) 1.6 (11.0) 1.8 (12.4) 75 F (23.9 C) Water In -- GPM (L/s) 1.5 (0.09) 1.9 (0.12) 2.8 (0.18) 3.6 (0.23) Pressure Drop -- psig (kPa) 3.3 (22.8) 1.9 (13.1) 2.6 (17.9) 2.3 (15.9) 85 F (29.4 C) Water In -- GPM (L/s) 2.9 (0.18) 3.9 (0.24) 6.4 (0.40) 8.4 (0.53) Pressure Drop -- psig (kPa) 2.8 (19.3) 5.2 (35.9) 3.7 (25.5) 9.3 (64.1) 8 APC NetworkAIR™ CM 14kW (4 ton) 17kW (5 ton) 55,000 (16.3) 63,000 (18.3) 44,000 (13.0) 50,000 (14.6) 51,000 (14.9) 58,000 (17.0) 43,000 (12.6) 49,000 (14.3) 50,000 (14.6) 57,000 (16.9) 46,000 (13.6) 53,000 (15.6) 49,000 (14.3) 56,000 (16.6) 42,000 (12.3) 48,000 (14.0) 50,000 (14.6) 55,000 (16.3) 49,000 (14.3) 52,000 (15.3) 49,000 (14.3) 54,000 (15.9) 45,000 (13.3) 47,000 (13.9) 48,000 (14.0) 54,000 (15.9) 47,000 (13.9) 51,000 (14.9) 75,000 (21.9) 82,000 (23.9) 54,000 (15.9) 60,000 (17.6) 15.0 (0.9) 16.5 (1.0) 10.1 (69.6) 12.1 (83.4) 55,000 (16.3) 60,000 (17.6) 47,000 (13.9) 53,000 (15.6) 11.0 (0.7) 12.2 (0.8) 5.6 (38.6) 6.8 (46.9) 52,000 (15.3) 58,000 (17.0) 49,000 (14.3) 55,000 (16.3) 10.6 (0.7) 11.8 (0.7) 5.2 (35.9) 6.4 (44.1) 46,000 (13.6) 51,000 (14.9) 43,000 (12.6) 48,000 (14.0) 9.2 (0.6) 10.3 (0.6) 4.0 (17.6) 4.9 (33.8) 44,000 (12.9) 49,000 (14.3) 43,000 (12.6) 49,000 (14.3) 8.9 (0.6) 9.9 (0.6) 3.7 (25.5) 4.6 (31.7) 41,000 (11.9) 44,000 (12.9) 39,000 (11.3) 43,000 (12.6) 8.2 (0.5) 8.9 (0.6) 3.2 (22.1) 3.7 (25.5) 39,000 (11.3) 44,000 (12.9) 39,000 (11.3) 44,000 (12.9) 7.9 (0.5) 8.9 (0.6) 3.0 (20.7) 3.7 (25.5) 71,000 (20.9) 81,000 (23.6) 3.8 (0.24) 4.4 (0.28) 2.3 (15.9) 2.8 (19.3) 5.5 (0.35) 6.5 (0.41) 2.9 (20.0) 3.4 (23.4) 10.8 (0.68) 14.0 (0.88) 9.1 (62.7) 11.1 (76.5) Performance Specifications—Water Cooled Performance Specifications—Water Cooled CM (kW-tons) WATER REGULATING VALVES Size -- 2 Way Ball Valve -- Inches, NPT (Cv)* AIR SYSTEM -- BELT DRIVE CENTRIFUGAL Air Volume -- CFM (L/s) Blower Motor -- HP (kW) External Static Pressure -- inches of water (Pa) Number of Blowers COMPRESSOR EER Quantity Nominal HP (kW) EVAPORATOR COIL -- SLAB Face Area -- ft2 (m2) Rows Deep Face Velocity -- FPM (m/s) HUMIDIFICATION --- SOLID STATE ELECTRODE CANISTER Flush Cycle Capacity -- Lbs/hr (Kg/hr) kW FILTERS Quantity Size -- Inches (mm) 3kW (1 ton) 5kW (1.5ton) 7kW (2 ton) 10kW (3 ton) 14kW (4 ton) 17kW (5 ton) 1/2 (7) 1/2 (7) 1/2 (7) 3/4 (10) 1 (12) 1 (12) 625 (295) 0.25 (0.2) 0.3 (75) 1 700 (330) 0.25 (0.2) 0.3 (75) 1 900 (425) 0.25 (0.2) 0.3 (75) 1 1,200 (566) 0.50 (0.4) 0.3 (75) 1 2,000 (944) 1.50 (1.1) 0.5 (125) 1 2,300 (1,086) 1.50 (1.1) 0.5 (125) 1 9.7 1 1.0 (0.75) 16.1 1 1.5 (1.13) 16.5 1 2.0 (1.50) 18.0 1 3.0 (2.26) 18.0 1 4.0 (3.01) 18.0 1 5.0 (3.76) 1.9 (0.17) 3 338 (1.72) 1.9 (0.17) 3 378 (1.92) 2.9 (0.27) 3 310 (1.57) 2.9 (0.27) 3 414 (2.10) 5.2 (0.48) 4 385 (1.96) 5.2 (0.48) 4 442 (2.25) automatic 5 (2.3) 1.7 automatic 5 (2.3) 1.7 automatic 5 (2.3) 1.7 automatic 5 (2.3) 1.7 automatic 10 (4.5) 3.4 automatic 10 (4.5) 3.4 1 20 x 20 (508 x 508) 1 (25) 1 20 x 20 (508 x 508) 1 (25) 1 20 x 20 (508 x 508) 1 (25) 1 20 x 20 (508 x 508) 1 (25) 2 16 x 25 (406 x 635) 1 (25) 2 16 x 25 (406 x 635) 1 (25) 10,000 (3.0) 1 19,000 (5.6) 1 20,000 (6.0) 1 26,000 (7.6) 1.5 (0.09) 0.7 (4.8) 31,000 (9.0) 2.0 (0.13) 1.2 (8.3) 39,000 (11.3) 50,000 (14.6) 55,000 (16.3) 3.0 (0.19) 3.0 (0.19) 3.5 (0.22) 2.4 (16.6) 2.4 (16.6) 3.1 (21.4) 14,000 (4.0) 16,000 (4.6) 20,000 (6.0) 26,000 (7.6) 27,000 (7.9) 280 (127) 18.0 (465) 49.0 (1245) 26.0 (673) 355 (161) 26.0 (673) 51.0 (1295) 26.0 (673) 380 (172) 26.0 (673) 51.0 (1295) 26.0 (673) 585 (265) 26.0 (673) 60.0 (1524) 38.0 (958) 585 (265) 26.0 (673) 60.0 (1524) 38.0 (958) 5/8 3/4 7/8 1-3/8 1-3/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 1/4 1/4 1/4 1/4 1/4 7/8 7/8 7/8 7/8 7/8 1/2 1/2 7/8 7/8 7/8 7/8 1-3/8 1-3/8 1-3/8 1-3/8 Depth -- Inches (mm) REHEAT Electric -- Equally Loaded on each phase, rated at 230V/1 and 203/3 Capacity -BTU/HR (kW) Includes Motor Heat 10,000 (3.0) Stages 1 Hot Water -- 180F (82.2C) EWT, 140F (63.9C) LWT Capacity - BTU/HR (kW) Includes Motor Heat 23,000 (6.9) GPM (L/s) 1.0 (0.06) Pressure Drop -- PSI (kPA) 0.3 (2.1) Hot Gas Reheat Capacity -- BTU/HR (kW) Includes Motor Heat 13,000 (3.9) PHYSICAL DATA Weight -- lbs (kg) 280 (127) Height -- Inches (mm) 18.0 (465) Length -- Inches (mm) 49.0 (1245) Depth -- Inches (mm) 26.0 (673) CONNECTION SIZES** Water In/Out -- Inches OD 5/8 Hot Water Supply Line -- Inches OD 5/8 Return Line -- Inches OD 5/8 Humidifier Supply Line -- Inches OD 1/4 Condensate Drain Drain Line -- Inches ID 7/8 MultiCool Supply Line -- Inches OD 1/2 Return Line -- Inches OD 1/2 *2-Way Single Seated, 400 psig W.W.P. max **Connection sizes, not recommended piping sizes APC NetworkAIR™ CM 39,000 (11.3) 39,000 (11.3) 2 2 9 Performance Specifications—Glycol Cooled NET COOLING CAPACITY - BTU/HR (kW) 3kW (1 ton) 5kW (1.5ton) 7kW (2 ton) 10kW (3 ton) 80F DB, 67F WB (26.7C DB, 19.4C WB) 50% RH Total 14,000 (4.0) 17,000 (4.9) 23,000 (6.9) 32,000 (9.3) Sensible 12,000 (3.6) 14,000 (4.0) 19,000 (5.6) 26,000 (7.6) 75F DB, 62.5F WB (23.9C DB, 16.9C WB) 50% RH Total 13,000 (3.9) 16,000 (4.6) 22,000 (6.6) 31,000 (9.0) Sensible 12,000 (3.6) 14,000 (4.0) 19,000 (5.6) 26,000 (7.6) 75F DB, 61F WB (23.9C DB, 16.1C WB) 45% RH Total 13,000 (3.9) 16,000 (4.6) 21,000 (6.3) 30,000 (8.9) Sensible 13,000 (3.9) 15,000 (4.3) 20,000 (6.0) 27,000 (7.9) 72F DB, 60F WB (22.2C DB, 15.5C WB) 50% RH Total 12,000 (3.6) 15,000 (4.3) 21,000 (6.3) 29,000 (8.6) Sensible 12,000 (3.6) 14,000 (4.0) 18,000 (5.3) 25,000 (7.3) 72F DB, 58.6 WB (22.2D DB, 14.8C WB) 45% RH Total 12,000 (3.6) 15,000 (4.3) 20,000 (6.0) 29,000 (8.6) Sensible 12,000 (3.6) 15,000 (4.3) 20,000 (6.0) 28,000 (8.3) 70F DB, 58.5F WB (21.1C DB, 14.8C WB) 50% RH Total 12,000 (3.6) 15,000 (4.3) 20,000 (6.0) 29,000 (8.6) Sensible 12,000 (3.6) 13,000 (3.9) 18,000 (5.3) 25,000 (7.3) 70F DB, 57.2F WB (21.1C DB, 14.0C WB) 45% RH Total 12,000 (3.6) 15,000 (4.3) 22,000 (6.6) 28,000 (8.3) Sensible 12,000 (3.6) 14,000 (4.0) 20,000 (6.0) 26,000 (7.6) MULTICOOL -- COOLING CAPACITY DATA -- BTU/HR (kW) - 45F (7.2C) EWT 80F DB, 67F WB (26.7C DB, 19.4C WB) 50% RH Total - BTU/HR (kW) 20,000 (5.9) 22,000 (6.6) 37,000 (10.9) 46,000 (13.6) Sensible - BTU/HR (kW) 15,000 (4.3) 17,000 (4.9) 26,000 (7.6) 33,000 (9.6) Flow Rate - GPM (L/s) 4.1 (0.3) 4.4 (0.3) 10.7 (0.7) 9.4 (0.6) Pressure Drop - psig (kPa) 5.6 (38.6) 6.5 (44.8) 7.5 (51.7) 8.6 (59.3) 75F DB, 62.5F WB (23.9C DB, 16.9C WB) 50% RH Total - BTU/HR (kW) 15,000 (4.3) 16,000 (4.6) 27,000 (8.0) 34,000 (9.9) Sensible - BTU/HR (kW) 14,000 (4.0) 15,000 (4.3) 23,000 (6.9) 29,000 (8.6) Flow Rate - GPM (L/s) 3.0 (0.2) 3.3 (0.2) 5.5 (0.3) 6.9 (0.4) Pressure Drop - psig (kPa) 3.1 (21.4) 3.7 (25.5) 4.2 (29.0) 4.8 (33.1) 75F DB, 61F WB (23.9C DB, 16.1C WB) 45% RH Total - BTU/HR (kW) 14,000 (4.0) 16,000 (4.6) 26,000 (7.6) 33,000 (9.6) Sensible - BTU/HR (kW) 14,000 (4.0) 16,000 (4.6) 24,000 (7.0) 31,000 (9.0) Flow Rate - GPM (L/s) 2.9 (0.2) 3.2 (0.2) 5.2 (0.3) 6.6 (0.4) Pressure Drop - psig (kPa) 3.0 (20.7) 3.6 (24.8) 3.7 (25.5) 4.4 (30.3) 72F DB, 60F WB (22.2C DB, 15.5C WB) 50% RH Total - BTU/HR (kW) 13,000 (3.9) 14,000 (4.0) 23,000 (6.9) 29,000 (8.6) Sensible - BTU/HR (kW) 13,000 (3.9) 13,000 (3.9) 21,000 (6.3) 27,000 (7.9) Flow Rate - GPM (L/s) 2.5 (0.2) 2.8 (0.2) 4.6 (0.3) 5.8 (0.4) Pressure Drop - psig (kPa) 2.3 (15.9) 2.7 (18.6) 3.0 (20.7) 3.6 (24.8) 72F DB, 58.6 WB (22.2D DB, 14.8C WB) 45% RH Total - BTU/HR (kW) 13,000 (3.9) 14,000 (4.0) 22,000 (6.6) 28,000 (8.3) Sensible - BTU/HR (kW) 13,000 (3.9) 14,000 (4.0) 21,000 (6.3) 27,000 (7.9) Flow Rate - GPM (L/s) 2.5 (0.2) 2.8 (0.2) 4.4 (0.3) 5.6 (0.4) Pressure Drop - psig (kPa) 2.3 (15.9) 2.7 (18.6) 2.7 (18.6) 3.3 (22.8) 70F DB, 58.5F WB (21.1C DB, 14.8C WB) 50% RH Total - BTU/HR (kW) 11,000 (3.3) 12,000 (3.6) 20,000 (6.0) 26,000 (7.6) Sensible - BTU/HR (kW) 11,000 (3.3) 12,000 (3.6) 19,000 (5.6) 25,000 (7.3) Flow Rate - GPM (L/s) 2.3 (0.1) 2.5 (0.2) 4.1 (0.3) 5.2 (0.3) Pressure Drop - psig (kPa) 1.9 (13.1) 2.2 (15.2) 2.4 (16.5) 2.9 (20.0) 70F DB, 57.2F WB (21.1C DB, 14.0C WB) 45% RH Total - BTU/HR (kW) 12,000 (3.6) 12,000 (3.6) 20,000 (6.0) 25,000 (7.3) Sensible - BTU/HR (kW) 12,000 (3.6) 12,000 (3.6) 20,000 (6.0) 25,000 (7.3) Flow Rate - GPM (L/s) 2.3 (0.1) 2.5 (0.2) 4.0 (0.3) 5.1 (0.3) Pressure Drop - psig (kPa) 1.9 (13.1) 2.2 (15.2) 2.3 (15.9) 2.7 (18.6) 10 APC NetworkAIR™ CM 14kW (4 ton) 17kW (5 ton) 47,000 (13.9) 55,000 (16.3) 40,000 (11.6) 46,000 (13.6) 44,000 (13.0) 51,000 (14.9) 40,000 (11.6) 46,000 (13.6) 44,000 (13.0) 51,000 (14.9) 43,000 (12.6) 49,000 (14.3) 42,000 (12.3) 49,000 (14.3) 39,000 (11.3) 45,000 (13.3) 44,000 (13.0) 49,000 (14.3) 44,000 (13.0) 48,000 (14.0) 42,000 (12.3) 48,000 (14.0) 41,000 (11.9) 44,000 (13.0) 43,000 (12.6) 47,000 (13.9) 43,000 (12.6) 47,000 (13.9) 75,000 (21.9) 82,000 (23.9) 54,000 (15.9) 60,000 (17.6) 15.0 (0.9) 16.5 (1.0) 10.1 (69.6) 12.1 (83.4) 55,000 (16.3) 60,000 (17.6) 47,000 (13.9) 53,000 (15.6) 11.0 (0.7) 12.2 (0.8) 5.6 (38.6) 6.8 (46.9) 52,000 (15.3) 58,000 (17.0) 49,000 (14.3) 55,000 (16.3) 10.6 (0.7) 11.8 (0.7) 5.2 (35.9) 6.4 (44.1) 46,000 (13.6) 51,000 (14.9) 43,000 (12.6) 48,000 (14.0) 9.2 (0.6) 10.3 (0.6) 4.0 (17.6) 4.9 (33.8) 44,000 (12.9) 49,000 (14.3) 43,000 (12.6) 49,000 (14.3) 8.9 (0.6) 9.9 (0.6) 3.7 (25.5) 4.6 (31.7) 41,000 (11.9) 44,000 (12.9) 39,000 (11.3) 43,000 (12.6) 8.2 (0.5) 8.9 (0.6) 3.2 (22.1) 3.7 (25.5) 39,000 (11.3) 44,000 (12.9) 39,000 (11.3) 44,000 (12.9) 7.9 (0.5) 8.9 (0.6) 3.0 (20.7) 3.7 (25.5) Performance Specifications—Glycol Cooled Performance Specifications—Glycol Cooled CM (kW-tons) 3kW (1 ton) 5kW (1.5ton) 7kW (2 ton) 10kW (3 ton) 14kW (4 ton) 17kW (5 ton) ECONOMIZER -- NET COOLING CAPACITY DATA -- BTU/HR (kW) 80F DB, 67F WB (26.7C DB, 19.4C WB) 50% RH Total 15,000 (4.3) 17,000 (4.9) 28,000 (8.3) 36,000 (10.3) 56,000 (16.6) 63,000 (18.3) Sensible 13,000 (3.9) 15,000 (4.3) 22,000 (6.6) 29,000 (8.6) 46,000 (13.6) 52,000 (15.3) 75F DB, 62.5F WB (23.9C DB, 16.9C WB) 50% RH Total 11,000 (3.3) 12,000 (3.6) 20,000 (6.0) 26,000 (7.6) 38,000 (10.9) 43,000 (12.6) Sensible 11,000 (3.3) 12,000 (3.6) 19,000 (5.6) 25,000 (7.3) 38,000 (10.9) 43,000 (12.6) 75F DB, 61F WB (23.9C DB, 16.1C WB) 45% RH Total 11,000 (3.3) 12,000 (3.6) 20,000 (6.0) 25,000 (7.3) 38,000 (10.9) 43,000 (12.6) Sensible 11,000 (3.3) 12,000 (3.6) 20,000 (6.0) 25,000 (7.3) 38,000 (10.9) 43,000 (12.6) 72F DB, 60F WB (22.2C DB, 15.5C WB) 50% RH Total 9,000 (2.6) 10,000 (2.9) 17,000 (4.9) 21,000 (6.3) 30,000 (8.9) 34,000 (9.9) Sensible 9,000 (2.6) 10,000 (2.9) 17,000 (4.9) 21,000 (6.3) 30,000 (8.9) 34,000 (9.9) 72F DB, 58.6 WB (22.2D DB, 14.8C WB) 45% RH Total 9,000 (2.6) 10,000 (2.9) 17,000 (4.9) 21,000 (6.3) 30,000 (8.9) 34,000 (9.9) Sensible 9,000 (2.6) 10,000 (2.9) 17,000 (4.9) 21,000 (6.3) 30,000 (8.9) 34,000 (9.9) 70F DB, 58.5F WB (21.1C DB, 14.8C WB) 50% RH Total 8,000 (2.3) 9,000 (2.6) 16,000 (4.6) 19,000 (5.6) 26,000 (7.6) 28,000 (8.3) Sensible 8,000 (2.3) 9,000 (2.6) 16,000 (4.6) 19,000 (5.6) 26,000 (7.6) 28,000 (8.3) 70F DB, 57.2F WB (21.1C DB, 14.0C WB) 45% RH Total 8,000 (2.3) 9,000 (2.6) 16,000 (4.6) 19,000 (5.6) 26,000 (7.6) 28,000 (8.3) Sensible 8,000 (2.3) 9,000 (2.6) 16,000 (4.6) 19,000 (5.6) 26,000 (7.6) 28,000 (8.3) COOLANT REQUIREMENTS THR -- MBH (kW) 21,000 (6.3) 25,000 (7.3) 33,000 (9.6) 48,000 (14.0) 68,000 (20.0) 78,000 (23.0) 105 F (40.6 C) Glycol In -- GPM (L/s) 2.7 (0.17) 3.8 (0.24) 5.7 (0.36) 7.2 (0.45) 10.8 (0.68) 14.0 (0.88) Pressure Drop w/HX -- psig (kPa) 3.2 (22.1) 3.9 (26.9) 4.9 (33.8) 8.3 (57.2) 8.0 (55.2) 9.1 (62.7) Internal Glycol Volume -- gal (L) 2 (7.6) 2 (7.6) 2 (7.6) 2 (7.6) 2 (7.6) 2 (7.6) Internal Glycol w/Economizer Volume -- gal (L) 4 (15.1) 4 (15.1) 4 (15.1) 4 (15.1) 4 (15.1) 4 (15.1) WATER REGULATING VALVES Size -- 2 Way Ball Valve -- Inches, NPT (Cv)* 1/2 (7) 1/2 (7) 1/2 (7) 3/4 (10) 1 (12) 1 (12) AIR SYSTEM -- BELT DRIVE CENTRIFUGAL Air Volume -- CFM (L/s) 625 (295) 700 (330) 900 (425) 1,200 (566) 2,000 (944) 2,300 (1,086) Blower Motor -- HP (kW) 0.25 (0.2) 0.25 (0.2) 0.25 (0.2) 0.50 (0.4) 1.50 (1.1) 1.50 (1.1) External Static Pressure -- inches of water (Pa) 0.3 (75) 0.3 (75) 0.3 (75) 0.3 (75) 0.5 (125) 0.5 (125) Number of Blowers 1 1 1 1 1 1 COMPRESSOR EER 7.3 11.6 11.9 12.5 12.6 12.7 Quantity 1 1 1 1 1 1 Nominal HP (kW) 1.0 (0.75) 1.5 (1.13) 2.0 (1.50) 3.0 (2.26) 4.0 (3.01) 5.0 (3.76) EVAPORATOR COIL -- SLAB 1.9 (0.17) 1.9 (0.17) 2.9 (0.27) 2.9 (0.27) 5.2 (0.48) 5.2 (0.48) Face Area -- ft2 (m2) Rows Deep 3 3 3 3 4 4 Face Velocity -- FPM (m/s) 338 (1.72) 378 (1.92) 310 (1.57) 414 (2.10) 385 (1.96) 442 (2.25) HUMIDIFICATION --- SOLID STATE ELECTRODE CANISTER Flush Cycle automatic automatic automatic automatic automatic automatic Capacity -- Lbs/hr (Kg/hr) 5 (2.3) 5 (2.3) 5 (2.3) 5 (2.3) 10 (4.5) 10 (4.5) kW 1.7 1.7 1.7 1.7 3.4 3.4 FILTERS Quantity 1 1 1 1 2 2 20 x 20 20 x 20 20 x 20 20 x 20 16 x 25 16 x 25 Size -- Inches (mm) (508 x 508) (508 x 508) (508 x 508) (508 x 508) (406 x 635) (406 x 635) Depth -- Inches (mm) 1 (25) 1 (25) 1 (25) 1 (25) 1 (25) 1 (25) REHEAT Electric -- Equally Loaded on each phase, rated at 230V/1 and 203/3 Capacity -BTU/HR (kW) Includes Motor Heat 10,000 (3.0) 10,000 (3.0) 19,000 (5.6) 20,000 (6.0) 39,000 (11.3) 39,000 (11.3) Stages 1 1 1 1 2 2 Hot Water -- 180F (82.2C) EWT, 140F (63.9C) LWT Capacity - BTU/HR (kW) Includes Motor Heat 23,000 (6.9) 26,000 (7.6) 31,000 (9.0) 39,000 (11.3) 50,000 (14.6) 55,000 (16.3) GPM (L/s) 1.0 (0.06) 1.5 (0.09) 2.0 (0.13) 3.0 (0.19) 3.0 (0.19) 3.5 (0.22) Pressure Drop -- PSI (kPA) 0.3 (2.1) 0.7 (4.8) 1.2 (8.3) 2.4 (16.6) 2.4 (16.6) 3.1 (21.4) Hot Gas Reheat Capacity -- BTU/HR (kW) Includes Motor Heat 13,000 (3.9) 14,000 (4.0) 16,000 (4.6) 20,000 (6.0) 26,000 (7.6) 27,000 (7.9) PHYSICAL DATA Weight -- lbs (kg) 280 (127) 280 (127) 355 (161) 380 (172) 585 (265) 585 (265) Height -- Inches (mm) 18.0 (465) 18.0 (465) 26.0 (673) 26.0 (673) 26.0 (673) 26.0 (673) Length -- Inches (mm) 49.0 (1245) 49.0 (1245) 51.0 (1295) 51.0 (1295) 60.0 (1524) 60.0 (1524) Depth -- Inches (mm) 26.0 (673) 26.0 (673) 26.0 (673) 26.0 (673) 38.0 (958) 38.0 (958) APC NetworkAIR™ CM 11 Performance Specifications—Glycol Cooled Performance Specifications—Glycol Cooled CM (kW-tons) CONNECTION SIZES** Glycol In/Out -- Inches OD Hot Water Supply Line -- Inches OD Return Line -- Inches OD Humidifier Supply Line -- Inches OD Condensate Drain Drain Line -- Inches ID MultiCool Supply Line -- Inches OD Return Line -- Inches OD *2-Way Single Seated, 400 psig W.W.P. max **Connection sizes, not recommended piping sizes 12 3kW (1 ton) 5kW (1.5ton) 7kW (2 ton) 10kW (3 ton) 14kW (4 ton) 17kW (5 ton) 5/8 5/8 3/4 7/8 1-3/8 1-3/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 1/4 1/4 1/4 1/4 1/4 1/4 7/8 7/8 7/8 7/8 7/8 7/8 1/2 1/2 1/2 1/2 7/8 7/8 7/8 7/8 1-3/8 1-3/8 1-3/8 1-3/8 APC NetworkAIR™ CM Performance Specifications—Chilled Water COOLING CAPACITY - BTU/HR (kW) 45F (7.2C) --- EWT 80F DB, 67F WB (26.7C DB, 19.4C WB) 50% RH Total - BTU/HR (kW) Sensible - BTU/HR (kW) Flow Rate - GPM (L/s) Pressure Drop - psig (kPa) 75F DB, 62.5F WB (23.9C DB, 16.9C WB) 50% RH Total - BTU/HR (kW) Sensible - BTU/HR (kW) Flow Rate - GPM (L/s) Pressure Drop - psig (kPa) 75F DB, 61F WB (23.9C DB, 16.1C WB) 45% RH Total - BTU/HR (kW) Sensible - BTU/HR (kW) Flow Rate - GPM (L/s) Pressure Drop - psig (kPa) 72F DB, 60F WB (22.2C DB, 15.5C WB) 50% RH Total - BTU/HR (kW) Sensible - BTU/HR (kW) Flow Rate - GPM (L/s) Pressure Drop - psig (kPa) 72F DB, 58.6 WB (22.2D DB, 14.8C WB) 45% RH Total - BTU/HR (kW) Sensible - BTU/HR (kW) Flow Rate - GPM (L/s) Pressure Drop - psig (kPa) 70F DB, 58.5F WB (21.1C DB, 14.8C WB) 50% RH Total - BTU/HR (kW) Sensible - BTU/HR (kW) Flow Rate - GPM (L/s) Pressure Drop - psig (kPa) 70F DB, 57.2F WB (21.1C DB, 14.0C WB) 45% RH Total - BTU/HR (kW) Sensible - BTU/HR (kW) Flow Rate - GPM (L/s) Pressure Drop - psig (kPa) WATER REGULATING VALVES Size -- 2 Way Ball Valve -- Inches, NPT (Cv)* AIR SYSTEM -- BELT DRIVE CENTRIFUGAL Air Volume -- CFM (L/s) Blower Motor -- HP (kW) External Static Pressure -- inches of water (Pa) Number of Blowers COOLING COIL -- SLAB 3kW (1 ton) 5kW (1.5ton) 7kW (2 ton) 10kW (3 ton) 14kW (4 ton) 17kW (5 ton) 20,000 (5.9) 15,000 (4.3) 4.1 (0.3) 5.6 (38.6) 22,000 (6.6) 17,000 (4.9) 4.4 (0.3) 6.5 (44.8) 37,000 (10.9) 46,000 (13.6) 75,000 (21.9) 82,000 (23.9) 26,000 (7.6) 33,000 (9.6) 54,000 (15.9) 60,000 (17.6) 10.7 (0.7) 9.4 (0.6) 15.0 (0.9) 16.5 (1.0) 7.5 (51.7) 8.6 (59.3) 10.1 (69.6) 12.1 (83.4) 15,000 (4.3) 14,000 (4.0) 3.0 (0.2) 3.1 (21.4) 16,000 (4.6) 15,000 (4.3) 3.3 (0.2) 3.7 (25.5) 27,000 (8.0) 23,000 (6.9) 5.5 (0.3) 4.2 (29.0) 34,000 (9.9) 29,000 (8.6) 6.9 (0.4) 4.8 (33.1) 55,000 (16.3) 60,000 (17.6) 47,000 (13.9) 53,000 (15.6) 11.0 (0.7) 12.2 (0.8) 5.6 (38.6) 6.8 (46.9) 14,000 (4.0) 14,000 (4.0) 2.9 (0.2) 3.0 (20.7) 16,000 (4.6) 16,000 (4.6) 3.2 (0.2) 3.6 (24.8) 26,000 (7.6) 24,000 (7.0) 5.2 (0.3) 3.7 (25.5) 33,000 (9.6) 31,000 (9.0) 6.6 (0.4) 4.4 (30.3) 52,000 (15.3) 58,000 (17.0) 49,000 (14.3) 55,000 (16.3) 10.6 (0.7) 11.8 (0.7) 5.2 (35.9) 6.4 (44.1) 13,000 (3.9) 13,000 (3.9) 2.5 (0.2) 2.3 (15.9) 14,000 (4.0) 13,000 (3.9) 2.8 (0.2) 2.7 (18.6) 23,000 (6.9) 21,000 (6.3) 4.6 (0.3) 3.0 (20.7) 29,000 (8.6) 27,000 (7.9) 5.8 (0.4) 3.6 (24.8) 46,000 (13.6) 51,000 (14.9) 43,000 (12.6) 48,000 (14.0) 9.2 (0.6) 10.3 (0.6) 4.0 (17.6) 4.9 (33.8) 13,000 (3.9) 13,000 (3.9) 2.5 (0.2) 2.3 (15.9) 14,000 (4.0) 14,000 (4.0) 2.8 (0.2) 2.7 (18.6) 22,000 (6.6) 21,000 (6.3) 4.4 (0.3) 2.7 (18.6) 28,000 (8.3) 27,000 (7.9) 5.6 (0.4) 3.3 (22.8) 44,000 (12.9) 49,000 (14.3) 43,000 (12.6) 49,000 (14.3) 8.9 (0.6) 9.9 (0.6) 3.7 (25.5) 4.6 (31.7) 11,000 (3.3) 11,000 (3.3) 2.3 (0.1) 1.9 (13.1) 12,000 (3.6) 12,000 (3.6) 2.5 (0.2) 2.2 (15.2) 20,000 (6.0) 19,000 (5.6) 4.1 (0.3) 2.4 (16.5) 26,000 (7.6) 25,000 (7.3) 5.2 (0.3) 2.9 (20.0) 41,000 (11.9) 44,000 (12.9) 39,000 (11.3) 43,000 (12.6) 8.2 (0.5) 8.9 (0.6) 3.2 (22.1) 3.7 (25.5) 12,000 (3.6) 12,000 (3.6) 2.3 (0.1) 1.9 (13.1) 12,000 (3.6) 12,000 (3.6) 2.5 (0.2) 2.2 (15.2) 20,000 (6.0) 20,000 (6.0) 4.0 (0.3) 2.3 (15.9) 25,000 (7.3) 25,000 (7.3) 5.1 (0.3) 2.7 (18.6) 39,000 (11.3) 44,000 (12.9) 39,000 (11.3) 44,000 (12.9) 7.9 (0.5) 8.9 (0.6) 3.0 (20.7) 3.7 (25.5) 1/2 (7) 1/2 (7) 1/2 (7) 3/4 (10) 1 (12) 1 (12) 625 (295) 0.25 (0.2) 0.3 (75) 1 700 (330) 0.25 (0.2) 0.3 (75) 1 900 (425) 0.25 (0.2) 0.3 (75) 1 1,200 (566) 0.50 (0.4) 0.3 (75) 1 2,000 (944) 1.50 (1.1) 0.5 (125) 1 2,300 (1,086) 1.50 (1.1) 0.5 (125) 1 1.9 (0.17) 3 378 (1.92) 2.9 (0.27) 3 310 (1.57) 2.9 (0.27) 3 414 (2.10) 5.2 (0.48) 4 385 (1.96) 5.2 (0.48) 4 442 (2.25) automatic 5 (2.3) 1.7 automatic 5 (2.3) 1.7 automatic 5 (2.3) 1.7 automatic 10 (4.5) 3.4 automatic 10 (4.5) 3.4 10,000 (3.0) 1 19,000 (5.6) 1 20,000 (6.0) 1 26,000 (7.6) 1.5 (0.09) 0.7 (4.8) 31,000 (9.0) 2.0 (0.13) 1.2 (8.3) 39,000 (11.3) 50,000 (14.6) 55,000 (16.3) 3.0 (0.19) 3.0 (0.19) 3.5 (0.22) 2.4 (16.6) 2.4 (16.6) 3.1 (21.4) 1 20 x 20 (508 x 508) 1 (25) 1 20 x 20 (508 x 508) 1 (25) 1.9 (0.17) Face Area -- ft2 (m2) Rows Deep 3 Face Velocity -- FPM (m/s) 338 (1.72) HUMIDIFICATION --- SOLID STATE ELECTRODE CANISTER Flush Cycle automatic Capacity -- Lbs/hr (Kg/hr) 5 (2.3) kW 1.7 REHEAT Electric -- Equally Loaded on each phase, rated at 230V/1 and 203/3 Capacity -BTU/HR (kW) Includes Motor Heat 10,000 (3.0) Stages 1 Hot Water -- 180F (82.2C) EWT, 140F (63.9C) LWT Capacity - BTU/HR (kW) Includes Motor Heat 23,000 (6.9) GPM (L/s) 1.0 (0.06) Pressure Drop -- PSI (kPA) 0.3 (2.1) FILTERS Quantity 1 20 x 20 Size -- Inches (mm) (508 x 508) Depth -- Inches (mm) 1 (25) APC NetworkAIR™ CM 1 20 x 20 (508 x 508) 1 (25) 39,000 (11.3) 39,000 (11.3) 2 2 2 16 x 25 (406 x 635) 1 (25) 2 16 x 25 (406 x 635) 1 (25) 13 Performance Specifications—Chilled Water Performance Specifications - Chilled Water CM (kW-tons) PHYSICAL DATA Weight -- lbs (kg) Height -- Inches (mm) Length -- Inches (mm) Depth -- Inches (mm) CONNECTION SIZES** Water In/Out -- Inches OD Hot Water Supply Line -- Inches OD Return Line -- Inches OD Humidifier Supply Line -- Inches OD Condensate Drain Return Line -- Inches ID *2-Way Single Seated, 400 psig W.W.P. max **Connection sizes, not recommended piping sizes 14 3kW (1 ton) 5kW (1.5ton) 7kW (2 ton) 10kW (3 ton) 14kW (4 ton) 17kW (5 ton) 280 (127) 18.0 (465) 49.0 (1245) 26.0 (673) 280 (127) 18.0 (465) 49.0 (1245) 26.0 (673) 355 (161) 26.0 (673) 51.0 (1295) 26.0 (673) 380 (172) 26.0 (673) 51.0 (1295) 26.0 (673) 585 (265) 26.0 (673) 60.0 (1524) 38.0 (958) 585 (265) 26.0 (673) 60.0 (1524) 38.0 (958) 1/2 1/2 7/8 7/8 7/8 7/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 1/4 1/4 1/4 1/4 1/4 1/4 7/8 7/8 7/8 7/8 7/8 7/8 APC NetworkAIR™ CM Electrical Data AIR COOLED - SELF CONTAINED REHEAT Electric HUMID Electrode Canister - Steam VOLTAGE 208 230 277 208 230 480 PHASE 1 1 1 3 3 3 3 kW (1 ton) FLA 24.1 25.1 22.7 N/A N/A N/A WSA 27.0 28.0 25.1 N/A N/A N/A MOP 30.0 35.0 30.0 N/A N/A N/A 5 kW (1.5 ton) FLA 24.0 25.0 22.6 N/A N/A N/A WSA 29.4 30.4 27.1 N/A N/A N/A MOP 35.0 35.0 35.0 N/A N/A N/A 7 kW (2 ton) FLA 35.3 37.4 29.7 24.4 25.6 11.5 WSA 41.7 43.8 35.0 28.7 29.9 13.6 MOP 50.0 50.0 40.0 35.0 35.0 15.0 10 kW (3 ton) FLA 43.4 45.5 35.9 30.5 25.9 13.2 WSA 52.6 54.7 43.5 35.9 37.1 15.8 MOP 70.0 70.0 50.0 45.0 45.0 20.0 14 kW (4 ton) FLA N/A N/A N/A 50.0 52.0 25.3 WSA N/A N/A N/A 64.8 67.5 31.7 MOP N/A N/A N/A 70.0 70.0 35.0 17 kW (5 ton) FLA N/A N/A N/A 51.2 53.2 25.3 WSA N/A N/A N/A 68.4 71.1 34.4 MOP N/A N/A N/A 80.0 80.0 40.0 AIR COOLED REHEAT Electric HUMID Electrode Canister - Steam VOLTAGE 208 230 277 208 230 480 PHASE 1 1 1 3 3 3 3 kW (1 ton) FLA 21.0 22.0 20.1 N/A N/A N/A WSA 23.9 25.0 22.2 N/A N/A N/A MOP 30.0 30.0 25.0 N/A N/A N/A 5 kW (1.5 ton) FLA 20.9 21.9 14.5 N/A N/A N/A WSA 26.3 27.3 19.0 N/A N/A N/A MOP 35.0 35.0 25.0 N/A N/A N/A 7 kW (2 ton) FLA 31.0 33.1 26.1 20.1 21.3 9.4 WSA 37.4 39.5 31.4 24.4 25.6 11.5 MOP 45.0 50.0 40.0 30.0 30.0 15.0 10 kW (3 ton) FLA 38.4 40.5 31.5 25.5 20.9 11.1 WSA 47.6 49.7 39.1 30.9 32.1 13.7 MOP 60.0 60.0 50.0 40.0 40.0 15.0 14 kW (4 ton) FLA N/A N/A N/A 43.2 45.6 22.1 WSA N/A N/A N/A 51.7 54.1 25.4 MOP N/A N/A N/A 60.0 60.0 30.0 17 kW (5 ton) FLA N/A N/A N/A 44.4 46.8 22.1 WSA N/A N/A N/A 61.6 64.7 31.2 MOP N/A N/A N/A 70.0 70.0 35.0 Steam, Hot Water or None Electric Steam, Hot Water or None Electrode Canister - Steam Steam or None Steam or None 208 230 277 208 230 480 208 230 277 208 230 480 208 230 277 208 230 480 1 1 1 3 3 3 1 1 1 3 3 3 1 1 1 3 3 3 20.6 19.7 17.2 N/A N/A N/A 24.1 25.1 22.7 N/A N/A N/A 12.4 12.3 11.1 N/A N/A N/A 23.5 22.6 25.1 N/A N/A N/A 27.0 28.0 25.1 N/A N/A N/A 15.3 15.2 13.5 N/A N/A N/A 30.0 30.0 25.0 N/A N/A N/A 30.0 35.0 30.0 N/A N/A N/A 20.0 20.0 15.0 N/A N/A N/A 20.5 19.6 17.1 N/A N/A N/A 24.0 25.0 22.6 N/A N/A N/A 12.3 12.2 11.0 N/A N/A N/A 22.8 21.9 19.0 N/A N/A N/A 29.4 30.4 27.1 N/A N/A N/A 14.6 14.5 12.9 N/A N/A N/A 35.0 30.0 25.0 N/A N/A N/A 35.0 35.0 35.0 N/A N/A N/A 25.0 25.0 20.0 N/A N/A N/A 23.0 22.1 19.2 20.7 19.8 9.8 35.3 37.4 29.7 24.4 25.6 11.5 14.8 14.7 13.1 12.5 12.4 6.1 29.4 28.5 24.6 25.0 23.4 11.9 41.7 43.8 35.0 28.7 29.9 13.6 21.2 21.1 18.4 16.8 16.7 8.2 40.0 35.0 30.0 30.0 30.0 15.0 50.0 50.0 40.0 35.0 35.0 15.0 30.0 30.0 25.0 20.0 20.0 15.0 31.1 30.2 25.4 26.8 25.9 11.5 43.4 45.5 35.9 30.5 25.9 13.2 22.9 22.8 19.3 18.6 18.5 7.8 40.3 39.4 33.0 32.2 31.3 14.1 52.6 54.7 43.5 35.9 37.1 15.8 32.1 32.0 26.9 24.0 23.9 10.4 50.0 50.0 45.0 40.0 40.0 15.0 70.0 70.0 50.0 45.0 45.0 20.0 45.0 45.0 40.0 35.0 35.0 15.0 N/A N/A N/A 34.2 32.7 17.0 N/A N/A N/A 50.0 52.0 25.3 N/A N/A N/A 24.8 24.2 12.7 N/A N/A N/A 45.1 43.3 21.4 N/A N/A N/A 64.8 67.5 31.7 N/A N/A N/A 33.3 32.7 16.0 N/A N/A N/A 50.0 50.0 25.0 N/A N/A N/A 70.0 70.0 35.0 N/A N/A N/A 45.0 45.0 20.0 N/A N/A N/A 35.4 33.9 17.0 N/A N/A N/A 51.2 53.2 25.3 N/A N/A N/A 26.0 25.4 12.7 N/A N/A N/A 48.7 47.0 24.0 N/A N/A N/A 68.4 71.1 34.4 N/A N/A N/A 36.9 36.3 18.6 N/A N/A N/A 60.0 60.0 30.0 N/A N/A N/A 80.0 80.0 40.0 N/A N/A N/A 50.0 50.0 25.0 Steam, Hot Water or None Electric Steam, Hot Water or None Electrode Canister - Steam Steam or None Steam or None 208 230 277 208 230 480 208 230 277 208 230 480 208 230 277 208 230 480 1 1 1 3 3 3 1 1 1 3 3 3 1 1 1 3 3 3 17.5 16.6 14.6 N/A N/A N/A 21.0 22.0 20.1 N/A N/A N/A 9.3 9.2 8.5 N/A N/A N/A 20.4 19.6 17.0 N/A N/A N/A 23.9 25.0 22.2 N/A N/A N/A 12.2 12.2 10.9 N/A N/A N/A 25.0 25.0 20.0 N/A N/A N/A 30.0 30.0 25.0 N/A N/A N/A 15.0 15.0 15.0 N/A N/A N/A 17.4 16.5 14.5 N/A N/A N/A 20.9 21.9 14.5 N/A N/A N/A 9.2 9.1 8.4 N/A N/A N/A 22.8 21.9 19.0 N/A N/A N/A 26.3 27.3 19.0 N/A N/A N/A 14.6 14.5 12.9 N/A N/A N/A 30.0 30.0 25.0 N/A N/A N/A 35.0 35.0 25.0 N/A N/A N/A 20.0 20.0 20.0 N/A N/A N/A 18.7 17.8 15.6 16.4 15.5 7.7 31.0 33.1 26.1 20.1 21.3 9.4 10.5 10.4 9.5 8.2 8.1 4.0 25.1 24.2 20.9 20.7 19.8 9.8 37.4 39.5 31.4 24.4 25.6 11.5 16.9 16.8 14.8 12.5 12.4 6.1 35.0 35.0 30.0 25.0 25.0 15.0 45.0 50.0 40.0 30.0 30.0 15.0 25.0 25.0 20.0 20.0 20.0 15.0 26.1 25.2 21.0 21.8 20.9 9.4 38.4 40.5 31.5 25.5 20.9 11.1 17.9 17.8 14.9 13.6 13.5 5.7 35.3 34.4 28.6 27.2 26.3 12.0 47.6 49.7 39.1 30.9 32.1 13.7 27.1 27.0 22.5 19.0 18.9 8.3 50.0 50.0 45.0 40.0 40.0 15.0 60.0 60.0 50.0 40.0 40.0 15.0 45.0 45.0 40.0 35.0 35.0 15.0 N/A N/A N/A 17.4 26.3 13.8 N/A N/A N/A 43.2 45.6 22.1 N/A N/A N/A 18.0 17.8 9.5 N/A N/A N/A 35.9 34.8 17.1 N/A N/A N/A 51.7 54.1 25.4 N/A N/A N/A 26.5 26.3 13.8 N/A N/A N/A 50.0 45.0 20.0 N/A N/A N/A 60.0 60.0 30.0 N/A N/A N/A 40.0 40.0 20.0 N/A N/A N/A 28.6 27.5 13.8 N/A N/A N/A 44.4 46.8 22.1 N/A N/A N/A 19.2 19.0 9.5 N/A N/A N/A 41.9 40.6 20.8 N/A N/A N/A 61.6 64.7 31.2 N/A N/A N/A 30.1 29.9 15.4 N/A N/A N/A 50.0 50.0 25.0 N/A N/A N/A 70.0 70.0 35.0 N/A N/A N/A 45.0 45.0 20.0 APC NetworkAIR™ CM 15 Electrical Data AIR COOLED - REMOTE CONDENSING REHEAT Electric HUMID Electrode Canister - Steam VOLTAGE 208 230 277 208 230 480 PHASE 1 1 1 3 3 3 3 kW (1 ton) FLA 22.5 22.7 20.6 N/A N/A N/A WSA 28.1 28.4 25.8 N/A N/A N/A MOP 30.0 30.0 30.0 N/A N/A N/A 5 kW (1.5 ton) FLA 22.5 22.7 20.6 N/A N/A N/A WSA 28.1 28.4 25.8 N/A N/A N/A MOP 30.0 30.0 30.0 N/A N/A N/A 7 kW (2 ton) FLA 31.3 32.6 25.6 22.7 23.1 10.4 WSA 39.1 40.8 32.0 28.4 28.9 13.0 MOP 40.0 45.0 35.0 30.0 30.0 15.0 10 kW (3 ton) FLA 33.4 34.7 26.6 24.8 25.2 10.4 WSA 41.8 43.4 33.3 31.0 31.5 13.0 MOP 45.0 45.0 35.0 35.0 35.0 15.0 14 kW (4 ton) FLA N/A N/A N/A 40.6 42.1 19.8 WSA N/A N/A N/A 50.5 52.3 24.6 MOP N/A N/A N/A 60.0 60.0 25.0 17 kW (5 ton) FLA N/A N/A N/A 40.6 42.1 19.8 WSA N/A N/A N/A 50.5 52.3 24.6 MOP N/A N/A N/A 60.0 60.0 25.0 Steam, Hot Water or None Electric Steam, Hot Water or None Electrode Canister - Steam Steam or None Steam or None 208 230 277 208 230 480 208 230 277 208 230 480 208 230 277 208 230 480 1 1 1 3 3 3 1 1 1 3 3 3 1 1 1 3 3 3 10.8 9.9 9.0 N/A N/A N/A 14.3 15.3 14.5 N/A N/A N/A 2.6 2.5 2.9 N/A N/A N/A 13.5 12.4 11.3 N/A N/A N/A 17.9 19.1 18.1 N/A N/A N/A 3.3 3.1 3.6 N/A N/A N/A 15.0 15.0 15.0 N/A N/A N/A 20.0 20.0 20.0 N/A N/A N/A 15.0 15.0 15.0 N/A N/A N/A 10.8 9.9 9.0 N/A N/A N/A 14.3 15.3 14.5 N/A N/A N/A 2.6 2.5 2.9 N/A N/A N/A 13.5 12.4 11.3 N/A N/A N/A 17.9 19.1 18.1 N/A N/A N/A 3.3 3.1 3.6 N/A N/A N/A 15.0 15.0 15.0 N/A N/A N/A 20.0 20.0 20.0 N/A N/A N/A 15.0 15.0 15.0 N/A N/A N/A 10.8 9.9 9.0 10.8 9.9 5.0 23.1 25.2 19.5 14.5 15.7 6.7 2.6 2.5 2.9 2.6 2.5 1.3 13.5 12.4 11.3 13.5 12.4 6.3 28.9 31.5 24.4 18.1 19.6 8.4 3.3 3.1 3.6 3.2 3.1 1.6 15.0 15.0 15.0 15.0 15.0 15.0 30.0 35.0 25.0 20.0 20.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 12.9 12.0 10.0 12.9 12.0 5.0 25.2 27.3 20.5 16.6 17.8 6.7 4.7 4.6 3.9 4.7 4.6 1.3 16.1 15.0 12.5 16.1 15.0 6.3 31.5 34.1 25.6 20.8 22.3 8.4 5.9 5.8 4.9 5.9 5.8 1.6 20.0 15.0 15.0 20.0 15.0 15.0 35.0 35.0 30.0 25.0 25.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 N/A N/A N/A 15.4 14.3 7.2 N/A N/A N/A 31.2 33.6 15.5 N/A N/A N/A 6.0 5.8 2.9 N/A N/A N/A 19.0 17.7 8.9 N/A N/A N/A 38.7 41.8 19.3 N/A N/A N/A 7.2 7.1 3.5 N/A N/A N/A 20.0 20.0 15.0 N/A N/A N/A 40.0 45.0 20.0 N/A N/A N/A 15.0 15.0 15.0 N/A N/A N/A 15.4 14.3 7.2 N/A N/A N/A 31.2 33.6 15.5 N/A N/A N/A 6.0 5.8 2.9 N/A N/A N/A 19.0 17.7 8.9 N/A N/A N/A 38.7 41.8 19.3 N/A N/A N/A 7.2 7.1 3.5 N/A N/A N/A 20.0 20.0 15.0 N/A N/A N/A 40.0 45.0 20.0 N/A N/A N/A 15.0 15.0 15.0 WATER COOLED - SELF CONTAINED REHEAT Electric HUMID Electrode Canister - Steam VOLTAGE 208 230 277 208 230 480 PHASE 1 1 1 3 3 3 3 kW (1 ton) FLA 20.5 21.5 13.8 N/A N/A N/A WSA 23.9 25.0 22.2 N/A N/A N/A MOP 30.0 30.0 25.0 N/A N/A N/A 5 kW (1.5 ton) FLA 20.3 21.3 19.5 N/A N/A N/A WSA 26.3 27.3 24.5 N/A N/A N/A MOP 35.0 35.0 30.0 N/A N/A N/A 7 kW (2 ton) FLA 29.8 31.9 25.1 19.5 20.7 9.1 WSA 37.4 39.5 31.4 24.4 25.6 11.5 MOP 45.0 50.0 40.0 30.0 30.0 15.0 10 kW (3 ton) FLA 36.3 23.1 29.7 25.5 29.9 10.6 WSA 47.6 49.7 39.1 30.9 32.1 13.7 MOP 60.0 60.0 50.0 40.0 40.0 15.0 14 kW (4 ton) FLA N/A N/A N/A 41.7 44.1 21.3 WSA N/A N/A N/A 51.7 54.1 25.4 MOP N/A N/A N/A 60.0 60.0 30.0 17 kW (5 ton) FLA N/A N/A N/A 42.7 45.1 21.3 WSA N/A N/A N/A 61.6 64.7 31.2 MOP N/A N/A N/A 70.0 70.0 35.0 16 Steam, Hot Water or None Electric Steam, Hot Water or None Electrode Canister - Steam Steam or None Steam or None 208 230 277 208 230 480 208 230 277 208 230 480 208 230 277 208 230 480 1 1 1 3 3 3 1 1 1 3 3 3 1 1 1 3 3 3 17.0 16.1 14.6 N/A N/A N/A 20.5 21.5 13.8 N/A N/A N/A 8.8 8.7 8.0 N/A N/A N/A 20.4 19.6 17.0 N/A N/A N/A 23.9 25.0 22.2 N/A N/A N/A 12.2 12.2 10.9 N/A N/A N/A 25.0 25.0 20.0 N/A N/A N/A 30.0 30.0 25.0 N/A N/A N/A 15.0 15.0 15.0 N/A N/A N/A 16.8 15.9 14.0 N/A N/A N/A 20.3 21.3 19.5 N/A N/A N/A 8.6 8.5 7.9 N/A N/A N/A 22.8 21.9 19.0 N/A N/A N/A 26.3 27.3 24.5 N/A N/A N/A 14.6 14.5 12.9 N/A N/A N/A 30.0 30.0 25.0 N/A N/A N/A 35.0 35.0 30.0 N/A N/A N/A 20.0 20.0 20.0 N/A N/A N/A 21.0 16.6 14.6 15.8 14.9 7.4 29.8 31.9 25.1 19.5 20.7 9.1 9.3 9.2 8.5 7.6 7.5 3.7 25.1 24.2 20.9 20.7 19.8 9.8 37.4 39.5 31.4 24.4 25.6 11.5 16.9 16.8 14.8 12.5 12.4 6.1 35.0 35.0 30.0 25.0 25.0 15.0 45.0 50.0 40.0 30.0 30.0 15.0 25.0 25.0 20.0 20.0 20.0 15.0 24.0 23.1 19.2 20.8 19.9 8.9 36.3 23.1 29.7 25.5 29.9 10.6 15.8 15.7 13.1 12.6 12.5 5.2 35.3 34.4 28.6 27.2 26.3 12.0 47.6 49.7 39.1 30.9 32.1 13.7 27.1 27.0 22.5 19.0 18.9 8.3 50.0 50.0 45.0 40.0 40.0 15.0 60.0 60.0 50.0 40.0 40.0 15.0 45.0 45.0 40.0 35.0 35.0 15.0 N/A N/A N/A 25.9 24.8 13.0 N/A N/A N/A 41.7 44.1 21.3 N/A N/A N/A 16.5 16.3 8.7 N/A N/A N/A 35.9 34.8 17.1 N/A N/A N/A 51.7 54.1 25.4 N/A N/A N/A 26.5 26.3 13.8 N/A N/A N/A 50.0 45.0 20.0 N/A N/A N/A 60.0 60.0 30.0 N/A N/A N/A 40.0 40.0 20.0 N/A N/A N/A 26.9 25.8 13.0 N/A N/A N/A 42.7 45.1 21.3 N/A N/A N/A 17.9 17.3 8.7 N/A N/A N/A 41.9 40.6 20.8 N/A N/A N/A 61.6 64.7 31.2 N/A N/A N/A 30.1 29.9 15.4 N/A N/A N/A 50.0 50.0 25.0 N/A N/A N/A 70.0 70.0 35.0 N/A N/A N/A 45.0 45.0 20.0 APC NetworkAIR™ CM Electrical Data GLYCOL COOLED - SELF CONTAINED REHEAT Electric HUMID Electrode Canister - Steam VOLTAGE 208 230 277 208 230 480 PHASE 1 1 1 3 3 3 3 kW (1 ton) FLA 21.2 22.2 20.2 N/A N/A N/A WSA 23.9 25.0 22.2 N/A N/A N/A MOP 30.0 30.0 25.0 N/A N/A N/A 5 kW (1.5 ton) FLA 21.1 22.1 19.5 N/A N/A N/A WSA 26.3 27.3 24.5 N/A N/A N/A MOP 35.0 35.0 30.0 N/A N/A N/A 7 kW (2 ton) FLA 31.5 33.6 26.5 20.4 21.6 9.6 WSA 37.4 39.5 31.4 24.4 25.6 11.5 MOP 45.0 50.0 40.0 30.0 30.0 15.0 10 kW (3 ton) FLA 40.5 42.6 32.1 25.9 21.3 11.3 WSA 47.6 49.7 39.1 30.9 32.1 13.7 MOP 60.0 60.0 50.0 40.0 40.0 15.0 14 kW (4 ton) FLA N/A N/A N/A 45.2 47.6 22.1 WSA N/A N/A N/A 51.7 54.1 25.4 MOP N/A N/A N/A 60.0 60.0 30.0 17 kW (5 ton) FLA N/A N/A N/A 45.0 47.4 22.4 WSA N/A N/A N/A 61.6 64.7 31.2 MOP N/A N/A N/A 70.0 70.0 35.0 CHILLED WATER REHEAT Electric HUMID Electrode Canister - Steam VOLTAGE 208 230 277 208 230 480 PHASE 1 1 1 3 3 3 3 kW (1 ton) FLA 22.5 22.7 20.6 N/A N/A N/A WSA 28.1 28.4 25.8 N/A N/A N/A MOP 30.0 30.0 30.0 N/A N/A N/A 5 kW (1.5 ton) FLA 22.5 22.7 20.6 N/A N/A N/A WSA 28.1 28.4 25.8 N/A N/A N/A MOP 30.0 30.0 30.0 N/A N/A N/A 7 kW (2 ton) FLA 31.3 32.6 25.6 22.7 23.1 10.4 WSA 39.1 40.8 32.0 28.4 28.9 13.0 MOP 40.0 45.0 35.0 30.0 30.0 15.0 10 kW (3 ton) FLA 33.4 34.7 26.6 24.8 25.2 10.4 WSA 41.8 43.4 33.3 31.0 31.5 13.0 MOP 45.0 45.0 35.0 35.0 35.0 15.0 14 kW (4 ton) FLA N/A N/A N/A 40.6 42.1 19.8 WSA N/A N/A N/A 50.5 52.3 24.6 MOP N/A N/A N/A 60.0 60.0 25.0 17 kW (5 ton) FLA N/A N/A N/A 40.6 42.1 19.8 WSA N/A N/A N/A 50.5 52.3 24.6 MOP N/A N/A N/A 60.0 60.0 25.0 Steam, Hot Water or None Electric Steam, Hot Water or None Electrode Canister - Steam Steam or None Steam or None 208 230 277 208 230 480 208 230 277 208 230 480 208 230 277 208 230 480 1 1 1 3 3 3 1 1 1 3 3 3 1 1 1 3 3 3 17.7 16.8 14.7 N/A N/A N/A 21.2 22.2 20.2 N/A N/A N/A 9.5 9.4 8.6 N/A N/A N/A 20.4 19.6 17.0 N/A N/A N/A 23.9 25.0 22.2 N/A N/A N/A 12.2 12.2 10.9 N/A N/A N/A 25.0 25.0 20.0 N/A N/A N/A 30.0 30.0 25.0 N/A N/A N/A 15.0 15.0 15.0 N/A N/A N/A 17.6 16.7 14.6 N/A N/A N/A 21.1 22.1 19.5 N/A N/A N/A 9.4 9.3 7.9 N/A N/A N/A 22.8 21.9 19.0 N/A N/A N/A 26.3 27.3 24.5 N/A N/A N/A 14.6 14.5 12.9 N/A N/A N/A 30.0 30.0 25.0 N/A N/A N/A 35.0 35.0 30.0 N/A N/A N/A 20.0 20.0 20.0 N/A N/A N/A 19.2 18.3 16.0 16.7 15.8 7.9 31.5 33.6 26.5 20.4 21.6 9.6 11.0 10.9 9.9 8.5 8.4 3.8 25.1 24.2 20.9 20.7 19.8 9.8 37.4 39.5 31.4 24.4 25.6 11.5 16.9 16.8 14.8 12.5 12.4 6.1 35.0 35.0 30.0 25.0 25.0 15.0 45.0 50.0 40.0 30.0 30.0 15.0 25.0 25.0 20.0 20.0 20.0 15.0 26.9 26.0 21.6 22.4 21.3 9.6 40.5 42.6 32.1 25.9 21.3 11.3 18.7 18.6 15.5 14.0 13.9 5.9 35.3 34.4 28.6 27.2 26.3 12.0 47.6 49.7 39.1 30.9 32.1 13.7 27.1 27.0 22.5 19.0 18.9 8.3 50.0 50.0 45.0 40.0 40.0 15.0 60.0 60.0 50.0 40.0 40.0 15.0 45.0 45.0 40.0 35.0 35.0 15.0 N/A N/A N/A 27.9 26.8 13.8 N/A N/A N/A 45.2 47.6 22.1 N/A N/A N/A 18.5 18.3 9.8 N/A N/A N/A 35.9 34.8 17.1 N/A N/A N/A 51.7 54.1 25.4 N/A N/A N/A 26.5 26.3 13.8 N/A N/A N/A 50.0 45.0 20.0 N/A N/A N/A 60.0 60.0 30.0 N/A N/A N/A 40.0 40.0 20.0 N/A N/A N/A 29.2 28.1 14.1 N/A N/A N/A 45.0 47.4 22.4 N/A N/A N/A 19.8 19.6 9.8 N/A N/A N/A 41.9 40.6 20.8 N/A N/A N/A 61.6 64.7 31.2 N/A N/A N/A 30.1 29.9 15.4 N/A N/A N/A 50.0 50.0 25.0 N/A N/A N/A 70.0 70.0 35.0 N/A N/A N/A 45.0 45.0 20.0 Steam, Hot Water or None Electric Steam, Hot Water or None Electrode Canister - Steam Steam or None Steam or None 208 230 277 208 230 480 208 230 277 208 230 480 208 230 277 208 230 480 1 1 1 3 3 3 1 1 1 3 3 3 1 1 1 3 3 3 10.8 9.9 9.0 N/A N/A N/A 14.3 15.3 14.5 N/A N/A N/A 2.6 2.5 2.9 N/A N/A N/A 13.5 12.4 11.3 N/A N/A N/A 17.9 19.1 18.1 N/A N/A N/A 3.3 3.1 3.6 N/A N/A N/A 15.0 15.0 15.0 N/A N/A N/A 20.0 20.0 20.0 N/A N/A N/A 15.0 15.0 15.0 N/A N/A N/A 10.8 9.9 9.0 N/A N/A N/A 14.3 15.3 14.5 N/A N/A N/A 2.6 2.5 2.9 N/A N/A N/A 13.5 12.4 11.3 N/A N/A N/A 17.9 19.1 18.1 N/A N/A N/A 3.3 3.1 3.6 N/A N/A N/A 15.0 15.0 15.0 N/A N/A N/A 20.0 20.0 20.0 N/A N/A N/A 15.0 15.0 15.0 N/A N/A N/A 10.8 9.9 9.0 10.8 9.9 5.0 23.1 25.2 19.5 14.5 15.7 6.7 2.6 2.5 2.9 2.6 2.5 1.3 13.5 12.4 11.3 13.5 12.4 6.3 28.9 31.5 24.4 18.1 19.6 8.4 3.3 3.1 3.6 3.2 3.1 1.6 15.0 15.0 15.0 15.0 15.0 15.0 30.0 35.0 25.0 20.0 20.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 12.9 12.0 10.0 12.9 12.0 5.0 25.2 27.3 20.5 16.6 17.8 6.7 4.7 4.6 3.9 4.7 4.6 1.3 16.1 15.0 12.5 16.1 15.0 6.3 31.5 34.1 25.6 20.8 22.3 8.4 5.9 5.8 4.9 5.9 5.8 1.6 20.0 15.0 15.0 20.0 15.0 15.0 35.0 35.0 30.0 25.0 25.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 N/A N/A N/A 15.4 14.3 7.2 N/A N/A N/A 31.2 33.6 15.5 N/A N/A N/A 6.0 5.8 2.9 N/A N/A N/A 19.0 17.7 8.9 N/A N/A N/A 38.7 41.8 19.3 N/A N/A N/A 7.2 7.1 3.5 N/A N/A N/A 20.0 20.0 15.0 N/A N/A N/A 40.0 45.0 20.0 N/A N/A N/A 15.0 15.0 15.0 N/A N/A N/A 15.4 14.3 7.2 N/A N/A N/A 31.2 33.6 15.5 N/A N/A N/A 6.0 5.8 2.9 N/A N/A N/A 19.0 17.7 8.9 N/A N/A N/A 38.7 41.8 19.3 N/A N/A N/A 7.2 7.1 3.5 N/A N/A N/A 20.0 20.0 15.0 N/A N/A N/A 40.0 45.0 20.0 N/A N/A N/A 15.0 15.0 15.0 APC NetworkAIR™ CM 17 Dimensional Data Spot-cooled -- 3-5kW (1-1.5 ton) * All dimensions are in inches (mm). 18 APC NetworkAIR™ CM Dimensional Data Spot-cooled -- 7-10kW (2-3 ton) * All dimensions are in inches (mm). APC NetworkAIR™ CM 19 Dimensional Data Spot-cooled self contained -- 3-5kW (1-1.5 ton) * All dimensions are in inches (mm). 20 APC NetworkAIR™ CM Dimensional Data Spot-cooled self contained -- 7-10kW (2-3 ton) * All dimensions are in inches (mm). APC NetworkAIR™ CM 21 Dimensional Data Ducted -- 3-5kW (1-1.5 ton) * All dimensions are in inches (mm). 22 APC NetworkAIR™ CM Dimensional Data Ducted -- 7-10kW (2-3 ton) * All dimensions are in inches (mm). APC NetworkAIR™ CM 23 Dimensional Data Ducted -- 14-17kW (4-5 ton) * All dimensions are in inches (mm). 24 APC NetworkAIR™ CM Dimensional Data Ducted self contained -- 3-5kW (1-1.5 ton) * All dimensions are in inches (mm). APC NetworkAIR™ CM 25 Dimensional Data Ducted self contained -- 7-10kW (2-3 ton) * All dimensions are in inches (mm). 26 APC NetworkAIR™ CM Dimensional Data Ducted self contained -- 14-17kW (4-5 ton) * All dimensions are in inches (mm). APC NetworkAIR™ CM 27 Air-Cooled Condensers Air-cooled condenser—performance/electrical data OHE SKU Voltage Control Ambient Temperature Air Quantity 95F 105F 115F CFM L/s Fan/Motor Connection Qty. HP RP M Hot Gas Weight Liquid Lbs Kg Electrical Data FLA MCA MOP ACCD75000 208-230/1/60 FSC 3kW N/A N/A 2,400 1,132 1 1/4 1075 3/8” 3/8” 96 44 2.0 2.5 15.0 ACCD75001 FSC 3kW N/A N/A 2,400 1,132 1 1/4 1075 3/8” 3/8” 96 44 1.0 1.3 15.0 ACCD75002 208-230/1/60 FL 3kW N/A N/A 2,400 1,132 1 1/4 1075 3/8” 3/8” 96 44 2.0 2.5 15.0 ACCD75003 FL 3kW N/A N/A 2,400 1,132 1 1/4 1075 3/8” 3/8” 96 44 1.0 1.3 15.0 ACCD75008 208-230/1/60 FSC N/A 3kW N/A 2,400 1,132 1 1/4 1075 5/8” 5/8” 96 44 2.0 2.5 15.0 ACCD75009 FSC N/A 3kW N/A 2,400 1,132 1 1/4 1075 5/8” 5/8” 96 44 1.0 1.3 15.0 ACCD75004 208-230/1/60 FSC 5kW N/A N/A 2,400 1,132 1 1/4 1075 5/8” 5/8” 96 44 2.0 2.5 15.0 ACCD75005 480/1/60 480/1/60 480/1/60 FSC 5kW N/A N/A 2,400 1,132 1 1/4 1075 5/8” 5/8” 96 44 1.0 1.3 15.0 ACCD75006 208-230/1/60 FL 5kW N/A N/A 2,400 1,132 1 1/4 1075 5/8” 5/8” 96 44 2.0 2.5 15.0 ACCD75007 FL 5kW N/A N/A 2,400 1,132 1 1/4 1075 5/8” 5/8” 96 44 1.0 1.3 15.0 3kW 5kW 2,100 991 1 1/4 1075 7/8” 5/8” 114 52 2.0 2.5 15.0 480/1/60 480/1/60 ACCD75010 208-230/1/60 FSC 7kW 10kW 5kW ACCD75011 FSC 7kW 5kW 10kW 3kW 5kW 2,100 991 1 1/4 1075 7/8” 5/8” 114 52 1.0 1.3 15.0 ACCD75012 208-230/1/60 FL 7kW 10kW N/A N/A 2,100 991 1 1/4 1075 7/8” 5/8” 114 52 2.0 2.5 15.0 ACCD75013 FL 7kW N/A 10kW N/A 2,100 991 1 1/4 1075 7/8” 5/8” 114 52 1.0 1.3 15.0 480/1/60 480/1/60 ACCD75014 208-230/1/60 FSC 14kW 7kW 7kW 17kW 10kW 5,050 2,383 1 1/3 1075 1-1/8” 7/8” 180 82 3.4 4.3 15.0 ACCD75015 FSC 14kW 7kW 17kW 10kW 7kW 5,050 2,383 1 1/3 1075 1-1/8” 7/8” 180 82 1.7 2.1 15.0 480/1/60 ACCD75016 208-230/1/60 FL 14kW N/A 17kW N/A 5,050 2,383 1 1/3 1075 1-1/8” 7/8” 180 82 3.4 4.3 15.0 ACCD75017 FL 14kW N/A 17kW N/A 5,050 2,383 1 1/3 1075 1-1/8” 7/8” 180 82 1.7 2.1 15.0 480/1/60 ACCD75018 208-230/1/60 FSC 14kW N/A 17kW 10kW 6,450 3,044 1 1/2 1075 1-1/8” 7/8” 260 118 3.9 4.9 15.0 ACCD75019 FSC N/A 14kW 10kW 6,450 3,044 17kW 1 1/2 1075 1-1/8” 7/8” 260 118 2.0 2.4 15.0 ACCD75022 208-230/3/60 FSC N/A N/A 14kW 10,100 4,767 17kW 2 1/3 1140 1-1/8” 7/8” 450 204 6.8 7.7 15.0 ACCD75023 FSC N/A 14kW N/A 17kW 10,100 4,767 2 1/3 1140 1-1/8” 7/8” 450 204 3.4 3.8 15.0 480/1/60 480/3/60 FLA = Full Load Amps MCA = Minimum Circuit Amperes MOP = Maximum Overcurrent Protection *Single Fan Condenser with Fan Speed Control must be single phase. 28 APC NetworkAIR™ CM Air-Cooled Condensers 1-fan air-cooled condenser APC PART CIRCUIT CONTROL VOLTAGE ACCD75000 single Fan Speed 208-230/1/60 ACCD75001 single Fan Speed 480/1/60 ACCD75002 single Flooded 208-230/1/60 ACCD75003 single Flooded 480/1/60 ACCD75008 single Fan Speed 208-230/1/60 ACCD75009 single Fan Speed 480/1/60 ACCD75010 single Fan Speed 208-230/1/60 ACCD75011 single Fan Speed 480/1/60 ACCD75004 single Fan Speed 208-230/1/60 ACCD75005 single Fan Speed 480/1/60 ACCD75006 single Flooded 208-230/1/60 ACCD75007 single Flooded 480/1/60 ACCD75012 single Flooded 208-230/1/60 ACCD75013 single Flooded 480/1/60 1-fan air-cooled condenser APC PART CIRCUIT CONTROL VOLTAGE ACCD75014 single Fan Speed 208-230/1/60 ACCD75015 single Fan Speed 480/1/60 ACCD75016 single Fan Speed 208-230/1/60 ACCD75017 single Fan Speed 480/1/60 APC NetworkAIR™ CM 29 Air-Cooled Condensers 1-fan air-cooled condenser APC PART CIRCUIT CONTROL VOLTAGE ACCD75018 single Fan Speed 208-230/1/60 ACCD75019 single Fan Speed 480/1/60 2-fan air-cooled condenser 30 APC PART CIRCUIT CONTROL VOLTAGE ACCD75022 single Fan Speed 208-230/3/60 ACCD75023 single Fan Speed 480/3/60 APC NetworkAIR™ CM Fluid Coolers Glycol-cooled fluid cooler—performance/electrical data OHE SKU Voltage Ambient Temperature 40% Ethylene Glycol @ 130F Air Quantity Fan/Motor 95F 105F PD(ft) @GPM CFM L/s Qty HP RPM ACFC75106 208-230/1/60 3kW N/A 5.9@3 2,400 1,132 1 1/4 1075 ACFC75107 3kW N/A 5.9@3 2,400 1,132 1 1/4 1075 ACFC75108 208-230/1/60 5kW N/A 5.9@4 2,400 1,132 1 1/4 ACFC75109 5kW N/A 5.9@4 2,400 1,132 1 ACFC75110 208-230/1/60 7kW 3kW 5kW 3.5@6 2,100 991 ACFC75111 7kW 3kW 5kW 3.5@6 2,100 ACFC75112 208-230/3/60 10kW 480/1/60 480/1/60 480/1/60 Conne ct-ions Weight Glycol Volume Electrical Data Lbs Kg Gal L FLA MCA MOP 7/8” 96 44 1.1 4.2 2.0 2.5 15.0 7/8” 96 44 1.1 4.2 1.0 1.3 15.0 1075 7/8” 96 44 1.1 4.2 2.0 2.5 15.0 1/4 1075 7/8” 96 44 1.1 4.2 1.0 1.3 15.0 1 1/4 1075 1-1/8” 114 52 1.6 6.0 2.0 2.5 15.0 991 1 1/4 1075 1-1/8” 114 52 1.6 6.0 1.0 1.3 15.0 7kW 4.5@15 5,050 2,383 1 1/3 1140 1-3/8” 180 82 2.6 9.8 2.6 3.3 15.0 10kW 7kW 4.5@15 5,050 2,383 1 1/3 1140 1-3/8” 180 82 2.6 9.8 1.3 1.6 15.0 ACFC75114 208-230/3/60 14kW 10kW 5.6@20 6,450 3,044 1 1/3 1140 1-5/8” 260 118 3.8 14.4 2.6 3.3 15.0 14kW 10kW 5.6@20 6,450 3,044 1 1/3 1140 1-5/8” 260 118 3.8 14.4 1.3 1.6 15.0 ACFC75116 208-230/3/60 17kW 14kW 15.5@15 10,100 4,766 2 1/3 1140 1-3/8” 450 204 4.0 15.1 5.2 5.9 15.0 17kW 14kW 15.5@15 10,100 4,766 2 1/3 1140 1-3/8” 450 204 4.0 15.1 2.6 2.9 15.0 ACFC75113 ACFC75115 ACFC75117 480/3/60 480/3/60 480/3/60 ACFC75118 208-230/3/60 N/A 17kW 15.5@15 12,400 5,852 2 1/3 1140 1-3/8” 470 213 4.0 15.1 5.2 5.9 15.0 ACFC75119 N/A 17kW 15.5@15 12,400 5,852 2 1/3 1140 1-3/8” 470 213 4.0 15.1 2.6 2.9 15.0 480/3/60 FLA = Full Load Amps MCA = Minimum Circuit Amperes MOP = Maximum Overcurrent Protection *Fluid coolers can be selected for multiple indoor air conditioning units from the factory. Consult factory for help configuring many-to-one or one-to-many glycol loops. APC NetworkAIR™ CM 31 Fluid Coolers 1-fan fluid cooler APC PART VOLTAGE ACFC75106 208-230/1/60 ACFC75107 480/1/60 ACFC75110 208-230/1/60 ACFC75111 480/1/60 ACFC75108 208-230/1/60 ACFC75109 480/1/60 1-fan fluid cooler 32 APC PART VOLTAGE ACFC75112 208-230/3/60 ACFC75113 480/3/60 APC NetworkAIR™ CM Fluid Coolers 1-fan fluid cooler APC PART VOLTAGE ACFC75114 208-230/3/60 ACFC75115 480/3/60 2-fan fluid cooler APC PART VOLTAGE ACFC75116 208-230/3/60 ACFC75117 480/3/60 ACFC75118 208-230/3/60 ACFC75119 480/3/60 APC NetworkAIR™ CM 33 Remote Condensing Units Remote condensing unit—performance/electrical data Model OHE SKU Voltage Control 3kW (1 ton) ACCG75200 208-230/1/60 ACCG75201 5kW (1.5 ton) 7kW (2 ton) 10kW (3 ton) 14kW (4 ton) 17kW (5 ton) Fan/Motor HP -20 F 1 1/15 3/8” 208-230/3/60 -20 F 1 1/15 ACCG75202 480/3/60 -20 F 1 ACCG75226 208-230/1/60 -30 F ACCG75227 208-230/3/60 ACCG75228 Electrical Data Kg FLA 5/8” 172 78 6.8 15.0 15.0 3/8” 5/8” 172 78 4.7 15.0 15.0 1/15 3/8” 5/8” 172 78 2.6 15.0 15.0 1 1/15 3/8” 5/8” 172 78 6.8 20.0 20.0 -30 F 1 1/15 3/8” 5/8” 172 78 4.7 20.0 20.0 480/3/60 -30 F 1 1/15 3/8” 5/8” 172 78 2.6 20.0 20.0 ACCG75203 208-230/1/60 -20 F 2 1/15 3/8” 5/8” 223 101 9.1 15.0 15.0 ACCG75204 208-230/3/60 -20 F 2 1/15 3/8” 5/8” 223 101 5.9 15.0 15.0 ACCG75205 480/3/60 -20 F 2 1/15 3/8” 5/8” 223 101 3.8 15.0 15.0 ACCG75224 208-230/1/60 -30 F 2 1/15 3/8” 5/8” 223 101 9.1 24.0 25.0 ACCG75230 208-230/3/60 -30 F 2 1/15 3/8” 5/8” 223 101 5.9 24.0 20.0 ACCG75231 480/3/60 -30 F 2 1/15 3/8” 5/8” 223 101 3.8 20.0 20.0 ACCG75206 208-230/1/60 -20 F 2 1/15 3/8” 7/8” 225 102 13.2 20.0 25.0 ACCG75207 208-230/3/60 -20 F 2 1/15 3/8” 7/8” 225 102 7.7 15.0 15.0 ACCG75208 480/3/60 -20 F 2 1/15 3/8” 7/8” 225 102 4.6 15.0 15.0 ACCG75232 208-230/1/60 -30 F 2 1/15 3/8” 7/8” 225 102 13.2 29.0 30.0 ACCG75233 208-230/3/60 -30 F 2 1/15 3/8” 7/8” 225 102 7.7 24.0 25.0 ACCG75234 480/3/60 -30 F 2 1/15 3/8” 7/8” 225 102 4.6 20.0 20.0 ACCG75209 208-230/1/60 -20 F 1 1/3 1/2” 7/8” 311 141 20.2 24.3 40.0 ACCG75210 208-230/3/60 -20 F 1 1/3 1/2” 7/8” 311 141 13.4 20.0 25.0 ACCG75211 480/3/60 -20 F 1 1/3 1/2” 7/8” 311 141 6.9 15.0 15.0 ACCG75235 208-230/1/60 -30 F 1 1/3 1/2” 7/8” 311 141 20.2 38.0 50.0 ACCG75236 208-230/3/60 -30 F 1 1/3 1/2” 7/8” 311 141 13.4 38.0 40.0 ACCG75237 480/3/60 -30 F 1 1/3 1/2” 7/8” 311 141 6.9 24.0 25.0 ACCG75212 208-230/1/60 -20 F 1 1/3 1/2” 1-1/8” 319 145 29.5 36.0 50.0 ACCG75213 208-230/3/60 -20 F 1 1/3 1/2” 1-1/8” 319 145 19.8 23.9 40.0 ACCG75214 480/3/60 -20 F 1 1/3 1/2” 1-1/8” 319 145 10.0 15.0 15.0 ACCG75238 208-230/1/60 -30 F 1 1/3 1/2” 1-1/8” 319 145 29.5 48.0 60.0 ACCG75239 208-230/3/60 -30 F 1 1/3 1/2” 1-1/8” 319 145 19.8 38.0 50.0 ACCG75240 480/3/60 -30 F 1 1/3 1/2” 1-1/8” 319 145 10.0 29.0 30.0 ACCG75215 208-230/1/60 -20 F 1 1/3 1/2” 1-1/8” 333 151 34.3 42.0 50.0 ACCG75216 208-230/3/60 -20 F 1 1/3 1/2” 1-1/8” 333 151 22.7 28.0 45.0 ACCG75217 480/3/60 -20 F 1 1/3 1/2” 1-1/8” 333 151 10.6 15.0 20.0 ACCG75241 208-230/1/60 -30 F 1 1/3 1/2” 1-1/8” 333 151 34.3 59.0 60.0 ACCG75242 208-230/3/60 -30 F 1 1/3 1/2” 1-1/8” 333 151 22.7 40.0 50.0 ACCG75243 480/3/60 -30 F 1 1/3 1/2” 1-1/8” 333 151 10.6 29.0 30.0 APC NetworkAIR™ CM Liquid Suction Weight Lbs FLA = Full Load Amps MCA = Minimum Circuit Amperes MOP = Maximum Overcurrent Protection 34 Connection Qty MCA MOP Remote Condensing Units 1-fan remote outdoor condensing unit APC PART VOLTAGE CONTROL ACCG75200 208-230/1/60 -20 F Flooded ACCG75201 208-230/3/60 -20 F Flooded ACCG75202 480/3/60 -20 F Flooded ACCG75226 208-230/1/60 -30 F Flooded ACCG75227 208-230/3/60 -30 F Flooded ACCG75228 480/3/60 -30 F Flooded 2-fan remote outdoor condensing unit APC PART VOLTAGE CONTROL ACCG75203 208-230/1/60 -20 F Flooded ACCG75204 208-230/3/60 -20 F Flooded ACCG75205 480/3/60 -20 F Flooded ACCG75224 208-230/1/60 -30 F Flooded ACCG75230 208-230/3/60 -30 F Flooded ACCG75231 480/3/60 -30 F Flooded ACCG75206 208-230/1/60 -20 F Flooded ACCG75207 208-230/3/60 -20 F Flooded ACCG75208 480/3/60 -20 F Flooded ACCG75232 208-230/1/60 -30 F Flooded ACCG75233 208-230/3/60 -30 F Flooded ACCG75234 480/3/60 -30 F Flooded APC NetworkAIR™ CM 35 Remote Condensing Units 1-fan remote outdoor condensing unit 36 APC PART VOLTAGE CONTROL ACCG75209 208-230/1/60 -20 F Flooded ACCG75210 208-230/3/60 -20 F Flooded ACCG75211 480/3/60 -20 F Flooded ACCG75235 208-230/1/60 -30 F Flooded ACCG75236 208-230/3/60 -30 F Flooded ACCG75237 480/3/60 -30 F Flooded ACCG75212 208-230/1/60 -20 F Flooded ACCG75213 208-230/3/60 -20 F Flooded ACCG75214 480/3/60 -20 F Flooded ACCG75238 208-230/1/60 -30 F Flooded ACCG75239 208-230/3/60 -30 F Flooded ACCG75240 480/3/60 -30 F Flooded ACCG75215 208-230/1/60 -20 F Flooded ACCG75216 208-230/3/60 -20 F Flooded ACCG75217 480/3/60 -20 F Flooded ACCG75241 208-230/1/60 -30 F Flooded ACCG75242 208-230/3/60 -30 F Flooded ACCG75243 480/3/60 -30 F Flooded APC NetworkAIR™ CM Pump Specifications Pump performance 130 40 120 25 20 5 BHP ABSORBED 15 TOTAL DYNAMIC HEAD IN FEET 30 10 3600 R.P.M. 110 100 100 90 90 80 80 70 70 1 HP 60 60 0.75 HP 50 40 50 40 0.5 HP 30 30 20 20 10 10 PERCENT EFFICIENCY TOTAL DYNAMIC HEAD IN METERS 35 0 10 0 20 1.0 30 40 50 60 70 80 90 100 110 120 130 CAPACITY IN U.S. GALLONS PER MINUTE 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10 CAPACITY IN LITERS PER SECOND Pump connection sizes HP (kW) 1/2 (.37) 3/4 (.56) 1 (.75) LINE Suction Discharge Suction Discharge Suction Discharge Size (inches) 1-1/4 1 1-1/4 1 1-1/4 1 Pump electrical data HP (kW) 1/2 (.37) 3/4 (.56) 1 (.75) VOLTAGE FLA MCA FLA MCA FLA MCA 208-230/3/60 2.4 3.0 3.5 4.4 4.6 5.8 480/3/60 1.1 1.4 1.6 2.0 2.1 2.6 *Values are calculated based on 3-phase power. FLA = Full Load Amperes MCA = Minimum Circuit Amperes APC NetworkAIR™ CM 37 Pump Specifications 3-17kW (1-5 ton) Single Pump Package * All dimensions are in inches (mm). 3-17kW (1-5 ton) Dual Pump Package * All dimensions are in inches (mm). 38 APC NetworkAIR™ CM Guide Specifications PART 1 — PART 1 GENERAL 1.01 SUMMARY A. The environmental control system shall be designed specifically for precision temperature and humidity control applications. It will automatically monitor and control heating, cooling, humidifying, dehumidifying, and filtering functions for the conditioned space. The evaporator airflow pattern shall be spot-cooled or ducted. 1.02 DESIGN REQUIREMENTS A. The system shall be as described in the following specification as manufactured by APC. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10 . 11 . 12 . 1.03 Model: ____________________________. Total cooling capacity: _______________ MBH (kW). Sensible cooling capacity: _____________ MBH (kW). Return air temperature: _______________ º F (º C) DB. Return air temperature: _______________ º F (º C) WB. Entering Chilled Water: _______________ º F (º C) Leaving Chilled Water: ________________º F (º C) Humidity: __________________________% RH. Air quantity: _______________________ CFM (L/s). External Static Pressure _______________inches (Pa). Humidifier capacity: _________________ lbs/hr (kg/hr). Electrical supply: ________ V, _________ ph, 60 Hz. SUBMITTALS A. Submittals shall be provided with the proposal and shall include: capacity data, electrical data, physical data, electrical connection drawing, and piping connection drawing. 1.04 QUALITY ASSURANCE A. The system shall be completely factory-tested prior to shipment. Testing shall include, but not be limited to: complete pressure and leak testing to ensure system integrity, “Hi-Pot” test, and controls calibration and settings. Each system shall ship with a completed test report to verify completion of factory testing procedure. The system shall be NTRL listed, MCA, and electrical system shall be UL Listed to UL 1995 and CSA 22.2 No. 236. 1.05 WARRANTY A. System parts shall be warranted for a period of 12months from date of shipment from factory. APC NetworkAIR™ CM 39 Guide Specifications PART 2 — PART 2 PRODUCT 2.01 STANDARD COMPONENTS A. THERMOSTAT CONTROLLER 1 . The unit control shall provide two separate heat and cool temperature setpoints with a minimum 2 degree spacing between them. The controller shall activate heating or cooling functions automatically in regards to setpoint versus measure conditions. The control setpoint rate shall be 60-85 degrees F. Units requiring humidity control shall have separate humidity and dehumidity setpoints with a minimum 4% RH spacing between them. B. CABINET CONSTRUCTION 1 . The cabinet and frame shall be constructed from welded structural steel. hanger mounting brackets shall be part of the chassis and shock mounts shall be provided for vibration isolation. The unit shall offer service access to all components via removable access panels lined with 1/2” thick insulation for noise reduction. C. FAN/MOTOR SECTION 1 . The air distribution system for the 3-10kW (1-3 ton) units shall be comprised of a directdrive fan motor with a double-inlet blower and permanently sealed ball-bearing type blower bearings. The air distribution system for the 14-17kW (4-5 ton) units shall be comprised of a belt drive fan motor with a double-inlet blower and permanently sealed ball-bearing type blower bearings. D. ELECTRICAL PANEL 1 . The electrical system shall conform to National Electrical Code (NEC) requirements. The control voltage shall be 24 VAC, wired in accordance with NEC Class 1 requirements. The wire for the control circuit shall not be smaller than 18-gauge AWG. Each wire shall end with a service loop and be securely fastened by an approved method. Control wires more than 6 in. (150 mm) shall be color-coded or numbered every 3 in. (80 mm) for ease of service tracing. All electrically-actuated components shall be easily accessible from the front of the unit. EAch high voltage unit shall be individually protected on all three phases. Main power shall be connected to a circuit breaker mounted on the electrical panel. The compressor and motor shall have overload and short circuit protection. The electrical box shall include all components and controls required for system operation. AN emergency cool override manual switch shall be provided with provision for control using a field supplied thermostat. Incoming power is _________ V, _________ phase, 60 Hz. E. REFRIGERATION SYSTEM AND COMPRESSOR 1 . Each refrigeration system shall consist of a single hermetic compressor, externally equalized expansion valve, filter-dryer, high pressure switch, refrigerant sight glass, and moisture indicator. 40 APC NetworkAIR™ CM Guide Specifications F. EVAPORATOR COIL & DRAIN PAN 1 . The evaporator coil shall use the latest heat-transfer technology, raised lanced-aluminum fins and rifle-bored copper tubes. Coil end-supports shall be galvanized steel. An insulated stainless steel drain pan for condensate shall be included. G. CHILLED WATER COIL 1 . The cooling coil shall be constructed of copper tubes and aluminum fins and shall be mounted over a stainless steel condensate drain pan. The coil circuiting shall ensure water distribution over the entire coil face area. Capacity, chilled water flow rate, and system pressure drop shall be based on an entering water temperature of 45º F (7.2º C) and leaving water temperature of 55º F (12.8º C). 2.02 OPTIONAL COMPONENTS A. CONDENSER 1 . The 3-10kW (1-3 ton) water and glycol cooled systems shall employ a coaxial style condenser that uses efficient tube within a tube counterflow heat transfer to remove the heat of compression. The 14-17kW (4-5 ton) models shall employ a brazed plate condenser that uses the latest heat transfer technology. Type 316L stainless plates shall be brazed together in a vacuum furnace and shall comply with ASME pressure vessel code. B. WATER-REGULATING VALVES 1 . Water and glycol systems shall utilize two-way or three-way valves to regulate the amount of water or glycol supplied to the condenser in response to refrigerant discharge pressure. The standard valve pressure rating shall be 150 psi (1030 kPa). 2 . Valves with a pressure rating of 350 psi (2413 kPa) ship loose for field installation. Space restrictions within the cabinet prevent the valves from being factory installed when reheat and humidity are selected. C. CHILLED WATER CONTROL VALVE 1 . Cooling capacity shall be controlled with a slow-close, 2-way, motorized valve rated for 125 psi (862 kPa). D. AIR FILTER 1 . A 20” x 20” x 1” (508 mm x 508 mm x 25 mm), 30% efficient ASHRAE 52.1-92 return air filter shall be integrally mounted on all 3-10kW (1-3 ton) systems. Two 16” x 25” x 1” (406mm x 635mm x 25mm), 30% efficient ASHRAE 52.1-92 return air filters shall be integrally mounted on all 14-17kW (4-5 ton) systems. APC NetworkAIR™ CM 41 Guide Specifications E. MICROPROCESSOR CONTROLLER W/REMOTE DISPLAY 1 . The microprocessor controller shall provide total environmental control. The system, based on the main controller, shall offer up to eight analog inputs, two analog outputs, twelve digital inputs and thirteen digital outputs. The operator interface shall provide a 4line, 80-character backlit LCD display. User-friendly menu structure along with clearly defined prompts shall allow the operator to easily move about the program and monitor the following functions and alarm conditions. a. Status: Complete status monitoring shall be provided within the status menu of the microprocessor controller, and shall include the following information: current temperature, current humidity, temperature setpoint, humidity setpoint, cooling status, heating status, humidification status and dehumidification status. b. Alarms: Quick access to any alarm condition shall be facilitated through the menu structure. Presence of a new alarm shall sound an audible alarm. A red alarm LED on the display panel shall remain illuminated until such time that all alarms have been cleared. Alarm annunciation shall include: loss of airflow, clogged filter, high head pressure, low suction pressure, high temperature, low temperature, high humidity, and low humidity. The temperature and humidity alarm setpoints are user adjustable. c. Setpoint: The microprocessor controller shall provide independent setpoints for heating, cooling, humidification, and dehumidification. Automatic setpoint cross-over protection shall prevent the setting of the heat setpoint above the cool setpoint and the humidify setpoint above the dehumidify setpoint. Setpoint adjustment shall be capable of being protected via security code. d. Configuration: Flexibility shall be offered through the use of the configuration menu. Site configuration shall be stored in the EEPROM and be protected from unauthorized tampering by the user selectable 4-digit security password in the security menu. Configuration options shall include: Fahrenheit or Celsius display, compressor minimum off-time, power-loss restart time-delay, primary-secondary transfer functions, alarm input polarity, alarm enable, temperature deadbands, humidity deadbands, and small room delay. e. Run time: The major components within the unit shall have independent run-timers that monitor and store accumulated run-hours on the components. Run timers shall be provided with operator-adjustable run-time alarms for component maintenance. f. Security: The microprocessor shall have multiple security levels to prevent unauthorized adjustment of the important system parameters. A user-selectable 4-digit password shall allow setpoint and configuration changes. F. MICROPROCESSOR CONTROLLER W/REDUNDANT GROUP CONTROL 1 . Up to six units shall have the ability to communicate with each other to automatically switch upon alarm condition, or time rotation. 42 APC NetworkAIR™ CM Guide Specifications G. MICROPROCESSOR CONTROLLER W/REMOTE SENSOR(S) 1 . Environmental sensor(s) shall be strategically placed, up to 50ft from the unit to better meet the site’s cooling needs. The sensor shall be positioned to permit air movement across the sensor. H. PROGRAMMABLE THERMOSTAT/HUMIDITY CONTROLS 1 . The system shall be supplied with a wall-mount programmable thermostat for temperature control. The thermostat shall have full seven-day programming flexibility with battery backup and an LCD display. The display shall continuously indicate time-of-day, day-ofweek, current program period and current room temperature. When equipped with a humidifier and/or reheat, a hair-element humidistat and/or dehumidistat shall be supplied to control humidification and/or dehumidification. I. REMOTE RELAY SHUTDOWN 1 . Remote shutdown of the system can be done by a factory installed relay with a 24V, 120V, or 240V coil. The relay must be powered by others to disable the cooling system. J. REHEAT/HUMIDITY LOCKOUT 1 . When facilities have limited backup power capacity, this lockout shall prevent the operation of electrical loads that are not essential for continued site operation. K. HUMIDIFIER 1 . Humidifier shall be self-contained steam-generating type, factory piped and wired, with disposable cylinder and automatic solid-state control circuit. Capacity: ______ lb/h (g/s). L. OPTIONAL BLOWER/MOTOR HP 1 . An optional 5HP motor shall be used for increased CFM or to accommodate special air filters, high external static pressure, etc. while maintaining the standard CFM rating. M. ELECTRIC REHEAT 1 . Reheat elements shall be low watt density, loaded equally on all phases and shall be electrically and thermally protected by both automatic and manual reset thermal cutouts. Reheat capacity shall be ___________ MBH, ___________ kW, controlled in ________ (#) steps. N. HOT GAS REHEAT 1 . The water- or glycol-cooled unit shall be supplied with a factory-installed copper tube and aluminum fin hot gas reheat coil. The coil shall be controlled by the main controller through a factory piped and wired three-way heat reclaim regulator and check valve. APC NetworkAIR™ CM 43 Guide Specifications O. HOT WATER REHEAT (MODULATING) 1 . The unit shall be supplied with factory-installed copper tube, aluminum fin, and hot water reheat coil in place of electrical heater elements. Capacity shall be ________ MBH (kW), with ________ GPM (L/s) of ________ º F (º C) entering hot water temperature. Hot water shall be controlled with a modulating control valve. P. HOT WATER REHEAT (2-WAY ON/OFF) 1 . The unit shall be supplied with a factory-installed copper tube, aluminum fin, reheat steam-coil in place of electrical heat elements. Capacity shall be _______MBH (kW) with 5 psi (35 kPa) of saturated steam. Steam shall be controlled with an on/off solenoid valve. Q. FUSED DISCONNECT 1 . A NEMA 1 fused disconnect, complete with fuses, shall ship loose for field installation. R. HOT GAS BYPASS 1 . Activation of the hot gas bypass circuit shall maintain the evaporator coil temperature during low load conditions. S. SHIP LOOSE SPOT WATER DETECTOR 1 . A water detector shall ship loose for field installation into ductwork. Upon sensing liquid, unit shall send a signal to the master control giving the operator possible alarm indication options for shutdown. The water detector shall be provided with 15 ft (5 m) of wire. T. SHIP LOOSE FIRESTAT 1 . A firestat shall ship loose for field installation into ductwork with a sensing element within the ductwork. Upon sensing of a high temperature, the unit shall send a signal to the main controller shutting down the unit and activating a visual and audible alarm. U. SHIP LOOSE SMOKE DETECTOR 1 . A smoke detector shall ship loose for field installation into ductwork. Upon sensing smoke the main controller shall shut down the unit and activate a visual and audible alarm. V. SHIP LOOSE CONDENSATE PUMP 1 . The Condensate Pump shall ship loose for field attachment to the side of the unit. The condensate pump shall be complete with a 1.7qt. (1.6L) reservoir, float switch, and pump/ motor assembly and shall pump 36 gal/h (0.06 L/s) at 15 ft. (4.6m) head. 44 APC NetworkAIR™ CM Guide Specifications W. ENVIRONMENTAL MONITORING AND MANAGMENT 1 . Environmental Monitoring Unit: A stand-alone unit shall perform continuous temperature and humidity sensing through two available proves and contact monitoring. Unit shall be controlled by available web, control console, or SNMP interface with network connection. In the event of an environmental anomaly, notification shall be sent to the customer via email or SNMP. The unit shall be 18.25”x9”x2.75”(464mm x 229mm x 70mm). 2 . Environmental Management System: A browser-accessible, 1U, rackmountable appliance shall allow monitoring of environmental conditions. Monitoring of one temperature, one humidity, and one vibration sensor shall ship standard. When conditions change, notifications shall be sent via email to the appropriate personnel. The EMS shall provide eight input contacts, 2 output relays, and controllable power outlets for defining actions remotely should conditions warrant it. X. MODBUS/JBUS GATEWAY 1 . The Gateway shall translate transmission protocol from the system’s network into ModBus/JBus communication protocol. One gateway shall support up to 16 units. Y. OHE DISCONNECT 1 . A non-fused disconnect switch shall be wired to an outdoor heat exchanger to disconnect high voltage power if necessary. APC NetworkAIR™ CM 45 Guide Specifications PART 3 — PART 3 INDIVIDUAL SYSTEMS 3.01 AIR-COOLED A. The indoor unit shall consist of an evaporator section including evaporator coil, blower package, controls, electrical section, and compressor. B. CONDENSER 1 . Outdoor Propeller Fan Condenser: The outdoor condenser casing shall be made of aluminum, and all structural supports, coil frame, motor drive supports, and mounting legs shall be made of galvanized steel. The condenser shall have copper tubes expanded into aluminum fins. Headers and connections shall be copper. The coil shall be pressure tested and sealed for shipment. The condenser motors shall have permanently lubricated, sealed, ball bearings, and internal overload protection and operate on ________ V, ________ ph, 60 Hz power. Motors shall be 1140 RPM and mounted inside the condenser casing for weather protection, and shall be wired to a terminal strip in a weatherproof panel on the unit. The direct drive, aluminum fan blade and painted steel hub assembly, shall be protected by a heavy-gauge, vinyl-coated, steel-wire fan guard. On multiple units, each fan section shall be separated by full-width baffles to prevent bypass air. The condenser shall be sized for ________ º F (ºC) ambient, and condensing temperature controls shall be fan speed for -20º F (-29º C) winter ambient. 2 . Flooded Controls: Flooded controls shall maintain head pressure to -30º F (-34.4ºC) by regulating the effective condensing area within the condenser coil. Controls shall ship loose. Receiver shall be insulated in the field and equipped with a field supplied heater. C. CONDENSING UNIT 1 . Outdoor Propeller Fan Condensing Unit: The remote outdoor propeller type air-cooled condensing unit shall consist of a copper tube/aluminum fin condenser coil and a directdrive propeller fan(s). The fan blades are aluminum and riveted to painted steel spider and hub. Head pressure control down to -20º F (-29º C) shall be achieved by installation of flooded controls. A head pressure control valve shall bypass the condenser coil to maintain a desirable condensing temperature. 3.02 WATER-COOLED A. The water-cooled system shall consist of an evaporator section including evaporator coil, blower package, controls, electrical section, compressor, and water-cooled condenser. The condenser shall be stainless steel brazed plate design and shall be controlled by 2-way (3-way optional) head pressure-regulated valve. Maximum water pressure shall be 400 psi (2758 kPa). 46 APC NetworkAIR™ CM Guide Specifications 3.03 GLYCOL-COOLED A. The glycol-cooled system shall consist of an evaporator section including evaporator coil, blower package, controls, electrical section, compressor, and glycol-cooled condenser. The condenser shall be stainless steel brazed plate design and shall be controlled by 2-way (3-way optional) head pressure-regulated valve. Maximum water pressure shall be 400 psi (2758 kPa). B. FLUID COOLER 1 . Outdoor Fluid Cooler: The fluid cooler casing shall be of aluminum, and all structural supports, coil frame, motor-drive supports, and mounting legs shall be made of galvanized steel. The fluid cooler coil shall have copper tubes expanded into aluminum fins. Headers and connections shall be copper. The coil shall be pressure-tested and sealed for shipment. The fluid cooler motors shall have permanently lubricated, sealed, ball bearings, and internal overload protection. Motors shall be mounted inside the fluid cooler casing for weather protection and wired to a terminal strip in a weatherproof panel on the unit. The direct-drive, aluminum fin blade and painted steel hub assembly shall be protected by a heavy-gauge, vinyl-coated, steel-wire fan guard. On multiple fan units, each fan section shall be separated by full-width baffles to prevent bypass air. The Fluid Cooler shall be sized for 95º F (35º C) ambient, and operate on ________ V, ________ ph, 60 Hz power. C. PUMP PACKAGE 1 . Single Pump Package: The pump package shall be comprised of a centrifugal pump in a vented enclosure with pump starter, separate Fluid Cooler fan and pump circuit breakers, Aquastat, and fan cycling contractors to control the fluid temperature. The controls shall be mounted in a weather-tight box. A _______ gal (L) expansion tank and Airtrol fitting shall be supplied for field installation. The pump size shall be sized for ________ GPM (L/s) at ________ ft (m) external head, and operate on ________ V, ________ ph, 60 Hz power. 2 . Dual Pump Package: The dual pump package shall consist of two centrifugal pumps in an enclosure. Pump starters, automatic pump switch-over controls, lead-lag pump selector switch, separate Fluid Cooler fan and pump circuit breakers, Aquastat, and fan cycling contractor to control the fluid temperature shall be mounted in a separate weather-tight box. A _______ gal (L) expansion tank and Airtrol fitting shall be supplied for field installation. Each pump shall be sized for ________ GPM (L/s) at _________ ft (m) external head, and operate on ________ V, ________ ph, 60 Hz power. APC NetworkAIR™ CM 47 Guide Specifications 3.04 ECONOMIZER A. Glycol systems shall have the option of an economizer coil that is designed to reduce operating costs during mid to low ambient temperatures. Economizer cooling coil shall be copper tube, aluminum fin coil located in the return air before the V-Frame evaporator coil. The economizer coil shall be rated at ____BTU/HR (kW) sensible cooling capacity with a 45 F (7.2 C) entering glycol solution temperature. The economizer coil shall require ____ GPM (l/s) and the total unit pressure drop shall not exceed ____feet of water (kPa), when in the economizer mode of operation. 3.05 MULTICOOL A. Air, Water and Glycol systems shall have the option of a chilled water coil that is designed to be the primary cooling source to the backup direct expansion coil. The MultiCool (chilled water) coil shall be constructed with copper tubes and aluminum fins. It shall be located in the return air, before the V-Frame evaporator coil. The MultiCool coil shall be rated at ____BTU/ HR (kW) sensible cooling capacity with 45 F (7.2 C) entering water temperature. The MultiCool coil shall require ____GPM(l/s) of chilled water and the pressure drop shall not exceed ____psig (kPa). 3.06 CHILLED WATER A. The unit shall be piped in accordance with the highest commercial quality procedures. All pipe shall be type “L” copper. All pipe forming shall be tool bent with proper bend radii to prevent tube flattening in the curve. The chilled water piping shall be insulated with closed cell neoprene thermal insulation. the chilled water flow shall be controlled by a 3-way valve (2way valve optional) with a 24 VAC modulating motor. 48 APC NetworkAIR™ CM Guidelines for Installation The CM provides reliable, accurate temperature and humidity control of computer rooms, laboratories, and other environments that require close tolerance control. The unit incorporates the latest system design innovations to provide you with optimum efficiency, reliability, and accuracy of control. The CM system will provide years of trouble-free service, when installed and maintained by technically qualified personnel. Room preparation During the design of the room, consideration should be given to the following factors: ease of entry for the system and accessibility of piping and wiring. The room must be sealed with a vapor barrier to minimize migration of moisture. Polyethylene film (plastic sheeting) is a good vapor barrier for ceiling and wall applications. Rubber- or plastic-based paints should be applied to concrete floors and walls. The room should be thoroughly insulated to minimize thermal loads and make-up air (if required) should be preconditioned to reduce additional temperature, filtration, and moisture loads. APC should be notified before installation if the unit is incorrect for the application. Unit location The location of the unit is important for efficient and balanced environmental control in your room. The air conditioner should be located as close as possible to the largest heat load. If improperly installed, erratic control or mechanical failure can and will result. Service access At least 24" (610 mm) of clear space must be left in front of the unit for routine service (filters, humidifier). We strongly recommend approximately 32" (813 mm) clearance in front of the unit. APC NetworkAIR™ CM 49 Guidelines for Installation Receiving the unit Your CM unit has been completely tested and inspected prior to shipment. To ensure that you have received the unit in excellent condition, perform a careful inspection of the crating and the unit immediately upon receipt. Verify that all parts ordered were received as specified and that the unit is the correct size and voltage necessary to fulfill your environmental control needs. Report any damage discovered to the freight carrier. If necessary, contact the APC field service department for help in repairing or replacing damaged parts. While APC is not responsible for damage incurred in transit, we want to make sure that you have no undue delays in your system start-up. Rigging The unit is manufactured with a formed steel frame for maximum strength and unit integrity. However, as with all electrical and mechanical equipment, you must take care with proper rigging of your unit. When using a forklift to move the unit, use the shipping skid to protect the bottom of the unit. When using chains, cables or rope to lift the unit, use spreader bars to prevent damage to the finished panel. Utility connections All connections are made through the bottom left of the unit for ease of service connections. Refer to the installation manual for pipe sizes and specific locations for your unit. Power unit The CM unit uses either 1-phase or 3-phase power for operation depending on the unit. Bring the service cable through the bottom left of the unit and through the bulkhead hole into the electrical box to the circuit breaker provided on the left side of the electrical box. The ground lug is located near the 3-phase high-voltage connector. THE UNIT MUST BE UTILITY GROUNDED OR THE WARRANTY IS VOID. Humidifier connections The humidifier inlet connection point is provided with the equipment. A 1/4" (6.4mm) compression connection is supplied with the unit. Condensate drain Condensate from the evaporator pan is collected and discharged by the condensate pump to a 7/8" (22.2mm) fitting for field connection. 50 APC NetworkAIR™ CM Guidelines for Installation Water supply to humidifier 1. The humidifier fill valve orifice is sized for supply water pressure from 15 PSIG (103.4 kPa) to 150 PSIG (1034 kPa). 2. For cases above 150 PSIG (1034 kPa), install a pressure-reducing valve in the water feed line to the unit. 3. With extremely dirty or muddy water sources, proper filtration is required on the unit’s incoming water line. 4. DO NOT use softened water with the humidifier. Softened water is too conductive. 5. DO NOT use completely demineralized water with the humidifier. The minerals allow the electrode principle to work. 6. DO NOT use a hot water source. Doing so will cause deposits that will eventually block the fill valve orifices. 7. Water supplies with high conductivity (above 800 mW) must be preconditioned for proper operation and longevity of the humidifier. Water supply A 16- to 20-mesh strainer must be installed in the water supply to the water units to prevent clogging of brazed plate condenser. This is a field item.Also recommended on glycol units. Note: Because of an ongoing program dedicated to product improvement, specifications are subject to revisions without notice. APC assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. APC NetworkAIR™ CM 51 52 APC NetworkAIR™ CM ® APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways: • Visit the APC Web site to find answers to frequently asked questions (FAQs), to access documents in the APC Knowledge Base, and to submit customer support requests. – www.apc.com (Corporate Headquarters) Connect to localized APC Web sites for specific countries, each of which provides customer support information. – www.apc.com/support/ Global support with FAQs, knowledge base, and e-support. • Contact an APC Customer Support center by telephone or e-mail. – Regional centers: APC headquarters U.S., Canada (1)(800)800-4272 (toll free) Latin America (1)(401)789-5735 (USA) Europe, Middle East, Africa (353)(91)702020 (Ireland) Asia Pacific (61) 2 9955 9366 (Australia) – Local, country-specific centers: go to www.apc.com/support/contact for contact information. Contact the APC representative or other distributor from whom you purchased your APC product for information on how to obtain local customer support. Entire contents copyright © 2004 American Power Conversion. All rights reserved. Reproduction in whole or in part without permission is prohibited. APC, the APC logo, and NetworkAIR are trademarks of American Power Conversion Corporation and may be registered in some jurisdictions. All other trademarks, product names, and corporate names are the property of their respective owners and are used for informational purposes only. 990-7205E-EN 10/2004
© Copyright 2026 Paperzz