Pocket Pump Sample Pump Cat. No. 210

Publication 1307 Rev 1512
Pocket Pump Sample Pump
Smallest Programmable Low Flow Pump Available!
Certifications
Flows: 20 to 225 ml/min
intrinsically safe
ATEX-approved model
available; contact SKC
Battery status indicator
dicator
CD
Easy-to-read LCD
Easy operation and
programmability
4.5 inches
Pocket Pump® in singletube sample train
2.2 inches
 Constant flows from 20 to 225 ml/min
 Smart charging
• Accommodates typical flow rates for sorbent tubes
• Automatically senses maximum charge and switches to trickle charge
to prolong battery life and prevent damage; it never overcharges
 Programmability in a pump that fits into a shirt pocket
 Large easy-to-read LCD
• Easy three-button pump operation; no tools needed
• Only 5 ounces (142 grams)!
• 4.5 x 2.2 x 1.4 inches (11.4 x 5.6 x 3.6 cm)
• Displays sampling parameters, battery status, and flow fault at
the touch of a button
 Constant flow and constant pressure modes
 Intrinsically safe
• For single-tube sampling and time-saving multiple-tube sampling
 Features maintain sample integrity
 Twin port model available for bag sampling
•
•
•
•
 12+ hours extended run time at 200 ml/min with NiMH battery
• Continuous run with AC adapter for 24-hour sampling
 PC programmable with DataTrac Software
• Program delayed start, timed run, or multiple sampling schedules
• Download sampling data to a PC for record keeping and data analysis
SKC Inc. 724-941-9701
SKC-West 714-992-2780
Low battery and restricted flow shut-off
Auto-restart attempted after flow fault
Run time data stored in pump memory
Security code minimizes accidental changes or tampering and
maintains sample validity
• RFI/EMI shielded and CE marked
• Impact-resistant case features sliding cover to protect keypad and
interface port; withstands rough handling in the industrial workplace
SKC Gulf Coast 281-859-8050
www.skcinc.com
SKC South 434-352-7149
Quick View
Pocket Pump Sample Pump
Performance Profile
Flow Control Accuracy
Typical Run Time
(NiMH)
Charge Time
(varies with battery capacity
and level of discharge)
Temperature Range
Flow Fault
Timer
± 5% of set-point in constant flow mode after calibration
12 hrs at 200 ml/min up to 10 inches water back pressure
Using charger with AC power: Extended run time
≤ 6 hrs with Pocket Pump charger (battery attached to pump); approximately 16 hrs with
charger (battery detached from pump)
Operating: 32 to 104 F (0 to 40 C)
Charging: 40 to 100 F (5 to 38 C)
Storage: -4 to 113 F (-20 to 45 C)
After 15 sec, pump goes into Hold, retains accumulated run time display, and displays fault
icon. After 5 min, auto-restart is attempted every 5 min until flow is corrected or fault mode
is cancelled.
1 to 9999 min display ± 1% accuracy
Ordering Information
Pocket Pump requires 1/4-inch ID tubing.
Pump and Kits
Pocket Pump only with NiMH battery and screwdriver set,
requires charger; see kits or chargers below
Pocket Pump (as described above) and Charger
Cat. No.
210-1002MH
115 V
210-1000MH
100-240 V 210-1001MH
Twin Port Pocket Pump (for bag sampling) with NiMH battery (not UL Listed for
intrinsic safety) and screwdriver set, requires charger Cat. No. 223-228 or 223-229A
below; requires tubing Cat. No. 231-9-23 and 231-926 for bag sampling
Twin Port Pocket Pump, ATEX approved for intrinsic safety, with NiMH battery
pack, requires charger Cat. No. 223-228 or 223-229A below; requires tubing Cat. No.
231-9-23 and 231-926 for bag sampling
Starter Kit includes pump as described above, single charger, Tygon tubing
(3 feet, 1/4-inch ID), and collar clip with cable tie
Single Pump Kit includes pump as described above, single charger, and
Type A single tube holder, in a soft-side nylon carry case†
5-pack Pump Kit with Single Chargers includes 5 pumps as described above,
single chargers, and Type A single tube holders, in a Pelican case
5-pack Pump Kit with Multi-charger includes 5 pumps as described above and
Type A single tube holders and one 5-station multi-charger, in a Pelican case
Accessories
Chargers, suitable for NiMH and NiCad batteries
5-station
210-1002A
115 V
100-240 V
115 V
100-240 V
115 V
100-240 V
115 V
100-240 V
115 V
100-240 V
Single (also a
115 V
battery eliminator) 100-240 V
DataTrac for Pocket Pump Software includes software on CD and USB cable
Replacement Parts
Replacement Pump Battery Packs‡
NiMH
NiCad
210-1003MTX
210-1000MH-S
210-1001MH-S
210-1000MHK
210-1001MHK
210-1000MHK5
210-1001MHK5
210-1000MH5D
210-1001MH5D
223-427
223-107A
223-228
223-229A
877-90
P20129-2‡
P20129-1‡
† Single kit also available in hard-sided Pelican case; contact SKC
‡ Replacing batteries with non-approved battery packs voids any warranty and UL intrinsic safety approvals.
SKC Limited Warranty and Return Policy
SKC products are subject to the SKC Limited Warranty and Return Policy, which provides SKC’s sole liability
and the buyer’s exclusive remedy. To view the complete SKC Limited Warranty and Return Policy, go to http://
www.skcinc.com/warranty.asp.
SKC Inc. 724-941-9701
SKC-West 714-992-2780
SKC Gulf Coast 281-859-8050
www.skcinc.com
Flow Rate (ml/min)
20 to 225 (all models)
Weight in Ounces (grams)
5 (142)
Compensation Range (inches water)
Up to 20 at 225 ml (constant flow)
Built-in Timer/Clock
Timer
Constant Flow
Yes
Programmable
Yes
PC-compatible
Yes
Multi-tube Sampling
Yes
Flow Fault Feature
Yes
RFI/EMI Shielded
Yes
Intrinsically Safe — UL Listed
Yes (single port models)
MSHA-approved Models Available
N/A
ATEX Models Available
Yes
CE Marked
Yes
Corrects for Changes in
Atmospheric Pressure
N/A
Corrects for Changes in
Temperature
N/A
Battery Type
NiMH (2.4 V, 1.0 Ah) or
NiCad (2.4 V, 0.6 Ah)
Battery Check
Yes
Tubing
Requires 1/4-inch ID tubing
Recommended Accessories
Chargers
Battery Eliminator
DataTrac for Pocket Pump Software
Cat. No. 877-90
Constant Pressure Controller (CPC)
Cat. No. 224-26-CPC
Single Tube Holder
Adjustable Multiple Tube Holders
Tubing
Kit Cases
SKC South 434-352-7149