TECHNICAL DATA - FRAMES STANDARD PROFILES ______________________________________________________________________________________ ENGINEERING DETAILS for STEEL FRAMES Type 3 (Standard Profile) Scope 5/8” Series 18 Ga. 16 Ga. 14 Ga. 12 Ga. = = = = 1 5/32” 1 5/32” 1 5/32” 1/2" Profile 3/2 Double Rabbet Variation 2” JAMB WIDTH F12 F14 F16 F16 UNIFRAME F18 WF14 WF16 WF18 KD Knoc ked Down Setup & Welded Fire Rated SCOPE data above intended only as a guideline as it applies to the product information covered on this page. We recommended you verify all data as to application * 7/16 “ at standard 5 3/4"Profile Dimensions shown are standard for this profile. Variations to suit designed conditions are available Profile 3/1 Single Rabbet Variation © PIONEER INDUSTRIES2007. STANDARD PROFILE Profile 3/0 Cased Opening Variation DATA SHEETS REV 6/2007 TECHNICAL DATA - FRAMES STANDARD PROFILES ______________________________________________________________________________________ ENGINEERING DETAILS for STEEL FRAMES Type 4 (Drywall Double Return) Scope 5/8” 20 Ga. 18 Ga. 16 Ga. 14 Ga. 12 Ga. = = = = = 3/8” 17/32” 17/32” 5/8" 3/4" Profile 4/2 20 Ga. 18 Ga. 16 Ga. 14 Ga. 12 Ga. = = = = = 3/8” 3/8” 3/8” 5/8" 3/4" Double Rabbet Variation JAMB WIDTH Series KD Knocked Down DW 14 DW 16 DW 18 DWF 14 DWF 16 DWF 18 Setup & Welded Fire Rated SCOPE data above intended only as a guideline as it applies to the product information covered on this page. We recommended you verify all data as to application 2” Dimensions shown are standard for this profile. Variations to suit designed conditions are available Profile 4/1 Single Rabbet Variation © PIONEER INDUSTRIES2007. STANDARD PROFILE Profile 4/0 Cased Opening Variation DATA SHEETS REV 6/2007