Submittal Data

EXTROL® Expansion Tanks
In-Line Models
Specifications and Dimensions
Model Tank Acceptance
A
B
System Ship
No. Volume Volume HeightDiameter
Conn.1Wt.
LitersGallons LitersGallons mm inches mminches inches kg lbs.
15 8 2.03.40.9321125⁄8203 8 1⁄22.3 5
30 174.49.52.53811527911 1⁄24.0 9
60 337.69.52.55842327911 1⁄27.014
1⁄
90 53 14.042.011.3533 21390153⁄8
210.023
EXTROL®
Specifications and Dimensions
Model TankAcceptance
A
B
No. Volume Volume Height Diameter
LitersGallons Liters Gallons
mm inches mm inches
109 8 2.03.40.9375143⁄4203 8
110174.49.52.5441173⁄8279 11
111337.69.52.5625245⁄8279 11
112 53 14.042.011.3584 23390153⁄8
System Ship
Conn.1Wt.
inches
kg lbs.
1⁄
22.7 6
1⁄
24.510
1⁄
26.815
1⁄
210.824
FILL-TROL®
Maximum Operating Conditions
Operating Temperature
Working Pressure
240°F (115°C)
100 PSIG (7 bar)
All dimensions and weights are approximate.
Job Name ____________________________________________
Contractor___________________________________________
Location____________________________________________
Contractor P.O. No.
____________________________________________
Sales Representative __________________________________
____________________________________________
Model No. Ordered
__________________________________
__________________________________
Engineer____________________________________________
Rev. 04/11
P/N 4400-026
Submittal data sheets can ONLY be ordered as a “Submittal Data Sheet Pack”, using MC# 4400. They are not available to order on an
individual basis, however each data sheet is available on the AMTROL Web Site and can be downloaded and printed for use as needed.
For the most updated technical specifications, please download sheet at www.amtrol.com
26
EXTROL® Specialty
Expansion Tanks
In-Line Models
Specifications and Dimensions
Model TankAcceptance
A B
System Ship
No. Volume Volume HeightDiameter
Conn.1
Wt.
Liters Gallons Liters Gallons mminches mminches inches kg lbs.
SolarEXTROL®
S-158 2.03.40.9321125⁄8203 8 1⁄22.3 5
S-30174.49.52.53811527911 1⁄24.0 9
S-60337.69.52.55842327911 1⁄27.014
Maximum Operating Conditions
SolarEXTROL®
Maximum Intermitant Temperature
Maximum Continuous Temperature
Working Pressure
250°F (121°C)
225°F (107°C)
150 PSIG (10 bar)
All dimensions and weights are approximate.
Specifications and Dimensions
ModelTank
AcceptanceAB System
Ship
No.Volume VolumeHeight
Diameter
Conn.1Wt.
LitersGallons LitersGallons mminches mminches inches kglbs.
RX-15 82.0
RX-30 17 4.4
RX-60 5310.3
RADIANT EXTROL®
3.40.9 321
125⁄8
12.1 3.2 38115
39.010.3 489
191⁄4
203 8
279 11
390153⁄8
3⁄
4
3⁄
4
3⁄
4
2.35
4.09
10.023
Maximum Operating Conditions
Operating Temperature
Working Pressure
200°F (93°C)
100 PSIG (7 bar)
All dimensions and weights are approximate.
Job Name ____________________________________________
Contractor___________________________________________
Location____________________________________________
Contractor P.O. No.
____________________________________________
Sales Representative __________________________________
____________________________________________
Model No. Ordered
__________________________________
__________________________________
Engineer____________________________________________
Rev. 04/11
P/N 4400-027
Submittal data sheets can ONLY be ordered as a “Submittal Data Sheet Pack”, using MC# 4400. They are not available to order on an
individual basis, however each data sheet is available on the AMTROL Web Site and can be downloaded and printed for use as needed.
For the most updated technical specifications, please download sheet at www.amtrol.com
27