JOB NAME LOCATION PURCHASER ORDER NO. ENGINEER SUBMITTED TO Reference FOR: SUBMITTED BY Approval Construction DATE UNIT DESIGNATION: Schedule No. MODEL NO. DIMENSIONS – INCHES PRODUCT DATA TOTAL CAPACITY . . . . . . . . . . . . . . . . . MBH SENSIBLE CAPACITY . . . . . . . . . . . . . . MBH TOTAL SUPPLY AIR . . . . . . . . . . . . . . . . CFM TEMP. OF AIR ENTERING EVAPORATOR COIL . . . . . . . . . . . . . 7/8" HOLE W/BUSHING IN REAR PANEL (For Low Voltage Control Panel) 36-1/8 COOLING PERFORMANCE / 8-1/2 13-1/4 1-23/32 KNOCKOUT (Removed only when Electric Heat Accessory is used) AIR OUT 1 7/8" KNOCKOUT IN REAR PANEL (For Power Wiring) 3-7/8 4-1/2 HEATING PERFORMANCE 11-1/2 2-1/4 11-5/8 Refer to field-installed accessories on reverse side. 22-3/4 2-5/16 SUPPLY AIR BLOWER PERFORMANCE BLOWER MOTOR AND DRIVE ACCESS PANEL (This side inly) CFM TOTAL SUPPLY AIR . . . . . . . . . . . . . . . . TOTAL RESISTANCE EXTERNAL TO UNIT . . . . . . . . . . . . . . . . . . . . . . . IWG BLOWER SPEED. . . . . . . . . . . . . . . . . . RPM POWER OUTPUT REQUIREMENT . . . . BHP MOTOR RATING . . . . . . . . . . . . . . . . . . HP POWER INPUT REQUIREMENT. . . . . . KW ELECTRICAL DATA POWER SUPPLY . . . . . . . . . . . . . . . . . . 3/4 °F DB/WB FILTER ACCESS PANEL(This side only) 20 3-7/8 1-5/8 / HOLE WITH GROMMET FOR 7/8 O.D. SUCTION LINE 2 / 1-3/8 TOTAL UNIT AMPACITY. . . . . . . . . . . . . AMPS MINIMUM WIRE SIZE . . . . . . . . . . . . . . AWG 10-3/8 2 (Copper Conductors) 1-3/16 1-1/8 AIR IN MAXIMUM FUSE SIZE DUAL ELEMENT . . . . . . . . . . . . . . . . 22 32 AMPS UNIT WEIGHT LBS. TOTAL OPERATING WEIGHT . . . . . . . . 1 2 3 4 2 MATCHING CONDENSING UNIT DATA Model Number Submittal Form Number MINIMUM CLEARANCES Side with RETURN AIR opening . . . . . . . . . . 24" Side with SUPPLY AIR opening. . . . . . . . . . . 24" Side with PIPING CONNECTIONS . . . . . . . . 36" Side opposite PIPING CONNECTIONS . . . . 12" Side with access for both POWER & CONTROL WIRING . . . . . . . . . . — . 3 Bottom . . . . . . . . . . . . . . . . . . . . . . . . . . . . .— . 4 7/8 O.D. DRAIN CONN. (Must be trapped) NOTE: (Including field-installed accessories) 1 APPLICATION 2 Overall dimension of the unit will vary if an electric heater, a supply air plenum or a base is used. This dimension is required for removal of the coil. Only 26" is required for normal servicing. Although no clearance is required for service and operation, some clearance may be required for routing the power and control wiring. Allow enough clearance to trap the condensate drain line. SPLIT-SYSTEM EVAPORATOR BLOWER 5 TONS MODEL K—EU060 43-1/8 HOLE WITH GROMMET FOR 3/8 O.D. LIQUID LINE FORM 550.13-SD13Y (199) Supersedes: 550.13-SD13Y (1285) ® FIELD-INSTALLED ACCESSORIES SUPPLY AIR PLENUM (1SP0450) . . . . . . . . . . . . . . . . . . . . . . . . . . RETURN AIR GRILLE (1RG0450) . . . . . . . . . . . . . . . . . . . . . . . . . . BASE (1BS0450) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (Vertical Application Only) ELECTRIC HEATER* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Model Number Volts) . . . . . . . . . . . . . . . . . . . MBH Capacity (@ KW Power Input Requirement . . . . . . . . . . . . . . . . . . . . . . (Less Blower Motor) STEAM COIL (1NF0450). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Steam Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PSIG Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MBH LBS/HR Steam Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . °F Entering Air Temperature . . . . . . . . . . . . . . . . . . . . . . . HOT WATER COIL (1HW0450) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MBH °F Entering Water Temperature . . . . . . . . . . . . . . . . . . . . GPM Water Flow Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . °F Entering Air Temperature . . . . . . . . . . . . . . . . . . . . . . . PSI Water Pressure Drop . . . . . . . . . . . . . . . . . . . . . . . . . . * Units with electric heat have a single source power supply Refer to PRODUCT DATA on front side for electrical data. Four 3/8" – 16 weld nuts are provided in the unit support angles for ceiling suspension. Knockouts are provided in panels for access to these weld nuts. Support rods must be supplied in the field. SUSPENSION WEIGHTS, LBS. A B C D ACCESSORY DIMENSIONS – INCHES ELECTRIC HEATER 7 /8 1 SUPPLY AIR PLENUM 7 /8 2 0 -1 /8 4 1 /2 5 -1 /4 1 3 1 -1 1 /1 6 1 1 -1 /4 1 5 -3 /4 1 6 -7 /8 A C C E S S O P E N IN G F O R P O W E R S U P P L Y W IR IN G 7 -5 /8 1 -3 /4 2 4 -3 /8 2 3 /4 2 -1 /8 2 2 -1 /2 2 5 -1 /8 1 /2 L O C H E A P E N T H E A T T W E T B L IO N W IR IN G R A T E S O W E R H E H T U 3 1 -3 /4 3 6 BASE B A S E R E E L E C T R IC A R N E S S H E C A B IN E T O F N IT 2 5 -1 /8 2 -1 /8 2 - 1 /2 k n o c k o u t fo r p o w e r w ir in g w h e n e le c tr ic h e a te r is u s e d 2 0 RETURN AIR GRILLE 2 2 3 6 R E T U R N A IR G R IL L E HOT WATER COIL 3 6 STEAM COIL 5 5 3 -3 /8 2 1 -7 /8 2 1 " N P T E C O N N 'S . 1 -1 /2 " N P T E C O N N S . 2 1 -7 /8 6 -1 /4 3 6 C o il in s ta lls o v e r th e r e tu r n a ir o p e n in g o f th e u n itb e fo r e th e filte r s . 1 0 -5 /8 2 -3 /4 2 -5 /8 3 6 1 -1 1 /1 6 C o il in s ta lls o v e r th e r e tu r n a ir o p e n in g o f th e u n itb e fo r e th e filte r s . 2 -1 /2 2 NOTES: Subject to change without notice. Printed in U.S.A. 2 2 5 /8
© Copyright 2025 Paperzz