SPLIT-SYSTEM EVAPORATOR BLOWER 5 TONS

JOB NAME
LOCATION
PURCHASER
ORDER NO.
ENGINEER
SUBMITTED TO
Reference
FOR:
SUBMITTED BY
Approval
Construction
DATE
UNIT DESIGNATION:
Schedule No.
MODEL NO.
DIMENSIONS – INCHES
PRODUCT DATA
TOTAL CAPACITY . . . . . . . . . . . . . . . . .
MBH
SENSIBLE CAPACITY . . . . . . . . . . . . . .
MBH
TOTAL SUPPLY AIR . . . . . . . . . . . . . . . .
CFM
TEMP. OF AIR ENTERING
EVAPORATOR COIL . . . . . . . . . . . . .
7/8" HOLE W/BUSHING
IN REAR PANEL
(For Low Voltage
Control Panel)
36-1/8
COOLING PERFORMANCE
/
8-1/2
13-1/4
1-23/32 KNOCKOUT
(Removed only when
Electric Heat Accessory
is used)
AIR
OUT
1
7/8" KNOCKOUT
IN REAR PANEL
(For Power Wiring)
3-7/8
4-1/2
HEATING PERFORMANCE
11-1/2
2-1/4
11-5/8
Refer to field-installed accessories on reverse side.
22-3/4
2-5/16
SUPPLY AIR BLOWER PERFORMANCE
BLOWER MOTOR
AND DRIVE
ACCESS PANEL
(This side inly)
CFM
TOTAL SUPPLY AIR . . . . . . . . . . . . . . . .
TOTAL RESISTANCE EXTERNAL
TO UNIT . . . . . . . . . . . . . . . . . . . . . . .
IWG
BLOWER SPEED. . . . . . . . . . . . . . . . . .
RPM
POWER OUTPUT REQUIREMENT . . . .
BHP
MOTOR RATING . . . . . . . . . . . . . . . . . .
HP
POWER INPUT REQUIREMENT. . . . . .
KW
ELECTRICAL DATA
POWER SUPPLY . . . . . . . . . . . . . . . . . .
3/4
°F DB/WB
FILTER ACCESS
PANEL(This
side only)
20
3-7/8
1-5/8
/
HOLE WITH GROMMET FOR 7/8 O.D.
SUCTION LINE
2
/
1-3/8
TOTAL UNIT AMPACITY. . . . . . . . . . . . .
AMPS
MINIMUM WIRE SIZE . . . . . . . . . . . . . .
AWG
10-3/8
2
(Copper Conductors)
1-3/16
1-1/8
AIR
IN
MAXIMUM FUSE SIZE
DUAL ELEMENT . . . . . . . . . . . . . . . .
22
32
AMPS
UNIT WEIGHT
LBS.
TOTAL OPERATING WEIGHT . . . . . . . .
1
2
3
4
2
MATCHING CONDENSING
UNIT DATA
Model Number
Submittal Form Number
MINIMUM CLEARANCES
Side with RETURN AIR opening . . . . . . . . . . 24"
Side with SUPPLY AIR opening. . . . . . . . . . . 24"
Side with PIPING CONNECTIONS . . . . . . . . 36"
Side opposite PIPING CONNECTIONS . . . . 12"
Side with access for both
POWER & CONTROL WIRING . . . . . . . . . . —
. 3
Bottom . . . . . . . . . . . . . . . . . . . . . . . . . . . . .—
. 4
7/8 O.D. DRAIN
CONN. (Must be
trapped)
NOTE:
(Including field-installed accessories)
1
APPLICATION
2
Overall dimension of the unit will vary if an electric heater, a
supply air plenum or a base is used.
This dimension is required for removal of the coil. Only 26" is
required for normal servicing.
Although no clearance is required for service and operation,
some clearance may be required for routing the power and
control wiring.
Allow enough clearance to trap the condensate drain line.
SPLIT-SYSTEM EVAPORATOR BLOWER
5 TONS
MODEL K—EU060
43-1/8
HOLE WITH GROMMET FOR 3/8 O.D.
LIQUID LINE
FORM 550.13-SD13Y (199)
Supersedes: 550.13-SD13Y (1285)
®
FIELD-INSTALLED ACCESSORIES
SUPPLY AIR PLENUM (1SP0450) . . . . . . . . . . . . . . . . . . . . . . . . . .
RETURN AIR GRILLE (1RG0450) . . . . . . . . . . . . . . . . . . . . . . . . . .
BASE (1BS0450) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(Vertical Application Only)
ELECTRIC HEATER* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Model Number
Volts) . . . . . . . . . . . . . . . . . . .
MBH
Capacity (@
KW
Power Input Requirement . . . . . . . . . . . . . . . . . . . . . .
(Less Blower Motor)
STEAM COIL (1NF0450). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Steam Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PSIG
Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MBH
LBS/HR
Steam Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
°F
Entering Air Temperature . . . . . . . . . . . . . . . . . . . . . . .
HOT WATER COIL (1HW0450) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MBH
°F
Entering Water Temperature . . . . . . . . . . . . . . . . . . . .
GPM
Water Flow Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
°F
Entering Air Temperature . . . . . . . . . . . . . . . . . . . . . . .
PSI
Water Pressure Drop . . . . . . . . . . . . . . . . . . . . . . . . . .
* Units with electric heat have a single source power supply
Refer to PRODUCT DATA on front side for electrical data.
Four 3/8" – 16 weld nuts are provided in the unit support angles for ceiling suspension. Knockouts
are provided in panels for access to these weld nuts. Support rods must be supplied in the field.
SUSPENSION WEIGHTS, LBS.
A
B
C
D
ACCESSORY DIMENSIONS – INCHES
ELECTRIC HEATER
7 /8
1
SUPPLY AIR PLENUM
7 /8
2 0 -1 /8
4
1 /2
5 -1 /4
1 3
1 -1 1 /1 6
1 1 -1 /4
1 5 -3 /4
1 6 -7 /8
A C C E S S O P E N IN G F O R
P O W E R S U P P L Y W IR IN G
7 -5 /8
1 -3 /4
2 4 -3 /8
2
3 /4
2 -1 /8
2 2 -1 /2
2 5 -1 /8
1 /2
L O C
H E A
P E N
T H E
A T
T W
E T
B L
IO N W
IR IN G
R A T E S
O W E R
H E
H
T
U
3 1 -3 /4
3 6
BASE
B A S E
R E E L E C T R IC
A R N E S S
H E C A B IN E T O F
N IT
2 5 -1 /8
2 -1 /8
2 - 1 /2 k n o c k o u t fo r p o w e r w ir in g
w h e n e le c tr ic h e a te r is u s e d
2 0
RETURN AIR GRILLE
2 2
3 6
R E T U R N A IR G R IL L E
HOT WATER COIL
3 6
STEAM COIL
5
5
3 -3 /8
2 1 -7 /8
2
1 " N P T E
C O N N 'S .
1 -1 /2 " N P T E
C O N N S .
2 1 -7 /8
6 -1 /4
3 6
C o il in s ta lls o v e r th e r e tu r n
a ir o p e n in g o f th e u n itb e fo r e th e filte r s .
1 0 -5 /8
2 -3 /4
2 -5 /8
3 6
1 -1 1 /1 6
C o il in s ta lls o v e r th e r e tu r n
a ir o p e n in g o f th e u n itb e fo r e th e filte r s .
2 -1 /2
2
NOTES:
Subject to change without notice. Printed in U.S.A.
2 2
5 /8