BASIC OCCUPATIONAL ENVIRONMENTAL ADVANCED SPECIAL Sound Level Meters for Noise at Work Measurements Theoptimus redsoundlevelmetersusetheverylatestdigitaltechnologyandindustrialdesigntogiveyou theidealinstrumentforOccupationalandIndustrialHygienenoisemeasurements. Applications • Occupational&IndustrialHygieneNoise Evaluations • NoiseatWorkSurveys&NoiseExposure Calculations • HearingProtectorSelectionusingHMLor OctaveBandMethods • MachineryNoiseTests • NoiseOrdinance&CommunityNoise Assessments • GeneralNoiseMeasurements For Occupational Noise and Industrial Hygiene, measuring the noise exposure of employees quicklyandreliablyisessential.Theoptimusred sound level meters are the ideal instrument for these applications with a clear, high resolution OLEDcolourscreen,awide120dBmeasurement span (up to 140dB(A) and 143dBC Peak) and simultaneous measurement of all available parameters. There’s no setup or complicated configuration needed.Justswitchon,calibrateandpressstart. It’sthatsimple. Key Features • Simpleoperationwithanergonomicdesign • Simultaneousmeasurementofallworkplace noiseparameterswithadditionaltwo“virtual” noisemeters • VoiceTagaudiorecording • Latestdigitaltechnologywithahighresolution colourOLEDdisplayandback-litkeypad • Measureupto140dB(A)and143dB(C)Peak withasinglemeasurementrange • Real-timeOctaveBandFilters • Verylarge4GBmemorywhichcanstoreover 10,000measurements • Longbatterylife VoiceTag audio recording Before each measurement is made, you can record a VoiceTag by simply speaking into the microphone. You can record notes about the measurement location, describe what is being measured or simplystoreinformationthatmaybeusefulata laterdate. The ideal instrument for any application Withtwoadditional“virtual”noisemetersrunning at the same time, you can meet any noise regulation,guidelineorstandard. Whether you need to meet the UK and EU Regulations, measure to OSHA HC & PEL, MSHA, ACGIHoranyotherregulation,anoptimus red is theidealinstrument. Simple operation with advanced technology When you are making a noise lowlight.Thecaseisrobustandcovered measurement, the instrument you are withatactilefinishsoitcanbeusedeven usingshouldnotgetinthewayofgetting ifyou’rewearinggloves. reliableandusefulinformation. Themeasurementdataisdisplayedina The optimus sound level meters have clearandsimpleformatalongwithareal- been designed with ease of use as the timenoisechartsothatyoucanseehow most important feature which lets you thenoisevarieswithtime. get on with measuring and controlling All of the functions of the instrument thenoise. are measured simultaneously, and with The instruments use the very latest in a wide 120dB measurement span you digital technology and industrial design don’tneedtoworryaboutchoosingthe techniques to make everything as clear rightrange.Anoptimuscanmeasureup and simple as possible. We’ve used a to 140dB(A) and 143dB(C) Peak in this highresolutioncolourOLEDscreenwhich singlerange. can be seen in any conditions, and the Just switch on, calibrate and you are keypad will illuminate automatically in readytogo. The ideal solution for occupational noise The optimus red sound level meters are the The custom settings can be used idealsoundinstrumentsforoccupationalnoise to choose any other setup or andindustrialhygienemeasurements,aswell configurationthatyoumayneed. as for basic noise surveys, and will give you Once you’ve chosen the setup alloftheinformationyouneed,rightatyour needed it will be stored so each fingertips. time you use the meter you will havetheinformationyouneed. UK & EU Noise at Work Regulations For the two “virtual” noise meters, IfyouareworkingtotheUKControlofNoise theLAVG,TWA,%DoseandEstimated atWorkRegulationsortheEUPhysicalAgents %Dosearedisplayed. (Noise) Directive, the Leq View gives you the informationthatyouneed. Octave Band Filters for Noise TheLAeqandLCPeakvaluesaremeasuredatthe Control sametimewhichallowtheLEP,d(LEX,8h)andthe Protection Where precision measurements are needed, PeakActionLevelstobedetermined. The CR:162C and CR:161C instruments also Class/Type 1 instruments are available as The LCeq-LAeq (C-A) value is also measured featurereal-timeoctavebandfilterswhichwill well as the General Purpose Class/Type 2 whichcanbeusedtoselectPPEusingtheHML measure the noise in 10 different frequency instruments. method.LAEisalsomeasuredalongwithLZPeak bands. forregulationsthatusethisratherthanLCPeak. Theoctavebandmeasurementismadeatthe & Selecting Hearing same time as the other measurements and OSHA,MSHA & other regulations If you need to meet regulations such as OSHA HC & NC, MSHA HC or ACGIH, the two includes the overall level in each band along with a time history of the bands across the measurementperiod. “virtual”noisemetersintheDoseViewcanbe If there is a need to record and download measurements to a PC, data logging is availablewiththeB&Cversioninstruments. These units are supplied with the NoiseTools software and a USB data cable to allow the quickly configured to provide you with this Basic noise level measurements information. The optimus red instruments can also be The Quick Setup gives access to a number usedforbasicnoisemeasurementswherethe of preset functions including OSHA HC & NC, Sound Level is required, such as community OSHAHC&ACGIHandMSHAHC&EC. Data logging & PC download andnoiseordinanceenforcementandtesting offireandemergencyalarms. measurementinformationtobedownloaded. NoiseTools Software For many users, the most challenging part of a noise survey is the Measurements can be sorted or grouped by any parameter, person, reportingandanalysisoftheresults,andsohavingasimplewaytoview, placeorprojectandmeasurementreportscreatedquicklyandeasily. analyseandprinttheinformationisessential. NoiseTools is fully compatible with the latest versions of Microsoft ThenewNoiseToolssoftwarepackage,suppliedwiththeB&Cversions, Windowsand,aswithallCirrussoftware,updatesareavailablefreeof givesyouaquickandsimplewaytodownload,analyseandreportyour chargefromtheCirruswebsite. noisemeasurementinformation. NoiseTools is supplied free from any licensing restrictions or limits allowing you to install the program on as many PC’s as needed at no Intuitive and simple to use additionalcost. The initial summary screen shows you the most commonly used informationand,throughsimpleicons,givesyouaccesstothedetailed measurementdata.Youcansimplyprintthesummaryscreentogeta quickmeasurementreport. Foradvancedusers,eachandeveryfunctionmeasuredbytheinstrument is available for review and analysis and the data can be exported for furtheruse. VoiceTag audio recordings can be played back for reference and are automaticallystoredwiththemeasurementdata. Where Octave Band data is available, this information can be used by theprogramtocalculatethelevelofprotectionfromarangeofhearing defendersandearplugs. Helping you keep you data organised Overtime,youmayfindthatyouhavealargenumberofmeasurements, informationandnotes. Tohelpyoukeepyournoisemeasurementdataorganisedandeasyto find, NoiseTools allows each measurement to be allocated to people, placesandprojects. Instrument Range & Measurement Kits The optimus red sound level meters can be used for a wide range of Complete measurement kits are available for the optimus instruments occupational noise applications and you can choose from 3 simple whichcontaintheinstrument,anacousticcalibrator,windshield,cables, optionstogettheinstrumentthatmeetsyourneeds.ChoosefromClass batteries and accessories. The measurement kits contain all of the 1orClass2performance,DataLoggingwithPCdownloadand1:1Octave accessoriesneededtocarryoutanoisesurvey. BandFilters. AlloftheinstrumentscanmeasureSoundLevelfunctionsplusLmaxand Lminwithallfrequencyandtimeweightings. TheAversionsmeasuretheIntegratednoiselevelssuchasLeqandLAE, C-A,PeakSoundPressureandthevirtualnoisemetersforOSHA/MSHA/ ACGIH. TheBversionsprovidethesamefunctionsasabovebutwiththeaddition of Data Logging so that measurements can be downloaded to the NoiseTools software. The VoiceTag audio recording is available on the Bversions. TheCversionsaddReal Time Octave Band Filterstothefunctionsof theBversionswhichcanbeusedfortheselectionofhearingprotection. Specificationsandaselectionchartareavailableonthefollowingpage. Specifications Applicable Standards IEC61672-1:2002Class1orClass2GroupX IEC60651:2001Type1IorType2I IEC60804:2000Type1orType2 IEC61252:1993PersonalSoundExposureMeters ANSIS1.4-1983(R2006),ANSIS1.43-1997(R2007) ANSIS1.25:1991 1:1OctaveBandFilterstoIEC61260&ANSIS1.11-2004(C variants) Integrator Quick settings EU,OSHAHC&OSHANC,OSHAHC&ACGIH MSHAHC&MSHAEC,Custom1&Custom2 Microphone Class1InstrumentsMK:224pre-polarized Class2InstrumentsMK:216pre-polarized Batteries 4xAAAlkaline Measurement Functions CR:162A & CR:161A Displayed Functions LXY,LXYMax,LXYMin LXeq,LCPeak,LZPeak,LCeq-LAeq,LXE GraphofShortLAeq,LCPeak Integrators2&3:TWA,Dose%,EstDose% MeasurementRunTime Size 283mmx65mmx30mm Weight 300gms/10oz CR:162B & CR:161B Displayed Functions LXY,LXYMax,LXYMin LXeq,LCPeak,LZPeak,LCeq-LAeq,LXE GraphofShortLAeq,LCPeak MeasurementRunTime Integrators2&3:TWA,Dose%,EstDose% Battery life Typically16hours Microphone Preamplifier MV:200ERemovablePreamplifier External Power 5vviaUSBSocketfromPCorPowerSupply 5v-15vviaMultiIOsocket Total Measurement Range: 20dBto140dBRMSSingleRange NoiseFloor:<18dB(A)Class1,<21dB(A)Class2 Stored Functions LXYMax&TimeHistoryofLXYMax LAeq,LCeq,LZeq,LCPeak,LZPeak TimeHistoryofLAeq,LCeq,LZeq,LCPeak,LZPeak Integrators2&3:LAVG,TWA.%Dose TimeHistoryofLAVG Tripod Mount 1/4”Whitworthsocket Frequency Weightings RMS&Peak:A,C,&ZMeasuredSimultaneously FrequencyBands:10OctaveBands(31.5Hzto16kHz,C Versionsonly) Connections USBTypeBtoPC Multi-pinIOforexternalpower Time Weightings Fast,Slow&ImpulseMeasuredSimultaneously Display HighresolutionOLEDdisplaywithambientlightsensor& illuminatedkeypad Memory 4GBExpandablewithupto10,000measurementsstored(B &CVersions) Time History Data Rates (Global settings) 10ms,62.5ms,125ms,250ms,1/2sec,1sec,2sec(User selectable) VoiceTag Audio Recording (B & C Versions) 30secondsofaudiorecordingwitheachmeasurement Integrators Threesimultaneous“virtual”noisemeters Integrator1ispresettoQ3forLeqfunctions Integrators2&3canbeconfiguredwiththefollowing: Q3,4or5 Threshold:70dBto120dB(1dBsteps) TimeWeighting:NoneorSlow CriterionLevel:70dBto120dB(1dBsteps) CriterionTime:1to12hoursin1hoursteps Case Material:HighImpactABS-PCwithsofttouchback&keypad Environmental Temperature Operating-10°Cto+50°C Storage-20°Cto+60°C Humidity Upto95%RHNonCondensing Electromagnetic performance IEC61672-1:2002&IEC61672-2:2003 ExceptwheremodifiedbyEN61000-6-1:2007&EN610006-1:2007 Language options English,French,German,Spanishasstandard Otherlanguageoptionsmaybeavailable Software Support NoiseToolsDownload,Configuration&Analysissoftware suppliedasstandard. CompatiblewithMicrosoftWindowsXP,Vista&7(32bit& 64bit) CR:162C & CR:161C Displayed Functions LXY,LXYMax,LXYMin LXeq,LCPeak,LZPeak,LCeq-LAeq,LXE GraphofShortLAeq,LCPeak MeasurementRunTime Integrators2&3:TWA,Dose%,EstDose% Real-TimeOctaveBandFilters Stored Functions LXYMax&TimeHistoryofLXYMax LAeq,LCeq,LZeq,LCPeak,LZPeak TimeHistoryofLAeq,LCeq,LZeq,LCPeak,LZPeak Integrators2&3:LAVG,TWA.%Dose TimeHistoryofLAVG OctaveBands:OverallLeq&LeqTimeHistoryforeachband MeasurementRunTime Time&DateofMeasurementStart wherex=A,C,Z;y=F,S,I OtherfunctionsmaycalculatedbytheNoiseToolssoftware anddisplayedondownload. Notes 1.Fordetailsofthedisplayedandstoredparameters,pleaserefertothe optimusredtechnicalspecificationdatasheet. Allspecifications,featuresandvaluesaretypicalandaresubjecttochange withoutnotice. Instrument Selection Function Class1 Class2 SoundLevel Functions Leq/Peak Functions TWA/Dose Functions Data Logging VoiceTag Recording 1:1Octave BandFilters Software Support Yes Yes Yes Yes CK:162A Yes Yes Yes CK:161A Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes CK:161B Yes Yes Yes Yes Yes Yes Yes CK:162C Yes Yes Yes Yes Yes Yes Yes CK:161C MeasurementKit Instrument CR:162A CR:161A Yes CR:162B CR:161B Yes Yes CR:162C CR:161C Yes Yes Standard Accessories Theoptimussoundlevelmetersaresupplied,asstandard,withthefollowing accessories: UserManual CertificateofCalibration USBData/PowerCable Windshield NoiseToolsSoftwareCD(RequiresBorCVersiontodownloadmeasurements) AcousticHouse BridlingtonRoad Hunmanby NorthYorkshire YO140PH UnitedKingdom cr16x/01/2010/r1EN T:08452302434(UK) +441723891655 F:+441723891742 E:[email protected] W:www.cirrusresearch.co.uk CK:162B Measurement Kits Theoptimussoundlevelmetersareavailableasacompletemeasurementkit withthefollowingaccessories: optimusSoundLevelMeter CR:514Class2orCR:515Class1AcousticCalibrator UA:23790mmWindshield CK:280CarryingCase UserManual&CertificatesofCalibration USBData/PowerCable&NoiseToolsSoftwareCD (RequiresBorCVersionto downloadmeasurements)
© Copyright 2026 Paperzz